Incorporated with advanced leak detect technology, WJL-6000
with the functions of easy operation, stable function and small appearance, it's
ideal and economic halogen leak detector.
Information:
is
our new product
Features:
Detect all kinds of halogen refrigerants.
Sensitivity adjusted at any time and it can be adjusted automatically to the
best state of detecting.
Inner precise
battery time.
Two-color visual display of battery voltage.
Excellent sensor, high sensitivity, longer use time.
IC
with Ultra-Low consume circuit design, more stable, longer
Structure:
1.
Sensing tip
2.
Flexible probe
3.
Indicator light
4.
Buzzer
5.
Power on/off and
sensitivity adjusting faucet
6. Battery compartment
7.
Shell
an
_1_
Page 3
· · · · ·
·GERMANY
TECHNOLOGY
lEAK-DETECT
EXPERT·
· · · · ·
Battery
The forepart light of panel indicates the leak and the battery voltage.
Green
Reset
WJL-6000 features
ignore ambient concentrations of Halogen.
Reset: Upon initial power
level
detecting. If place the sensing tip near a known leak and switch the unit
it's convenient to find higher concentration leak. Or move to fresh air and
witch on,adjust to maximum sensitivity,any concentration above zero will be
detected .
Automatic-circuit: When
the changing concentration of halogen gas
alarm.
Adjustment
The unit features vari-speed sensitvity adjustment and can be adjusted during
the course of detecting.Ciockwise adjusting means high sensitivity and
reverse means low.
It does not mean,when to select, the higher sensitivity
unit will work, because if the air
an
Voltage
- Battery voltage
- Battery voltage
replace as soon as possible.
Indication:
is
normal, sufficient for proper operation.
is
Feature/Automatic
on
automatic circuit and a reset function that set the unit to
of
refrigerant present at the tip
of
sensitivity:
improper alarm.
approaching the lower threshold for operation,
Circuit:
on
, the unit automatically sets itself to ignore the
in
6's and enter into the best state of
in
the measuring state, automatic circuit will follow
in
environment to avoid false
is
adjusted,the better the
is
not fresh,selecting higher sensitivity will cause
on
in
,
s-
Leak
When the leaked gas
sound. More refrigerant, more siren. At the same time, Indicator light
quickly.
alarm:
is
detected , the audible tone will change to a "siren" type
_2_
is
flashing
Page 4
· · · · ·
·OERMIINY
TECHNOLOGY
lEAK-DETECT
EXPERT·
· · · · ·
Operating
Switch the unit
Verify the battery voltage level by observing the power indicator.
Adjust appropriate sensitivity, or adjust the sensitivity at any time during
operation. This adjustment will not interrupt detection.
To
detect 6's later after the unit is switched on.
When refrigerant is detected, the buzzer will change to a "siren" type sound.
Verify the place of siren and detect continuously until the leak is confirmed.
Operating
Adjust to the higher sensitivity, when a leak can't be found. Adjust to the lower
sensitivity when unstable.
When the buzzer alarms for leak, if the sensing tip remained at the part being
detected long enough,the circuit will equalize
In
windy areas, even a large leak
is better to shield the potential leak area.
Be
aware that the detector may alarm if the sensing tip contacts with moisture
and/or solvents. Therefore, avoid contact with these when leak checking.
Recommended
Note:
The air conditioning or refrigeration system should
refrigerant to have a gauge, pressure of at least 340 kpa (50 psi) when not
operation. At temperatures below 15'C(59'F),
since this pressure may not be reached. "'-
Take
contaminated. If the part is particularly dirty, or condensate( moisture)
sent, it should
No cleaners or solvents should be used, since the detector may
to their Ingredients.
Instructions:
on
and discontinuous buzzer will be heard.
tips:
it.
is
difficult to
Procedure
On
Automotive A!C Systems leak test with the engine not
care not to contaminate the detector probe tip if the part being tested is
be
wiped off with a dry shop towel or blown off with shop air.
:
be
found. Under this condition it
in
operation.
be
charged with sufficient j
leaks
may
not
be
measurable, J
be
sensitive
is
in
pre-
_3_
Page 5
· · · · ·
Automotive
All
·BERMIINY
Visually trace the entire refrigerant system, and look for signs of air condition-
ing lubricant leakage , damage, and corrosion
onents. Each questionable area should be carefully checked with the detector
probe, as well as all fittings, hose to line couplings, refrigerant controls, service ports with caps
chment points and hold-downs
Always follow the refrigerant system around
of
areas
the remainder
At each area checked, the probe should be moved around the location, at a
rate no more than 25 to 50 mm/second(1-2in/second) . And no more than
5mm(1/4in) from the surface, completely around the position. Slower and
closer movement of the probe greatly improves the likelihood of finding a
leak.
An
a) Blow shop air into the area of the suspected leak, if necessary ,and repeat
b) First move the probe to fresh air and reset. Then hold the probe tip
Leak testing of the evaporator core while
be accomplished by turning the air conditioning blower on high for a
period
to accumulate
deteclor probe into the blower resistor block or condensate drain hole, if no
water
conditioning case to the evaporator, such as the heater duct or vent duct. If
the detector alarms, a leak apparently has been found.
Systems:
Following any service to the refrigerant systems and any other servi
disturbs the refrigerant system, a leak test
ports of the retrigerant system should
potential leaks are missed. If a leak is found, always continue to test
apparent leak shall
the check of the area.
shop air often helps locate the exact position
as possible to the indicated leak source and slowly move around it until the
leak
is
confirmed.
A/C
of
15seconds minimum, shutting it off, then waiting for the refrigerant
is
present, or into the closet opening
TECHNOLOGY
in
place, brazed or welded areas, and areas around atta-
on
of
the system.
be
verified at least once
In
case of very large leaks, blowing out the area with
Systems
in
the case of 10 minutes. After such time, insert the leak
only-
lEAK-DETECT
on
all lines. Hose, and comp-
lines and components.
in
a continuous path so that no
as
follows:
of
the leak.
in
the air conditioning module shall
in
the heating/ventilation/air
of
the repair and of the servi
be
done.
EXPERT·
as
ce
· · · · ·
close
whi
ch
ce
_4
_
Page 6
· · · · ·
·GERMANY
TECHNOLOIIY
lEAK-DETECT
EXPERT·
Applications:
The
WJL-6000
Detect leaks
to All halogenated (contains Chlorine and Fluorine) refrigerants. This
includes, but
detect the halogenated carrier gas).
Detect SF-6
Detect most gases that contain chlorine, Fluorine and Bromine(halogen
gases).
Detect cleaning agents used
perchloroethylene.
Detects halogen gases
may also
in
other systems and storage/recovery containers. It will respond
is
in
high voltage circuit breakers.
be
used to:
not limited to:
R11
,R500,R503 etc
in
fire-extinguishing system.
..
.
..
.
in
hospital sterilizing equipment (it will
in
dry cleaning applications such as
Maintenance:
Appropriate maintenance of your leak detector
following the instructions to reduce the mal-operation and prolong the life
expectancy of the unit
Keep the sensing tip clean from the dust, moisture and grease.
is
dirty
it
If the tip itself
as alcohol, for several seconds, and then using compressed air and/or a
towel to clean. Never use solvents such as gasoline, turpentine, minerals etc.
for they will leave detectable residue and desensitize your unit.
Warning:turn the tool off before replacing the sensing tip. Failure to do
may result in a mild electric shock!
Sensing tip replacement: the tip will eventually wear out and require replace-
ment.
It
is difficult to predict exactly when this will occur since tip longevity is
directly related to the conditions and frequency
replaced whenever the alarm sounds or becomes erratic
environment.
can be cleaned by immersing
is
very important. Carefully
in
a mild solvent, such
of
use. The tip should be
in
a clean and pure
· · · · ·
so
_5_
Page 7
······GERMANY
TECHNOLOGY
lEAK-DETECT
EXPERT······
Take out the batteries
If the tool does not work please inspect whether the batteries are
connnection or the voltage
inspect whether the tip
Your part of opening the tool is beyond the warranty service.
Specifications
Operating temperature: OOC to 52°C (30°F to 125r )
Maximum sensitivity: 6 gr/yr, for all halogenated refrigerants.
Battery life: Approximately
Response time: Instantaneous.
Work mode: Continuous, no limitation.
Fixed Probe Length:20cm.
Unit Dimensions:22.9cm x 6.5cm x 6.5cm.
Warm-up time: Approximately 6 seconds.
Reset Time: Two to ten seconds.
Power Supply: 6V
in
case of long time of no-use.
is
below acceptable operating level. If not, please
is
dirty and
and
parameter:
50
DC
four cell 7# excellent batteries.
in
a stable connection with the probe.
hours normal use.
Warranty:
Should any problems arise
purchase , a no-charge repair or replacement will be offered to the original
purchasers.
The warranty applies to all repairable instruments that have not been tamp-
ered with or damaged through improper use.
Make sure that you have reviewed the maintenance part of this manual to
see if the problem can be solved before returning it for repair.
in
the operation within one year from the date of
in
a stable
_6_
Page 8
······GERMANY
TECHNOLOGY
lEAK-DETECT
EXPERT······