General
Incorporated with advanced leak detect technology, WJL-6000
with the functions of easy operation, stable function and small appearance, it's
ideal and economic halogen leak detector.
Information:
is
our new product
Features:
Detect all kinds of halogen refrigerants.
Sensitivity adjusted at any time and it can be adjusted automatically to the
best state of detecting.
Inner precise
battery time.
Two-color visual display of battery voltage.
Excellent sensor, high sensitivity, longer use time.
IC
with Ultra-Low consume circuit design, more stable, longer
Structure:
1.
Sensing tip
2.
Flexible probe
3.
Indicator light
4.
Buzzer
5.
Power on/off and
sensitivity adjusting faucet
6. Battery compartment
7.
Shell
an
_1_
![](/html/6a/6a84/6a848c80a3a5dbaab252f045d1371d44b1fd723889280f76227870792d1c83d6/bg3.png)
· · · · ·
·GERMANY
TECHNOLOGY
lEAK-DETECT
EXPERT·
· · · · ·
Battery
The forepart light of panel indicates the leak and the battery voltage.
Green
Reset
WJL-6000 features
ignore ambient concentrations of Halogen.
Reset: Upon initial power
level
detecting. If place the sensing tip near a known leak and switch the unit
it's convenient to find higher concentration leak. Or move to fresh air and
witch on,adjust to maximum sensitivity,any concentration above zero will be
detected .
Automatic-circuit: When
the changing concentration of halogen gas
alarm.
Adjustment
The unit features vari-speed sensitvity adjustment and can be adjusted during
the course of detecting.Ciockwise adjusting means high sensitivity and
reverse means low.
It does not mean,when to select, the higher sensitivity
unit will work, because if the air
an
Voltage
- Battery voltage
- Battery voltage
replace as soon as possible.
Indication:
is
normal, sufficient for proper operation.
is
Feature/Automatic
on
automatic circuit and a reset function that set the unit to
of
refrigerant present at the tip
of
sensitivity:
improper alarm.
approaching the lower threshold for operation,
Circuit:
on
, the unit automatically sets itself to ignore the
in
6's and enter into the best state of
in
the measuring state, automatic circuit will follow
in
environment to avoid false
is
adjusted,the better the
is
not fresh,selecting higher sensitivity will cause
on
in
,
s-
Leak
When the leaked gas
sound. More refrigerant, more siren. At the same time, Indicator light
quickly.
alarm:
is
detected , the audible tone will change to a "siren" type
_2_
is
flashing