ELGA PURELAB flex 3/4 Operators Manual
TABLE OF CONTENTS
1. INTRODUCTION ............................................................................... 2
1.1 Health & Safety .............................................................................................. 2
1.2 Product Range ............................................................................................... 2
1.3 Use of this Manual .......................................................................................... 2
1.4 Installation .................................................................................................... 2
1.5 Environment .................................................................................................. 2
1.6 Commissioning............................................................................................... 2
1.7 Customer Support .......................................................................................... 2
2. YOUR GUIDE TO THE PURELAB flex 3 & 4 ......................................... 3
3. CONSUMABLES ................................................................................. 4
4. OPERATION ..................................................................................... 5
5. CUSTOMIZED OPERATION ................................................................ 5
6. PURIFIED WATER OUTLET CONNECTION ......................................... 6
7. MAINTENANCE ................................................................................. 8
7.1 Replacing Ultraviolet lamp (LC210) ................................................................... 8
7.2 Cleaning the Inlet Filter Assembly .................................................................. 10
7.3 Replacing the Reverse Osmosis Module (LC217) ............................................... 11
7.4 Replacing the Composite Vent and Point-of-Use Filters ...................................... 11
8. SELF HELP GUIDELINES ................................................................. 12
9. HEALTH AND SAFETY NOTES .......................................................... 13
9.1 Environment ................................................................................................ 13
9.2 Display Handset ........................................................................................... 13
9.3 Electricity .................................................................................................... 13
9.4 Ultraviolet Light ........................................................................................... 13
9.5 Residual Biostat ........................................................................................... 14
9.6 Control of Substances Hazardous to Health (COSHH ) ........................................ 14
10. TECHNICAL SPECIFICATIONS ........................................................ 15
11. USEFUL CONTACT DETAILS ............................................................ 17
12. WARRANTY / CONDITIONS OF SALE .............................................. 18
The information contained in this document is the property of VWS (UK) Ltd, trading as
ELGA LabWater, and is supplied without liability for errors or omissions.
No part of this document may be reproduced or used except as authorized by contract or
other written permission from VWS (UK) Ltd. The copyright and all restrictions on
reproduction and use apply to all media in which this information may be placed.
VWS (UK) Ltd. pursue a policy of continual product improvement and reserve the right to
alter without notice the specification, design, price or conditions of supply of any product
or service.
ELGA
£
and PURELAB£ are registered trademarks of VWS (UK) Ltd.
PURELAB flex 3/4 MANU39265 Version 01 – 09/10 Page 1
© VWS (UK) Ltd. 2010 – All rights reserved.
![](/html/a4/a4cf/a4cfe49a7fbdd42a95a6fc7bd469229553c2ae7893e6763688fdeda91e783682/bg3.png)
PURELAB flex 3/4 Operators Manual ELGA
1. INTRODUCTION
1.1 Health & Safety
Please ensure you read the Health & Safety notes in Section 9.
1.2 Product Range
This Operators Manual has been prepared for PURELAB flex product models:
x PURELAB flex 3 (Ultra Pure Water (Type I) Directly from tap water)
x PURELAB flex 4 (Ultra Pure Water (Type I) from RO (Type III) feed water)
1.3 Use of this Manual
This manual guides you through the basic operation and maintenance of the PURELAB
flex allowing you to obtain a guaranteed supply of purified water to meet your
requirements.
1.4 Installation
PURELAB flex is supplied with a Quick Start Guide and Quick Reference Guide.
Quick Start Guide shows you how to install and commission the PURELAB flex.
Quick Reference Guide shows you how to perform day to day functions in order to get
the most from your PURELAB flex without having to refer to the Operators Manual.
1.5 Environment
The PURELAB flex unit should be installed on a flat, level surface, in a clean, dry
environment. The unit can also be wall mounted using the purpose designed wall
mounting kit against a vertical wall capable of supporting the combined weight of the
unit and mounting kit.
1.6 Commissioning
PURELAB flex is supplied in a preset commissioning mode which has to be completed
before purified water can be dispensed.
1.7 Customer Support
If you need help with your PURELAB flex, please call your local ELGA representative. For
the address of the nearest ELGA LabWater Sales and Service office visit the country list
on our website.
www.elgalabwater.com
Or contact ELGA LabWater at;
E-mail: techsupport@elgalabwater.com
E-mail: info@elgalabwater.com
Page 2 PURELAB flex 3/4 MANU39265 Version 01 - 09/10
![](/html/a4/a4cf/a4cfe49a7fbdd42a95a6fc7bd469229553c2ae7893e6763688fdeda91e783682/bg4.png)
ELGA PURELAB flex 3/4 Operators Manual
2. YOUR GUIDE TO THE PURELAB flex 3 & 4
PURELAB flex 3/4 MANU39265 Version 01 – 09/10 Page 3
![](/html/a4/a4cf/a4cfe49a7fbdd42a95a6fc7bd469229553c2ae7893e6763688fdeda91e783682/bg5.png)
PURELAB flex 3/4 Operators Manual ELGA
3. CONSUMABLES
Consumables
Part No. Description
Typical Service
Life*
LC214 Purification Pack 6 months 2 years
LC209 Sanitization Pack Not Applicable 2 years
LC210 185/254nm UV Lamp 12-18 months 5 years
LC145 0.2µm Microfilter - Point-of-Use 90 Days 2 years
LC197 Biofilter – Point-of-Use 90 Days 2 years
LC216 Composite Vent Filter 1 Year 2 years
LC217 Reverse Osmosis Module Typical life 2-
*Service Life is an estimate only, and will depend on the application and feed water
quality. Please take care to ensure you order the correct consumable items.
Max. Shelf
Life
2 years
Page 4 PURELAB flex 3/4 MANU39265 Version 01 - 09/10
![](/html/a4/a4cf/a4cfe49a7fbdd42a95a6fc7bd469229553c2ae7893e6763688fdeda91e783682/bg6.png)
ELGA PURELAB flex 3/4 Operators Manual
4. OPERATION
PURELAB flex 3 & 4 provides high purity water typically where daily usage does not
exceed 10 liters/day.
To provide the ultimate purity, water is re-circulated through a range of treatment
technologies and stored in an internal reservoir.
The reservoir is filled automatically from either a potable water or pre-treated supply.
Please refer to Section 9. Technical Specifications for details.
During periods of non-use the unit will automatically operate in intermittent (10 minutes
every 2 hours) re-circulation mode to maintain water purity with maximum efficiency.
Refilling of the reservoir is determined by usage and achieved in the following ways;
1. AUTOMATIC REFILL. When the water level in the reservoir reaches <4 liters the
PURELAB flex will begin to refill. An option in main menu allows ‘Refill set point’ to
be adjusted. Follow instructions on the Dispense handset.
2. INITIATING A RESERVOIR REFILL. Pressing the Initiate Reservoir Refill button on
the display handset for 2 seconds.
3. MANUAL REFILL. Water added directly into the reservoir by removing the
Composite Vent Filter.
4. TIMED AUTO REFILL. The timed auto refill is a feature downloadable from the
website (only available when the clock feature is selected). The timed auto refill
allows the user to set a time at which the system will automatically enter a refill
cycle. With Auto Refill set to 16:00 the unit will enter refill cycle at 4pm everyday.
The Quick Reference Guide shows you how to perform day to day functions in order to
get the most from your PURELAB flex without having to refer to this Operators Manual.
5. CUSTOMIZED OPERATION
It’s possible to customize your PURELAB flex by downloading additional features and
changing your current settings.
To find out more, please visit www.purelabflex.com
Additional features will be added periodically.
PURELAB flex 3/4 MANU39265 Version 01 – 09/10 Page 5