Elenos E10000X User Manual

Page 1
USER MANUAL
E10000X
FM SOLID STATE AMPLIFIER WITH WEB INTERFACE
Rev. 00 - 01/12/2016
Cod. MAN1043UUK
Preliminary
Page 2
Operative Office: via G. Amendola 9, 44028 Poggio Rena-
tico (Fe) ITALY
C.C.I.A.A. 101 216, C.Fisc. e P.IVA IT00415540384
UNI EN ISO 9001:2008 certified company
Certificate No.102222A
We kindly remind you to register your product on http://www.elenos.com/product­registration/
For further information and help please contact the Customer Service:
Elenos
Ph : +39 0532 829965 Fax : +39 0532 829177 E-mail : [email protected] Internet web site : www.elenos.com
Elenos USA
2561 NW 74th Ave, Unit A-16, 33122 Miami (Florida), Ph +1 855-305-3058
We kindly recommend you to fill in the RMA module (ITA http://www.elenos.com/it/ elenos-rma/ o ENG http://www.elenos.com/elenos-rma/) and to report the apparatus serial number (available on identification label).
Elenos s.r.l. hereby declares that the present device is compliant with 1999/05/CE directive.
For further detailes please see “CE marking” section.
All copyrights are reserved, you may not reproduce any part of this manual, in any form, wi­thout the express written permission of Elenos S.r.l.
Page 3
3
Revision
N° Date Description
00 01/12/2016 First release
Revision
Preliminary
Page 4
4 Index
Index
1 Informative letter ������������������������������������������������������������������������������������������������������������7
1�1 Personnel in charge �������������������������������������������������������������������������������������������������8 1�2 Warranty ������������������������������������������������������������������������������������������������������������������8 1�3 Exclusion ������������������������������������������������������������������������������������������������������������������9 1�4 Exemption from liability ������������������������������������������������������������������������������������������9
2 Identification �����������������������������������������������������������������������������������������������������������������11
2�1 Labels ���������������������������������������������������������������������������������������������������������������������12
2�1�1 IDENTIFICATION LABEL �������������������������������������������������������������������������������������12 2�1�2 ASSISTANCE LABEL ������������������������������������������������������������������������������������������� 12 2�1�3 WARRANTY SEAL ����������������������������������������������������������������������������������������������13 2�1�4 SERIAL NUMBER SEAL ��������������������������������������������������������������������������������������13
3 Safety ����������������������������������������������������������������������������������������������������������������������������15
3�1 Safety precautions �������������������������������������������������������������������������������������������������16 3�2 First aid ������������������������������������������������������������������������������������������������������������������18
3�2�1 Treatment of electrical burns ������������������������������������������������������������������������� 18
3�2�1�1 Extensive burns and skin cuts �����������������������������������������������������������������18 3�2�1�2 Less severe burns (1st and 2nd degree) ������������������������������������������������18
3�2�2 Treatment of electric shocks ��������������������������������������������������������������������������19
3�2�2�1 If the victim is unconscious ���������������������������������������������������������������������19 3�2�2�2 If the victim is responsive �����������������������������������������������������������������������19
3�3 Workplace characteristics ��������������������������������������������������������������������������������������20
3�3�1 Room characteristics ��������������������������������������������������������������������������������������20 3�3�2 Electrical system features �������������������������������������������������������������������������������20
4 Presentation ������������������������������������������������������������������������������������������������������������������21
4�1 Connections ������������������������������������������������������������������������������������������������������������22
4�1�1 Overview ��������������������������������������������������������������������������������������������������������22
4�1�1�1 Connections and controls - front panel ���������������������������������������������������22 4�1�1�2 Connections - rear panel �������������������������������������������������������������������������22
4�1�1�3 Connectors Pinout �����������������������������������������������������������������������������������23 4�2 Datasheet ���������������������������������������������������������������������������������������������������������������24 4�3 Protections �������������������������������������������������������������������������������������������������������������26
4�3�1 Software protections ��������������������������������������������������������������������������������������26
4�3�1�1 IPF (Intelligent Proportional Foldback) ���������������������������������������������������26
4�3�1�2 IPC (Intelligent Power Control) ��������������������������������������������������������������� 26
4�3�1�3 Safety Management (“Lifextender”option) ® ......................................... 26
4�3�2 Hardware protections ������������������������������������������������������������������������������������� 28
5 User instructions������������������������������������������������������������������������������������������������������������29
5�1 User interface ���������������������������������������������������������������������������������������������������������31
5�1�1 Menu Tree �������������������������������������������������������������������������������������������������������32
5�1�2 Amplifier Control Panel ����������������������������������������������������������������������������������33 5�2 Alarms/Warnings/Status list ���������������������������������������������������������������������������������47 5�3 SMS list �������������������������������������������������������������������������������������������������������������������51
5�3�1 SMS commands (sending) ������������������������������������������������������������������������������52
5�3�2 Status/alarm SMS (receiving) - examples ����������������������������������������������������� 52 5�4 External devices connectable ��������������������������������������������������������������������������������55
5�4�1 Connecting to a LAN/PC ���������������������������������������������������������������������������������56
5�4�2 Connecting to a Changeover/Audio Matrix ���������������������������������������������������57
Page 5
5Index
Index
6 WEB interface ����������������������������������������������������������������������������������������������������������������59
6�1 Remote control - first connection �������������������������������������������������������������������������� 62 6�2 Accounts �����������������������������������������������������������������������������������������������������������������63
6�2�1 Users management ����������������������������������������������������������������������������������������64
6�0�1�1 Adding a new user/manager �����������������������������������������������������������������65 6�0�1�2 Editing/deleting an existing account �����������������������������������������������������66 6�0�1�3 Editing the user’s preferences �����������������������������������������������������������������67
6�0�2 Profiles ������������������������������������������������������������������������������������������������������������68
6�0�2�1 Reconfiguring the own account� ������������������������������������������������������������� 68
6�1 System �������������������������������������������������������������������������������������������������������������������69
6�1�1 System Settings ����������������������������������������������������������������������������������������������70
6�1�1�1 Network���������������������������������������������������������������������������������������������������70 6�1�1�2 Modules configuration ����������������������������������������������������������������������������71
6�2 Events ���������������������������������������������������������������������������������������������������������������������73
6�2�1 Events �������������������������������������������������������������������������������������������������������������74
6�2�1�1 Senders management �����������������������������������������������������������������������������74 6�2�1�2 Sender SMS/email configuration ������������������������������������������������������������75 6�2�1�3 Destinatios management �����������������������������������������������������������������������76 6�2�1�4 Adding a new destination ����������������������������������������������������������������������77 6�2�1�5 Profiles management �����������������������������������������������������������������������������78 6�2�1�6 Selecting the events to add to profiles���������������������������������������������������79 6�2�1�7 Destinations profile management ����������������������������������������������������������80
6�3 RTC/UTC ������������������������������������������������������������������������������������������������������������������ 81
6�3�1 Clock Settings �������������������������������������������������������������������������������������������������82
6�3�1�1 Choosing between external and internal RTC ����������������������������������������83 6�3�1�2 Choosing a NTP server ����������������������������������������������������������������������������84 6�3�1�3 Adding a new NTP server������������������������������������������������������������������������85 6�3�1�4 Choosing the Timezone ���������������������������������������������������������������������������86
6�4 User interface ���������������������������������������������������������������������������������������������������������87
6�4�1 Telemetry��������������������������������������������������������������������������������������������������������88
6�4�1�1 RF Power Amplifier ���������������������������������������������������������������������������������88 6�4�1�2 Power Supply Units (PSU) �����������������������������������������������������������������������89 6�4�1�3 Profiles ����������������������������������������������������������������������������������������������������90 6�4�1�4 Editing profiles ����������������������������������������������������������������������������������������91 6�4�1�5 User Alarms ���������������������������������������������������������������������������������������������92 6�4�1�6 Transmitter info ��������������������������������������������������������������������������������������� 93
6�4�2 Events �������������������������������������������������������������������������������������������������������������94
6�4�2�1 Active alarms� �����������������������������������������������������������������������������������������94 6�4�2�2 Events history ������������������������������������������������������������������������������������������95 6�4�2�3 Inbond SMS ���������������������������������������������������������������������������������������������96
6�4�3 Control Centre ������������������������������������������������������������������������������������������������� 97
6�4�3�1 Energy Profiles� ���������������������������������������������������������������������������������������97 6�4�3�2 Editing an Energy Profiles �����������������������������������������������������������������������99 6�4�3�3 Energy Cost Profiles �������������������������������������������������������������������������������100 6�4�3�4 Editing an Energy Cost Profiles �������������������������������������������������������������101 6�4�3�5 Editing an Energy Band Cost �����������������������������������������������������������������102
Page 6
6 Index
Page 7
7
Informative letter
Dear Customer, Thank you for choosing an Elenos product. ELENOS s.r.l. produces solid state VHF/FM sound broadcasting transmitters ranging from minimum power of 10W to maximum power of 30kW, exchange units, remo­te control units, etc.
The equipment has been produced to ensure constant performance over time as long as periodical controls and essential maintenance works are carried out as required.
However, before attempting any kind of operation an accurate reading of this ma­nual and of all relevant documentation attached is recommended to the user.
ELENOS s.r.l Management
1 Informative letter
Informative letter
1 Informative letter ������������������������������������������������������������������������������������������������������������7
1�1 Personnel in charge �������������������������������������������������������������������������������������������������8 1�2 Warranty ������������������������������������������������������������������������������������������������������������������8 1�3 Exclusion ������������������������������������������������������������������������������������������������������������������9 1�4 Exemption from liability ������������������������������������������������������������������������������������������9
Page 8
8
1.1 Personnel in charge
This manual has to be intended as an integral part constituting the equipment, and must be readily at hand to all the personnel responsible for its installation, use and mainte­nance. The installation, use and maintenance of the device concerned in this case must be per­mitted exclusively to properly trained and qualified personnel, who must have received the appropriate training on the use of the equipment and who are aware of every pos­sible risk occurring when operating with devices connected to dangerous voltage electri­cal networks, operating with high internal voltages and generating high radiofrequency output power. This manual does not claim to be a comprehensive collection of safety standards required for the use of the equipment. However, the user and the maintenance technician are required to know the content of these manual and of all its connected attachments. This equipment must be used only by holders of governmental licenses and/or ministe­rial authorizations only.
1.2 Warranty
The products sold to the Customer by Elenos Srl are covered by a 24-month warranty star­ting from the FOB date of shipment from Elenos Srl site; this warranty is granted both to the Customer and to any other possible subsequent purchaser of the product and covers any kind of fault caused by defective components of the product itself, as long as it is maintained in an excellent controlled condition. It is essential to the effective coverage of the warranty issued by Elenos Srl the registration of the product by the Customer through the web site www.elenos.com/product-registration/.
In case the Customer detects a failure under warranty, he must give immediate written notice to Elenos Srl and send the product at his own expense to the Elenos Srl headquar­ter or to the nearest qualified Elenos Srl centre; in case of shipment to its headquarter, the latter agrees to replace within the next 45 days for free the defective component; in case of shipment to a qualified service Elenos Srl, the latter shall refund the cost of the intervention on the faulty component on the basis of a fixes and agreed tariff in advance between the customer and Elenos Srl. If the product purchased by the customer forms part of the so-called products “Reduced mobility” (weight higher of Kg. 50), the maintenance or replacement of the defective component will be in the place where the equipment is located and will be done by the technicians of the closer technical center qualified by Elenos Srl. All this after the evaluation by a technician designated from Elenos on the presence of a case of exclusion from the guarantee.
For details, please consult the Terms and Conditions documents.
Informative letter
Page 9
9
1.3 Exclusion
The customer expressly accepts the exclusion from the terms of Elenos Srl warranty’s co­verage all damages caused by electrical discharges (lighting) and incorrect power supply voltages, as well as by the Customer’s negligence, carelessness or unskillfulness, or by unauthorized staff maintenance operations or by replacements of original parts of the equipment with new systems or spare parts not directly supplied by Elenos Srl or by its authorized distributors, or by a use of the product other than those intended for the same product, or from any action or fact attributed to third parties who have access to the pro­duct for the same Customer’s approval or even without the Customer being aware thereof after that the latter has received the delivery of the products.
The warranty expressly excludes coverage for damages caused by fires, floods, or other natural disasters, wars, revolts, as well as in all cases the equipment becomes the mate­rial object of a crime.
The warranty is also expressly excluding coverage for damages occurred after the delivery of the equipment by Elenos Srl to the carrier, being the Customer responsible for any risk related to the transport, since its time-frames, costs and methods are chosen and covered by the same Customer.
1.4 Exemption from liability
The customer is responsible for installation, maintenance and control products, as well as verification that the climatic and environmental conditions, in which the products are placed, are suitable for their use and do not affect the operation. All in observance of Elenos Srl’s manual attached to the product purchased, that must be the reference for the customer to require validly and effectively the replacement or repair under warranty. Conversely, if the customer fails to observe the precepts contained in the instruction ma­nual, as well as the minimum care required to the normal user of such equipment, the guarantee granted by Elenos Srl will not operate and the customer himself will totally assume the risk of any damages occurred to the products.
Elenos Srl reserves the right to make possible changes to parts, details and accessories that may be considered opportune to be done for the improvement of the equipment, or to meet the needs connected to constructive and commercial requirements, in any moment, without prior notice of it and without committing to upgrade immediately this manual.
For details, please consult the Terms and Conditions documents.
Informative letter
Page 10
10 Informative letter
Page 11
11
Identifi cation
2 Identification
Identification
2 Identification ....................................................................................................................... 11
2.1 Labels ............................................................................................................................ 12
2.1.1 IDENTIFICATION LABEL .......................................................................................... 12
2.1.2 ASSISTANCE LABEL ................................................................................................ 12
2.1.3 WARRANTY SEAL ................................................................................................... 13
2.1.4 SERIAL NUMBER SEAL ........................................................................................... 13
Page 12
12
On the right side
On the right side
!
2.1 Labels
2.1.1 IDENTIFICATION LABEL
It shows the key features equipment, such as: manufacturing company, product model, power supply type, power consumption and CE marking. Warning: do not ever remove this label.
2.1.2 ASSISTANCE LABEL
It shows the main Elenos customer assistance contacts.
Note: this label may not be present.
Page 13
13
On the screws of the
covers
On the front panel
2.1.3 WARRANTY SEAL
Unauthorized removal or tampering of this seal (positioned over the screws) will make void the warranty.
2.1.4 SERIAL NUMBER SEAL
It shows the serial number of the equipment in numeric and barcode format. In addition, a qr-code for the registration is displayed.
Page 14
14 Identification
Page 15
15
Safety
Safety
3 Safety
All ELENOS s.r.l products are compliant with the safety standards required for this type of equipment.
3 Safety ................................................................................................................................... 15
3.1 Safety precautions .......................................................................................................16
3.2 First aid ......................................................................................................................... 18
3.2.1 Treatment of electrical burns ............................................................................. 18
3.2.1.1 Extensive burns and skin cuts ....................................................................18
3.2.1.2 Less severe burns (1st and 2nd degree) ................................................... 18
3.2.2 Treatment of electric shocks ............................................................................... 19
3.2.2.1 If the victim is unconscious ........................................................................19
3.2.2.2 If the victim is responsive ...........................................................................19
3.3 Workplace characteristics ........................................................................................... 20
3.3.1 Room characteristics ...........................................................................................20
3.3.2 Electrical system features ................................................................................... 20
Page 16
16
!
3.1 Safety precautions
Users must also respect the safety precautions listed below:
• The electrical configuration must not be modified. Upon receipt of the equipment, it’s essential to check if the mains is compatible with the order requirements. In case of non-compliance, please report it immediately to Elenos Srl.
• Protective devices must not be disconnected (with exception of their replacement), altered or modified without authorization.
• Check all safety equipments (e.g. block varistors, current limiters, circuit breakers, etc.) periodically and after a fault occurrence.
• To ensure the staff safety and protect the equipment against damages, it’s absolutely forbidden to use it while covers and/or protection panels aren’t completely installed. In addition, the grounding connection must always be of extremely high quality and in accordance with regulations in force. It is also forbidden to disconnect and/or alter the equipment’s protection systems.
• Before starting any operation, the equipment must be disconnected from the mains. Disconnection must be verified via visual inspection.
• The equipment must be powered exclusively by correct voltage. An incorrect power voltage may damage seriously the equipment and the staff who is working on it. The same information is shown on the product’s nameplate, which is generally placed on the housing. Never remove the nameplate, even if the equipment is resold.
• The equipment must be powered only by electrical systems which are compliant with the regulations in force.
• Further informations may be shown in specific labels placed on the equipment. They are about safety warnings to follow by anyone works on it. The lack of compliance with the rules here described exempts the manufacturer from any responsibility for any damages or accidents that may occur to staff or owners and puts all responsibility to the user himself.
• To ensure the equipment correct working, do not block the fan grills. Do not place the unit near heat sources, flammable products, or in closed rooms with no ventilation.
• It is necessary to respect the general rules and fire fighting for the site that houses the equipment.
• Avoid any liquid contamination. Always disconnect the mains before making any cleaning. Don’t use liquid or spray cleaners.
• Some components contain TOXIC SUBSTANCES, such as BERYLLIUM OXIDE. Please be aware that some countries may apply rules for storing and disposing of hazardous materials.
• Following a visual check, if some component looks damaged, broken or detached, take the utmost care during the equipment manipulation by hands or other means.
Safety
Page 17
17Safety
• Be sure that all people who use or maintain transmitters, in which one or more parts are under dangerous voltage, are able to perform artificial respiration and heart mas­sage. All staff must be trained on how to provide medical first aid in case of emer­gency. It’s strongly recommended to hang, in a visible place, an information poster with clear instructions on first aid to save the people injured in an accident at work and how to provide first aid kits the rooms where electrical devices are installed. It’s also recommended to prepare an action plan in order to ensure fast access to the service of a public or private emergency body, so that it’s easily available for all the people within the site.
The equipment is directly connected to the “building
installation”
There is an interposed structure between the equip-
ment and the “building connection”
Hazardous voltage
Page 18
18
3.2 First aid
This paragraph does NOT represent a complete guide on first aid procedures, but should be understood rather as a brief reference summary. It must be made an urgent duty for all staff who work with the equipment to provide appropriate first aid procedures, in or­der to prevent avoidable deaths.
3.2.1 Treatment of electrical burns
3.2.1.1 Extensive burns and skin cuts
• Cover the burned area with a clean sheet or cloth.
• Don’t break blisters, don’t remove the tissue, don’t remove particles adhered to clothing, or apply any ointment.
• Treat the victim in according to the kind of shock suffered.
• Arrange the transportation to an hospital as quickly as possible.
• If arms and legs are injured, keep them raised.
WARNING: If medical help is not available within one hour and the victim is conscious without gag­ging, give to drink salted water made of 1 teaspoon of salt and half a teaspoon of baking soda for each 250 ml warm water. Let the victim slowly sip this solution, for about four times (half a glass every 15 minutes). Stop the operation if gagging occur. Avoid alcoholic beverages.
3.2.1.2 Less severe burns (1st and 2nd degree)
• On the burns, apply cool (not ice-cold) compress of gauze using the cleanest available cloth.
• Do not break blisters, don’t remove tissue, don’t remove particles adhered to clothing, or apply any ointment.
• If necessary, put on clean and dry clothes.
• Treat the victim in according to the kind of shock suffered.
• Arrange to transportation to an hospital as quickly as possible.
• If arms and legs are injured, keep them raised.
Safety
Page 19
19
Safety
3.2.2 Treatment of electric shocks
3.2.2.1 If the victim is unconscious
Place him flat on his back on a hard surface
A) Airways (pict. a):
• if the victim is unconscious, open his airways
• push the victim’s forehead backwards
• if necessary, open the victim’s mouth
• check the victim’s breathing
B) Artificial respiration (pict. b):
• if the victim cannot breathe, perform the artificial respiration
• incline the victim’s head backwards
• close the victim’s nostrils
• place your mouth on the victim’s mouth
• perform 4 quick blows
• remember to start breathing immediately
C) Circulation (pict. c1):
• check the victim’s pulse (pict. c1)
• if absent, start cardiac massage (pict. c2)
• compress the chest every 1.5 - 2 seconds
• if only one rescuer is present, perform 15 compressions in approximately 80 seconds, + 2 quick blows
• if there are two rescuers, perform 5 compressions in approximately 60 seconds, + 1 quick blow (pict. c3)
WARNING: Do not interrupt the rhythm of compressions when the second rescuer is per­forming artificial respiration.
3.2.2.2 If the victim is responsive
• cover the victim with a blanket
• keep him as calm as possible
• loosen his clothing and place him in a reclining position
WARNING: CALL FOR MEDICAL ASSISTANCE AS SOON AS POSSIBLE ALWAYS
pict. c1
pict. c2
pict. c3
pict. a
pict. b
Page 20
20
3.3 Workplace characteristics
3.3.1 Room characteristics
In order to work freely on the equipment and to be able to perform the relative instal­lation or maintenance operations, it is necessary to keep a minimum distance from the walls on all sides of the machine.
The room must be equipped with an appropriate system of clean and dust-filtered air ventilation with a flow rate suitable for the characteristics of the equipment operating in the room itself.
The exhaust air discharged from the apparatus must be conveyed directly outside. If the length or size of the air duct is likely to introduce a significant loss of air pressure it’s ne­cessary to add an extraction device. The air duct outlet must be equipped with a protec­tive device against the intrusion of insects or other animals. In additions, adequate pre­cautionary measures should be applied against intrusion of liquids or other substances.
The equipment can operate properly if the temperature ranges si from -5°C to +45°C, with 95% RH non-condensing at +40°C.
3.3.2 Electrical system features
The mains installation must be set in accordance with the rules in force. The power supply network must allow an adequate power provision according to the rules in force in the country of installation about quality of the electrical energy supply service.
It’s strongly recommended to use a transformer or network separator and a reduction network for discharging high voltage.
Install a protected overload switch (circuit breaker or fuse) with proper electrical characte­ristics (breaking capacity and current value) according to the absorption of the equipment model.
Use cables of adequate sizes in respect to the rated current absorbed.
Grounding must be performed according to the rules in force. Special care must be ta­ken for the grounding of the antenna system since it’s exposed to electrical atmosphe­ric events. Never forget that, despite the grounding of the equipment frame and the whole antenna system, it’s always dangerous to operate on the equipment in case of bad weather with atmospheric discharge. In fact, in the event of high energy discharge (flash), the equipment frame can instantly reach very dangerous voltage levels, due to the grounding connection inductance. For this reason, the equipment should be installed in rooms in which the staff can remain only for the time necessary for checks and repairs.
Safety
Page 21
4 Presentation
4 Presentation ������������������������������������������������������������������������������������������������������������������������21
4.1 Connections ������������������������������������������������������������������������������������������������������������������ 22
4.1.1 Overview ��������������������������������������������������������������������������������������������������������������22
4.1.1.1 Connections and controls - front panel ����������������������������������������������������� 22
4.1.1.2 Connections - rear panel ����������������������������������������������������������������������������� 22
4.1.1.3 Connectors Pinout ���������������������������������������������������������������������������������������� 23
4.2 Datasheet ��������������������������������������������������������������������������������������������������������������������� 24
4.3 Protections �������������������������������������������������������������������������������������������������������������������26
4.3.1 Software protections ������������������������������������������������������������������������������������������� 26
4.3.1.1 IPF (Intelligent Proportional Foldback) �����������������������������������������������������26
4.3.1.2 IPC (Intelligent Power Control) ������������������������������������������������������������������� 26
4.3.1.3 Safety Management (“Lifextender”option) ® ����������������������������������������� 26
4.3.2 Hardware protections ������������������������������������������������������������������������������������������ 28
Presentation 21
Presentation
A V
°C
W
47.0
XX.X
ZZ.Z
YY.Y
Page 22
Presentation
1 USB Port (Opt�) 2 Status LEDs 3 StandBy Button 4 OnAir Button
20 Grounding Screw 21 RF In N connector 22 RF Out 1+5/8” Line 23 Modem Card (Opt�)
4.1.1.2 Connections - rear panel
5 Graphic Display 6 RF Monitor 7 Local/Remote Switchkey 8 Life Extender Button
9 Escape Button 10 EIA485/Telemetry 11 Encoder/Selector
24 Modem SMA Ant� (Opt�) 25 EIA485 26 Interlock 27 Ethernet Port
28 TC/TS 29 Profiles 30 AC Line Input
4�1 Connections
4.1.1 Overview
4.1.1.1 Connections and controls - front panel
22
6 7 98 10 11
23 24
262728 29 30
25
20 21 22
1 2 3 4 5
Page 23
Presentation
4.1.1.3 Connectors Pinout
WARNING: the frontal USB port (optional) has the standard pinout but is designed exclu­sively for connecting portable devices such as pen drives� Don’t connect hard disk drives� Maximum load: 200mA�
For further information on the electrical connections, refer to the Quick Start�
23
TC/TS Connector (DB25)
Pin Function Type Note Sym Comment
1 Interlock TC Level
Status command�
Active when grounded�
2 Tx On TC Pulse (500mS)
Pulse command�
Active when grounded�
3 Tx Off TC Pulse (500mS)
Pulse command�
Active when grounded�
4 Ref� Power DTM Voltage
0���4V
5 Common Gnd // //
Connected to device
frame�
6 n�c� // // // // 7 Exc� Enable TC Level
Status command�
Active when grounded�
8 n�c� // // // // 9 Common Gnd // //
Connected to device
frame�
10 I IPA DTM Voltage
0���4V
11 Mains Fault TS Level (O�C�)
Externally powered�
Open = active fault�
12 Tx On TS Level (O�C�)
Externally powered�
Closed = Tx On
13 Warning TS Level (O�C�)
Externally powered�
Open = active warning�
14 Alarm Reset TC Pulse
Pulse command�
Active when grounded�
15 Low Power TC Pulse
Pulse command�
Active when grounded�
16 Rsr Power TC Pulse
Pulse command�
Active when grounded�
17 Fwd Power DTM Voltage
0���4V
18 Common Gnd // //
Connected to device
frame�
19 n�c� // // // // 20 n�c� // // // // 21 Common Gnd // //
Connected to device
frame�
22 V IPA DTM Voltage
0���4V
23 Audio Fault TS Level (O�C�)
Externally powered�
Grounded = active alarm�
24 Fault TS Level (O�C�)
Externally powered�
Open = active alarm�
25 Remote TS Level (O�C�)
Externally powered�
Grounded = active alarm�
Profiles Connector (DB25) Pin Function Type Note
1 Channel 1 TC Pulse 2 Channel 3 TC Pulse 3 Channel 5 TC Pulse 4 Spare TC Pulse 5 Common Gnd // 6 Common Gnd // 7 n�c� // // 8 Common Gnd //
9 Common Gnd // 10 Common Gnd // 11 Channel 5 TS Level 12 Channel 3 TS Level 13 Channel 1 TS Level 14 Channel 2 TC Pulse 15 Channel 4 TC Pulse 16 Channel 6 TC Pulse 17 n�c� // // 18 Common Gnd // 19 Common Gnd // 20 Common Gnd // 21 Common Gnd // 22 Common Gnd // 23 Channel 6 TS Level 24 Channel 4 TS Level 25 Channel 2 TS Level
Interlock Connector
Pin Function Type Note
1 Common Gnd // 2 Float Intlk 1 // // 3 Float Intlk 2 // //
Ethernet Connector
Pin Function Pin Function
1 TD+ 5 TCT 2 TD- 6 RD­3 RD+ 7 n�c� 4 n�c� 8 RCT
EIA485 (DB9)
Pin Function Note
1 Tx+ EIA485/422 2 Tx- EIA485/422 3 Rx+ EIA485/422 4 Rx- EIA485/422 5 Common Gnd (frame) 6 Common Gnd (frame) 7 Common Gnd (frame) 8 Common Gnd (frame) 9 Common Gnd (frame)
!
Page 24
Presentation
4�2 Datasheet
GENERAL DATA
Output Nominal Power 10,000 W (adjustable) Operating band 87�5 - 108 MHz Samples RF sample RS232/485 interface Yes
Displaylable parameters number More than 50 on graphic OLED display
or via web interface Adjustments By front panel / web interface Power stage L-DMOS number 14 RF power stage technology ICEFET and ECOSAVING PSUs number 3 (5 kW each one) Dimensions (rack units - W * H * D) 4HE - 48�5 * 17�5 * 80 cm
19,1 * 6,9 * 31,5 inches Weight 47 kg - 103�6 lbs Cooling fans number 6
CONNECTORS
RF output 1 + 5/8” RF input N female RF monitor BNC female Ethernet RJ45 RS232/485 DB9 female (front + rear) GSM antenna SMA female TC/TS DB25 female Profiles DB25 female Mains 6 * terminal blocks + grounding screw Interlock SL-SMT3�50 3pole Grounding M5 threaded screw
RF PERFORMANCE
Iutput impedance 50 Ω Output impedance 50 Ω Automatic RF output power control Stabilized on the set value Overall RF output power stability
+/- 0,1 dB
VSWR
• 2:1 @ rated power
• Automatic power reduction over 1�7:1
• Open and short circuit protection
24
Preliminary
Page 25
Presentation
Harmonic frequencies emission Within ETSI standard Spurious frequencies emission within ETSI standard Driving power 2W typical, with automatic increasing/
decreasing notice for optimal driving power and protection against bad input levels
RF output power range 1,000 to 10,000 W adjustable
INSTALLATION REQUIREMENTS
Power supply • 208V - threephase Delta
• 400V - threephase WYE
• 230V monophase possible by paral­lel connection of suppliers
Power consumption 14kW typical - 15kW max Recommended wiring section 4sqmm / AWG11 Total current consumption 40A per phase @ 208 VAC
20A per phase @ 400 VAC Current absorption may increase in case of lower AC line voltage�
Overall efficiency • 70-73% @ rated power
• 68-70% @ -3dB power
• 65% @ -6dB power
Power factor > 0�95
COOLING SYSTEM
Cooling type Forced air-cooling Air flow 1,000 cbm/h typical (depending on
temperature)
ENVIRONMENT
Operating temperature -5 to +45 °C / 23 to +113 °F Operating humidity 95% @ 40 °C / 104 °F Operatine altitude <3,000 metres / <9840 feet Storage temperature -20 to +55 °C / -4 to +131 °F Storage humidity 90% @ 55 °C / 131 °C Storage altitude <15,000 metres / <49,200 feet
TELECONTROL AND TELEMETRY
Remote control Yes
SNMP Yes
25
Preliminary
Page 26
Presentation
4�3 Protections
4.3.1 Software protections
4.3.1.1 IPF (Intelligent Proportional Foldback)
The IPF is an intelligent system which reduces the equipment’s output power in case of excess of load mismatch, thus preventing the equipment turning off� Foldback acts if the load mismatch increases slowly� If the event is fast (examples: a ligh­ting into a connector, the detachment of a transmission line, a short circuit and so on), the protection acts quickly� The activation of this feature is shown on display and via telemetry as alarm no� “026”�
4.3.1.2 IPC (Intelligent Control Power)
When the equipment is working properly, the IPC keeps the output power constant within +/-1% of the target set, irrespective of mains voltage, temperature and load variations� This greatly contributes to making the equipment insensitive to its working conditions� The IPC also allows to optimize the RF section efficiency by making work the MOSFETs constantly at maximum efficiency, thus minimizing overall electrical consumption�
4.3.1.3 Safety Management (“Lifextender”option) ® The Safety Management consists of algorithms to perform real-time analysis of the transmitter’s operating status� It works in order to maintain the output power set, accor­ding to kind and severity of any anomalies (internal or environmental) which may occur� The Safety Management may perform an output power reduction proportional to the severity of the anomaly that occurs, in order to avoid the progression of the fault� The algorithms act at different levels and in various sections of the equipment: Thermal Management on the RF unit; Current Management, Fault Management and Thermal Ma­nagement on the power supply units; Fault management on the RF unit; Cooling Mana­gement on the fans�
Thermal Management on the RF unit (Lifextender) ® When the temperature measured near to MOSFETs exceeds 72 °C, a first level of derating works moderately trying to reduce the temperature via an output power decrease� This power reduction is the minimum allowed in order to reach a thermal balance at a tempe­rature lower than 72 °C� This decreasing never exceeds 48% in first derating level� Infact, the output power always remains above 52% of that set by the user so that the “-3 dB” warning and relative alarms don’t occur� This first derating level is effective in virtually all cases� The activation of this feature is shown on the display and via telemetry as alarm no� “010”� If the first derating level will be insufficient (extremely rare cases), a second derating le­vel starts, further reducing the power, thus obtaining a thermal balance status compatible with the safe operation of the equipment, even if the output power is below - 3dB (with subsequent alarm no� “005”)� If also the second derating level will be ineffective (in case of external conditions which are not compatible with the safe operation of the equipment), the transmitter is switched off� In this case, when the temperature decreases, the power increases proportionally� If it decreases by 10°C (i�e� it reaches 62 °C) the derating algorithm stops and the full power is restored� After five failed attempts, the logic control unit stops the equipment (alarm no� “003”)�
26
Page 27
Presentation
Current management on the power supply units (Lifextender) ® This is activated when the maximum current rated for continuous operation of the power supply is exceeded� This value is lower than deliverable current limit and represents the threshold which can be exceeded only for short periods (maximum 1 minute each time)� If this situation occurs, the “PSU current derating” function is activated (alarm “013” and, if necessary, alarm “014”) and the ALC management algorithm, running in correct wor­king mode, is replaced by another one wherein the VDS and Bias are determined by the user settings� The current delivered by the power supply units has the highest priority in this case� The current derating is deactivated when the power delivered rises to the value set by the user if the maximum current provided by the power supply units is less than or equal to the maximum value allowed for continuous operation�
Thermal management on the power supply (Lifextender) ® The power supply management algorithm works according to the temperature like that on the RF unit and is logically connected in “OR” to it� The first derating level (acting directly on the output power) is activated when the power supply temperature exceeds 75°C, while the second level is activated - when the first is ineffective - if the temperature does not stabilize below this value� In the last case, the output power is decreased of – 3 dB via the same procedure described for the RF section� The activation of this feature is shown on the display and via telemetry as alarm no� “015” and possibly no� “016”�
Fault Management on the RF modules (Lifextender) ® It manages the maximum deliverable output power according to the number of correct working RF amplifier modules� If one or more MOSFETs are considered faulty (this happens when their absorbtion is 10% below the average value), the RF output power is reduced to the expected value when occurs this kind of fault and the fans speed is pushed to the maximum rate� The fault cases and the corresponding maximum power reacheable levels are described by a complex table obtained via many tests� It is designed to stop the fault spreading and to prevent the MOSFETs that are still working from excessive stress by the ALC algorithm (which would require them to provide all the missing power output)� In order to avoid an excessive number of alarms, no messages are sent when an alarm, if validated, occurs after the adjusting of the output power according to the parameters in table, and only if the -3dB condition is present� The activation of this feature is shown on the display and via telemetry as alarms no� “008” and no� “009”�
27
Page 28
Presentation
Cooling Management on the fan unit (Lifextender) ® In respect to the current cooling requirements, the fan speed rotation is adjusted from a minimum of 60% to a maximum of 120% approx� (these values may change according to the models of used fan)� The cooling demand evaluation is based on accurate mea­surements of the temperature close to each MOSFET and to the power supply units� The Cooling Management aims to: 1� extend the life of the fans; 2� minimize the quantity of dust which can be carried by the air flow; 3� allow the safe operation of the equipment also under extreme temperature condi-
tions;
4� ensure that temperatures of mosfets and power supplies remain as stable as possible
to avoid thermal and mechanical stress; 5� reduce the energy consumption when a strong heat extraction is not needed� Without Lifextender, the fans always operate at 100%�
4.3.2 Hardware protections
The hardware protection system comprises:
• fast electronic and fuse protection for power supply units;
• fast electronic protection on the fan power supply;
• fast protection against excess reflected power (SWR/VSWR) following a strong load
mismatch� This protection is activated when the reflected power value exceeds 10% of the direct one�
The LifExtender can be requested as an option using the previous codes� To be specified in the order�
28
Page 29
29
User instructions
User instructions
5 User instructions
5 User instructions ������������������������������������������������������������������������������������������������������������� 29
5.1 User interface ���������������������������������������������������������������������������������������������������������� 31
5.1.1 Menu Tree �������������������������������������������������������������������������������������������������������� 32
5.1.2 Amplifier Control Panel ����������������������������������������������������������������������������������33
5.2 Alarms/Warnings/Status list ��������������������������������������������������������������������������������� 47
5.3 SMS list ��������������������������������������������������������������������������������������������������������������������� 51
5.3.1 SMS commands (sending) ������������������������������������������������������������������������������52
5.3.2 Status/alarm SMS (receiving) - examples ��������������������������������������������������� 52
5.4 External devices connectable �������������������������������������������������������������������������������� 55
5.4.1 Connecting to a LAN/PC ��������������������������������������������������������������������������������� 56
5.4.2 Connecting to a Changeover/Audio Matrix ��������������������������������������������������57
Set of controls and indicators that allow the user to control the device via the menu in local mode
List of alarms, events and status that the unit can communicate to the user
List of status/commands that the unit can send/receive via SMS
External equipments that can be con­nected to the unit
Page 30
30 User instructions
Page 31
31
Main
Diagnostic
GSM
Modem
System
REMOTE
LOCAL
ESC
User instructions
5�1 User interface
All commands and data displayed by screen are listed on next pages�
Warning: The screens shown below are subject to change without notice and may look some different depending on system configuration.
Important: to be sure that new values entered will be stored, please wait at least 60 seconds before shut down the apparatus�
Rotate clockwise or counterclockwise the encoder to scroll the menu items, to select fields in the screens or to increase/decrease values� Press the encoder to select a menu item, to confirm a selection or to save values� A long press of encoder causes the return to the main screen�
Highlighted boxes show the actual position inside the multilevel menu�
To navigate the entire menu by encoder the equipment has to be set in Local Mode� When the amplifier works in Remote Mode, naviga­ting is possible but the following items of menues aren’t available: “Password Settings”; “Life Extender”; “GSM/Modem Menu” and “Diagnostic Menu”�
Press “ESC” button to exit quickly from the screen wi­thout using the encoder�
Page 32
32
Tx Control Panel
View Tx Parameters 1
View Tx Parameters RF
View Tx Parameters PSU
Alarm List
Events History
Password
Password Setting
Password Recovery
Menu System
Menu Diagnostic
System Config
System Config1
Communication Port Set
System Info
System Time
Clock Pwr Target 1 of 2
Clock Pwr Target 2 of 2
Enable Alarms SMS
Enable Alarms Data
Enable Alarms Timers
Life Extender
Menu GSM Modem
Chatty Board Config
Uart 0 Info
Uart 1 Info
Uart 2 Info
SMS Diagnostic
GSM and Modem Service
Phone n� 1 to 4
Phone n� 5 to 8
Display Alarms Bit
5.1.1 Menu Tree
The red harrow indicates the main screen that appears when the equipment operates in local mode� It’s the first screen of main menu�
Main Screen
User instructions
Page 33
33
REMOTE
LOCAL
Main
Diagnostic
GSM
Modem
System
User instructions
5.1.2 Amplifier Control Panel
Main screen is automatically displayed when the amplifier works in Local Mode� It permits to view and set the main working parameters� It’s also available by navigating main menu and selecting the item “Tx Control panel”�
“ITLK” lit means that an interlock fault line is open� “-3dB” lit means that the RF power output is lower than half target power�
Select on the value of the item “TRG”, press and rotate the encoder to set the power target� Press again to confirm� Select the item “MENU” and press the encoder to return to main menu� Select the item “RFON” and press the encoder to switch on the amplifier section (if the amplifier IS operating, the item is “STBY” and by its selection the amplifier well be switched off)� Select the item “REST” and press the encoder to perform an alarm list reset�
“FWD” indicates the forward power and “REF” the reflected one� “PF 1” indicates that the first profile (Tx reserve in n+1 systems) is selected�
This screen is displayed when the amplifier works correctly (remote mode)� Information about the Life Extender option are shown if it’s active� Default: active�
Page 34
34
Main
Diagnostic
GSM
Modem
System
Main
Diagnostic
GSM
Modem
System
User instructions
Item of main menu� It shows the general parameters of the amplifier�
Read-only screen� In addition to the parameters shown in the main screen, they are listed: efficiency [Eff�(%)]; total working time [Wtime(h)] and that of fans [WFans(h)]; in­put power [P�In�]; voltage [Vds] and total current RF [Itot]; maximum temperature [Temp�] and fan speed [FanSp(%)]� Press “MENU” to return to main menu�
Item of main menu� It shows the specific parameters of the RF section�
Read-only screen� The values of current [RF current(A)] and temperature [Temperatures(C)] of all RF modules are shown here� In addition to parameters displayed above, they are listed inlet temperature [Tenv� In(C)]; the outlet one [Tenv� Out(C)] and the RF max one [RF T�max(C)]� Press “MENU” to return to main menu�
Page 35
35
Main
Diagnostic
GSM
Modem
System
Main
Diagnostic
GSM
Modem
System
User instructions
Item of main menu� It shows the specific parameters of the Power Supply Units�
Read-only screen� The parameters of the power supplies for the RF section and for the electronics are shown here� They are listed: currents [PSU(A)]; voltages [PSU(V)]; tem­peratures [PSU(C)]; total current consumption [IDS Tot]; VDS [VDS(V)]; efficiency [EFF(%)] and Bias voltage [Vbias(V)]� VCC(V); +V1(V) and -V1(V) are for electronics� Press “MENU” to return to main menu�
Item of main menu� It shows the list of occurred and active alarms�
Read-only screen� The list is sorted by reverse chronological order� The last occurred alarm is displayed first� The letter “A” indicates that the alarm is still active� Rotate the encoder to scroll the list� Up to 17 active alarms are displayed contemporarely� Press the encoder to return to main menu�
Page 36
36
Main
Diagnostic
GSM
Modem
System
Main
Diagnostic
GSM
Modem
System
User instructions
Item of main menu� It shows the list of all occurred events�
Read-only screen� It shows the list of all occurred events sorted by reverse chronological order (last one at the top) but progressively numbered� Date and time of occurrence are displayed under each item� Rotate the encoder to scroll the list� Up to 80 events can be shown, the older ones are deleted from the list� Press the encoder to return to main menu�
Item of main menu� It allows to enter the password for users�
Select each digit of the number and rotate the encoder to increase/decrease the value� Press to confirm� The status bar with the most important commands is displayed at the bottom� Press “MENU” to return to main menu�
Page 37
37
Main
Diagnostic
GSM
Modem
System
Main
Diagnostic
GSM
Modem
System
User instructions
Item of main menu� It allows to set the password for users�
To prevent unauthorized use of the amplifier, the password must be set to a value diffe­rent by the default� Select each digit of the number and rotate the encoder to increase/ decrease the value� Press to confirm� Press “MENU” to return to main menu�
Item of main menu� It allows to set the password for users�
It allows to have a temporary password in case of lost� The “UNLOCK CODE” must be sended to Elenos Service, which will provide a “PASSWORD RECOVERY” to unlock the device� Enter the password within 24 hours and follow the pro­cedure for unlocking� It’ll be necessary choose and enter a new password for the users� Press “MENU” to return to main menu�
Page 38
38
Main
Diagnostic
GSM
Modem
System
Main
Diagnostic
GSM
Modem
System
Main
Diagnostic
GSM
Modem
System
User instructions
Item of main menu� It allows to enter into the submenu System�
“System config” and “System config1”� Items of submenu System� They allow to set the most important parameters�
“Temp U�” chooses between Celsius scale and Fahrenheit; [Show D�] set to “Always” shows the display also in Remote Mode; [PwOscChk] set to “True” protects the amplifier from power oscillations; [UPS T(W)] defines the Max Power Target in case of UPS; [Min T�Sen] is the min number of thermal probes that will be taken good; [Fwd Pwr Cal� (%)] is the adjusting for reading Fwd and Ref power; [SWR Foldback] sets the ROS protec­tion; [IPA Bias Tres�] sets the treshold of the Bias; [Refl�Pwr T�N�(10%)] if active sets the treshold of REF to 10% of Target Power, otherwise the value is in [Refl�Pwr T�Lev�(W)]; [PAbias (V)] sets the polarization value of RF amp modules; [Max Target Pwr (W)] is the upper limit for the target; [Min Level Fwd Pwr Fault (W)] works in AND with the “-3dB” alarm, depending on which one be active before� Press “MENU” to return�
Page 39
39
Main
Diagnostic
GSM
Modem
System
Main
Diagnostic
GSM
Modem
System
User instructions
Item of submenu System� It allows to set address and speed of serial ports RS485�
There are two serial ports, one on the front and one on the back (TC/TS connector)� They must be set depending on the configuration of the transmitter� Typical values are 115K for speede and 0 for addresses�
Item of submenu System� It allows to show firmware and protocol versions�
[Ver�Sw] indicated the version of firmware installed into the equipment, and [Ver�P�] is the protocol� In addition, [On air time] and [Fan work time] are displayed, both in format “hh:mm:ss”� Select and press “R” to reset the time relative to fan� Press “MENU” to return�
Page 40
40
Main
Diagnostic
GSM
Modem
System
Main
Diagnostic
GSM
Modem
System
User instructions
Item of submenu System� It allows to adjust system date and time�
The current date and time are displayed in the row referred [C:]� In addition, the day of the week is shown� Enter new values in the row below and press “SET” to confirm� Press “MENU” to return�
Item of submenu System� It allows to define the percentages of power target levels�
When the value of [Target Power Mode:] is “Fixed”, the amplifier will not reduce the tar­get power depending on time slots� To allow this, change it in “CLOCKED”� Four levels of power, corresponding to 100%; 75%, 50% and 25%, are available� By setting the power value of the level [100%], the remaining ones will be automatically calculated� Press “MENU” to return�
Page 41
41
100% 50%75% 25%
Main
Diagnostic
GSM
Modem
System
Main
Diagnostic
GSM
Modem
System
User instructions
Item of submenu System� It allows to set the levels for each time slot�
First select the day of the week, then choose the time slot to modify [0���23]� A full bar means 100%; a 2/3 of bar = 75%; 1/3 of bar = 50% and no bar means 25%� Rotate the encoder to increase / decrease the level and press to confirm� [Copy over next day:] set to “T” allows to save all the levels to the next day of the week� [Reset at default:] set to “T” permits to recall the factory presets� Press “MENU” to return�
Item of submenu System� It allows to enable / disable the alarms depending on events�
See also paragraph about alarm codes� See also paragraph about alarm codes� At the right of each alarm code [00���47] there is a bit that can be “0” or “1”� Set the bit to “0” for not having a SMS; to “1” for having it� Press “MENU” to return�
Page 42
42
Main
Diagnostic
GSM
Modem
System
Main
Diagnostic
GSM
Modem
System
User instructions
Item of submenu System� Read only screen, synoptic of enable and status of alarms�
The first section shows the enabled alarms (bit set to “1”), the second one displays which ones are active� If [SMS/PTSN StatusReady:] is “TRUE” it means that an event is active� When the reset of alarms is performed, its value become “FALSE” and remains so until a new event will be active� Press “MENU” to return�
Item of submenu System� It allows to customize the alarms�
Some parameters can be customized about their conditions of activation� Typical units of measurement are: temperatures (°C or °F), power (W) and current (A); [Max] and [Min] are their limits that can be modified� [Type] indicates which kind of con­dition will activate the alarm� The options to choose are: “UPPER”; “LOWER”; “INSIDE” and “OUTSIDE”� “T” or “F” in [En�] enables or disables the alarm�
Page 43
43
Main
Diagnostic
GSM
Modem
System
Main
Diagnostic
GSM
Modem
System
User instructions
Item of submenu System� It allows to set the delays of each alarm�
The values displayed in the previous step are proposed here again� In addition, for each alarm it can be set a delay after that it will be taken as active� The progress of delays can be monitored by watching the values of [Timer]� It’s still possible to enable / disable the alarms�
Item of submenu System� It allows to enable/disable the Life Extender algorithm�
[SerialNumber] is the serial number of the equipment and [Device Code] is the number to send to Elenos to obtain the [Activation/Deactivation Code]� [LIFE EXTENDER Status] shows if the algorithm is running or not� [Run Time(dd): Optimal] is the number of days of correct working; [Heavy:] is the amount of days of working in critical conditions� Press “MENU” to return�
Page 44
44
Main
Diagnostic
GSM
Modem
System
Main
Diagnostic
GSM
Modem
System
Main
Diagnostic
GSM
Modem
System
Main
Diagnostic
GSM
Modem
System
User instructions
Item of submenu System� It allows to access into the submenu GSM / MODEM�
[Field Strength (dBm)] indicates the intensity of GSM signal; [No mains SMS] if “TRUE” send an alarm message after [Delay (m)] minutes; [SMS FWD over 2/3] if “TRUE” send a message when the power becames more then 2/3 of the target� In addition, [Pager Id]; [StatId] and [String Id] are customizable� The last one is the name of the equipment� Up to 8 SIM Card can be called by the amplifier and for each one selected which type of message to send if “T”: [En�] = Global enabling; [Cmd] = Command; [Sts] = Status; [Glb] = Echoes of others SMS; [PC] = Text or digital message format� Press “MENU” to return�
Page 45
45
Main
Diagnostic
GSM
Modem
System
Main
Diagnostic
GSM
Modem
System
User instructions
Item of submenu System� It allows to display the Ethernet Board parameters and others�
[Ip Address]; [SubNet Mask] and [Gateway] are displayed to permit the connection by LAN� [DHCP Status] is “FALSE” when the dinamic address is disabled� [Battery STS] indica­tes the charge level of the backup battery� [Intern� RTC] if “FALSE” means that the internal clock isn’t used as the reference� [Reset:] if “T” restarts the board; [Pwr_on:] if “T” turns on the board; [IsThere:] if “F” means that the CPU works like if the board is absent� Press “MENU” to return�
Item of main menu� It allows to
[Uart 0 Info]; [Uart 1 Info]; [Uart 2 Info] and [SMS Diagnostic]� Items of submenu Diagnostic� Information about serial and GSM communications are arranged in four screens to per­mit the simple consultation of them�
Page 46
46
Main
Diagnostic
GSM
Modem
System
Main
Diagnostic
GSM
Modem
System
Main
Diagnostic
GSM
Modem
System
Main
Diagnostic
GSM
Modem
System
User instructions
The first screen shows the status of communication with the Hostlink Slave (Uart 0)� The second one shows data about the Terminal Monitor or the GSM modem (Uart 1)� The third one shows data about Power Supply Units (Uart 2)�
The last screen is specific for the modem parameters� The number of SMS correctly sent and received is displayed [Sent]/[Received]+[ok], together with the number of failures [Sent]/[Received]+[bad]� [Test send status SMS] set to “TRUE” forces the equipment to send a test message�
Press “MENU” to return to main menu�
Page 47
47
On Air
!
!
5�2 Alarms/Warnings/Status list
A task called “Alarms Managing” monitors all physical and logical quantities� Each of them is sampled and processed by a combinatorial network to evaluate if an alarm (or a warning) must be activated� This task and the ALC management have the same high priority for having a constant monitoring of the entire apparatus and intervene quickly� The last alarms occurred are stored in a list with the time and date of the occurrence� All events that may be occur are listed on next pages�
Alarm� An event of this type means that a malfunctioning is occurring and maintenance could be necessary� However, the apparatus will attempt to minimize the failure by itself applying suitable algorithms�
Warning� An event of this type means that a temporary irregu­lar condition is occurring� Normally, there isn’t an important failure and the ap­paratus will recover its functionality by itself applying suitable algorithms�
Status� An event of this type notifies the operating condition of the apparatus and doesn’t mean that a malfunctio­ning is occurring�
User instructions
Page 48
48 User instructions
Event Code Message Description
STATUS 000 CORRECT WORKING
No error� The apparatus is working correctly� The event “019 ON AIR” has an higher priority�
STATUS 001 SYSTEM RESET
The list of occurred alarms is under deleting process� Active ones aren’t deleted�
WARNING 002 EEPROM CHKSUM ERROR
The data stored in memory is no longer relia­ble� The apparatus will be restarted with de­fault parameters�
ALARM 003 BLOCKED
The apparatus is blocked after that five resto­re have been attempted� To restart it, a reset command is required�
STATUS 004 STOP
The apparatus is in StandBy mode with no acti­ve alarms, ready to work�
ALARM 005 -3dB CARRIER
The RF output power is less than half target po­wer since one minute during the start up or five seconds during the correct working�
ALARM 006 HIGH REF PWR
High reflected power is detected after that a “Three Block Out” recovery protection has been attempted�
ALARM 007 MIN 12V
The negative voltage reference is no longer re­liable� The apparatus attempts the “Three Block Out” recovery protection�
ALARM 008 RF AMP� FAULT
A failure is occurred in one or more RF amplifier modules�
WARNING 009 RF AMP� FAULT DERATING
As above, but the RF output power is reduced according to an algorithm�
WARNING 010 RF THERMAL DERATING
The temperature of one or more RF amplifier modules is been too high so that the RF output power is reduced according to an algorithm�
ALARM 011 RF OVER TEMPERATURE
The “RF THERMAL DERATING” failed and the ap­paratus attempts the “Three Block Out” recove­ry protection�
ALARM 012 PSU FAULT A PSU malfunction is occurring�
WARNING 013 PSU CURRENT DERATING
One or more PSU overloads are occurred so that the apparatus is reducing the RF power output according to an algorithm�
ALARM 014 PSU OVER CURRENT
The apparatus was shut down in a minute since the current derating didn’t decrease�
WARNING 015 PSU THERMAL DERATING
One or more PSU overheatings are occurred so that the apparatus is reducing the RF output power according to an algorithm�
ALARM 016 PSU OVER TEMPERATURE
The temperature of one or more PSU have been too high so that apparatus has been shut down�
ALARM 017 PSU COMM TIMEOUT
The RS485 internal bus dedicated to the com­munication between CPU and PSU isn’t working correctly�
STATUS 018 EXTERNAL INTERLOCK
The interlock circuit is open and the apparatus is blocked�
STATUS 019 ON AIR The apparatus works correctly�
STATUS 020 POWER UP RF output power increase is occurring�
STATUS 021 POWER DOWN RF output power decrease is occurring�
WARNING 022 PSU THERMAL DERATING/FAULT
One or more PSU are performing a thermal de­rating by reducing the current supplied�
WARNING 023 PSU LOW POWER
One or more PSU are in thermal derating so that the RF output power is reduced�
ALARM 024 PSU RF OFF
The RF section has been turned off so that the fans can quickly cool the apparatus�
STATUS 025 WORKING MODE COMBINED The apparatus works in a combined transmitter�
WARNING 026 SWR FOLDBACK
High reflected power has been detected so that the apparatus is adjusting the RF output power according to an algorithm�
STATUS 030 OVER 2/3 CARRIER
The RF output power is rising up to 2/3 of the target after which a “-3dB” alarm has occurred�
Page 49
49User instructions
Event Code Message Description
WARNING 034 TEMPERATURE SENSOR ERROR
If the thermal probes installed are more than one, it means the fault of one of these because its read value is significantly different from the expected one�
ALARM 035 PWR FORWARD OSCILLATION
RF output power oscillation is detected and the apparatus attempts the “Three Block Out” reco­very protection�
ALARM 036 THREE BLOCK OUT
The malfunction has not disappeared during the automatic protection time and the appara­tus was stopped�
WARNING 037 USER ENV TEMP OUT LIMIT
The user-defined environmental temperature limits in “User Alarms Data” have been excee­ded�
WARNING 038 USER RF TEMP OUT LIMIT
The user-defined RF temperature limits in “User Alarms Data” have been exceeded�
WARNING 039 USER PSU TEMP OUT LIMIT
The user-defined PSU temperature limits in “User Alarms Data” have been exceeded�
WARNING 040 USER RF CURRENT OUT LIMIT
The user-defined RF current limits in “User Alarms Data” have been exceeded�
WARNING 041 USER PSU CURRENT OUT LIMIT
The user-defined PSU current limits in “User Alarms Data” have been exceeded�
WARNING 042 USER FRW PWR OUT LIMIT
The user-defined RF forward power limits in “User Alarms Data” have been exceeded�
WARNING 043 USER RFL PWR OUT LIMIT
The user-defined RF reflected power limits in “User Alarms Data” have been exceeded�
ALARM 044 OUT PWR NOT VERIFIED
The RF output power measurement is not re­liable�
STATUS 045 UPS ACTIVE
The apparatus works by drawing current from the UPS�
ALARM 046 SHUNT COMM TIMEOUT
Internal serial communication timeout� The ap­paratus has stopped working�
WARNING 047 WARNING TEMPERATURE SENSOR
A thermal probe is unreliable and its reading is discarded�
ALARM 049 DRAIN VOLTAGE TOO LOW
VDS voltage too low� The amplifier section has been stopped and will remain so until the di­sappearance of the cause�
WARNING 050 OVER FRW PWR ERROR
An overshoot of RF output power respect to the target is occurred�
WARNING 051 PSU VOLTAGE DERATING One or more PSU are in voltage derating�
WARNING 052 PSU NET OVER VOLTAGE Mains voltage too high�
STATUS 053 PILOT PWR GOOD The RF input power level is correct�
WARNING 054 INCREASE PILOT PWR
The RF input power level is to low but not dan­gerous and must be increased�
WARNING 055 DECREASE PILOT PWR
The RF input power level is to high but not dangerous and should be decreased�
ALARM 056 BAD INPUT RF PROTECTION
RF input power level out of limit� The external modulator has been disconnected�
WARNING 059 BATTERY LOW
The CPU backup battery is low� In case of no mains, the clock will lose settings�
WARNING 060 REFERENCE VOLTAGE ERROR
The internal reference voltage is no longer re­liable and the measurements will be incorrect� Some wrong alarms or warnings could be sent�
WARNING 062
DRAIN VOLTAGE CONTROL ERROR
VDS voltage is more than 4V different from the expected value� The adjustment is fixed at the last valid value� It restarts when the difference becomes less than 4V�
WARNING 065 RTC FAULT
The clock says a wrong time and it isn’t possible to cerrect automatically� Some settings, such as “clock power target”, will not run correctly�
STATUS 066 RTC USER UPDATED The user has updated the internal clock�
STATUS 067 RTC AUTOMATIC RECOVERY
The apparatus has updated the internal clock automatically�
Page 50
50 User instructions
Page 51
51
+39532829965
PWR 10000 STS STS1
A
B
C
DEF G HIL
MN
O PQ RST U
VZ
J
Y
X
K
W
?
Alt Ctrl
E10000 ID 10 SMS String +39532829965 ON AIR FWD 10000 W REFL 0 W VDS 43.6V IDS 280.50A TEMPMAX 57.7C TEMPENV 38.9C
A
B
C
DEF G HIL
MN
O PQ RST U
VZ
J
Y
X
K
W
?
Alt Ctrl
User instructions
5�3 SMS list
With internal modem option (or an external telemetry provided of a GSM modem) it’s possible to send commands and receive the status of apparatus�
Syntax of command and status SMS are shown below�
See also the paragraph “User interface” for the settings relative to the user authorizations�
Commands�
Using a mobile, via GSM network, it’s possible to send commands to the apparatus (if a modem is installed inside it)�
Status�
The unit returns a response with the requested data� However, it always sends messages based on what is fixed by the user (see paragraph on SMS)�
Page 52
52
E10000X ID nn SMS String +39nnnnnnnnnn STBY No mains nn m NoAudio AudioOK nnn Signaling message FWD nnnnn W REFL nnnnn W VDS nn.nV IDS nnn.nnA TEMPMAX nn.nC TEMPENV nn.nC
E10000X ID nn SMS String +39nnnnnnnnnn
-3dB Alarm No mains nn m NoAudio AudioOK nnn Signaling message FWD nnnnn W REFL nnnnn W VDS nn.nV IDS nnn.nnA TEMPMAX nn.nC TEMPENV nn.nC
E10000X ID nn SMS String +39nnnnnnnnnn Set STBY [TRG]/[24hTRG]nnnnW SmsOver-2/3 OFF PwrAdj nnn% Ver n.nn-n.nn MaxPwr nnnnnW
E10000X ID nn SMS String +39nnnnnnnnnn Set STBY [TRG]/[24hTRG]nnnnW SmsOver-2/3 ON PwrAdj nn% Ver n.nn-n.nn MaxPwr nnnnnW
E10000X ID nn SMS String +39nnnnnnnnnn Set ON AIR [TRG]/[24hTRG]nnnnW SmsOver-2/3 OFF PwrAdj nn% Ver n.nn-n.nn MaxPwr nnnnnW
E10000X ID nn SMS String +39nnnnnnnnnn Set ON AIR [TRG]/[24hTRG]nnnnW SmsOver-2/3 ON PwrAdj nn% Ver n.nn-n.nn MaxPwr nnnnnW
User instructions
5.3.1 SMS commands (sending)
Command SMS String
Set the RF output power at nnnnn watts PWR nnnnn
Switch the unit to StandBy mode
STBY
OFF
Switch the unit to On Air mode ON
Status request STS
Reset request RES
Data setting request STS1
Force the RF output power to Clocked mode CLKP
Force the RF output power to Fixed mode FIXP
Disabling the phone number that sends this SMS of receiving alarms / status SMS SMSNO
The phone number n is not able to receive the alarm / status SMS SMSNO n
The phone number n is able to receive the alarm / status SMS SMSYES n
5.3.2 Status/alarm SMS (receiving) - examples
Page 53
53User instructions
Meaning of items in status SMS
String Meaning
E10000X ID nn Description of the apparatus with indication of the ID number
SMS String Customizable string of 10 characters
+39nnnnnnnnnn Telephone number that sent the last command
STBY / ON AIR Status of the apparatus� It can be StandBy (off) or On Air (on)
-3dB Alarm The apparatus is supplying half power or less�
Status Reply to an SMS status command
Command Acknowledge receipt (echo)
nnn Signaling message Cause of stop or most important signaling
FWD nnnnn W Forward power
REFL nnnnn W Reflected power
VDS nnn.nV Operating voltage of RF power amplifier section (VDS)
IDS nnn.nA Total current actually absorbed
TEMPMAX nnn.nC Max temperature between all internal thermal probes installed
TEMENV nnn.nC Environmental temperature
Set Information about settings
[TRG]/[24hTRG]nnnnnW Target power / max target power in Clocked PWR mode
SmsOver-2/3 ON/OFF The power supplied by the amplifier has risen to 2/3 of the target
PwrAdj nnn% Adjusting of forward power shown at display
Ver n.nn-n.nn Firmware and datamap release
MaxPwr nnnnnW Power homologation
Please note: The SMS sending is suspended for an hour when more than 5 SMS are sent in 5 minutes�
Page 54
54 User instructions
Page 55
55
5�4 External devices connectable
The apparatus may be connected to the following devices:
• LAN/PC
• ECHOS6 (Changeover)
• BNC Audio Matrix / XLR Audio Matrix
ECHOS6 (Changeover)
Audio Matrix (XLR/BNC)
LAN (Switch/Router)
PC
User instructions
Page 56
56
SWITCH
PC
E10000X
ETH CABLES
User instructions
5.4.1 Connecting to a LAN/PC
Connect the apparatus to PC via LAN using a switch or any other device such as a router� Also the direct connection between apparatus and PC is possible� See web connection manual for all details�
Page 57
57
Echos6 SE (Elenos Changeover)
Echos6 SE (Elenos Changeover)
Echos6 SE (Elenos Changeover)
Echos6 SE (Elenos Changeover)
Audio Matrix (BNC Version)
Audio Matrix (XLR Version)
Audio Matrix (BNC Version)
E10000X
E10000X
E10000X
E10000X
All cables are DB25 extension cordsAll cables are DB25 extension cordsAll cables are DB25 extension cordsAll cables are DB25 extension cords
User instructions
5.4.2 Connecting to a Changeover/Audio Matrix
In N+1 systems, the apparatus may be a transmitter or the reserve (the exciter and its connections aren’t shown)� Examples of connections between these devices are shown below�
Tx1 in a N+1 system
Reserve in a N+1 sy­stem
Reserve in a N+1 system with Audio Matrix
Reserve in a N+1 system with double Audio Matrix
Note: If the transmitter is not the #1, look at the Echos6 manual for the connector to use�
Page 58
58 User instructions
Page 59
59
WEB Interface
6 WEB interface
WEB interface
6 WEB interface �����������������������������������������������������������������������������������������������������������������������59
6.1 Remote control - first connection ������������������������������������������������������������������������������ 62
6.2 Accounts �����������������������������������������������������������������������������������������������������������������������63
6.2.1 Users management ��������������������������������������������������������������������������������������������� 64
6.0.1.1 Adding a new user/manager ��������������������������������������������������������������������� 65
6.0.1.2 Editing/deleting an existing account �������������������������������������������������������� 66
6.0.1.3 Editing the user’s preferences �������������������������������������������������������������������� 67
6.0.2 Profiles ������������������������������������������������������������������������������������������������������������������ 68
6.0.2.1 Reconfiguring the own account. ���������������������������������������������������������������� 68
6.1 System �������������������������������������������������������������������������������������������������������������������������� 69
6.1.1 System Settings ���������������������������������������������������������������������������������������������������70
6.1.1.1 Network �������������������������������������������������������������������������������������������������������� 70
6.1.1.2 Modules configuration ���������������������������������������������������������������������������������71
6.2 Events ���������������������������������������������������������������������������������������������������������������������������73
6.2.1 Events ��������������������������������������������������������������������������������������������������������������������74
6.2.1.1 Senders management ��������������������������������������������������������������������������������� 74
6.2.1.2 Sender SMS/email configuration ��������������������������������������������������������������� 75
6.2.1.3 Destinatios management ���������������������������������������������������������������������������76
6.2.1.4 Adding a new destination ��������������������������������������������������������������������������77
6.2.1.5 Profiles management ���������������������������������������������������������������������������������� 78
6.2.1.6 Selecting the events to add to profiles �����������������������������������������������������79
6.2.1.7 Destinations profile management ������������������������������������������������������������� 80
6.3 RTC/UTC ������������������������������������������������������������������������������������������������������������������������ 81
6.3.1 Clock Settings ������������������������������������������������������������������������������������������������������� 82
6.3.1.1 Choosing between external and internal RTC ������������������������������������������� 83
6.3.1.2 Choosing a NTP server ��������������������������������������������������������������������������������� 84
6.3.1.3 Adding a new NTP server ����������������������������������������������������������������������������85
6.3.1.4 Choosing the Timezone ������������������������������������������������������������������������������� 86
6.4 User interface ��������������������������������������������������������������������������������������������������������������� 87
6.4.1 Telemetry �������������������������������������������������������������������������������������������������������������88
6.4.1.1 RF Power Amplifier �������������������������������������������������������������������������������������� 88
6.4.1.2 Power Supply Units (PSU) ��������������������������������������������������������������������������� 89
6.4.1.3 Profiles ���������������������������������������������������������������������������������������������������������� 90
6.4.1.4 Editing profiles ��������������������������������������������������������������������������������������������� 91
6.4.1.5 User Alarms �������������������������������������������������������������������������������������������������� 92
6.4.1.6 Transmitter info �������������������������������������������������������������������������������������������� 93
6.4.2 Events ��������������������������������������������������������������������������������������������������������������������94
6.4.2.1 Active alarms.����������������������������������������������������������������������������������������������� 94
6.4.2.2 Events history ����������������������������������������������������������������������������������������������� 95
6.4.2.3 Inbond SMS ��������������������������������������������������������������������������������������������������� 96
6.4.3 Control Centre������������������������������������������������������������������������������������������������������� 97
6.4.3.1 Energy Profiles. ��������������������������������������������������������������������������������������������97
6.4.3.2 Editing an Energy Profiles ��������������������������������������������������������������������������� 99
6.4.3.3 Energy Cost Profiles �����������������������������������������������������������������������������������100
6.4.3.4 Editing an Energy Cost Profiles �����������������������������������������������������������������101
6.4.3.5 Editing an Energy Band Cost ��������������������������������������������������������������������� 102
Page 60
60 WEB interface
Page 61
61
WEB Interface Overview
To create, delete, modify user accounts and edit them preferences�
To edit network interface and manage the installed modules�
To view and set all parameters of the equipment�
To manage user profiles regarding events and them notifications�
To choose and set the time reference�
WEB interface
WEB Interface Overview
Page 62
62
10�0�0�138
!
!
WEB interface
6�1 Remote control - first connection
Connect a PC to LAN or directly to the equipment by an Ethernet cable, start a browser and enter the default IP address: 10�0�0�138�
Note: if the screen shown below doesn’t appear, please check the IP address in “Chatty board config” as indicated in the Quick Start or in the User Manual�
Sign in and continue as shown below�
Default Username: admin Default Password: adminadmin
Note: the first connection must be performed by the administrator in order to define the user accounts and their respective levels of authorization�
Default Username and Password must be redefined by the administrator�
The length of Username must be (characters): 5 (min) 15 (Max) The length of Password must be (characters): 5 (min) 15 (Max)
Only uppercase, lowercase, numbers and symbols “-” and “_” for Username� Any character is valid for the password�
Page 63
63WEB interface
6�2 Accounts
Overwiev
User management� To create, delete, modify user accounts and edit them preferences in according to respective authorization levels�
Adding a new user� For each one they must be indicated username, email, role, phone number and password� The administrator can add and delete users�
Modifying the properties of the user ac­counts�
Modifying the users preferences�
Page 64
64
(Config)
Account
(Edit)
(Preferences)
(Add)
(Delete)
10�0�0�138
10�0�0�138
6.2.1 Users management
To create, delete and modify user accounts�
WEB interface
In the main screen, first select the “Config” button, then the “Users” button in the “Ac­count” bar�
Select “Add” to insert a new user/manager; “Edit” to modify an existing one, or “Prefe­rences” to edit his parameters� “Delete” button removes the current record from the list after confirmation� See next pages for more details�
Page 65
65
(Save)
(Cancel)
Introduction to the web interface operation.
10�0�0�138
WEB interface
For each new user/manager must be inserted the following items:
• Username (required) ��� (5 min) to ��� (15 max)
• Email (required) Any valid e-mail address
• Role (required) Selectable via the menu
• Phone number (optional) Any valid international phone number
• Password (required) ��� (5 min) to ��� (15 max)
• Password confirmation (required) Like above
Press the “Save” button to confirm or the “Cancel” button to abort the operation�
HIERARCHICAL CRITERION
3 authorization levels are available:
• User, who can access the screens in read-only mode;
• Manager, who can access the screens also in write mode but only for the equipments assigned to him;
• Administrator, who can also create accounts; modify the Ethernet network parame­ters, the Hostlink and SNMP ones if present�
Users (accounts) can edit the their own password and preferences�
6.0.1.1 Adding a new user/manager
After selecting the type of user to be added as shown on the previous page, the following screen is shown�
Page 66
66
(Save)
(Cancel)
!
10�0�0�138
Ignore
OK
10�0�0�138
WEB interface
6.0.1.2 Editing/deleting an existing account
All users, managers and administrators can change their own password� The rest of para­meters can be edited only by members with higher levels of authorization�
The value of fields can be modified in according to a valid format� To not changing the password, leave blank the field “Password”� Press the “Save” button to confirm or the “Cancel” button to abort the operation�
To delete an account, after selected “Delete” button, choose “Ok”� To abort the operation, press the “Ignore” button� WARNING: the account will be permanently deleted!
Page 67
67
(Save)
(Cancel)
(Config)
Account
10�0�0�138
10�0�0�138
WEB interface
6.0.1.3 Editing the user’s preferences
Some parameters of the users are customizable�
For each one it’s possible to choose the scale of temperature, the format of telephone number and the language of messages� Press the “Save” button to confirm or the “Cancel” button to abort the operation�
The user’s preferences editor is available also via pressing “Preferences” button in the “Account” bar�
Page 68
68
(Config)
Account
10�0�0�138
(Save)
(Cancel)
10�0�0�138
WEB interface
6.0.2 Profiles
6.0.2.1 Reconfiguring the own account.
Each user is authorized to change parameters of the own account, such as Password or Username�
To hold the password leave blank its field� Fields marked with an asterisk are required� The email address must be written in a valid format� Press the “Save” button to confirm or the “Cancel” button to abort the operation�
Page 69
69WEB interface
6�1 System
Overwiev
Network interface parameters�
Installed modules configuration�
Page 70
70
!
10�0�0�138
10�0�0�138
10.0.0.138
(Config)
System settings
(Save)
(Cancel)
WEB interface
6.1.1 System Settings
6.1.1.1 Network
Network parameters and internal configuration of equipment (optional boards installed)�
First select the “Config” button, then the “Network” button in the “System settings” bar� IP address, Netmask and Gateway are here editable� Only the local network administrator is authorized to change this data�
The factory default is: 10�0�0�138 - 255�255�255�0 - 10�0�0�1� In this screen it’s also possi­ble to enter additional non-mandatory information on the LAN (Network and Broadcast )� Press the “Save” button to confirm or the “Cancel” button to abort the operation� When the address is changed the connection must be restarted with the new one�
Page 71
71
10�0�0�138
(Config)
System settings
(Turn off)
(Start)
(Stop)
(Reboot)
!
10�0�0�138
WEB interface
6.1.1.2 Modules configuration
The equipment may be provided in basic configuration or with optional modules� The list of modules displayed depends on the specific configuration�
For their managing, first select the “Config” button, then the “Modules configuration” button in the “System settings” bar�
Basic set of the equipment includes Telemetry and Webserver modules� The first one is composed by hardware and firmware� Hardware can be rebooted and turned off; firmware (Telemetry agent) cab be started, stopped and rebooted� The second one may only be rebooted� WARNING: by turning off the telemetry the website will stop working�
Page 72
72 WEB interface
Page 73
73
6�2 Events
Overwiev
Senders configuration� The equipment may send both SMS and email�
Destinations management� They are the email addresses or the phone numbers of who receive the messages�
Profiles management� It allows to customize the information set to send to the destinations�
Page 74
74
10�0�0�138
(Config)
Events
10�0�0�138
(Enable/Disable)
(Edit)
(Avatar Opt)
WEB interface
6.2.1 Events
6.2.1.1 Senders management
The equipment can send/receive SMS and send email�
In the main screen, first select the “Config” button, then the “Senders” button in the “Events” bar�
The “Avatar Opt” button allows to enable/disable the use of the Avatar equipment (op­tional)� Press “Enable/Disable” button to select which one sender may be active� The “Edit” button gets into the mask for editing the sender’s data�
Page 75
75
(Save)
(Cancel)
(Enable)
(Disable)
(Save)
(Cancel)
(Enable)
(Disable)
10�0�0�138
10�0�0�138
WEB interface
6.2.1.2 Sender SMS/email configuration
If the equipment must send SMS, press the “Edit” button in the “SMS” bar� The following editing mask will appear�
“Device id” is the name that will be wrote in the message sent; “From” is the telephone number (modem)� The “Enable” button activates this feature; the “Disable” one deacti­vates it� Press the “Save” button to confirm or the “Cancel” button to abort the operation�
To allows sending emails, this mask must be completed by the network administrator with all required parameters� The “Enable” button activates this feature; the “Disable” one deactivates it� Press the “Save” button to confirm or the “Cancel” button to abort the operation�
Page 76
76
10�0�0�138
(Config)
Events
10�0�0�138
(Add)
6.2.1.3 Destinatios management
Destinations are the receivers of SMS and/or email sent by the equipment�
In the main screen, first select the “Config” button, then the “Destinations” button in the “Events” bar�
This section allows to relate senders with receivers of SMS and/or email� Initially the list is void, but new records can be added by authorized users� Press “Add” button to get into the editing mask�
WEB interface
Page 77
77
(Save)
(Cancel)
(Enable)
(Disable)
(Save)
(Cancel)
(Enable)
(Disable)
10�0�0�138
10�0�0�138
6.2.1.4 Adding a new destination
Editing destination mask� The contents may be different depending on the kind of sender selected�
A destination is a mobile number which receives the messages sent by the equipment� In addition, the owner’s name can be entered in the “Description” field� Press the “Save” button to confirm or the “Cancel” button to abort the operation�
Case in which the destination is an email address�
WEB interface
Page 78
78
(Config)
Events
10�0�0�138
(Add)
(Enable/Disable)
(Edit)
(Destinations)
10�0�0�138
WEB interface
6.2.1.5 Profiles management
Profiles of event lists which will be sent to the destinations in case of occurrence�
In the main screen, first select the “Config” button, then the “Profile” button in the “Events” bar�
Initially the list has only one profile named “Default” which contains all the possible events� This one can be customized and saved with the changes, however it’s preferable to add new ones by giving them mnemonic names to identify their scope more quickly� See also next pages for further information�
Page 79
79
10�0�0�138
(Undo)
(Select all)
(Clear selection)
(Save)
(Selected)
(Unselected)
WEB interface
6.2.1.6 Selecting the events to add to profiles
Events (“Default” profile in the example)�
All events are grouped in four classes:
• Alerts (critical errors or failures that may require repair);
• Warnings (events that don’t require repair immediately);
• Defaults (equipment current status);
• Successes (most important targets);
To customize the current profile (its name is shown at the top) select/unselect the events to combine to the destination� By default all events are deselected� Press one time an event button to add it to the pro­file, press again to remove it� It’s also possible select all events by pressing the “Select all” button, or deselect all by “Clear selection” one� “Undo” button restores the profile and “Save” confirms the changes�
Page 80
80
10�0�0�138
(Enabled)
(Disabled)
6.2.1.7 Destinations profile management
After selecting “Destination” button at the previous screen, the list of available destina­tions appears, both for SMS and email�
For each profile it’s possible to choose which destinations to enable� More destinations can be added to the same profile�
WEB interface
Page 81
81
6�3 RTC/UTC
Overwiev
Clock settings� It’s possible to choose between the in­ternal time reference (Real Time Clock) and the global one (Coordinated Univer­sal Time)�
Page 82
82
Clock settings
(Config)
XIIXII
VIVI
IXIX
IIIIII
SUN
(Local Mode)
(Remote Mode)
NOTE
10�0�0�138
WEB interface
6.3.1 Clock Settings
Selecting the time reference
In the main screen, first select the “Config” button, then the “Clock Settings” button in the “Clock settings” bar�
It’s possible to choose if using the internal clock or an external one as system time refe­rence� By the external clock the system receives the time from a preset list of public NTP server� To properly display date and time it’s necessary to select the appropriate timezone from the list of those ones available�Obviously, an internet connection is required� For using the internal clock, it will must be manually adjusted, both in Local and in Remo­te mode (see the User Manual for the last one)�
UTC (Coordinated Universal Time)
External RTC
RTC (Real Time Clock)
Internal Clock
Page 83
83
(Internal RTC)
(External RTC)
(Restore)
(Apply)
(Changes)
10�0�0�138
10�0�0�138
WEB interface
6.3.1.1 Choosing between external and internal RTC
Selectable buttons are highlighted in blue�
Press “External RTC” or “Internal RTC” button to toggle between the two modes�
If the choice results in a change, the button turns orange and a confirmation is requested� “Restore” button allows to ignore the changes, while “Apply changes” confirms them�
Page 84
84
(NTP Servers)
(Add)
(Enable/Disable)
(Edit)
(Delete)
10�0�0�138
10�0�0�138
WEB interface
6.3.1.2 Choosing a NTP server
A list of default NTP servers is stored in factory�
Press the “NTP server” button to enter and scroll through the list�
The “Add” button allows to insert a new NTP server (see next page)� Press the “Enable/Disable” button to activate/deactivate the selected server (when the symbol ““ is shown and the button is green the server is active)� The “Edit” button allows to modify the server parameters, while by pressing “Delete” button the current record will be removed after confirmation�
Page 85
85
(Enabled)
(Disabled)
(Save)
(Cancel)
(Timezones)
10�0�0�138
10�0�0�138
WEB interface
6.3.1.3 Adding a new NTP server
A new NTP server can be added to the list�
To define a new server it’s necessary enter its name (“Server name”) correctly� It’s also possible to enable/disable it� The “Save” button allows to store the new server, while by pressing the “Cancel” button the current operation is aborted�
To complete the setting of the external RTC, it’s necessary choosing a proper time zone� Press the “Timezones” button to enter and scroll through the list�
Page 86
86
10�0�0�138
(Save)
(Cancel)
!
Europe/Lisbon
10�0�0�138
WEB interface
6.3.1.4 Choosing the Timezone
A complete list of timezones is stored in factory�
A popup containing all the timezones is available after pressing the down arrow shown at the right side of the box�
Press “Save” button to store the changes, “Cancel” to restore all values�
WARNING: in order to ensure that all automatisms will work correctly, choose the timezo­ne of the country in which the equipment is installed�
Page 87
87WEB interface
6�4 User interface
Overwiev
Telemetry� Viewing and settings of all equipment parameters grouped by type�
Events� All kind of information about the wor­king state, grouped by warning level�
Control Centre� Interface for the full managing of the equipment�
Page 88
88
10�0�0�138
(Settings)
Telemetry
10�0�0�138
WEB interface
6.4.1 Telemetry
6.4.1.1 RF Power Amplifier
In the main screen, first select the “Settings” button, then the “RF power amplifier” but­ton in the “Telemetry” bar�
Temperatures, currents, voltages and powers of RF modules and power supplier units are shown in this screen, with statistics about functioning�
Page 89
89
10�0�0�138
(Settings)
Telemetry
WEB interface
6.4.1.2 Power Supply Units (PSU)
All parameters and statistics about main and service PSUs
In the main screen, first select the “Settings” button, then the “Power supply” button in the “Telemetry” bar�
In this screen are grouped all parameters of power supply units, specifically about the device consumption� Estimates of daily, weekly, monthly and yearly consumptions are shown too�
Page 90
90
10�0�0�138
(Settings)
Telemetry
(Edit)
WEB interface
6.4.1.3 Profiles
Power levels at which the equipment must work when it’ll be a reserve transmitter�
In the main screen, first select the “Settings” button, then the “Profiles” button in the “Telemetry” bar�
At the bottom of the screen there is a bar named “Target Power (W)” that displays 6 va­lues of power� They indicate the profiles to which the equipment could be set� Press the “Edit” buttons to change the targets�
Page 91
91
(Restore)
(Apply)
(Edit)
WEB interface
Press the local “Edit” button and write a new value in the field�
“Restore” button allows to ignore the changes, while “Apply changes” confirms them�
6.4.1.4 Editing profiles
Power levels at which the equipment must work when it’ll be a reserve transmitter�
Page 92
92
10�0�0�138
(Settings)
Telemetry
(Edit)
6.4.1.5 User Alarms
User defined alarms�
In the main screen, first select the “Settings” button, then the “User alarms” button in the “Telemetry” bar�
Some alarms may be customized, such as about currents and temperatures� Each user can define ranges and working logic of the alarms� After setting the “Limit Min” and “Limit max” values, choose the “Limit type”� Case “Upper” send the alarm when the parameters value are higher than upper limits; case “Lower” at the opposite� “Inside” or “Outside” when values are beetwen limits or out of them�
WEB interface
Page 93
93
(Settings)
Telemetry
10�0�0�138
WEB interface
6.4.1.6 Transmitter info
General data about the equipment�
In the main screen, first select the “Settings” button, then the “Transmitter info” button in the “Telemetry” bar�
Information about RF output power, software and hardware installed are shown here�
Page 94
94
10�0�0�138
(Settings)
Events
(Reset events)
6.4.2 Events
6.4.2.1 Active alarms.
In the main screen, first select the “Settings” button, then the “Active” button in the “Events” bar�
In this screen the active events are displayed� Status (events that don’t require interven­tion by user) are shown in blue boxes� Press “Reset events” button to clear the list�
WEB interface
Page 95
95
(Settings)
Events
10�0�0�138
(Previous)
(Next)(Top)
(Bottom)
(Download)
(Update)
(Delete current)
(Delete All)
6.4.2.2 Events history
List of occurred events�
WEB interface
In the main screen, first select the “Settings” button, then the “History” button in the “Events” bar�
The events are sorted in reverse chronological order, so that the latest ones are imme­diately visible� It’s possible scroll the pages with the navigation keys, update the list, remove individual warnings or clear the entire list� By pressing “Download” button, a “csv” format file, con­taining the entire list, is written in the default download folder�
Page 96
96
10�0�0�138
(Previous)
(Next)(Top)
(Bottom)
(Refresh)
6.4.2.3 Inbond SMS
List of received SMS�
In the main screen, first select the “Settings” button, then the “Inbound SMS” button in the “Events” bar�
The list of commands received via SMS is shown in this screen, to update it press the “Refresh” button� To scroll the messages use the navigation keys�
WEB interface
Page 97
97
10�0�0�138
(Settings)
Control Centre
(Enabled)
(Disabled)
(Save)
(Show)
WEB interface
6.4.3 Control Centre
6.4.3.1 Energy Profiles.
In the main screen, first select the “Settings” button, then the “Energy profiles” button in the “Control Centre ” bar�
It’s possible select, edit, add, delete or compare profiles� In addition, the preview of inactive profiles may be shown and the the “Fixed Target Power” mode can be enable/ disabled� Please, look at the next page for the complete screen and details about features�
Page 98
98
(Rename)
(Show)
(Delete)
(Edit)
(Apply)
“Energy Profiles” full screen�
A generic profile is stored in memory by factory� It may be edited and duplicated by the “Save as” option (see next paragraph) to obtain a new profile�
• By pressing the “Rename” button it’s possible to give a new name to an existing pro­file, without any other changes� If it was the active one, it will remain active�
• By pressing the “Delete” button the selected profile will be permanently removed from memory� It’s impossible to remove an active profile�
• The “Edit” button enters into the screen shown at next paragraph and allows to rede­fine an existing profile� Changes will be automatically applied�
• By pressing the “Apply” button the selected profile will be activated�
• The “Show” button allows to see an inactive profile overview on the top of the screen (green boxes matrix)� To change the day of the week, press the corresponding button on the overlying bar�
Note that the value of “Delta cost” field changes automatically when a non-active profile is selected (but not activated by the “Apply” button)� It allows to evaluate the difference of cost between the active profile and the selected one (see “Comparison” diagrams at the bottom of the screen)�
WEB interface
Page 99
99
(Save as)
(Save)
!
6.4.3.2 Editing an Energy Profile
Example of a complete weekly profile list�
WEB interface
After pressing the “Edit” button, a sinoptik square containing the entire profile matrix appears� All days of the week are subdivided in time slots of an hour each one� Four power levels are available: 100%, 75%, 50 and 25% of the target� They are selecta­ble by pressing on the green squares� An active level is highlighted by a black border (in the screen shown above they are all set at 100%)�
After changes, press the “Save” button to store the current profile, or “Save as” to me­morize a new profile� In the second case, the new profile will maintain the changes and the old one will not be modified�
Page 100
100
10�0�0�138
(Settings)
Control Centre
WEB interface
6.4.3.3 Energy Cost Profiles
List of Energy Cost Profiles�
In the main screen, first select the “Settings” button, then the “Energy Cost Profiles” but­ton in the “Control Centre” bar�
Overview of an “Energy Cost Profile”� The complete screen is displayed in the next page�
Loading...