HOT GLASS WILL Une surface vitrée chaude
CAUSE BURNS. peut causer des brûlures.
DO NOT TOUCH GLASS Laisser refroidir la surface
UNTIL COOLED. vitrée avant d’y toucher.
NEVER ALLOW CHILDREN Ne permettez jamais á un enfant
TO TOUCH GLASS. de toucher la surface vitrée.
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed
for the protection of children and other at-risk individuals.
Une barrière conçu pour réduire le risque de brûlure par le verre de visualisation chaude est fournie avec cet appareil et doit
être installé pour la protection des enfants et autres personnes à risque.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could
result in serious injury, death, or property damage.
- Do not store or use gasoline or other ammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
• If you cannot reach your gas supplier, call
the re department.
- Installation and service must be performed
by a qualied installer, service agency or the
gas supplier.
AVERTISSEMENT:
INCENDIE OU D’EXPLOSION
Le non-respect des avertissements de sécurité à la
lettre pourrait entraîner de graves blessures , la mort
ou des dommages matériels.
- Ne pas entreposer ni utilizer d’essence ni d’autres vapeurs
ou liquides inammables dans le voisinage de cet appareil
ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ
• Ne pas tenter d’allumer d’appareil.
• Ne touchez á aucan interrupteur. Ne pas vous servir des
téléphones se trouvant dans le bátiment ou vous trouvez.
• Quitter immédiatement le bâtiment.
• Appelez immédiatment votre fournisseur de gaz depuis
un voisin. Suivez les instructions du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz
appelez le service des incindies.
- Installation et l’entretien doivent être eectués par un
installateur qualié, une agence de service ou le fournisseur
de gaz.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
INSTALLATEUR: Laissez cette notice avec l’appareil.
CONSOMMATEUR: Conservez cette notice pour
consultation ultérieure.
1
4006 611
January 2020
Page 2
Page 3
TABLE OF CONTENTS
Important Safety Information ............................................................................................. 4
Massachusetts Certication.......................................................................Appendix One
Troubleshooting ...........................................................................................Appendix Two
Connecting To A Smart Home System ................................................Appendix Three
Installing the Optional Black Glass .........................................................Appendix Four
Error Codes.. ....................................................................................................Appendix Five
Page 4
IMPORTANT SAFETY INFORMATION
CAUTION - HOT! HOT! HOT!
This appliance is a HEATING appliance and it does become very hot in operation.
UNDER ANY CIRCUMSTANCES, DO NOT PLACE any object, furniture, draperies or other item LESS THAN 36” (90 cm) IN
FRONT OF THE GLASS OF THE FIREPLACE.
CHILDREN AND PETS
Radiant heat can heat surfaces such as the surround and trims of the replace to temperatures that, although approved
safe, can be quite uncomfortable to touch - particularly for children and pets. Children and pets should always be
supervised when in the room where the appliance is located. Remote control handset should be kept out of reach of
children. In the presence of children, we STRONGLY RECOMMEND that you install in front of the replace: a re screen or,
to protect young toddlers, a “hearth gate”.
HOT SURFACES
Be aware that, although safe, some combustible materials and nishes, even though
installed at listed clearances may, over time, discolor, warp or show cracks.
Convective heat will exit the unit and travel up the wall surface if not impeded. Protruding
mantels and projections can help direct the heat away from the wall. AVOID placing heat
sensitive items such as televisions, paintings, decorations, etc. above replaces or near the
edge of protrusions unless appropriate.
Do not place furniture or other objects
within 36” of the replace glass.
SAVE THESE INSTRUCTIONS
Make yourself fully aware of all the following instructions and the many features of the Element4
direct vent gas replace appliance.
INSTALLER: Leave this manual with the appliance.
OWNER: Keep this manual for future reference.
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
4
Page 5
IMPORTANT SAFETY INFORMATION
WARNING
Children and adults should be alerted to the hazards of
high surface temperature and should stay away to avoid
burns or clothing ignition.
WARNING
This direct vent system appliance must be installed as an
OEM installation in manufactured homes (USA only) or
an aftermarket permanently located, or a mobile home,
where not prohibited by local codes and must be
installed in accordance with Manufacturer’s instructions
and the Manufactured Home Construction and Safety
Standard, Title 24 CFR, Part 3280, in the United States, or
the Standard for Installation in Mobile Homes, CAN/CSA
Z240 MH Series, in Canada.
If the information in these instructions is not followed
exactly a re or explosion may result causing property
damage, personal injury or death.
Do not store or use gasoline or other ammable vapors
and liquids in the vicinity of this appliance.
WARNING: Installation and Service
Installation and service must be performed by an
authorized qualied installer, service agency or gas
supplier.
Any alteration to the product that causes soot or carbon to
form and results in damage is not the responsibility of the
manufacturer.
ONLY a qualied person may open the door/remove the
glass.
Do not modify or substitute any part of this appliance.
WARNING: Electrical Grounding
These direct vent appliances must be electrically
grounded in accordance with the local codes or, in the
absence of local codes, with National Electric code, ANSI/
NFPA 70, or the Canadian Electric Code, CSA C22.1
WARNING: Gas Supply Testing
This appliance and its appliance main gas valve must be
disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of
½ psi (3.5 kPa).
This appliance must be isolated from the gas supply piping
system by closing the equipment shuto valve during any
pressure testing of the gas supply piping system at test
pressures equal to or less than ½ psi (3.5 kPa).
WARNING: Glass Handling
The glass must only be removed by a qualied person.
Gloves should be worn when removing the glass.
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
This appliance is only for use with the type of gas
indicated on the rating plate. These appliances are not
convertible for use with other gases unless a certied kit
is used and the conversion is performed by an authorized
qualied technician.
Applicable standards are ANSI Z21.50/CSA 2.22 (Vented
Gas Fireplaces) and CAN/CGA 2.17-M91 (Gas-red
Appliances for Use at High Altitudes.) If your installation
is at an elevation greater than 2000’ in the US or 4500’
in Canada, consult with the local authority having
jurisdiction for gas product installations to determine their
specic requirements for high altitude installations.
5
WARNING: Gas Appliance
Page 6
IMPORTANT SAFETY INFORMATION
This gas replace and vent assembly MUST be vented
directly to the outside and MUST NEVER be attached to a
chimney serving a separate solid fuel burning appliance.
Each gas appliance MUST BE a separate vent system.
Common vent systems are prohibited.
This unit MUST be used with a vent system as described
in this installation manual. NO OTHER VENT SYSTEM OR
COMPONENTS MAY BE USED.
INSPECT the external vent cap on a regular basis to make
sure that no debris, plants, trees, or shrubs are interfering
with the air ow.
This appliance is for indoor use only.
TURN OFF the gas before servicing the appliance. It is
recommended that a qualied service technician perform
an appliance check-up/service once a year.
Any safety screen or guard removed for servicing MUST BE
REPLACED before operating this appliance.
THIS UNIT IS NOT FOR USE WITH SOLID FUEL, and must
only be used with gas supply conditions as indicated on
the rating label.
DO NOT USE this appliance if any part has been under
water. Immediately call a qualied service technician to
inspect the unit and to replace any part of the control
system and any gas control that has been under water.
NEVER OBSTRUCT the ow of ventilation air. Keep the
front of the appliance CLEAR of all obstacles and materials
for servicing and proper operation.
The glass panels MUST be in place and sealed before the
unit can be placed into safe operation.
DO NOT OPERATE this appliance with the glass panels
removed, cracked or broken. Replacement of the glass
panels should be performed by a licensed or qualied
service person. DO NOT strike or slam the glass panels.
The glass panels SHALL ONLY be replaced by units
supplied by the manufacturer. NO SUBSTITUTE panels
shall be used.
DO NOT USE abrasive cleaners on the panels. DO NOT
ATTEMPT to clean the glass panels when they are hot.
DO NOT use this appliance as a temporary source of heat
during construction.
This appliance is a vented gas replace. It must not be
used for any other purposes such as drying clothes, etc.
If the pilot ame is extinguished either intentionally or
unintentionally, no attempt should be made to re-light the
gas until at least 3 minutes have elapsed.
Dimensions will appear as INCHES”/metric throughout
this manual. For convenience, the inches are rounded to
the nearest 1/16” when converted. If greater accuracy is
required, use the metric dimensions.
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
6
Page 7
6
KEY INSTALLATION POINTS
IMPORTANT
INFORMATION
This page references the most important key installation points when installing any Element 4 replace. This
page DOES NOT substitute for reading the entire manual.
FRECORDS
The installer MUST record the serial number and venting conguration to use for any technical issues that
may arise.
FELECTRICAL
An approved 120V AC wall receptacle is required. The receiver MUST be powered by the AC adapter. Four
AA batteries may be used only for on-demand electrical requirement during power outage.
FFIRE MEDIA
When installing the re media make sure to NEVER mix dierent types of media or use media purchased
from another retailer. ALWAYS keep the second thermocouple AND pilot free from media.
FAIR OUTLETS
The warm air outlets MUST be installed BEFORE the rst light. The amount of square inches needed for the
opening varies from model to model.
FENCLOSING THE FIREPLACE
ONLY a tested and approved non-combustible wallboard that is specied in the manual may be used when
enclosing the replace.
FFRAMING
The dimensions are dierent between metal and wood framing. Know which material you are using and
know the framing requirements.
FVENTING
The venting MUST follow the model specic graph shown in the manual. A restrictor may or may not need
to be used based on venting run and rise.
FCONSTRUCTION DEBRIS
REMEMBER that if the replace is installed before the site is nished, construction debris MUST be cleaned
from the enclosure and around the unit prior to nishing and the test re.
FGAS PRESSURES
Gas pressures MUST be read with a manometer and conrmed with what is required in the installation
manual.
FFINISHING
A ⁄” (3 mm) gap between the ange and the enclosing wallboard MUST be maintained to prevent cracking
from heat expansion and contraction.
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
7
Page 8
PLANNING YOUR GAS FIREPLACE
PLANNING YOUR GAS FIREPLACE
Before You Begin
• Since the Element4 replaces are vented gas appliances they must be installed by a qualied installer.
Your sales representative can help you choose the appropriate professional.
Overall Design
• One of the many features of the Element4 replace is its use of convective air ow.
• As the air within the enclosing walls, or chase, is warmed by the replace it rises and then exits the
Convection Air Outlet(s). The warm air in the chase is then replaced by room air which enters through
the Room Air Inlets. As this warm air cools it falls toward the oor where it’s drawn into the inlet and the
cycle repeats.
• The Room Air Inlets are part of the replace and cannot be blocked or adjusted. The amount of square
area required for your Convection Air Outlet(s) is determined by the replace model and is listed in the
installation manual.
• As seen in the illustrations, below, the outlets may be placed in a number of locations to accommodate
all types of designs. In all cases, though, your design must allow the free ow of air through the chase.
Convection Air Outlets
near ceiling showing
warm air ow.
Half-wall conguration
with Convection Air
Outlet set into top.
Convection Air
Outlets set into
bottom of reveal.
Convection Air
Outlets set on
side walls.
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
8
Page 9
PLANNING YOUR GAS FIREPLACE
PLANNING YOUR GAS FIREPLACE
Important Points
help you today!
PLANNING YOUR GAS FIREPLACE
30 Log Bridge Road
Building 300 - Suite 303
Middleton, Ma 01949
www.EuropeanHome.com
Important Points
• The most important question to ask when locating your replace is, “Can it be eectively vented?”The Element4 replaces are approved as “direct vent” appliances. This means that all of the air for combustion comes directly from the outside and all of the ue gases are discharged directly to the outside by way of co-axial 5” x 8” direct vent pipe.
• The venting can run vertically, horizontally or a combination of both. For example, it can be installed near and vented through an exterior wall. Or it can be installed near the center of your home and vented through the roof. In any case, the installation manual details the allowable congurations, distances and clearances. If the venting falls outside of the vent graphs, a power vent is available.
• The next question to ask is, “Can I get my gas pipe to the replace?”The Element4 replaces burn either natural gas (NG) or propane gas (LP.) Your sales representative will ask you for your requirement at the time of order and your gas professional (usually your plumber) can advise you on the most eective route for the gas supply within your home.
• In order to keep the look as contemporary as possible the replace controls are mounted away from the replace but within a radius of approximately 50” (1250 mm) from center of the replace (on most mod-els). These controls are attached to the frame behind an access door (included) which measures 8 3/8”(213 mm) by 11 1/4” (285 mm) overall. This access door is then mounted in your wall lower than the level of the replace opening, outside the combustible zone, or insulated from the heat of the replace. Your design must take this access door into consideration.
• This sheet is not intended to replace the Element4 Installation Manual. In all cases, the information and instructions in the Element4 Installation Manual must be followed. The Element4 Installation Manual is included with your replace and is available at www.europeanhome.com Please call us if you have any questions or are uncertain about any aspect of your installation!
Let Us Help
• European Home and its retail partners are here to assist you with your unique replace design. Let us help you today!
• The most important question to ask when locating your replace is, “Can it be eectively vented?” The
Element4 replaces are approved as “direct vent” appliances. This means that all of the air for combustion
comes directly from the outside and all of the ue gases are discharged directly to the outside by way of
co-axial 5” x 8” direct vent pipe.
• The venting can run vertically, horizontally or a combination of both. For example, it can be installed
near and vented through an exterior wall. Or it can be installed near the center of your home and vented
through the roof. In any case, the installation manual details the allowable congurations, distances and
clearances. If the venting falls outside of the vent graphs, a power vent is available.
• The next question to ask is, “Can I get my gas pipe to the replace?” The Element4 replaces burn either
natural gas (NG) or propane gas (LP.) Your sales representative will ask you for your requirement at the
time of order and your gas professional (usually your plumber) can advise you on the most eective
route for the gas supply within your home.
• In order to keep the look as contemporary as possible the replace controls are mounted away from the
replace but within a radius of approximately 50” (1250 mm) from center of the replace (on most models). These controls are attached to the frame behind an access door (included) which measures 8 3/8”
(213 mm) by 11 1/4” (285 mm) overall. This access door is then mounted in your wall lower than the level
of the replace opening, outside the combustible zone, or insulated from the heat of the replace. Your
design must take this access door into consideration.
• This sheet is not intended to replace the Element4 Installation Manual. In all cases, the information and
instructions in the Element4 Installation Manual must be followed. The Element4 Installation Manual is
included with your replace and is available at www.europeanhome.com Please call us if you have any
questions or are uncertain about any aspect of your installation!
Let Us Help
• European Home and its retail partners are here to assist you with your unique replace design. Let us
Call our Technical Team if you have any Questions:
781-324-8383 x. 502
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
9
Page 10
USER INFORMATION
WARMTH AND BEAUTY HOW IT WORKS
The Element4 replaces are direct vent replaces and, as such, the intake and exhaust are both handled through the vent pipe. The
replace also provides convection air to your room. The illustration shows one of the unique features of the Element4 replaces - its
use of warm, convection air ow.
Other replaces have louvered metal boxes around them to keep temperatures under control. The Element4 replaces use your
enclosing walls, or chase, to guide this warm air.
When the air within the chase is warmed by the replace, it exits through an air outlet that you have provided. This chase air is then
replaced by room air which enters through the Air Inlet (provided by the replace design) and through the Wall Access Door. As the
exiting warm air cools, it falls to the oor where it's drawn into the inlets and the cycle repeats.
The replace provides the inlet for room air as part of its design; you provide the warm air outlet as part of your design.
See the ENCLOSING the FIREPLACE section of this manual for more information.
Warm Air Out
Room Air In
Warm Air Out
Site-built Chase
Room Air In
Access Door
Room Air In
Figure 1
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
10
Page 11
8LL
APPLIANCE RATINGS
ModelAll Club 240H Series
GasNatural GasPropane
Input MaximumBtu/hr88,00064,800
Input MinimumBtu/hr26,00019,500
Inlet Pressure
SPECIFICATIONS and DIMENSIONS
in. w.c.711
kpa1.742.74
Manifold Pressure
Main Burner Injector Marking1400560
Pilot Injector Marking31.227.1
Eciency80.6%
Figure 2
in. w.c.3.410.6
kpa0.852.64
AC ADAPTER SPECIFICATIONS
Input Voltage120V AC
Input Power9 W
Output Voltage6V DC
Output Current500 mA
Size3.1”H x 2”W x 1.7”D
Output Cord Length6 Feet
Agency ApprovalsUL, CSA
Figure 4
Figure 3
This product was tested and listed to
ANSI Z21.11.50a-2008 and CSA2.22a-2008
“Vented Gas Fireplaces” by Intertek Group.
(Figure 3)
A sample listing label image is shown
above. A metal listing label is attached
to every Element4 replace and contains
important certication information. The
listing label must not be removed from
24V POWER SUPPLY
SPECIFICATIONS
Input Voltage120V AC
Input Power120W
Output Voltage24V DC
Size 1.7”H x 4”W x 6.25”D
Output Cord Length3 Feet
Agency ApprovalsCE, FCC
Figure 6
Figure 5: AC Adapter Connection
Figure 7: 24V Power Supply
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
11
Page 12
SPECIFICATIONS and DIMENSIONS
manufactured by
Element4 B.V.
Modore 240H Cut Sheet
01/2020
EuropeanHome
distributed by
CLUB 240H F
LETTERABCDEGHIKLM
INCHES
[MILLIMETERS]
Figure 8
94 ¼
[2395]
21 ⁄
[550]
8 ⁄
[205]
107 ⁄
[2721]
37 ¾
[959]
77 ⁄
[1960]
16 ⁄
[423]8[204]6[152]
13 ⁄
[336]½[13]
CLUB 240H F
(Vent can be ordered on either side)
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
Unit Weight
Pounds Kilograms
551250
CLUB 240H T
A downloadable DWG le is available at www.europeanhome.com for dimensions not shown.
15
Page 16
SPECIFICATIONS and DIMENSIONS
PARTS OF THE FIREPLACE
The various parts of the Club 240 RD replace are shown below. These parts are typical of any Element4 Club 240 replace.
1212
1111
66
11
W
22
77
44
55
99
33
1010
Figure 12
Table of Fireplace Parts
Outer Frame Face - surrounds the glass panels and limits the non-combustible wall board
1
Exterior Glass Panel(s) - quantity varies by model
2
Support Feet - four adjustable feet allow the replace to be levelled
3
Hearth Panel - supports various Fire Media
4
Primary Burner - produces the ame
5
Flange
6
Pilot Burner - the part of the safety circuit which lights the Main Burner
7
2nd Thermocouple - the part of the safety circuit which monitors the Main Burner
8
Finish Trim - hides the Glass Clamps
9
Glass Gaskets - hidden, holds the Glass Panel in place (quantity varies by model)
10
Vent Collar - accepts the included North American Venting Adapter
11
Relief Door - part of the safety system. Do NOT block the operation.
12
Pilot Assembly
13
Upright Trim - quantity varies by model
14
Figure 13
1414
88
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
16
Page 17
SPECIFICATIONS and DIMENSIONS
33
33
Figure 14: Fireplace from below
Table of Fireplace Parts
Outer Frame Face - surrounds the glass panels and limits the non-combustible wall board
1
Exterior Glass Panel(s) - quantity varies by model
2
33
1313
33
Support Feet - four adjustable feet allow the replace to be levelled
3
Hearth Panel - supports various Fire Media
4
Primary Burner - produces the ame
5
Flange
6
Pilot Burner - the part of the safety circuit which lights the Main Burner
7
2nd Thermocouple - the part of the safety circuit which monitors the Main Burner
8
Finish Trim - hides the Glass Clamps
9
Glass Rope Gaskets - holds the Glass Panel in place (quantity varies by model)
10
Vent Collar - accepts the 5” x 8” venting adapter (included)
11
Relief Door - part of the safety system. Do NOT block the operation.
12
Pilot Assembly
13
Upright Trim - quantity varies by model
14
Figure 15
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
17
Page 18
15
These are NOT zero-clearance fireplaces. All clearances to
combustible AND non- combustible materials MUST be maintained
as described in this manual.
LOCATING THE FIREPLACE
When selecting a location for the replace:
• Ensure that all minimum clearances to combustible AND noncombustible materials are met.
• Provide adequate clearances for servicing.
• Consider venting dimensions (rise, run and number of
elbows, etc.) when selecting the location for your replace.
• Locate the appliance out of trac and away from furniture
and draperies.
• Keep the location free of electrical, plumbing or other
heating/air conditioning ducting.
CLEARANCES
bottom of the feet.
MINIMUM CLEARANCE TO COMBUSTIBLES
• The appliance is approved with a minimum clearance to
combustible materials of 26” (660 mm) to the top, 11” (280
mm) on all sides and 4” (100 mm) to the bottom. Any spacer
or framing used closer than this dimension must be noncombustible (e.g. metal).
• The minimum distance from the bottom of the appliance to
the room ceiling is 72” (1830 mm).
• When installing the venting, the following clearances to
combustible materials MUST be maintained:
a. 3” (76 mm)above any horizontal venting
b. 1” (25 mm)to venting sides or below any horizontal
venting
PLACING THE FIREPLACE
The base upon which the appliance rests (Figure __) must be sturdy,
level and built to safely support at least 800 pounds (363 kilograms).
The base may be the oor or a purpose-built raised platform, e.g.
wood, metal. When placed on a platform, an 8” (203 mm) x 6” (152
mm) opening must be cut through the platform top. The lineset
can be routed through this opening. Room air must be allowed
to ow through the Wall Access Door then through this platform
opening.
Figure 16
The feet on the appliance are designed to sit on a at platform,
however the appliance must not be installed on any combustible
material other than wood. For example, carpet or linoleum bases
are not permitted.
• Do not block or restrict the Air Inlet, located between the
stando frame and glass.
The minimum clearances (air spaces) to combustible materials
must be maintained. It is of the greatest importance that the
replace and vent system be installed only in accordance with
these instructions.
Clearance to combustibles summary:
Back: 11” (280 mm)
The Floor dimension (above) is measured from the bottom of
the rebox. When the adjustable feet are in their lowest position
the required clearance to the oor is maintained.
Do not place anything between the bottom of the rebox and the
ENSURE THAT THE LINESET (WHICH INCLUDES THE GAS ENSURE THAT THE LINESET (WHICH INCLUDES THE GAS
VALVE, ELECTRICAL WIRING, AND GAS LINES) DOES NOT VALVE, ELECTRICAL WIRING, AND GAS LINES) DOES NOT
IMPEDE THE FULL OPERATION OF THE RELIEF DOORS. IT IS IMPEDE THE FULL OPERATION OF THE RELIEF DOORS. IT IS
YOUR RESPONSIBILITY TO ENSURE THE SAFETY OF THESE YOUR RESPONSIBILITY TO ENSURE THE SAFETY OF THESE
CRITICAL COMPONENTS THROUGHOUT THE INSTALLATION CRITICAL COMPONENTS THROUGHOUT THE INSTALLATION
PROCESS. REMOVE AND DISPOSE OF ALL WRAPS AND TIES.PROCESS. REMOVE AND DISPOSE OF ALL WRAPS AND TIES.
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
18
Page 19
CLEARANCES
ALL MODELS
CLEARANCES TO COMBUSTIBLE MATERIAL
Clearances to Combustibles
Sides (Non-Glass Sides ONLY)11”
Top26”
Bottom4”
Figure 17
CLEARANCES TO NON-COMBUSTIBLEMATERIAL
Clearances to Non-Combustibles
Sides (Non-Glass Sides ONLY)2”
Top2”
Bottom4”
Figure 18
No material of any kind is allowed between the bottom of the support feet and the bottom of the rebox (except for the
lineset).
No material of any kind is allowed within 2” (50 mm) of the top of the replace.
No material of any kind is allowed within 2” (50 mm) of the metal sides the replace.
Facing material should be installed against the outer frame of the replace, with an ⁄” (3 mm) vertical or horizontal clearance
TO THE FLANGE to allow for heat expansion.
Non-combustible materials may be installed to a zero clearance to the outer faces of the appliance outer frame face. However,
they must not cover (or prevent the removal of) the glass panels or other replace parts.
The appliance must not be installed on any combustible material other than wood.
These clearances are the same for ALL Element 4 Fireplaces, regardless of model.
We recommend that the replace be set into its nal location before building the enclosure.
Please refer to the “Reduced Clearance to Existing Combustible Wall” section for use of combustibles inside of the above clearances.
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
19
Page 20
(2") 50
C
SECTION
A-A
900
COMBUSTIBLE MATERIALSNOT PERMITTED IN FRONTOF GLASS
17
CLEARANCES
MANTELS
The graph below shows a range of allowable depths and heights for a combustible mantel installation.
As shown, the minimum allowable mantel height above the replace opening is 2” (50 mm) with a 1” (25 mm) deep mantel.
The maximum mantel depth is 12” (300 mm) at a minimum height above the replace opening of 13” (330 mm.)
All of the mantel height/depth combinations fall in between these extremes in accordance with the chart below.
Mantels made of non-combustible material are allowed inside these dimensions but they will be subjected to elevated
temperatures and may become too hot to touch.
A typical completed installation with mantel is shown in the diagram below, on the right.
INCHES
13”/330 mm
Mantel Height
Figure 19Figure 20
Mantel Depth
12”/300 mm
1”/25 mm
2”/50 mm
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
20
Page 21
18
CLEARANCES
TYPICAL CLEARANCE DIAGRAMS
The total area of the air openings must be maintained. The location of the openings must allow for the free movement of air and
must not allow excessive warm air to build up within the chase.
The top of the Warm Air Outlet must be no more than 1” (25 mm) down from the chase ceiling.
The minimum distance from the bottom of the appliance to the room ceiling is 72” (1830 mm).
BB
Air Outlet
Figure 21
Minimum Distances
Room ceiling to
A
appliance bottom
Room ceiling to top of
B
Convection Air Outlet1”25 mm
Figure 22
72”
1830 mm
Model
Figure 23
A
Air Outlet Area by Model
Square
Inches
Any126813
Square
Centimeters
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
21
Page 22
IG
GAS and ELECTRIC
INSTALLING THE GAS LINE
In accordance with the latest edition of the National Fuel Gas Code, NFPA 54 (USA) or CAN/CSA-B149.1 (Canada,) correctly size and
route the gas supply line from the supply regulator to the area where the appliance is to be installed.
Never use galvanized or plastic pipe unless it is rated for use with gas. Gas supply pipes must be designed, routed, constructed and
made of materials that are in strict accordance with local codes and regulations. A qualied plumber or gas tter should be hired to
correctly size and route the gas supply line to the appliance in accordance with all applicable codes and regulations.
Installing a gas supply line from the fuel supply to the appliance involves numerous considerations of materials, protection, sizing,
locations, controls, pressure, sediment trap, and other criteria. The sizing and/or installing of gas piping should only be performed
by a qualied plumber or gastter.
The gas control inlet accepts a ⁄” NPT tting.
The gas supply piping should have a separate gas shuto valve and a capped, 1/8” pipe tapping upstream of the valve for the purpose
of reading pressure. A service shuto valve must be placed within six feet of the replace gas control valve.
The gas supply pressure at the gas control valve must not exceed the Maximum Supply Pressure as shown in the Specications and Dimensions section of this manual.
The gas supply line must be properly connected and bled by a certied gastter or plumber.
The appliance and its main gas valve must be disconnected from the gas supply piping system during any pressure testing of that
system at test pressures in excess of ½ psi (3.5 kPa). The appliance must be isolated from the gas supply piping system by closing
its equipment shuto valve during any pressure testing of the gas supply piping system at test pressures equal to or less than ½ psi
(3.5 kPa).
ELECTRICAL REQUIREMENTS
Two 120V AC receptacles are required for replace operation.
The Club 140 Series replaces use a mobile device app and/or remote control for their burner operation. The remote control comes
with two AAA batteries and its receiver is powered by a 120V AC adapter, included. The receiver MUST be powered by the AC
adapter. Four (4) AA batteries may be used for FLAME ONLY operation during a power outage. Remove batteries after use to avoid
battery corrosion. Battery corrosion will damage the receiver.
The LED lights and Wi-Fi Box are powered by a 24V power supply. The 24V power supply requires a 120V AC receptacle.
The installer must provide an approved 120V AC receptacle to be placed within the three foot cord limit of the 24V power supply.
Electrical work must be performed by a qualied, licensed electrician.
WARNING
All wiring shall be in compliance with all local, city, and state codes.
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
22
Page 23
20
VENTING
CONFIGURATION
CONFIGURING THE VENTING
The replaces in this manual are direct vent replaces that use a co-axial or “pipe within a pipe” venting system. The outer “pipe” or vent
conducts fresh, outside air into the replace and the inner vent carries the exhaust outside. This system, which can run either horizontally
through a side wall or vertically through the roof, produces an ecient system because conditioned building air is not used for combustion.
• Only the 5” x 8” direct vent components from the companies listed below (Figure __) are approved for use with
these replaces. Any of the 5” x 8” direct vent components suitable for the local condition are permitted. Please visit
www.europeanhome.com/qr-support or via the QR code below for installation instructions.
• This replace is shipped with a North American venting adapter (Figure__). It MUST attach to the
vent collar of the replace.
• All venting measurements are taken from the top center of the vent collar on the top of the replace
and all congurations must fall within the acceptable range of the venting charts.
• A minimum clearance of 3” (75mm)must be maintained between combustible materials and the top
of any horizontal vent pipe surface; a minimum clearance of 1” (25mm)must be maintained between
combustible materials and any other vent pipe surface.
• The horizontal parts of the venting must be pitched up away from the replace. For every 12” (305mm)of horizontal run, the
venting must rise ¼” (6.5mm)toward the termination. The venting must never run downward unless with the use of a power
vent.
• Whenever venting passes through a wall, an approved heat shield or ‘wall thimble’ must be installed.
• A power vent system is available for venting that falls outside of the venting graphs. Refer to the appropriate power vent
manual for any venting conguration which is outside of the vent graphs shown here.
• Your venting needs to be inspected annually, including any connected components, to ensure that the system is working as
designed.
24
25
Figure 24: North American Vent
Adapter
• In colder climate environments, the replace can be lowered to STANDY BY MODE (Pilot Flame only). This will help maintain a
steady draft within the venting over a period of up to ve days. See the “Operating the Fireplace” section.
APPROVED COMPONENTS and MANUFACTURERS
DirectVent Pro (M&G DuraVent, Inc.)
EXCELDirect (ICC - Industrial Chimney Company)
Pro-Form (BDM - Bernard Dalsin Manufacturing)
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
23
Page 24
VENTING
CONFIGURATION
S
S
Figure 26
R
R
N
N
T
N
S
N
N
T
S
Q
T
Figure 27
R
N
S
Figure 28
Vertical or Horizontal Vent TerminationR
45° or 90° (bends vertical to horizontal or vice versa)N
45° and 90° (bends horizontal to horizontal)Q
Horizontal Pipe SectionT
Vertical Pipe SectionS
Figure 29
CALCULATING THE TOTAL VERTICAL SECTION (TVS)
Calculate the Total Vertical Section by adding up all vertical (upward) sections in your vent design.
CALCULATING THE TOTAL HORIZONTAL SECTION (THS)
Calculate the Total Horizontal Section by adding up all horizontal sections in your vent design.
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
24
Page 25
VENTING
CONFIGURATION
BEWARE OF ELBOWS
Elbows create resistance to the movement of air through your venting conguration and they must be included when determining
your minimum and maximum vent lengths. There must be a minimum vertical rise of 20” (508mm) before any elbow.
Elbows are called either ‘vertical’ or ‘horizontal’ depending on their mounted position. The two types of elbows are:
TYPE N - 45° or 90° elbows which transition from vertical to horizontal and vice versa. This can be called an upright elbow.
TYPE Q - 45° or 90° elbows which transition from horizontal to horizontal. This can be called an at elbow.
No more than four 90° elbows OR eight 45° elbows OR a combination totaling no more than 360° ‘elbow degrees’ are allowed. For
example, a combination of two 90° elbows and two 45° elbows is allowed (90° + 90° + 45°+ 45° equals 270°) but a combination of
three 90° elbows and three 45° elbows is not allowed (the total equals 405°.)
APPLYING THE RESULTS
The rst (3) N elbows do not need to be included in venting calculations. For an elbow-degree count greater than 270°, the
following applies:
• for either Type N elbow you must add 40” (1m) to your THS
• for a 90° Ty pe Q elbow you must add 80” (2m) to your THS
• for each 45° Type Q elbow you must add 40” (1m) to your THS
Once you have found your total vertical section (TVS) and your total horizontal section (THS) plot the intersection of these two
numbers on the appropriate chart, below.
The intersecting block will have one of three entries; 0, 35, or X:
If your TVS and THS intersect at a block with an “0” the conguration is possible without a restrictor.
If your TVS and THS intersect at a block with an “35” the conguration is possible and a 35 mm restrictor must be used.
If your TVS and THS intersect at a block with an “X” the conguration is not possible.
For venting congurations that intersect at an “X” a power vent option may be available.
5050
INSTALLING A RESTRICTOR
Some vent congurations may require a restrictor plate be installed. The restrictor for this replace is installed on the inside top of
the replace and is to be slid open or closed. Loosen the screws on either side and slide the restrictor as desired. Do not modify the
restrictor(s). Please use the graph above to determine if you will need to use a restrictor.
Loosen these two Phillips head
screws to slide the restrictor on/o.
35 mm
Figure 30Figure 31
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
25
Page 26
VENTING
32'10" (10 m)
5050500000
29'7" (9 m)
505050505000
26'3" (8 m)
505050505000
23' (7 m)
505050505000
19'8" (6 m)
505050505000
16'5" (5 m)
50505050500x
13'2" (4 m)
5050505050xx
9'10" (3 m)
0000xxx
6'7" (2 m)
000xxxx
3'4" (1 m)
00xxxxx
1'8" (0.5 m)
xxxxxxx
ft. in. (meters)
0 - 1'7" 1'8" (0.5 m) 3'4" (1 m) 5' (1.5 m) 6'7" (2 m) 8'3" (2.5 m)9'10" (3 m)
32'10" (10 m)
5050500000
29'7"(9 m)
505050505000
26'3"(8 m)
505050505000
23' (7 m)
505050505000
19'8"(6 m)
505050505000
16'5"(5 m)
50505050500x
13'2"(4 m)
5050505050xx
9'10"(3 m)
0000xxx
6'7"(2 m)
000xxxx
3'4"(1 m)
00xxxxx
1'8"(0.5 m)
xxxxxxx
ft. in. (meters)
0 -1'7"1'8"(0.5 m)3'4"(1 m)5'(1.5 m)6'7"(2 m)8'3"(2.5 m)9'10"(3 m)
72'3" (22 m)
000xxx
68'11" (21 m)
5050000x
65'8" (20 m)
505050505050
62'5" (19 m)
505050505050
60' (18 m)
505050505050
55'10" (17 m)
505050505050
52'6" (16 m)
505050505050
49'3" (15 m)
505050505050
46' (14 m)
505050505050
42'8" (13 m)
505050505050
39'5" (12 m)
505050505050
36'2" (11 m)
505050505050
32'10" (10 m)
505050505050
29'7" (9 m)
505050505050
26'3" (8 m)
50505050500
23' (7 m)
50505050500
19'8" (6 m)
50505050500
16'5" (5 m)
50505050500
13'2" (4 m)
505050500x
9'10" (3 m)
0000xx
6'7" (2 m)
000xxx
3'4" (1 m)
00xxxx
ft. in. (meters)
0 - 1'7" 1'8" (0.5 m) 3'4" (1 m) 5' (1.5 m) 6'7" (2 m) 8'3" (2.5 m)
Horizontal Termination Allowed Venting and Restrictor Requirements
rise
run
Figure 32
Vertical Termination Allowed Venting and Restrictor Requirements
VENTING CHARTS
rise
run
Figure 33
KEY
configuration allowed, no restrictor required
configuration NOT allowed
Figure 34
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
26
Page 27
VENTING
HORIZONTAL VENT TERMINATION CLEARANCES AND REQUIREMENTS
Figure 35
CLEARANCES
Figure 36
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
27
Page 28
VENTING
CLEARANCES
VERTICAL TERMINATION CLEARANCES AND REQUIREMENTS
Important Note for Roof Terminations
These instructions should be used as a guideline and do not supersede local codes in any way. Install venting according to local
codes, these instructions, the current National Fuel Gas Code (ANSI Z223.1 in the USA) or the current standard of CAN/CSA-B149.1
in Canada.
Figure 37
A second termination may be no closer than 12”/305 mm.
Figure 39: Multiple Termination Clearance
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
Figure 38: Termination Heights
28
Page 29
26
ENCLOSING the FIREPLACE
COMBUSTIBLE MATERIALS
Materials that can catch re and burn are considered combustible. Any material that is made of, or faced with wood, wood pulp,
paper, plastic or any other material that can catch re and burn is considered combustible. Even though these materials may have
been ‘ame-proofed’, made ‘re-resistant’ or are ‘re-rated’ they are considered combustible. Standard and Type X drywall are
combustible.
NON-COMBUSTIBLE MATERIALS
A material is non-combustible when it cannot catch re and burn. For example, materials made of stone, brick, concrete, tile, steel,
plaster or glass are non-combustible.
The table below (Figure __) shows a list of materials which are reported by their manufacturers to be non-combustible (in accordance
with the ASTM E136 standard) AND approved for use around replaces.
Skamol Skamotec® 225 and the Promat PROMAFOUR® system are preferred products for enclosing replaces.
ProductThickness
Skamol Skamotec® 225 Fireplace Building Board1½” (38 mm)
Promat PROMAFOUR® System ½” (12 mm)
James Hardie Building Products HardieBacker® 500 ½” Cement Board ½” (12 mm)
James Hardie Building Products HardieBacker® ¼” Cement Board¼” (6 mm)
Figure 40: * The listed brand names are trademarks of their respective companies.
Skamol Americas, Inc.
(844) 475-2665
E-mail: [email protected]
www.skamotec225.com
40
Promat Inc.
(865) 681-0155
E-mail: [email protected]
www.promat.us/en
Fireplace Trim
James Hardie Building Products
(888) 542-7343
www.jameshardie.com
Figure 42
Minimum Wall Thickness =
½”/12 mm
Figure 41
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
29
Page 30
27
ENCLOSING the FIREPLACE
BUILDING THE ENCLOSURE/FRAMING
A safe installation of your Element4 replace requires that three things be clearly understood.
1. Most important, these replaces are NOT zero-clearance replaces. Unlike zero-clearance replaces, there is not an outer
metal box around the Element4 replaces which increases the framing dimensions.
2. Only the non-combustible wall around the glass, the platform (oor,) the mounting brackets and the venting may touch the
replace.
3. The controls will be mounted to your enclosure and below the burner. The controls are at the end of a line set and are to be
accessed via the Wall Access Door (included.) The controls must be located for ease of physical access (gas line, maintenance,
etc.) as well as wireless signal (remote control) access. See the LOCATING THE CONTROLS and the MOUNTING THE CONTROLS sections. The
Wall Access Door has a total opening of 25 in (161 cm through which air must pass into the chase.
It may seem straightforward to build the ‘rough opening’, set the replace then attach the wall. However, for most projects, it will be
easier to rst set the replace in position then enclose it with Skamol Skamotec® or Promat PROMAFOUR® building board.
REDUCED CLEARANCE TO EXISTING COMBUSTIBLE WALLS
When retrotting the replace against an existing wall it is often desirable to reduce the distance between the replace and the
combustible wall. Normally, this distance is 11” (280 mm) but it may be reduced by shielding the existing nished wall with a 1” (25mm)
air gap and a sheet of non-combustible material as shown on the following page.
IN ALL CASES:IN ALL CASES:
• A reduced clearance “wall protection shield” is ONLY ALLOWED ON A VERTICAL WALL; IT IS NOT ALLOWED TO BE USED ON • A reduced clearance “wall protection shield” is ONLY ALLOWED ON A VERTICAL WALL; IT IS NOT ALLOWED TO BE USED ON
HORIZONTAL OR ANGLED SURFACES WITHIN THE NON-COMBUSTIBLE ZONE.HORIZONTAL OR ANGLED SURFACES WITHIN THE NON-COMBUSTIBLE ZONE.
• The “wall protection shield” shall be placed no closer than 1” (25 mm) to the oor or any intersecting walls. Air MUST be allowed • The “wall protection shield” shall be placed no closer than 1” (25 mm) to the oor or any intersecting walls. Air MUST be allowed
to continually circulate around all sides of the wall shield.to continually circulate around all sides of the wall shield.
• A 1” (25 mm) air gap between the wall shield and the existing wall MUST be maintained. • A 1” (25 mm) air gap between the wall shield and the existing wall MUST be maintained.
• A 2” (50 mm) air gap between the wall shield and the replace MUST be maintained.• A 2” (50 mm) air gap between the wall shield and the replace MUST be maintained.
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
30
Page 31
ENCLOSING the FIREPLACE
REDUCED CLEARANCE TO EXISTING COMBUSTIBLE WALLS
COMBUSTIBLE WALL
COMBUSTIBLE WALL
SHIELD OVER FINISHED WALL
SHIELD OVER FINISHED WALL
Figure 43
COMBUSTIBLE WALL
SHIELD OVER FINISHED WALL
2” (50) 2” (50) mmmm
Minimum Air Minimum Air
Gap MUST BE Gap MUST BE
MAINTAINEDMAINTAINED
Figure 44
1” (25) 1” (25) mmmm Minimum Air Gap MUST BE MAINTAINED Minimum Air Gap MUST BE MAINTAINED
SHIELD OVER FINISHED WALL
COMBUSTIBLE WALL
Figure 45
Figure 46
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
31
Page 32
ENCLOSING the FIREPLACE
MINIMUM AREA REQUIRED FOR Club 240H F
Front stando frame against front wall
Letter Inches Millimeters
A18 ⁄475
B110 ⁄2802
C41 ⁄1064
Figure 47
When enclosing the Club 240H F replace there is a minimum clear area which must be maintained. Nothing except the Club 240H
F may be within this area. When enclosed, the Club 240H F is centered between the left and right enclosing walls. This minimum
area MUST BE DEFINED BY NON-COMBUSTIBLE MATERIAL. The inside of the enclosing walls (including any necessary framing) may be
no less than the distances (A, B and C) shown above.
Your installation will use more than this minimum cabinet space in order to accommodate controls, venting, air openings, etc. We
recommend that the replace be set into its nal location before building the enclosure.
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
32
Page 33
ENCLOSING the FIREPLACE
MINIMUM AREA REQUIRED FOR Club 240H C
Club 240H LC stando
frame against RIGHT wall
Club 240H RC stando
frame against LEFT wall
Front stando frame against front wall
Letter Inches Millimeters
A18 ⁄475
B110 ⁄2802
C41 ⁄1064
Figure 48
When enclosing the Club 240H C replace there is a minimum clear area which must be maintained. Nothing except the Club 240H
C may be within this area. When enclosed, the Club 240H RC is against the left wall or the Club 240H LC is against the right wall. This
minimum area MUST BE DEFINED BY NON- COMBUSTIBLE MATERIAL. The inside of the enclosing walls (including any necessary framing)
may be no less than the distances (A, B and C) shown above.
Your installation will use more than this minimum cabinet space in order to accommodate controls, venting, air openings, etc. We
recommend that the replace be set into its nal location before building the enclosure.
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
33
Page 34
SPECIFICATIONS and DIMENSIONS
MINIMUM AREA REQUIRED FOR Club 240H R
Side stando frame
against side wall
Rear stando frame against rear wall
Front stando frame against front wall
Letter Inches Millimeters
A17¼438
B110⁄2802
C41⁄1064
Figure 49
When enclosing the Club 240H R replace there is a minimum clear area which must be maintained. Nothing except the Club 240H
D may be within this area. When enclosed, the Club 240H R is against the side (short) wall. This minimum area MUST BE DEFINED BY NON-COMBUSTIBLE MATERIAL. The inside of the enclosing walls (including any necessary framing) may be no less than the distances
(A, B, C, D and E) shown above.
Your installation will use more than this minimum cabinet space in order to accommodate controls, venting, air openings, etc. We
recommend that the replace be set into its nal location before building the enclosure.
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
34
Page 35
SPECIFICATIONS and DIMENSIONS
MINIMUM AREA REQUIRED FOR Club 240H T
Side stando frame
against side wall
Rear stando frame against rear wall
Side stando frame
against side wall
Front stando frame against front wall
Letter Inches Millimeters
A17¼438
B113⁄2873
C41⁄1064
Figure 50
When enclosing the Club 240H T replace there is a minimum clear area which must be maintained. Nothing except the Club 240H
T may be within this area. When enclosed, the Club 240H T is centered between the left and right enclosing walls. This minimum
area MUST BE DEFINED BY NON-COMBUSTIBLE MATERIAL. The inside of the enclosing walls (including any necessary framing) may be
no less than the distances (A, B, C, D and E) shown above.
Your installation will use more than this minimum cabinet space in order to accommodate controls, venting, air openings, etc. We
recommend that the replace be set into its nal location before building the enclosure.
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
35
Page 36
ENCLOSING the FIREPLACE
Figure 51:
Club 240H F with Air
Outlets in Wall
Figure 53:
Club 240H C with
Air Outlets in Wall
Figure 52:
Club 240H F with Air
Outlet in Reveal
Figure 54:
Club 240H C with
Air Outlet in Reveal
Air Outlet Area by Model
Square
Model
Inches
All1261300
Square
Centimeters
Figure 55
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
36
Page 37
ENCLOSING the FIREPLACE
DO NOT ALLOW THE FIREPLACE
TO BEAR ANY WEIGHT
Dimensions A, B, and C must be equal throughout the installation.
Any support framing (NON-combustible framing ONLY) must be at least 2” (50 mm) away
from any part of the replace. The entire weight of the non-combustible walls must be borne
by a structure other than the replace.
AABBCC
Figure 56
Use the adjustable feet to ensure that the replace is level prior to enclosing it.
Do NOT lift the replace by the face frame but by the bottom of the cabinet.
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
37
Page 38
ENCLOSING the FIREPLACE
COLD CLIMATE INSULATION
For cold climate installations, it is especially important to insulate outside the chase cavity, between studs and under the oor on
which appliance rests, if oor is above ground level. Gas line holes and other openings should be lled with approved restop.
If the replace is being installed on a cement slab in cold climates, a sheet of plywood or a raised platform can be placed underneath
to prevent cold transferring to the replace and into the room. It also helps to tape the venting for maximum air tightness and to
caulk the restops.
LOCATING THE CONTROLS
The standard control system consists of four major components; the receiver, the remote control, the gas valve, and the power
supply.
The remote control is the device by which you operate the replace. The receiver and the gas control are at one end of a line set
which is connected to the rebox near the center. As shipped, the line set is wrapped together and xed to the replace. Remove
all wraps and ties prior to installation.
The Wall Access Door is provided with your replace. When locating the Wall Access Door you must consider four types of access:
1. Air access. Room air must be allowed to ow freely through the Wall Access Door perforations, the site-built platform
and the replace chase. The Wall Access Door must be installed in the same room as the replace.
2. Line set access. The line set is to be unwrapped. Do not kink the lineset and do not bend to a radius of less than 2” (50 mm)
3. Physical access. The gas valve/receiver must be readily accessible for maintenance, etc.
4. Wireless access. The signals from the remote must get to the receiver, inside the access door.
If the Access Door is not used its air access equivalent 25 in (161 cm) as well as physical, wireless and line set access must be
provided.
MOUNTING THE CONTROLS
Do not place the controls above the level of the burner. If the replace is to be set directly on the oor, the controls must be placed outside
the non-combustible zone.
The table shows the dimensions and the required rough opening
of the Wall Access Door. The door should be mounted with the
hinge on the left side or with the hinge down.
43”
1092 mm
N/A*
11¼” x 8⁄” (286 mm x 214 mm) 9⁄” x 6⁄” (250 ,, x 175 mm)
Figure 57
Wall Access Door Dimensions
Outer FrameRough Opening
When measured at the level of the feet,
the controls will reach no farther from
the cabinet edge than shown at left.
The drawing is not to scale.
* Controls will not reach to this edge of
the replace
40”
1016 mm
All controls are located on the vent side
Figure 58
43”
1092 mm
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
38
50”
Diameter
of the replace.
Page 39
ENCLOSING the FIREPLACE
Figure 59
Carefully cut the black tie wraps which hold the
line set to the replace then carefully unwrap
the line set. Lay the line set out towards the
location of the Access Door. Do not kink the
lineset and do not bend to a radius of less than
2”/50 mm.
Figure 60
Remove the four bolts holding the white door/
frame cover to the frame. Separate the frame
and cover then mount the Access Door frame
to the rough opening as shown.
Replace the white door/frame cover onto the
frame and secure it with the four bolts.
TEST FIRE
Prior to being placed into operation, the replace should be test-red in stages to ensure that all components are in good working
order. This replace has a 2nd thermocouple which senses the burner ame. The system will turn itself o if the system does not
sense the 2nd thermocouple output within 29 seconds after the valve opens.
If 2nd thermocouple is still hot enough to produce electricity at the receiver thus preventing the replace from starting, the remote
will ash “OFF” to signal this safety lock out. Allow time for the 2nd thermocouple to cool down before attempting a start. The
system is ready to start when the ashing “OFF” becomes solid on the remote and pressing the ON/OFF button produces a response
from the valve.
1. Start the replace with the hearth panel out and with the front glass o. Ensure that the pilot ame both heats the primary
thermocouple and lights the burner. For safety, a post-purge delay is built into the system. Subsequent start attempts
MUST NOT take place for at least thirty (30) seconds.
2. Start the replace with the hearth panel in place and with all of the glass panels xed correctly in place. Ensure that the
main burner ames engulf the 2nd thermocouple and the replace stays lit for at least 1 full minute. If the system turns itself
o after 29 seconds install the required media (next section) and return here. Installing the re media will help with the
ame around the 2nd thermocouple. Subsequent start attempts MUST NOT take place for at least ve (5) minutes.
3. Start the replace with the media installed. If the system turns itself o after 29 seconds, rearrange the media to produce
a good ame at the 2nd thermocouple. This step may have to be repeated several times before the media is in the best
place for consistent operation. A single, long beep indicates that the 2nd thermocouple is still too hot to start the ignition
sequence. Allow time for the 2nd thermocouple to cool down. Once the system stays lit for at least one full minute, turn
the replace o, x the glass panels in place and operate the replace for at least 45 minutes to ensure the system works
properly when heated.
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
39
Page 40
INSTALLING THE FIRE MEDIA
GLASS MEDIA ARRANGEMENTS
Ensure that the hearth panel is sitting rmly on the base of the re box and the shield is installed around the primary thermocouple.
The pilot ame must be visible through the hearth panel and the pilot shield.
Evenly scatter the bag of glass over the top of the hearth panel and burner. Ensure that none of the glass enters the pilot area or
restricts the operation of the 2nd thermocouple.
The arrangement is now complete. However, it is important to check that the pilot ame is still visible.
A shows how the glass is kept clear of the pilot and 2nd thermocouple areas.
Pilot AreaPilot Area
A
ndnd
2 2
Thermocouple Thermocouple
Figure 61
B shows the pilot ssembly.
C shows the 2nd thermocouple.
Pilot AssemblyPilot Assembly
ndnd
22
Thermocouple Thermocouple
Figure 62
To see how to arrange media in an Element4 replace
WWW.EUROPEANHOME.COM/RESOURCES/VIDEOS/
CC
please visit the link below.
BB
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
40
Page 41
SCREEN INSTALLATION
Club 240H F
Upper Tabs5
Lower Tabs5
Magnets15
Long Screen1
Short ScreenN/A
Figure 63Figure 64Figure 65Figure 66
Lower Tab
Short side
against
the glass
Figure 67
Club 240H RC/LC
Upper Tabs8
Lower Tabs8
Magnets24
Long Screen1
Short Screen1
Small side between
trim and glass
Club 240H RD
Upper Tabs13
Lower Tabs13
Magnets39
Long Screen2
Short Screen1
Top magnet
mounts to
inside of
stando frame
Club 240H T
Upper Tabs10
Lower Tabs10
Magnets30
Long Screen2
Short ScreenN/A
Upper Tab
Bottom magnet
mounts to the
inside of screen
frame
Figure 68
Figure 69: Short Screen
Figure 71
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
Figure 70: Long Screen
Place the two Lower Tabs on the trim, with the
short side against the glass, about 2-3” from each
corner of the glass. Place a magnet on the front
of each tab.
41
Page 42
Included in Kit:
- Screen (s)
- Magnets
- Metal tabs
SCREEN INSTALLATION
At the bottom of the trim place one of
the “S” shaped tabs. One end of the tab
will slide between the glass and behind
the trim. Attach a magnet to the tab
facing away from the glass. The screen
will attach to this.
Figure 72
“S” tab with Magnet attached
Magnet
Slide the metal tabs behind the top inside
frame of the replace so that 1 of the magnets
shows (2 magnets on each tab):
Figure 73
Figure 74
Lift the screen so that the
top of the screen comes in
contact with the magnets
on the top tabs:
The small end screen will only have one
metal tab placed at the top center (where
applicable).
Figure 75
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
42
Page 43
OPERATING the FIREPLACE
OVERVIEW
The Club 140 Series replaces may be controlled with one of two devices; the included remote control or the Element4 ProContol
app on your iOS/Android mobile device.
The ProControl app is required for control of both the replace ames and the LED lights and is available at either the Apple App
Store or Google Play.
The remote control allows control of the replace ames only.
BEFORE THE FIRST FIRE
1. Make certain that all construction materials have been removed from inside and around the replace and the replace has
been cleaned of any construction dust. Clean the glass BEFORE and AFTER the rst re.
2. Conrm that the gas valve is properly connected and bled by a certied gas technician or plumber.
3. Check the gas supply for leaks and proper pressure. Refer to the table in “Appliance Ratings” section.
4. Check that the venting is unobstructed and in proper working condition.
5. 5. PROPERLY PLACE, CLAMP, AND SEAL THE GLASS PANELS.PROPERLY PLACE, CLAMP, AND SEAL THE GLASS PANELS.
6. Ensure the receiver is powered with an AC Adapter OR Batteries, NOT BOTH.
7. Place the two (2) AAA batteries into the remote control and conrm that it will communicate with the receiver by pressing
the ON/OFF button. If necessary pair the remote and receiver (see below).
8. Follow USING THE REMOTE CONTROL ELECTRONIC IGNITION SEQUENCE to setup and use remote.
PAIRING THE REMOTE AND RECEIVER (System Reset)
1. Press and hold the receiver reset button using a small, long tool until you
hear the second of two beeps. After the second beep release the reset
button.
2. Press and hold the button on the remote until you hear the second of two
beeps. Release the button.
If you hear one long beep, this indicates the pairing sequence has failed or the wiring
is incorrect. Re-synch the remote.
GAS VALVE KNOBS
After removing the black plastic plug, turn the screw
PRESSURE REGULATOR SCREW
MANUAL KNOB IN
ON POSITION
Figure 77
counterclockwise to lower the pressure and clockwise
to raise the pressure. This adjustment is required for fuel
conversions.
RESET BUTTON
Figure 76
MAIN VALVE KNOB
IN ON POSITION
This knob is AUTOMATIC and will turn
to OFF when the replace is turned
o and to ON when the replace is
turned on.
Note!For normal operation the MANUAL knob on the gas valve cannot be in the MAN position; it must be fully in the ON position.
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
43
Page 44
OPERATING the FIREPLACE
Figure 78
OPERATING the FIREPLACE
Multi-Burner Status
Figure 79
Figure 81
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
Figure 80
44
Page 45
OPERATING the FIREPLACE
Figure 82
OPERATING the FIREPLACE
Figure 83
Figure 84
Figure 85
Figure 86
NOTE: There is a 2 min delay
before the next ignition is
possible.
Figure 88
Figure 87
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
45
Page 46
OPERATING the FIREPLACE
OPERATING the FIREPLACE
Figure 89Figure 90
Figure 91
Figure 93
Figure 95
Figure 92
Figure 94
Figure 97
Figure 96
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
46
Page 47
OPERATING the FIREPLACE
Figure 98
OPERATING the FIREPLACE
Figure 99
Figure 100
29
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
47
Page 48
OPERATING the FIREPLACE
ProControl APP
The Element4 ProControl app has a user friendly, interactive layout and may be used with up to eight Element4 replaces in one
location. The number of users is unlimited so every family member can make use of it after easily making a personal account.
The app has several easy-to-use features; a week long temperature pre-set for a desired room temperature, manual high/low
ame adjustment, Eco Mode and control of the LED lights.
REQUIREMENTS
Before you begin you’ll need:
1) a WiFi-enabled control module (see Appendix Two for correct models)
2) a compatible remote control (see Appendix Two for correct models)
3) a smartphone or tablet using iOS 8.0 or Android 4.4 or later
4) the home wi- network SSID and password
5) a wi- router that supports the 2.4GHz frequency
SETUP
For complete setup information please see attached Getting Started: Element4 ProControl App
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
48
Page 49
OPERATING the FIREPLACE
LEDs
With state of the art LED lighting, a Club 240 Series replace can add colors to your re using a strip of bright RGB LEDs on each
side of the burner.
The LEDs oer the user a possible to create a unique ambiance with maximum control.
Operating the LEDs
Below are listed the color options in the ProControl app. For full instruction see the ProControl manual.
LED Color
With the LED burner you may change the colors of the burner bed as desired. In the application, the colors can be changed by
clicking the color changing button in the app screen and swiping the toggle to the desired color.
LED Brightness
The color brightness can be adjusted with the brightness toggle. To do this, select the brightness button.
Dynamic Colors
As seen on the app screen there are two more buttons. These buttons contain special features for the LEDs.
Touching the left upper button will cause the lights to pulsate. Holding this button, will oer you addition color patterns, such as
the rainbow pattern.
The upper right button is used to turn on the color carousel. In this mode the colors are looped and will gradually change.
Glowing Ember: Red / Yellow / Orange LEDs
Manual : Your color choice.
Party: Popping dierent colors to beats.
Zen: Calm sequence of colors.
Romantic: Red and Pink colors.
Twinkle: Shimmery colors.
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
49
Page 50
OPERATING the FIREPLACE
Figure 101Figure 102Figure 103
Figure 104Figure 105
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
50
Page 51
50
OPERATING the FIREPLACE
THE FIRST FIRE
When the replace is rst heated, an odor may be given o by the hot metal. This is normal and is a result of the ‘burn o’ of the
lubricants and sealants used when manufacturing the replace. We recommend that you open the nearby windows for extra
ventilation and then operate the replace for at least four hours.
When the glass is cold, some condensation may appear on the glass after lighting the replace. This is normal and the
condensation will disappear as the glass warms.
During this rst re, examine the ame for appearance and quality. Examine the burner media for sooting. The ame pattern
should be similar to that show below (Figure ___). Flames may appear blue and will turn yellow after 15 to 20 minutes.
After this burn-o period, turn o the replace and let it cool completely to room temperature and clean both sides of the glass
and the interior panels as described in the MAINTENANCE section.
Since it is a metal replace, the heat-up and cool-down cycles may produce some noises caused by the expansion and contraction
of these metals. The premium materials and build quality of your replace will keep these sounds to a minimum.
Figure 106
To see an Element4 replace starting and running normally
please visit the link below.
WWW.EUROPEANHOME.COM/RESOURCES/VIDEOS/
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
51
Page 52
MAINTENANCE
REMOVING AND CLEANING THE GLASS
OVERVIEW
The glass panels on this replace are held in place by a number of
retaining bolts and gasketed clamps. These instructions will show you
how to remove and install the clamps and glass panels.
Please read these instructions completely before proceeding and visit
our website or use the QR code below for more information.
TOOLS REQUIRED
• No. 2 Phillips screwdriver (not included)
• Gloves (not included)
• Suction Cup
Side Trim
BEFORE YOU BEGIN ENSURE THAT THE GLASS IS COLD!
REMOVING THE GLASS
Step 1.
Remove all of the trim pieces from the replace. The location and
quantity of trim varies with model but in every case there is no top
trim. The trim pieces are held rmly in place with magnets and will
simply lift out. The bottom (horizontal) trim pieces are at the lower
edge of the glass panels and the side (vertical pieces) are where the
glass meets the wall.
Step 2.
Gasketed glass clamps hold the edges of the glass panel in place.
The quantity and location of the clamps vary by model. Remove the
retaining bolt(s) holding the glass clamp and then remove the clamp.
Remove all of the retaining bolts and clamps holding in the rst piece
of glass.
Figure 108
Bottom Trim
Figure 107
Retaining BoltRetaining Bolt
Two-bolt Two-bolt
Glass ClampGlass Clamp
To see how to remove the glass from an Element4 replace
please visit the link below.
WWW.EUROPEANHOME.COM/TECHNICAL/HOW-TO-VIDEOS/
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
52
Page 53
MAINTENANCE
Step 3.
Attach suction cup to the center of the glass and lift the glass up into the clearance
notch.
When the glass panel is raised into the clearance notch there is enough clearance
to swing the lower edge of the glass panel over the stando frame.
When the glass panel is outside of the stando frame then lower the glass panel
out of the clearance notch and carefully, and securely, set the panel aside.
Step 4.
Repeat Steps 2 and 3 for the other glass panels.
CLEANING THE GLASS
The glass should be cleaned as necessary with a replace glass cleaner.
We recommend Stove Bright® Gas Appliance Glass Cleaner by Forrest
Paint Co. It is available through your retailer.
Figure 109
Follow the instructions for use and do not clean the glass when it is hot!
If the glass becomes coated with deposits which cannot be removed it
must be replaced.
INSTALLING THE GLASS
The glass panels should be installed in reverse order of their removal
beginning with the largest glass panel.
Step 1.
Lift the glass panel up into the clearance notch and swing the lower edge of the glass panel against the rebox gasket. Set a glass
clamp into place and hold it loosely into place with a retaining bolt. DO NOT tighten the retaining bolt yet.
Step 2.
Repeat Step 1 with the remaining glass panels.
Step 3.
Center the glass panel, left and right, on the replace and screw the retaining bolts into the lower glass clamp until the bolts touch
the glass clamp. Repeat for the remaining glass clamps on this glass panel.
Step 4.
Slide the adjoining glass panel against the installed glass panel. If there is a second adjoining glass panel slide it into place like the
others.
Firebox Gasket
Figure 110
Glass Panel
Stando Frame
Step 5.
While ensuring that the glass panels are tight and square to each another, tighten the retaining bolt(s) on each clamp NO MORE
THAN ½ TURN past nger tight.
PROPERLY PLACE, CLAMP AND SEAL THE GLASS PANELS BEFORE LIGHTING THE FIRE!
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
53
Page 54
MAINTENANCE
53
WARNING
Installation and maintenance must be performed by an authorized qualied installer, service agency or gas supplier.
TURN OFF THE GAS before servicing the appliance. It is recommended that a qualied service technician perform an
appliance check-up/service once a year.
Any safety screen or guard removed for servicing MUST BE REPLACED before operating this appliance.
DO NOT USE this appliance if any part has been under water. Immediately call a qualied service technician to inspect the
unit and to replace any part of the control system and any gas valve that has been under water.
Any alteration to the product that causes soot or carbon to form and results in damage is not the responsibility of the
manufacturer.
Inspect the external vent cap on a regular basis to make sure that no debris, plants, trees, or shrubs are interfering with the
air ow.
BURNER MAINTENANCE
The ames from the burner should be visually checked. The ame should have a blue base and yellow tops and be candle-like in
appearance.
PILOT MAINTENANCE
The pilot ame must be visually checked. The pilot ame must always be present when the appliance is in operation and should
appear as shown in Figure 106 (with hearth panel removed.)
The pilot has two distinct ames, one engulng the thermocouple on its left, the other reaching across to the burner.
The area around the pilot should be inspected for cleanliness. Lint or foreign material must be removed with a brush or vacuum.
Fi gu re 111
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
54
Page 55
54
Figure 112
MAINTENANCE
THERMOCOUPLE MAINTENANCE
The Element4 fireplaces have two thermocouples; one next
to the pilot and one opposite the pilot side of the burner. The
completeness and operation of both must be checked. A qualied
installer must conrm that both thermocouples are in place and
not damaged. While checking the thermocouple, please ensure
that the ignitor rod is not cracked as well.
VENT MAINTENANCE
The following venting system inspection by a qualied service
technician is recommended every six months:
1. Inspect for excessive condensation, e.g. water droplets
forming in the inner lining and subsequently dripping out of
the joints. This can cause corrosion in the system.
2. Check for corrosion in areas exposed to the elements.
Where rust spots or holes have appeared, these must be
immediately replaced.
3. Ensure that there is no foreign material in the vents. Survey
by removing the cap and shining a light down the vent.
4. Check all joints and pipes to make sure that nothing has
been disturbed or loosened.
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
55
Page 56
MAINTENANCE
REPLACEMENT PARTS
Figure 113
Club 240H F
ITEMDESCRIPTIONQUANTITYPART NUMBER
1FRONT Glass1E4-GLASS-240H
2Safety Screen1E4-SS-9421-STD
3All Tabs with Magnets (Kit)1E4-SA-SS-HWK-5/15
4Lower and Side Trim1REPL-E4-CP-TRIM-MOD-240H
5Foot with Nut6REPL-E4-CP-FT
6Hearth Panel1REPL-E4-CP-HEARTH-240H-CLUB
7Hearth Panel Screws2REPL-34-CP-HPS-01
Figure 114
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
56
Page 57
MAINTENANCE
REPLACEMENT PARTS
Figure 115
Club 240H C
ITEMDESCRIPTIONQUANTITYPART NUMBER
1Front Glass2E4-GLASS-240H
2Side Glass1E4-GLASS-S-240H
3Safety Screen1E4-SS-BID2005-H
4All Tabs with Magnets (Kit)1E4-SA-SS-HWK-5/15 - 3/9
5Lower and Side Trim1REPL-E4-CP-TRIM-BID-240H
6Foot with Nut6REPL-E4-CP-FT
7Hearth Panel1REPL-E4-CP-HEARTH-240H-CLUB
8Hearth Panel Screws2REPL-34-CP-HPS-01
Figure 116
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
57
Page 58
MAINTENANCE
REPLACEMENT PARTS
Figure 117
Club 240H T
ITEMDESCRIPTIONQUANTITYPART NUMBER
1Glass1E4-GLASS-240H
2Safety Screen2E4-SS-9421-STD
3All Tabs with Magnets (Kit)2E4-SA-SS-HWK-5/24
4Lower and Side Trim1REPL-E4-CP-TRIM-TEN-240H
5Foot with Nut6REPL-E4-CP-FT
6Hearth Panel1REPL-E4-CP-HEARTH-240H-CLUB
7Hearth Panel Screws2REPL-34-CP-HPS-01
Figure 118
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
58
Page 59
MAINTENANCE
REPLACEMENT PARTS
Figure 119
Club 240H R
ITEMDESCRIPTIONQUANTITYPART NUMBER
1Glass1E4-GLASS-240H
2Safety Screen1E4-SS-LUC4005-H
3All Tabs with Magnets (Kit)2E4-SA-SS-HWK-5/15 - 3/9
4Lower and Side Trim1REPL-E4-CP-TRIM-TEN-240H
5Foot with Nut6REPL-E4-CP-FT
6Hearth Panel1REPL-E4-CP-HEARTH-240H-CLUB
7Hearth Panel Screws2REPL-34-CP-HPS-01
Figure 120
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
60
Page 61
REPLACEMENT PARTS
Controller
Gas Block
RELAIS
AUX
MODULE
Ribbon Burner
Pilot flame set
2
nd
thermo-couple
6V Adapter
MERTIK MAXITROL
LED 1
LED 2
RGB 1+DO GRN
RGB
power
+ -
RGB 2+DO GRNReceiver
RESET
++
-
-
GRD
24V Power Supply
2
MAINTENANCE
1
3
5
4
Figure 123
7
8
9
ItemDescription
Quantity
(Required)
1Gas valve1E4-GS-GV-01
2
3Ribbon Burner
Receiver
(Control Module)
1
Befor 1/2020E4-GS-CM-Wi- 03
After 1/2020 E4-GS-CM-Wi- 04
4Poilot Assembly1E4 P G S -PA BT- 01
5Second Thermocouple1E4- GS-2TC- 01
66 Volt Adaptor1AC Adaptor-03
7Wi-Box1E4-GS-Con-Wi-02
824 Volt AdaptorAdaptor-24V
910 Button Remote1
Befor 1/2020Repl-E4-GS-RC-10B
After 1/2020 Repl-E4- GS-RC-10B- 02
Part Number
(Each)
Figure 125
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
Figure 124
61
Page 62
WARRANTY
European Home Warranty
Element4 Gas Fireplace
European Home warrants these gas fireplaces against defects in materials and workmanship for a period of TWO (2) YEARS
from the date of original retail purchase. Glass is expressly NOT covered by this warranty.
If a defect exists, European Home will, at its option, either (1) provide needed components using new or refurbished
replacement parts or (2) exchange the product with one which is new or which has been manufactured from new or
serviceable used parts and is at least functionally equivalent to the original product. A replacement product/part assumes the
remaining warranty of the original product or ninety (90) days from the date of replacement or repair, whichever provides
longer coverage for you. When a product or part is exchanged, any replacement item becomes your property and the
replaced item becomes the property of European Home. All warranty claims must be submitted through the dealer from
which you purchased the product. Check with your dealer in advance for any costs to you when arranging a warranty call.
Shipping and/or delivery charges for parts are not covered by this warranty.
Nothing in the above shall be deemed to imply that this warranty shall apply to work which has been abused or neglected or
shows evidence of changes or modifications by others with or without permit, damages caused by the acts of God, building
settlement or moving, fire or vandalism. In addition, installation of this product that varies from the requirements stated in
the instruction manual will void the warranty.
PRODUCT INSTALLATION RECORD
Installer: Please complete this form. Customer: Please retain this information.
Model (check one) Club 240H F Club 240H C Club 240H R Club 240H T
Purchased From
Date of Purchase
Installed By
Date of Installation
Fireplace Serial Number
Fuel Type
Total Venting Horizontal
Total Venting Vertical
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
62
Page 63
APPENDIX ONE
MASSACHUSETTS CERTIFICATION
This appliance is approved for installation in the Commonwealth of Massachusetts. The Board of State Examiners of Plumbers and
Gas Fitters has issued approval number G1-0515-495 for this appliance.
The following must be observed when installing the Element4 replaces within the Commonwealth of Massachusetts:
(a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole
or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust
vent termination is less than seven (7) feet above nished grade in the area of the venting, including but not limited to decks and
porches, the following requirements shall be satised:
1. INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas
fueled equipment, the installing plumber or gastter shall observe that a hard wired carbon monoxide detector with an alarm
and battery back-up is installed on the oor level where the gas equipment is to be installed. In addition, the installing plumber
or gastter shall observe that a battery operated or hard wired carbon monoxide detector with an alarm is installed on each
additional level of the dwelling, building or structure served by the side wall horizontal vented gas fueled equipment. It shall be
the responsibility of the property owner to secure the services of qualied licensed professionals for the installation of hard wired
carbon monoxide detectors
a. In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic,
the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent oor
level.
b. In the event that the requirements of this subdivision can not be met at the time of completion of installation, the
owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that during said
thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be installed.
2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above
provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certied.
3. SIGNAGE. A metal or plastic identication plate shall be permanently mounted to the exterior of the building at a
minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled
heating appliance or equipment. The sign shall read, in print size no less than one-half (½) inch in size, "GAS VENT DIRECTLY
BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS".
4. INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve
the installation unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance
with the provisions of 248 CMR 5.08(2)(a)1 through 4.
(b) EXEMPTIONS: The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4:
1. The equipment listed in Chapter 10 entitled "Equipment Not Required To Be Vented" in the most current edition of
NFPA 54 as adopted by the Board; and
2. Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from
the dwelling, building or structure used in whole or in part for residential purposes.
(c) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM PROVIDED. When the manufacturer of Product
Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the
equipment, the instructions provided by the manufacturer for installation of the equipment and the venting system shall include:
1. Detailed instructions for the installation of the venting system design or the venting system components; and
2. A complete parts list for the venting system design or venting system.
(d) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of a
Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the ue gases, but
identies "special venting systems", the following requirements shall be satised by the manufacturer:
1. The referenced "special venting system" instructions shall be included with the appliance or equipment installation
instructions; and
2. The "special venting systems" shall be Product Approved by the Board, and the instructions for that system shall
include a parts list and detailed installation instructions.
(e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all
venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or
equipment at the completion of the installation.
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
63
Page 64
61
APPENDIX TWO
TROUBLESHOOTING FLOW CHART
FUNCTIONPOSSIBLE CAUSEREMEDY
A.
Press the ON button
to start ignition
sequence. Beep will
occur each
second.
Yes
Transmitter batteries low.
No
Receiver batteries low.
Check that transmitter and receiver are
synchronized.
Transmitter distance is limited.
Defective AC adapterReplace the AC adapter.
Replace remote control batteries.
Quality alkaline recommended.
Test the batteries. replace if necessary.
Quality 1.5V AA alkaline recommended.
Note: Do NOT connect an AC adapter when
using receiver batteries.
Reset system, see the installation manual
or the label on the receiver.
One long beep indicates the wiring is
incorrect or the code learning sequence
has failed.
Straighten the antenna.
Replace the receiver.
B.
Magnet unit is
energized thus pro-
ducing an obvious
latching sound.
No
No
No
Damaged wiringInspect/test all wiring and connections.
2nd thermocouple is producing
electricity.
No beep
3 short beeps
1 long beep
Impulse magnet not
operating properly.
Receiver batteries low.
8-wire cable is o or
not operating
properly.
2nd thermocouple
not connected
SW-cable
disconnected.
Motor not operating
properly.
Micro switch not
operating properly.
Wait for 2nd thermocouple to cool down
(3-5 minutes)
Replace gas valve.
Test the batteries, replace if necessary.
Quality 1.5V AA alkaline recommended.
Conrm proper operation of the 8-wire
cable.
Conrm integrity of 2nd thermocouple and
connection.
Conrm proper connection/operation of
the SW-cable.
Replace gas valve.
Replace gas valve.
Yes
(continued)
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
64
Page 65
APPENDIX TWO
FUNCTIONPOSSIBLE CAUSEREMEDY
Check connection between ignition cable
and ignitor rod.
Check ignitor rod spark gap.
Check ignitor rod.
Check ignition cable for damage.
Increase distance between ignition cable
and all metal parts.
Remove ground bolt (T20 Torx) and clean
ground lug.
Reset system, see the installation manual
or the label on the receiver.
Do not coil the ignition cable.
Shorten the ignition cable, if possible.
C.
Spark will occur
each second.
No
No
No
Ignition components not operating
properly.
Ignition sequence stops after one spark
Ignition sequence stops, no pilot ame.
No reaction to transmitter command.
Yes
D.
Pilot lit.
Yes
E.
Sparking stops after
pilot is lit.
No
No
No
Ignition sequence stops, no pilot ame.
Transmitter command is possible.
TC- and SW-cable reversed.
Magnet unit not operating properly.Replace gas valve.
Short between interrupter and SW cable.Check interrupter block connection.
No gas (magnet unit drops after 30 second
audible count.)
Spark not lighting the pilot.Check spark is crossing the pilot orice.
Cracked ignitor rod (spark heard but not
seen)
Short between interrupter block and TCcable.
Electronic measuring amplier defective.Replace the receiver.
Test the batteries, replace if necessary.
Quality 1.5V AA alkaline recommended.
Check cable connection between receiver
and interrupter block.
Check gas supply.
Ensure that ignitor rod does not move
within ceramic shield. Check that ceramic
shield or ignition wire is not defective.
Check connection to interrupter block.
Yes
(continued)
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
65
Page 66
APPENDIX TWO
FUNCTIONPOSSIBLE CAUSEREMEDY
F.
Motor turns to main
gas and pilot stays
lit.
No
Magnet
unit
drops
(audible
sound)
No
No
Resistance in thermocouple circuit too
high.
Not enough heat on thermocouple.
Low voltage from thermocouple.
No gas (magnet unit drops after 30
second audible count.)
Broken receiver
Ignition sequence stops.
No reaction to transmitter command.
Check thermocouple circuit.
Check position of pilot to thermocouple.
Check the stability and intensity of pilot ame.
Ensure the proper restrictor is installed.
Ensure that the pilot ame is properly
adjusted.
Possible cold start. Wait one minute and retry.
Replace thermocouple. Do not over tighten hand tight plus ¼ turn maximum.
Reset system, see the installation manual or
the label on the receiver.
Do not coil the ignition cable.
Yes
G.
Main burner is lit.
Yes
(continued)
No
Pilot ame under hearth panel not
establishing.
Manual knob is in the “MAN” position.
Pilot ame is too low.
Remove glass and hearth panel then check
for proper pilot operation. If pilot establishes
with panel o then install panel and glass
and adjust pilot ame (hi/lo) for best
operation.
Turn the control knob to “ON” position, a
positive latch is required.
Conrm correct gas pressure. Increase pilot
ame if necessary.
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
66
Page 67
APPENDIX TWO
FUNCTIONPOSSIBLE CAUSEREMEDY
(continued)
H.
Main burner stays
lit.
No
Yes
System
‘drops out’
- all ames
immediately
go out
Too much draft at
pilot ame (poor
ame impingement
of primary
thermocouple.)
Check venting installation. Use
restrictor as required.
Pilot assembly out of
order.
Inspect pilot assembly for correct
operation and thermocouple
impingement.
5 day shut o.
The system shuts o the re and pilot if
there is no change in the ame height
for 5 days.
6 hours of no motor
movement.
In Manual/Temperature/Timer modes
the valve turns down to pilot only if the
ame height does not change for a 6
hour period.
In Temperature/Timer modes if
the ambient room temperature
changes, the ame height will adjust
automatically to maintain the set
temperature and the re will continue
to function normally. The valve will turn
to pilot ame if the set temperature
and the ambient temperature remain
the same over a 6 hour period.
No
Main burner
remains lit
while ames
are lowered.
(Main valve
knob is
turned via
motor.)
No
System goes
to pilot ame
only.
2nd thermocouple is
not heated.
Ensure 2
nd
thermocouple is heated by a
robust ame. The replace media may
be interfering with proper ame. Check
2
nd
thermocouple wiring.
2
nd
thermocouple shut
o.
The system shuts o the re when the
main burner ame is not sensed within
29 seconds of ignition or not sensed
after pressing the large ame button.
Note: If the system fails to light due
to the 2
nd
thermocouple voltage not
being sensed a two minute lockout
period begins. This lockout time allows
the gas to dissipate.
I.
Magnet unit drops
while motor turns.
Receiver makes 3
beeps.
Yes
Receiver batteries low.
Test the batteries, replace if necessary.
Quality 1.5V AA alkaline recommended.
Ensure magnet unit is operating
normally.
Test the receiver output to the magnet unit.
No
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
67
Page 68
APPENDIX TWO
FUNCTIONPOSSIBLE CAUSEREMEDY
J.
Flames become
thin, blue, wispy
then go out.
No
K.
Flames are very
yellow with dark,
sooty tips.
No
L.
Flames are very
busy and blowing in
an abnormal direc-
tion.
Yes
Yes
Yes
Exhaust is contaminating the fresh air.
Flow of fresh air and/or exhaust is
blocked.
Natural gas being used with LP orice(s).
The air shutter is closed when using
LP gas.
Flow of fresh air and/or exhaust is
blocked.
Air leak in the rebox.
Inspect venting for damage and/or incorrect
installation.
Ensure that vent conguration is within the
vent chart requirements.
Check termination for blockage and/or
appropriate type.
Ensure the gas type is correct for the
installed orices.
When using LP gas the air shutter must be fully
open. See conversion instructions.
Ensure that vent conguration is within the
vent chart requirements.
Check termination for blockage and/or
appropriate type.
Check unit for leaks at glass corners or at
gaskets.
Check unit for positive relief door seal.
Check venting for complete integrity.
No
M.
Flames are stable
but too small and
blue.
No
NORMAL
OPERATION
Yes
Too much primary air.
Reduce the primary air opening until ames have blue
base and yellow upper two-thirds.
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
68
Page 69
Remote/Receiver Combinations
APPENDIX TWO
SYSTEMCOMPONENT
Remote ControlE4- GS-RC-10BB6R- HATV4BW
10 Button Remote
918 mHz
Gas ValveRepl-E4-GS-GV-01GV60M1-C5B1KL-0003Maxitrol Gas Valve
EUROPEAN HOME
PART NUMBER
ReceiverE4-GS-CM-Wi-03B6R-RAPT2
MAXITROL PART
NUMBER
DESCRIPTION
Maxitrol Esave
10 Button Remote
supports Wi-Fi
Maxitrol Receiver
supports Wi-Fi
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
69
Page 70
ProControl Error Codes
APPENDIX TWO
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
70
Page 71
ProControl Error Codes (con’t.)
APPENDIX TWO
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
71
Page 72
APPENDIX THREE
CONNECTING TO A SMART HOME SYSTEM (Smart Home System Cable)
GENERAL NOTES
The replace may be operated through an external source such as a smart home (home automation) system by using the 5-pin
connector on the receiver.
A required 39” (990 mm) cable, with connector, is available (p/n E4-SA-SHSC-02). The overall cable length should not exceed 26’
(7925 mm.)
Signal relays (gold contacts) or opto-couplers are recommended but not supplied. The E4-SA-SHSC-02 cable must be connected
to the three smart home system contacts as shown below.
WARNINGWARNING
You MUST ensure that the replace is in a safe and ready condition before attempting to operate it from a remote location.You MUST ensure that the replace is in a safe and ready condition before attempting to operate it from a remote location.
SEQUENCEOF OPERATION
• To start ignition, close contacts 1 and 3 simultaneously
for 1 second.
• To set the valve to High Fire, close contact 1.
To set the valve to Pilot, close contact 3. In each case, the
contacts need to be closed for 12 seconds to turn the
motor from one end-stop to the other end stop.
• To set the valve to the O position, close contacts 1, 2,
and 3 simultaneously for 1 second.
Figure 126
E4-SA-SHSC-02
MODESOF OPERATION
• Mode 1 - the external source provides “ON“ and “OFF“
operation only. The remote control provides all other
functions.
Note: Even if the re is switched on by the external
source, the remote control, in the thermostatic mode,
controls the room temperature. The room temperature
setting of the remote control will remain the same for
the next ON-cycle of the external source as long as the
temperature setting of the remote control has not been
changed. If the remote control is in manual mode, it will
go to High Fire in the next cycle of external operation.
• Mode 2 - The remote control must be set to the manual
mode if the external source is to control the room
temperature. If the handset is placed in the thermostatic
mode it will override the external source.
NOTE:
Frequent ON and OFF cycles will limit life expectancy of the
valve and will increase battery consumption. The replace
should be powered by the AC adapter for improved
reliability and customer satisfaction.
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
72
Page 73
APPENDIX FOUR
Step 1. Carefully remove the front glass according to the Removing and Cleaning the Glass section.
Figure 127
Step 2. Insert the short black glass rst and push it up against the side and back wall. Unscrew the top mounting screw and slide on
the black tab making sure the at face is against the black glass. Tighten the screw to hold the tab and black glass in place.
(This step is for the Club 240 F and Club 240 RC/LC models only)
Figure 128Figure 129
Step 3. Using the provided suction cups, carefully put the top end of the glass into the top channel rst. Push up until the bottom
end of the glass clears the bottom channel. Lower the glass into the bottom channel.
Figure 130
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
73
Page 74
APPENDIX FIVE
Errors codes Procontrol App
Error
Message in AppDescriptionPossible cause
code
F02 Contact service5 seconds beep from the receiver.
No response from receiver, and no
inammation.
• No engine end stop
• Wiring motor
• Microswitch
• Knob B
F03 Contact service5 seconds beep from the receiver.
Ignition process is interrupted
No response from receiver, and no ignition.
F04Ignition failure. wait 1
minute, than try again.
F06 Contact service3rd time start attempt within 5 minutes• No gas
F10Contact servicePilot is on
F12 Contact serviceMotor turns to pilot light position• Receiver above 60 °
F13 Contact serviceMotor turns to pilot light position• Receiver above 80 °
F14 Contact service5 sec. beep
F15Contact service5 sec. beep
No pilot ame within 30 sec.
After 3rd attempts F06
2nd thermocouple procedure
Starting again after 2 min
No reaction from the replace and no ignition
No reaction from the replace and no ignition
Thermocouple wiring not in order / interrupted
• No gas
• Air in the pipe
• No spark
• Air in the pipe
• No spark
• 2nd thermocouple is not heated
• 2nd thermocouple blocked by decoration material
• Wiring not in order
• 2nd thermocouple interrupted
• No right recipient
• 2nd thermocouple not connected
• Wiring 2nd thermocouple
F16 Hand transmitter out
of reach
F17 Contact service No ignition
F19 Contact servicePilot ame goes out when the main burner is
F26Contact serviceNo high ame regulation possible• Receiver above 60 °
F28On-Demand pilot Pilot ame goes out• Pilot ame goes out after there has been no motor
F31 Contact serviceNo reaction from the replace
F41Controleer Wi-Fi No reaction from the replace• No Wi-Fi connection
F43No receiver connected.
Contact service
F44 Contact serviceNo temperature display in the App
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
No temperature in the app• Hand transmitter out of reach for more than 1.5
hours.
• Electrical fault
• Voltage above 7.5 volts
No reaction from the replace
opened
No control possible by the electronics
No reaction from the replace
No control possible by the electronics
“N.a.” in the App
74
• AC adapter defective
• 1st Thermocouple voltage not sucient
• 1st thermocouple defective
• Too low pressure
• Resistance in the thermocouple circuit
• Gas control block (magnetic coil)
movement for a long time.
• Receiver defective
• No communication between receiver and Wi-Fi
module
• No hand transmitter connected
• Batteries hand transmitter empty
Page 75
APPENDIX FIVE
Error
code
F04 F044 sec. 5 seconds beep from the receiver.
F06 F064 sec.3rd time a start attempt within 5 minutes No gas
F09F094 sec. No reaction from the replace.
F40 Battery symbol
F46 F464 sec. No reaction from the replace
App MessageTimeDescriptionPossible Cause
No engine end stop
Contact service
No response from receiver, and no
ignition.
No electronic control
Continu Battery voltage in the hand transmitter
too low
Interrupted responses
No electronic control
Wiring motor
Microswitch
Knob B
Air in the pipe
No spark
The torque of the hand transmitter and receiver
did not work
Replace batteries
2x 1.5 V AAA
No or bad connection between the receiver and
hand transmitter
No voltage on the receiver
Low communication range, AC adapter
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
75
Page 76
APPENDIX FIVE
Faults and error codes in the remote
This appendix can be consulted when error messages occur
in the application for smartphone and tablet.
F41 error
This message will appear if there is no or bad Wi-Fi reception,
this can be between app and router or Wi-Fi box and router
App
By closing the App and opening it again, this is solved in
most cases.
Cause
The cause may be that the ProControl module is blocked or is
too far away from the router.
See: router information.
Possible solution
Only place an external router for the ProControl module
Strengthen existing Wi-Fi signal
Resetting the router.
Router information
Minimum requirement
• Compatible with IEEE 802.11n / g / b
• WPA2 encryption
• Radio frequency 2.4 GHz band
• Wireless automatic channel: Automated search for WLAN
radio channel that is free from interference.
• Support for the User Datagram Protocol (UDP)
Wi-Fi Router
It is important to think carefully about the location of a
router. This device spreads the wi signal in and around your
home. Therefore, preferably choose a central position. You
prevent long distances from occurring. Many people put
the router in the meter cupboard, because that is where the
internet comes in at many households. A bad choice! For
a powerful WiFi signal, the router needs as much space as
possible. Therefore, do not place the device near a wall or on
the ground. Some routers have multiple antennas that you
can target. Try to spread these antennas so that you increase
the range.
Jammers
Many devices also emit radio waves just like your router.
These include microwave ovens, wireless doorbells, baby
monitors, Bluetooth adapters, wireless music systems, DECT
telephones and security cameras. These devices can disrupt
your wireless network (interference), so the Wi-Fi connection
is not optimal. Try to keep jammers as far away as possible
from the router. Neighboring wireless networks also play a
role in the Wi-Fi area.
Figure 131: Application screen
2.4 or 5 GHz band?
By default, most routers use the 2.4 GHz band to broadcast
the Wi-Fi signal. The disadvantage is that this frequency band
is very busy, so that there is quickly interference. There are
a lot of competing users and jammers using the same radio
waves.
Since most “older” laptops, smartphones, tablets and other
devices can not connect via the 5GHz band, the ProControl
module is not suitable for 5GHz band.
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
76
Page 77
NOTES
Element4 Gas Fireplaces Rev #01272020 www.EuropeanHome.com
77
Page 78
INDEX
C
CERTIFICATION
APPLIANCE RATINGS11
LISTING LABEL11
MASSACHUSETTSAppENdIx ONE
CLEARANCES
LOCATION18
MANTELS20
WARM AIR OUTLET(S) 21
E
ELECTRIC
24V POWER SUPPLY11
AC ADAPTER11
ENCLOSING THE FIREPLACE
FRAMING30
MINIMUM AREA - CLUB 240H F 32
MINIMUM AREA - CLUB 240H C 33
MINIMUM AREA - CLUB 240H R 34
MINIMUM AREA - CLUB 240H T 35
REDUCED CLEARANCETO COMBUSTIBLE WALLS31
F
FIRE MEDIA
INSTALLINGTHE STONES40
FIRST FIRE 51
G
GAS
INSTALLINGTHE GAS LINE22
PRESSURES11
O
OPTIONS
BLACK GLASSAppENdIx FOUr
SMART HOMEAppENdIx ThrEE
P
PARTS OF THE FIREPLACE 16
S
SCREEN INSTALLATION 41
SMART HOME AppENdIx ThrEE
SPECIFICATIONS
APPLIANCE RATINGS11
DIMENSIONS - CLUB 240H F
DIMENSIONS - CLUB 240H C 13
DIMENSIONS - CLUB 240H R 14
DIMENSIONS - CLUB 240H T 15