elero Revio-868-P Operating Instructions Manual

elero GmbH
Antriebstechnik Linsenhofer Str.59–63 D-72660 Beuren info@elero.de www.elero.com
Revio-868-P
Please take care of the operating instructions!
Nr. 18100.8001/0705309308 00
GB
elero
Safety instructions
GB-2
Risk of injury due to electrocution.
• The connections to the 230 V mains must be
made by authorised specialist personnel.
• De-energise the connection line prior to installation.
• The regulations of the local energy supply company as well as the regulations for wet and damp rooms according to VDE 100 must be followed when making the connections.
• Use only in dry rooms.
• Only use unmodified original elero electrical parts.
• Keep persons away from the operating range of the system.
• Keep children away from the controls.
• Follow the relevant country-specific regulations.
• If one or more devices are used for controlling the system, the operating range must stay visible during operation.
GB
Warning!
Safety instructions......................................... GB-2
Explanation of buttons and display ...................... GB- 3
General information ....................................... GB-4
Intended use................................................ GB-4
Installation/connection.................................... GB- 5
ProLine drive connection........................... GB-6
Connection of drive and control unit from
another manufacturer ............................. GB-6
Explanation................................................. GB-7
Out vb terminal.................................... GB-7
Venetian blind jumper ............................. GB- 7
Group control jumper.............................. GB-7
Programming the transmitter/channel................... GB-8
Connection of a tubular or venetian blind motor GB- 8
Programming further transmitters ............... GB-8
Positions ............................................ GB-8
Approach positions................................. GB-8
Delete positions/delete transmitter .............. GB-8
Technical data.............................................. GB-9
Notes on troubleshooting ................................. GB-9
General conformity declaration........................... GB-9
Contents
GB-1
General information/ intended use
GB-4
General information
The Revio-868-P is an flush mounted radio receiver. It is suitable for control of 230 V roller shutter,blind and venetian blind motors. In addition you can control all ProLine control units as well as control units from another manufacturer via the potential-free outputs.
Intended use
The Revio-868-P can be used to control roller shutter, awning and venetian blind systems and control units from another manufacturer.
• Please ensure that the radio installations are not operated in areas of heightened possible interference. (e.g. hospitals,airports ...).
• The remote control is only approved for devices and systems for which any malfunction of the manual transmitter or receiver would not result in a risk for persons, animals or property,or if such a risk is covered by other safety devices.
• The operator has no protection whatsoever from interferences by other radio emitters and local terminals (e.g. also from radio installations), that are normally used on the same frequency range.
• Only use radio receivers with equipment and units approved by the manufacturer.
GB
Explanation of buttons and display
GB-3
Explanation of buttons and display
Revio-868 P
C
28 410.0001
JA L L N
P
GR
230V 50Hz
P button
L Phase
N
Neutral conductor motor connection/ mains connection
JA Venetian blind mode
(for JA mode jumper between JA and L)
GR Group control unit
(for group control jumper between GR and L)
Out vb
(potential­free outputs)
n
n
n
n
n
n
n
elero
Connection
GB-6
GB
Installation/connection
GB-5
Drive connection
ProLine connection
Connection of drive and control unit from another manufacturer
Note: Radio systems, which operate on the same frequency, can
lead to reception of interferences. Please note, that the range of the radio signal is limited by
the government and the built environment.
1. Place the Revio-868-P in the socket.
2. Connect the stripped cable ends without connector sleeves as
follows:
Connection
The design for a control device can be found in the controller catalogue.
Warning!
Risk of injury due to electrocution!
• The connection must only be made by an authorized specialist!
• The device only offers protection against touch by the back of the hand, no protection against accidental contact.
• Do not kink, shorten or extend the aerial.
• Only operate button P with insulated tools (4 KV voltage protection).
• If more than one drive is controlled using the Revio-868-P the drives must be decoupled with relay controls.
• Note the switching current of the device.
Precondition: flush-mounted socket Ø 58 mm deep.
Note: Ensure optimum radio reception.
GR
P
C
Mains
N
L
NLJAL
PE
Revio-868 P
1~
M
L
N
Mains
Central
6
CLN
Single
1
4
3
2
5
Netz N
L
PE
control units
to further
GR
P
C NLJAL
VarioTec
M 1~
Revio-868 P
P
GR
C NLJAL
Mains
N L
C
Revio-868 P
M
Control unit from another
manufacturer
Programming the transmitter/channel
GB-8
Commissioning (Connection for a tubular motor or venetian blind motor or ProLine or control unit from another manufacturer)
Precondition: The Revio-868-P is installed.
(Z See Chapter connection RM/JA) The end positions must be set.
1. When the power supply is restored or by pressing the P-button (min. 5 Sec) on the Revio-868-P, the device is ready to programme for 5 minutes
2. Programme the transmitter (Z see transmitter instructions).
Programming further transmitters
Z see transmitter instructions
Programme positions
Z see transmitter instructions
Approach positions
Z see transmitter instructions
Delete positions/delete transmitter
Z see transmitter instructions
GB
Explanation
GB-7
Out vb connection terminals for motor connection
The outputs are provided for sequential control units. The arrows on the device indicate the direction of travel.
Venetian blind jumper between JA and L
If a wire jumper is used between L and coding terminal JA,you can control the installation in inching mode. However, if you press a travel key for longer than 3 seconds the Revio-868-P goes into self-holding mode.
Group control jumper between GR and L
If a wire jumper is inserted between L and the coding terminal GR, you can control a group with the Revio-868-P.
P button
A break in the power supply is simulated by pressing the P button (needed to program the transmitter).
Warnhinweise
GB-10
Technical data/information for trouble-shooting/ general conformity declaration
GB-9
GB
Rated voltage 230 V AC / 50 Hz Switching current 3 A / 230 V Protection class IP 20 Permitted ambient temperature 0 to +55 °C Radio frequency 868,3 MHz Type of mounting Flush-mounted l 58 mm
wall installation. Surface-mounted in
corresponding housing Dimensions L 50 x W 48 x H 27 mm Maximum number of transmitters 16 transmitters
Technical data
Notes on troubleshooting
Fault Cause Remedy
Drive does not run. False connection. Check connection. Drive operates in the Directions are incorrectly Delete transmitter
wrong direction. programmed. and program correctly. No radio reception. 1. Transmitter is not 1. Program the
programmed. transmitter.
2. No power supply. 2. Switch on power supply.
Bad radio reception. Aerial or receiver Change position
in unfavourable position. of receiver or aerial.
General conformity declaration:
Herewith the company elero GmbH declares that the Revio-868-P device satisfies the basic requirements and other relevant regulations of the 1999/5/EC guidelines.