Element4 Trisore 140 MKII, Lucius 140 T MKII, Bidore 140 MKII Installation, Operation And Owner's Manual

Page 1
Installation, Operation and
Owner’s Manual
Modore 140 MKII
Bidore 140 MKII
Product
Information
Trisore 95
Video
Trisore 140 MKII
Direct Vent
HOT GLASS WILL Une surface vitrée chaude CAUSE BURNS. peut causer des brûlures.
DO NOT TOUCH GLASS Laisser refroidir la surface UNTIL COOLED. vitrée avant d’y toucher.
NEVER ALLOW CHILDREN Ne permettez jamais á un enfant TO TOUCH GLASS. de toucher la surface vitrée.
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed for the protection of children and other at-risk individuals.
Une barrière conçu pour réduire le risque de brûlure par le verre de visualisation chaude est fournie avec cet appareil et doit être installé pour la protection des enfants et autres personnes à risque.
WARNING:
FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury, death, or property damage.
AVERTISSEMENT:
INCENDIE OU D’EXPLOSION Le non-respect des avertissements de sécurité à la lettre pourrait entraîner de graves blessures , la mort ou des dommages matériels.
- Do not store or use gasoline or other ammable
vapors and liquids in the vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call
the re department.
- Installation and service must be performed
by a qualied installer, service agency or the
gas supplier.
INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.
Element4 Gas Fireplaces EuropeanHome.com
- Ne pas entreposer ni utilizer d’essence ni d’autres vapeurs
ou liquides inammables dans le voisinage de cet appareil
ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ
• Ne pas tenter d’allumer d’appareil.
• Ne touchez á aucan interrupteur. Ne pas vous servir des téléphones se trouvant dans le bátiment ou vous trouvez.
• Quitter immédiatement le bâtiment.
• Appelez immédiatment votre fournisseur de gaz depuis un voisin. Suivez les instructions du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incindies.
- Installation et l’entretien doivent être effectués par un
installateur qualié, une agence de service ou le fournisseur
de gaz.
INSTALLATEUR: Laissez cette notice avec l’appareil. CONSOMMATEUR: Conservez cette notice pour consultation ultérieure.
1
4006 611
April 1, 2016
Page 2
TABLE OF CONTENTS
Important Safety Information 3 Key Installation Points 6 User Information 7 Specications and Dimensions 8 Modore 140 MKII 9 Bidore 140 MKII 10 Trisore 140 MKII 11 Parts of the Fireplace 12 Clearances 14 Gas and Electric 18 Venting 19 Conguration 19 Venting Charts 22 Venting Clearances 23 Enclosing the Fireplace 25
Non- combustible Materials List 25 Rough Opening Dimensions 28 Convection Air Opening 32
Installing the Fire Media 37 Screen Installation 39 Operating the Fireplace 42 Maintenance 48 Glass 48 Burner 50 Pilot 50 Thermocouple 51 Venting 51 Replacement Parts 51 Warranty 52 Massachusetts Certication Appendix One Troubleshooting Flowchart Appendix Two LP Conversion Appendix Three Installing the Optional Wall Switch Appendix Four Connecting To A Smart Home System Appendix Five Index ---
Page 3
IMPORTANT SAFETY INFORMATION
CAUTION - HOT! HOT! HOT!
This appliance is a HEATING appliance and it does become very hot in operation. UNDER ANY CIRCUMSTANCES, DO NOT PLACE any object, furniture, draperies or other item LESS THAN 36”/90 cm IN FRONT OF THE GLASS OF THE FIREPLACE.
CHILDREN AND PETS
Radiant heat can heat surfaces such as the surround and trims of the replace to temperatures that, although approved safe, can be quite uncomfortable to touch - particularly for children and pets. Children and pets should always be supervised when in the room where the appliance is located. Remote control handset should be kept out of reach of children. In the presence of children, we STRONGLY RECOMMEND that you install in front of the replace: a re screen or, to protect young toddlers, a “hearth gate”.
HOT SURFACES
Be aware that, although safe, some combustible materials and nishes, even though installed at listed clearances may, over time, discolor, warp or show cracks. Convective heat will exit the unit and travel up the wall surface if not impeded. Protruding mantels and projections can help direct the heat away from the wall. AVOID placing heat sensitive items such as televisions, paintings, decorations, etc. above replaces or near the edge of protrusions unless appropriate.
Do not place furniture or other objects within 36” of the replace glass.
SAVE THESE INSTRUCTIONS
Make yourself fully aware of all the following instructions and the many features of the Element4
direct vent gas replace appliance.
INSTALLER: Leave this manual with the appliance.
OWNER: Keep this manual for future reference.
Element4 Gas Fireplaces EuropeanHome.com
3
Page 4
IMPORTANT SAFETY INFORMATION
WARNING
Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or clothing ignition.
WARNING
This direct vent system appliance must be installed as an OEM installation in manufactured homes (USA only) or an aftermarket permanently located, or a mobile home, where not prohibited by local codes and must be installed in accordance with Manufacturer’s instructions and the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the United States, or the Standard for Installation in Mobile Homes, CAN/CSA Z240 MH Series, in Canada.
WARNING: Installation and Service
Installation and service must be performed by an authorized qualied installer, service agency or gas supplier.
Any alteration to the product that causes soot or carbon to form and results in damage is not the responsibility of the manufacturer.
ONLY a qualied person may open the door/remove the glass.
Do not modify or substitute any part of this appliance.
WARNING: Electrical Grounding
These direct vent appliances must be electrically grounded in accordance with the local codes or, in the absence of local codes, with National Electric code, ANSI/ NFPA 70, or the Canadian Electric Code, CSA C22.1
If the information in these instructions is not followed exactly a re or explosion may result causing property damage, personal injury or death.
Do not store or use gasoline or other ammable vapors and liquids in the vicinity of this appliance.
WARNING: Glass Handling
The glass must only be removed by a qualied person. Gloves should be worn when removing the glass.
WARNING: Gas Appliance
This appliance is only for use with the type of gas indicated on the rating plate. These appliances are not convertible for use with other gases unless a certied kit is used and the conversion is performed by an authorized qualied technician.
Applicable standards are ANSI Z21.50/CSA 2.22 (Vented Gas Fireplaces) and CAN/CGA 2.17-M91 (Gas-red Appliances for Use at High Altitudes.) If your installation is at an elevation greater than 2000’ in the US or 4500’ in Canada, consult with the local authority having jurisdiction for gas product installations to determine their specic requirements for high altitude installations.
Element4 Gas Fireplaces EuropeanHome.com
4
Page 5
IMPORTANT SAFETY INFORMATION
This gas replace and vent assembly MUST be vented directly to the outside and MUST NEVER be attached to a chimney serving a separate solid fuel burning appliance. Each gas appliance MUST BE a separate vent system. Common vent systems are prohibited.
This unit MUST be used with a vent system as described in this installation manual. NO OTHER VENT SYSTEM OR COMPONENTS MAY BE USED.
INSPECT the external vent cap on a regular basis to make sure that no debris, plants, trees, or shrubs are interfering with the air ow.
TURN OFF the gas before servicing the appliance. It is recommended that a qualied service technician perform an appliance check-up/service once a year.
Any safety screen or guard removed for servicing MUST BE REPLACED before operating this appliance.
THIS UNIT IS NOT FOR USE WITH SOLID FUEL, and must only be used with gas supply conditions as indicated on the rating label.
DO NOT USE this appliance if any part has been under water. Immediately call a qualied service technician to inspect the unit and to replace any part of the control system and any gas control that has been under water.
NEVER OBSTRUCT the ow of ventilation air. Keep the front of the appliance CLEAR of all obstacles and materials for servicing and proper operation.
The glass panels MUST be in place and sealed before the unit can be placed into safe operation.
DO NOT OPERATE this appliance with the glass panels removed, cracked or broken. Replacement of the glass panels should be performed by a licensed or qualied service person. DO NOT strike or slam the glass panels.
The glass panels SHALL ONLY be replaced by units supplied by the manufacturer. NO SUBSTITUTE panels shall be used.
DO NOT USE abrasive cleaners on the panels. DO NOT ATTEMPT to clean the glass panels when they are hot.
DO NOT use this appliance as a temporary source of heat during construction.
This appliance is a vented gas replace. It must not be used for any other purposes such as drying clothes, etc.
If the pilot ame is extinguished either intentionally or unintentionally, no attempt should be made to re-light the gas until at least 3 minutes have elapsed.
Dimensions will appear as INCHES”/metric throughout this manual. For convenience, the inches are rounded to the nearest 1/16” when converted. If greater accuracy is required, use the metric dimensions.
Element4 Gas Fireplaces EuropeanHome.com
5
Page 6
KEY INSTALLATION POINTS
IMPORTANT
INFORMATION
This page references the most important key installation points when installing any Element 4 replace. This page DOES NOT substitute for reading the entire manual.
RECORDS
The installer MUST record the serial number and venting conguration to use for any technical issues that may arise.
ELECTRICAL
The receiver MUST be powered by either the AC adapter or 4 (AA) batteries, NEVER both at the same time.
FIRE MEDIA
When installing the re media make sure to NEVER mix dierent types of media or use media purchased from another retailer. ALWAYS keep the second thermocouple AND pilot free from media.
CONVECTION AIR
The convection air outlets MUST be installed BEFORE the rst light. The amount of square inches needed for the opening varies from model to model.
ENCLOSING THE FIREPLACE
ONLY a tested and approved non-combustible wallboard that is specied in the manual may be used when enclosing the replace.
VENTING
The venting MUST follow the model specic graph shown in the manual. A restrictor may or may not need to be used based on venting run and rise.
CONSTRUCTION DEBRIS
REMEMBER that if the replace is installed before the site is nished, construction debris MUST be cleaned from the enclosure and around the unit prior to nishing and the test re.
GAS PRESSURES
Gas pressures MUST be read with a manometer and conrmed with what is required in the installation manual.
FINISHING
A ⁄”/3 mm gap between the ange and the enclosing wallboard MUST be maintained to prevent cracking from heat expansion and contraction.
Element4 Gas Fireplaces EuropeanHome.com
6
Page 7
USER INFORMATION
WARMTH AND BEAUTY  HOW IT WORKS
The Element4 replaces are direct vent replaces and, as such, the intake and exhaust are both handled through the vent pipe. The replace also provides convection air to your room. The illustration shows one of the unique features of the Element4 replaces - its use of warm, convection air ow.
Other replaces have louvered metal boxes around them to keep temperatures under control. The Element4 replaces use your enclosing walls, or chase, to guide this warm air. This design, therefore, requires the use of non-combustible wall materials and gives you beauty for your eort.
When the air within the chase is warmed by the replace, it rises and exits through the Convection Air Outlet. This chase air is then replaced by room air which enters the chase through the Room Air Inlet and through the Wall Access Door. As the exiting warm air cools, it falls to the oor where it's drawn into the inlets and the cycle repeats.
The replace provides the inlet for room air as part of its design; you provide the warm air outlet as part of your design.
See the ENCLOSING the FIREPLACE section of this manual for more information.
Warm Air Out
Room Air In
Warm Air Out
Site-built Chase
Room Air In
Element4 Gas Fireplaces EuropeanHome.com
Access Door
Room Air In
7
Page 8
APPLIANCE RATINGS
SPECIFICATIONS and DIMENSIONS
Modore 140 MKII
Model
Bidore 140 MKII Trisore 140 MKII
Gas Natural Gas Propane
Input Maximum Btu/hr 38,200 34,100
Input Minimum Btu/hr 13,650 11,950
Maximum Supply
Pressure
Minimum Supply
Pressure
Manifold Pressure
Maximum
Manifold Pressure
Minimum
in. w.c. 7 11
kpa 1.74 2.74
in. w.c. 4 8
kpa 1 2
in. w.c. 4.0 10.8
kpa 0.99 2.68
in. w.c. 0.4 1.5
kpa 0.1 0.38
Main Burner Injector Marking 650 (x2) 220 (x2)
Pilot Injector Marking 31.2 27.1
Eciency 80.6%
DO NOT REMOVE
DIRECT VENT GAS FIREPLACE - Not for use with solid fuel.
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home where not prohibited by local codes. See owner’s manual for details. This appliance is not convertible for use with other gases, unless a
certied kit is used.
For use only with Vent, Glass Panels and Ceramic Logs (or
stones) certied and approved for use with this appliance.
This appliance must be installed in accordance with local codes, if any; if none, follow ANSI Z223.1/NFPA 54, or CSA B149.1. The appliance must be properly connected to a venting system in ac­cordance with the manufacturer’s installation instructions.
The system must be installed by ba qualied installing agency.
SAMPLE
Manufacturer/ Fabricant: Element4 B.V.
Paxtonstraar 23
NL-8013 RP Zwolle The Netherlands / Pays-Bas Tel / Tél : 0031 38 4209020
Fax:0031 38 4209021
Product name: (check one) / Nom du produit : (cochez …) Trisore 100H [ ] Bidore 100H [ ] Modore 100H [ ]
Serial No. / N° de série: _____________
This appliance equipped only for altitudes / Cet appareil est équipé uniquement pour les altitudes : 0-4500 ft / 0-1370 m
Fuel Type / Type de combustible Natural Gas / Propane Gas / Gaz naturel Gaz propane (check one) / (cochez…) [ ] [ ]
Max. Input / Capacité d’entrée maxi (BTU/HR) 34145 34145
Min. Input / Capacité d’entrée mini (BTU/HR) 15025 17075 Gas Inlet Pressure (in w.c.) / Pression d’entrée du gaz (en w.c.) 7 11 Manifold Pressure (in w.c.) / Pression d’admission (en w.c.) 2.1 7.4
Orice Size / Taille de l’ouverture 650 (x2) 180 (x2)
Clearances to combustible / Dégagement jusqu’au combustible :
Back / Arrière : 11” (28cm) Sides / Côtés : 11” (28cm) Top / Haut : 26” (66cm) Floor / Sol : 4” (10cm) Mantel / Linteau : 2” (5cm)
NE PAS RETIRER
FOYER GAZ À AÉRATION DIRECTE - Ne pas utiliser avec un combustible solide
Cet appareil est destiné uniquement avec le type de gaz indiqué sur la plaque signalétique et peut être installé dans une habitation en dur,
à emplacement xe (USA uniquement) ou dans une résidence mobile
si la législation locale l’autorise. Consultez le manuel du propriétaire
pour les détails. Cet appareil ne doit pas être modié pour une utilisa­tion avec d’autres gaz, sauf à l’aide d’un kit certié.
À utiliser uniquement avec des ventilations, panneaux en verre et
poutres (ou pierres) en céramique dont l’utilisation est autorisée avec cet appareil.
Cet appareil doit être installé conformément à la législation locale. À défaut d’une telle législation, suivre ANSI Z223.1/NFPA 54, ou CSA B149.1. L’appareil doit être proprement raccordé à un système de
ventilation, conformément aux instructions d’installation du fabricant.
Le système doit être installé par un installateur qualié.
Approved By / Approuvé par:
Control No. : 4006611 Conforms to std. ANS Z21.50a-2008
Certied to std. CSA 2.22a-2008 - Vented Gas Fireplaces
AC ADAPTER SPECIFICATIONS
Input Voltage 120 V AC
Element4 fireplace and contains important certification information. It must not be removed from the replace.
Input Power 9 W
Output Voltage 6V DC
Output Current 500 mA
Size 3.1”H x 2”W x 1.7”D
Output Cord Length 6 Feet
Agency Approvals UL, CSA
AC Adapter Connection (arrow)
AC Adapter
A typical rating label is shown above. It is attached to every
Element4 Gas Fireplaces EuropeanHome.com
8
Page 9
SPECIFICATIONS and DIMENSIONS
Modore 140 Mk II Planning Dimensions
11/2015
Element4 B.V. EuropeanHome.com
manufactured by distributed by
MODORE 140 MKII
Front Elevation
Letter Inches Millimeters
A 58⁄ 1488
B 54⁄ 1386
C 54⁄ 1386
D 16½ 419
E 44⁄ 1138
F 50¾ 1288
G 55½ 1410
H 56⁄ 1446
I 13⁄ 338
Right Elevation
Plan View
J 28⁄ 714
K 27⁄ 700
L 11⁄ 282
M 4⁄ 118
N 16⁄ 423
O 10⁄ 275
P 4⁄ 105
Q 1⁄ 27
A DWG les is available for download at www.europeanhome.com for design specic dimensions not listed.
Element4 Gas Fireplaces EuropeanHome.com
MODORE 140 MKII
9
Page 10
SPECIFICATIONS and DIMENSIONS
Bidore 140 Mk II Planning Dimensions
11/2015
Element4 B.V. EuropeanHome.com
manufactured by distributed by
BIDORE 140 MKII
Front Elevation
Letter Inches Millimeters
A 58⁄ 1496
B 57 1447
C 54⁄ 1388
D 54⁄ 1388
E 16⁄ 421
F 44⁄ 1138
G 50¾ 1288
H 55 1397
I 4⁄ 105
J 26½ 672
K 12⁄ 326
L 10⁄ 277
Right Elevation
M 4⁄ 118
N 234
O 10⁄ 270
P 13⁄ 338
Q 56¾ 1441
R 58⁄ 149 6
S 11 278
T ½ 12
Plan View
A DWG les is available for download at www.europeanhome.com for design specic dimensions not listed.
Element4 Gas Fireplaces EuropeanHome.com
BIDORE 140 MKII
10
Page 11
SPECIFICATIONS and DIMENSIONS
Trisore 140 Mk II Planning Dimensions
11/2015
Element4 B.V. EuropeanHome.com
manufactured by distributed by
Front Elevation
Right Elevation
TRISORE 140 MKII
Letter Inches Millimeters
A 59⁄ 1507
B 58⁄ 1475
C 54½ 1383
D 55⁄ 1400
E 44⁄ 1138
F 50¾ 1288
G 13⁄ 338
H 59⁄ 1506
I 11½ 291
J 28⁄ 714
K 27⁄ 700
L 12¾ 324
M 4⁄ 118
N 8⁄ 224
O 16⁄ 420
P 10⁄ 275
Q 1⁄ 47
R 4⁄ 105
S ½ 13
Plan View
A DWG les is available for download at www.europeanhome.com for design specic dimensions not listed.
Element4 Gas Fireplaces EuropeanHome.com
TRISORE 140 MKII
11
Page 12
SPECIFICATIONS and DIMENSIONS
PARTS OF THE FIREPLACE
The various parts of the 140 MKII Series replaces are shown below. These parts are typical of any Element4 replace.
12
11
1
6
2
7
5
8
9
10
3
Table of Fireplace Parts
Outer Frame Face - surrounds the glass panels and limits the non-combustible wall board
1
Exterior Glass Panel(s) - (1 - Modore, 2 - Bidore, 3 - Trisore)
2
14
4
Support Feet - four adjustable feet allow the replace to be levelled
3
Hearth Panel - supports various Fire Media
4
Primary Burner - produces the ame
5
Flange
6
Pilot Burner - the part of the safety circuit which lights the Main Burner
7
2nd Thermocouple - the part of the safety circuit which monitors the Main Burner
8
Finish Trim - hides the Glass Clamps
9
Glass Rope Gaskets - holds the Glass Panel in place (2 ea. - Modore, 3 ea. - Bidore, 4 ea. - Trisore)
10
Vent Collar - accepts the 5” x 8” venting adapter (included)
11
Relief Door - part of the safety system. Do NOT block the operation.
12
Pilot Assembly
13
Upright Trim - (2 ea. - Modore, Bidore, Trisore)
14
Element4 Gas Fireplaces EuropeanHome.com
12
Page 13
SPECIFICATIONS and DIMENSIONS
3
13
3
Fireplace from below
Table of Fireplace Parts
Outer Frame Face - surrounds the glass panels and limits the non-combustible wall board
1
Exterior Glass Panel(s) - (1 - Modore, 2 - Bidore, 3 - Trisore)
2
3
3
Support Feet - four adjustable feet allow the replace to be levelled
3
Hearth Panel - supports various Fire Media
4
Primary Burner - produces the ame
5
Flange
6
Pilot Burner - the part of the safety circuit which lights the Main Burner
7
2nd Thermocouple - the part of the safety circuit which monitors the Main Burner
8
Finish Trim - hides the Glass Clamps
9
Glass Rope Gaskets - holds the Glass Panel in place (2 ea. - Modore, 3 ea. - Bidore, 4 ea. - Trisore)
10
Vent Collar - accepts the 5” x 8” venting adapter (included)
11
Relief Door - part of the safety system. Do NOT block the operation.
12
Pilot Assembly
13
Upright Trim - (2 ea. - Modore, Bidore, Trisore)
14
Element4 Gas Fireplaces EuropeanHome.com
13
Page 14
CLEARANCES
These are NOT zero-clearance fireplaces. All clearances to combustible AND non- combustible materials MUST be maintained as described in this manual.
LOCATING THE FIREPLACE
When selecting a location for the replace:
• Ensure that all minimum clearances to combustible AND non­combustible materials are met.
• Provide adequate clearances for servicing.
• Consider venting dimensions (rise, run and number of elbows, etc.) when selecting the location for your replace.
• Locate the appliance out of trac and away from furniture and draperies.
• Keep the location free of electrical, plumbing or other heating/air conditioning ducting.
PLACING THE FIREPLACE
The base upon which the appliance rests must be sturdy, level and built to safely support at least 500 pounds/230 kilograms. The base may be the oor or a purpose-built raised platform, e.g. wood, metal. When placed on a platform, an 8”/203 mm x 6”/152
mm opening must be cut through the platform top. The lineset
can be routed through this opening. Room air must be allowed to ow through the Wall Access Door then through this opening.
MINIMUM CLEARANCE TO COMBUSTIBLES
• The appliance is approved with a minimum clearance to combustible materials of 26”/660 mm to the top, 11”/280
mm on all sides and 4”/100 mm to the bottom. Any spacer
or framing used closer than this dimension must be non­combustible (e.g. metal).
• The minimum distance from the bottom of the appliance to the room ceiling is 72”/1830 mm.
• When installing the venting, the following clearances to combustible materials MUST be maintained:
a. 3”/76 mm above any horizontal venting b. 1”/25 mm to venting sides or below any horizontal
venting
• Do not block or restrict the Room Air Inlet, located between the stando frame and glass.
The minimum clearances (air spaces) to combustible materials must be maintained. It is of the greatest importance that the replace and vent system be installed only in accordance with these instructions.
Clearance to combustibles summary: Back: 11”/280 mm
Sides: 11”/280 mm Top: 26”/660 mm Floor: 4”/100 mm
The feet on the appliance are designed to sit on a at platform, however the appliance must not be installed on any combustible material other than wood. For example, carpet or linoleum bases are not permitted.
Do not place anything between the bottom of the rebox and the bottom of the feet.
ENSURE THAT THE LINESET (WHICH INCLUDES THE GAS VALVE, ELECTRICAL WIRING, AND GAS LINES) DOES NOT IMPEDE THE FULL OPERATION OF THE RELIEF DOORS (if applicable). IT IS YOUR RESPONSIBILITY TO ENSURE THE SAFETY OF THESE CRITICAL COMPONENTS THROUGHOUT THE INSTALLATION PROCESS.
The Floor dimension (above) is measured from the bottom of the rebox. When the adjustable feet are in their lowest position the required clearance to the oor is maintained.
Element4 Gas Fireplaces EuropeanHome.com
14
Page 15
CLEARANCES
140 MKII SERIES
140 MKII SERIES
CLEARANCES TO COMBUSTIBLE MATERIAL
Clearances to Combustibles
Sides (Non-Glass Sides ONLY) 11”
Top 26”
Bottom 4”
CLEARANCES TO NON-COMBUSTIBLE MATERIAL
Clearances to Non-Combustibles
Sides (Non-Glass Sides ONLY) 2”
Top 2”
Bottom 4”
No material of any kind is allowed between the bottom of the support feet and the bottom of the rebox (except for the
lineset).
No material of any kind is allowed within 2”/50 mm from the top of the replace.
No material of any kind is allowed within 2”/50 mm from the metal sides the replace.
Facing material should be installed against the outer frame of the replace, with an  ⁄”/3 mm vertical or horizontal clearance
TO THE FLANGE allow for heat expansion.
Non-combustible materials may be installed to a zero clearance to the outer faces of the appliance outer frame face. However,
they must not cover (or prevent the removal of) the glass panels or other replace parts.
Below the feet materials may be combustible (except for the use of linoleum or carpeting of any type).
These clearances are the same for ALL Element 4 Fireplaces, regardless of model.
Please refer to the “Reduced Clearance to Existing Combustible Wall” section for use of combustibles inside of the above clearances.
Element4 Gas Fireplaces EuropeanHome.com
15
Page 16
CLEARANCES
(2") 50
C
SECTION
A-A
900
COMBUSTIBLE MATERIALS NOT PERMITTED IN FRONT OF GLASS
MANTELS
The graph below shows a range of allowable depths and heights for a combustible mantel installation.
As shown, the minimum allowable mantel height above the replace opening is 2”/50 mm with a 1”/25 mm deep mantel.
The maximum mantel depth is 12”/300 mm at a minimum height above the replace opening of 13”/330 mm.
All of the mantel height/depth combinations fall in between these extremes in accordance with the chart below.
Mantels made of non-combustible material are allowed inside these dimensions but they will be subjected to elevated temperatures and may become too hot to touch.
A typical completed installation with mantel is shown in the diagram below, on the right.
INCHES
13”/330 mm
Mantel Height
Mantel Depth
12”/300 mm
1”/25 mm
2”/50 mm
Element4 Gas Fireplaces EuropeanHome.com
16
Page 17
CLEARANCES
TYPICAL CLEARANCE DIAGRAMS
The total area of the convection air outlet(s) depends on the replace model. The location of the outlet(s) must allow for the free movement of air and must not allow excessive convection air to build up within the chase.
The top of the outlet(s) must be at least 1”/25 mm down from the room ceiling and we recommend no more than 3”/76 mm down. The top of the outlet(s) must be no more than 1”/25 mm down from the chase ceiling.
The minimum distance from the bottom of the appliance to the room ceiling is 72”/1830 mm.
B
Convection Air Outlet
Minimum Distances
Room ceiling to
A
appliance bottom
Room ceiling to top of
B
Convection Air Outlet1”25 mm
72”
1830 mm
A
Convection Air Outlet Area by Model
Model Square Inches Square Centimeters
Modore 140 MKII 70 452
Bidore 140 MKII 70 452
Trisore 140 MKII 70 452
Element4 Gas Fireplaces EuropeanHome.com
17
Page 18
GAS and ELECTRIC
INSTALLING THE GAS LINE
Correctly size and route the gas supply line from the supply regulator to the area where the appliance is to be installed as per requirements outlined in the latest edition of the National Fuel Gas Code, NFPA 54 (USA) or CAN/CSA-B149.1 (Canada).
Never use galvanized or plastic pipe unless specied for use with gas. Refer to the table below for proper sizing of the supply gas line. Gas lines must be routed, constructed and made of materials that are in strict accordance with local codes and regulations. A qualied plumber or gas tter should be hired to correctly size and route the gas supply line to the appliance.
Installing a gas supply line from the fuel supply to the appliance involves numerous considerations of materials, protection, sizing, locations, controls, pressure, sediment trap, and other criteria. The sizing and/or installing of gas piping should only be performed by a qualied plumber or gastter.
The gas control inlet accepts a ⁄” NPT tting.
This replace is shipped from the factory for use with natural gas. See appendix for LP (propane) conversion instructions.
Schedule 40 Black Iron Pipe
Length (feet) Inside Diameter (Inches)
0 - 10 ½ ⁄
10 - 40 ½ ½
40 - 100 ½ ½
100 - 150 ¾ ½
150 - 200 ¾ ½
Natural
Gas
Propane
Gas
ELECTRICAL REQUIREMENTS
The Element4 replaces use a receiver and remote control for their burner operation. The remote control comes with (3) AAA batteries and the receiver is powered by a 120V AC adapter, included. The replace should be powered by the AC adapter for improved reliability and customer satisfaction.
The installer must provide an approved 120V AC wall receptacle to be placed within the six foot cord limit of the AC adapter.
The receiver may be powered by either the AC adapter or (4) AA batteries - not both. Batteries do not provide an electrical backup
for the AC adapter. Using batteries in combination with the AC adapter can lead to a damaged receiver.
Electrical work must be performed by a qualied, licensed electrician.
WARNING
Element4 Gas Fireplaces EuropeanHome.com
All wiring shall be in compliance with all local, city, and state codes.
18
Page 19
VENTING
CONFIGURATION
CONFIGURING THE VENTING
The replaces in this manual are direct vent replaces that use a co-axial or “pipe within a pipe” venting system. The outer “pipe” or vent conducts fresh, outside air into the replace and the inner vent carries the exhaust outside. This system, which can run either horizontally through a side wall or vertically through the roof, produces an ecient system because conditioned building air is not used for combustion.
Only the 5” x 8” direct vent components from M&G DuraVent are approved for use with these replaces. Any of the M&G DuraVent 5” x 8” direct vent components suitable for the local condition are permitted. Please visit www.europeanhome.com/ qr-support or via the QR code below for installation instructions.
This replace is shipped with a North American venting adapter. It MUST attach to the vent collar of the replace.
All venting measurements are taken from the top center of the vent collar on the top of the replace and all congurations must fall within the acceptable range of the venting charts.
A minimum clearance of 3”/75 mm must be maintained between combustible materials and the top of any horizontal vent pipe surface; a minimum clearance of 1”/25 mm must be maintained between combustible materials and any other vent pipe surface.
The horizontal parts of the venting must be pitched up away from the replace. For every 12” / 305 mm of horizontal run, the venting must rise ¼” ⁄ 6.5 mm toward the termination. The venting must never run downward unless with the use of a power vent.
Whenever venting passes through a wall, an approved heat shield or ‘wall thimble’ must be installed.
A power vent system is available for venting that falls outside of the venting graphs. Refer to the appropriate power vent manual for any venting conguration which is outside of the vent graphs shown here.
Your venting needs to be inspected annually, including any connected components, to ensure that the system is working as designed.
APPROVED MANUFACTURERS and COMPONENTS
Manufacturer Components
M&G DuraVent, Inc.*
For the M&G venting installation guide or power venting installation manuals
please visit the link below.
www.europeanhome.com/qr-support
only DirectVent Pro®
5” x 8” venting components
Element4 Gas Fireplaces EuropeanHome.com
19
Page 20
VENTING
CONFIGURATION
R
R
N
N
S
T
N
S
N
N
S
T
S
Q
T
R
N
S
Vertical or Horizontal Vent Termination R
45 or 90 degree bends Vertical to Horizontal or vice versa N
45 and 90 degree bends Horizontal to Horizontal Q
Horizontal Pipe Section T
Vertical Pipe Section S
CALCULATING THE TOTAL VERTICAL SECTION (TVS)
Calculate the Total Vertical Section by adding up all vertical upward sections in your specic vent design.
CALCULATING THE TOTAL HORIZONTAL SECTION (THS)
Calculate the Total Horizontal Section by adding up all vertical upward sections in your specic vent design.
Element4 Gas Fireplaces EuropeanHome.com
20
Page 21
VENTING
CONFIGURATION
BEWARE OF ELBOWS
Elbows do not help the movement of air through your venting conguration and must be included when determining your minimum and maximum vent lengths.
45° elbows are calculated as either vertical or horizontal depending on positioning.
There are (2) types of elbows: TYPE N 45° and 90° elbows from vertical to horizontal and vice versa
-The rst (3) N elbows do not need to be included in venting calculations.
-For every extra N elbow, you must add 40”/(1m) to your THS
TYPE Q 45° and 90° elbows from horizontal to horizontal
-For each 90° elbow in the horizontal section you must add 80”/(2m) to your THS
-For each 45° elbow in the horizontal section you must add 40”(1m) to your THS
INTERPRETING THE GRAPH RESULTS
Once you have found your total vertical section (TVS) and your total horizontal section (THS) determine where you vent conguration will terminate on the corresponding venting chart (shown on the next page).
These venting numbers will correlate as follows:
x
If your venting conguration lands on a block with an “X” the conguration is not possible.
For venting congurations that land on an “X” a power vent option may be available.
CALCULATING THE TOTAL VERTICAL SECTION (TVS)
Calculate the Total Vertical Section by adding up all vertical upward sections in your specic vent design.
CALCULATING THE TOTAL HORIZONTAL SECTION (THS)
Calculate the Total Horizontal Section by adding up all vertical upward sections in your specic vent design.
INSTALLING A RESTRICTOR
Some vent congurations may require a restrictor plate be installed. The restrictor for this replace is installed on the inside top of the replace and is to be slid open or closed. Loosen the screws on either side and slide the restrictor as desired. Do not modify the restrictor(s). Please use the graph above to determine if you will need to use a restrictor.
Loosen thes e (2) Phillip’s head screws to slide on/o the restrictor.
35 mm
Element4 Gas Fireplaces EuropeanHome.com
21
Page 22
VENTING
HORIZONTAL TERMINATIONS & RESTRICTOR USE
rise
VENTING CHARTS
run
VERTICAL TERMINATIONS & RESTRICTOR USE
rise
KEY
x
Element4 Gas Fireplaces EuropeanHome.com
run
22
Page 23
VENTING
HORIZONTAL VENT TERMINATION CLEARANCES AND REQUIREMENTS
CLEARANCES
Element4 Gas Fireplaces EuropeanHome.com
23
Page 24
VENTING
CLEARANCES
VERTICAL TERMINATION CLEARANCES AND REQUIREMENTS
Important Note for Roof Terminations
These instructions should be used as a guideline and do not supersede local codes in any way. Install venting according to local codes, these instructions, the current National Fuel Gas Code (ANSI Z223.1 in the USA) or the current standard of CAN/CSA-B149.1 in Canada.
A second termination may be no closer than 12”/305 mm.
Element4 Gas Fireplaces EuropeanHome.com
Termination Heights
Multiple Termination Clearance
24
Page 25
ENCLOSING the FIREPLACE
COMBUSTIBLE MATERIALS
Materials that can catch re and burn are considered combustible. Any material that is made of, or faced with, wood, wood pulp, paper, plastic or any other material that can catch re and burn is considered combustible. Even though these materials may have been ‘ame-proofed’, made ‘re-resistant’ or are ‘re-rated’ they are considered combustible. Standard and Type X drywall are both combustible.
NON-COMBUSTIBLE MATERIALS
A material is said to be non-combustible when it cannot catch re and burn. For example, materials made entirely, or in combinations, of, stone, brick, concrete, tile, steel, plaster or glass are considered non-combustible.
The table below shows a list of materials which, as of this writing, are reported by their manufacturers to be non-combustible (in accordance with the ASTM E136 standard) AND approved for use around replaces.
Skamol Skamotec® 225 and the Promat PROMAFOUR® system are preferred products for enclosing replaces.
Product Thickness
Skamol Skamotec® 225 Fireplace Building Board 1½”/38 mm
Promat PROMAFOUR® System ½”/12 mm, ⁄ ”/15 mm, ¾”/18 mm
James Hardie Building Products HardieBacker® 500 ½” Cement Board ½”/12 mm
James Hardie Building Products HardieBacker® ¼” Cement Board ¼”/6 mm
* The listed brand names are trademarks of their respective companies
Skamol Americas, Inc. (844) 475-2665 E-mail: skamotec225@skamol.com www.skamotec225.com
Promat Inc. (865) 681- 0155 E-mail: sales@promat.us www.promat.us/en
James Hardie Building Products (888) 542-7343 www.jameshardie.com
Element4 Gas Fireplaces EuropeanHome.com
25
Page 26
ENCLOSING the FIREPLACE
BUILDING THE ENCLOSURE
A safe installation of your Element4 replace requires that four things be clearly understood.
1. Most important, these replaces are NOT zero-clearance replaces. Unlike zero-clearance replaces, there is not a metal box around the Element4 replaces. With no metal box there are no louvers to distract your view of the re. However, we want the cooling advantage of a metal box so your site-built, non-combustible enclosure will substitute.
2. Your replace enclosure must be made to act the way a metal replace box acts - letting room air in below and warm convection air out above. The framing cannot interfere with the air ow. The Room Air Inlet is part of the replace and cannot be changed or adjusted. The convection air outlet is part of your enclosure design, is provided by you and MUST be included.
Note! The convection air outlet must be installed in the same room as the replace or a space which ALWAYS ows air into the room in which the replace is installed. The ow of convection air must NOT be blocked.
3. Since these are not zero-clearance replaces, the clearances and dimensions listed in the CLEARANCES section MUST be maintained. Only the non-combustible wall, the mounting brackets and the venting may touch the replace. As previously stated, NOTHING may be built closer than 2”/50 mm to the non-glass sides.
4. The controls will be mounted to your enclosure and below the burner. The controls are at the end of a 50”/1270 mm line set and are to be mounted to the Wall Access Door which is included. The controls must be located for ease of physical access (gas line, maintenance, etc.) as well as wireless signal (remote control) access. See the LOCATING THE CONTROLS and the MOUNTING THE CONTROLS sections.
The combination of multiple glass sides and no zero-clearance box makes for a non-typical enclosure project. It may seem straightforward to build the ‘rough opening’, set the replace then attach the wall. However, for most projects, it will be easier to rst set the replace in position then enclose it with Skamol Skamotec® or Promat PROMAFOUR® building board.
REDUCED CLEARANCE TO EXISTING COMBUSTIBLE WALLS
When retrotting the replace against an existing wall it is often desirable to reduce the distance between the replace and the combustible wall. Normally, this distance is 11”/280 mm but it may be reduced by shielding the existing nished wall with a 1” air gap and a sheet of non-combustible material as shown.
IN ALL CASES:
• A reduced clearance shield is ONLY ALLOWED ON A VERTICAL WALL; IT IS NOT ALLOWED TO BE USED ON OTHER SURFACES WITHIN THE NON-COMBUSTIBLE ZONE.
• The non-combustible wall shield MUST extend more than 26”/660 mm above the top of the replace. The shield shall be placed no closer than 1”/25 mm to the oor or any intersecting walls. Air MUST be allowed to continually circulate around all sides of the wall shield.
• A 1”/25 mm air gap between the wall shield and the existing wall MUST be maintained.
• A 2”/50 mm air gap between the wall shield and the replace MUST be maintained.
Element4 Gas Fireplaces EuropeanHome.com
26
Page 27
ENCLOSING the FIREPLACE
REDUCED CLEARANCE TO EXISTING COMBUSTIBLE WALLS
COMbUSTIbLE WALL
COMbUSTIbLE WALL
ShIELd OvER FINIShEd WALL
2”/50 mm
Minimum Air Gap MUST BE MAINTAINED
ShIELd OvER FINIShEd WALL
1”/25 mm Minimum Air Gap MUST BE MAINTAINED
COMbUSTIbLE WALL
ShIELd OvER FINIShEd WALL
Element4 Gas Fireplaces EuropeanHome.com
ShIELd OvER FINIShEd WALL
COMbUSTIbLE WALL
The non-combustible wall shield MUST EXTEND MORE than 26”/660 mm above the top of the replace.
27
Page 28
ENCLOSING the FIREPLACE
MINIMUM AREA REQUIRED FOR MODORE 95 MKII
MODORE 140 MKII
FRONT STANdOFF FRAME FLUSh
When enclosing the Modore 140 MKII replace there is a minimum clear area which must be maintained. Nothing except the Modore 140 MKII may be within this area. When enclosed, the Modore 140 MKII is centered - stand o frame face in line with the front inside or back inside blue limit and centered- above. This minimum area MUST BE DEFINED BY NON-COMBUSTIBLE MATERIAL. The inside of the enclosing walls (including any necessary framing) may be no less than the distances shown above.
Note! The nished walls must be at least 1⁄”/28 mm thick or the replace trim will extend beyond the nished walls.
We recommend that the replace be set into its nal location before building the enclosure.
Element4 Gas Fireplaces EuropeanHome.com
28
Page 29
ENCLOSING the FIREPLACE
MINIMUM AREA REQUIRED FOR BIDORE 95 MKII
BIDORE 140 MKII
FRONT STANdOFF FRAME FLUSh
When enclosing the Bidore 140 MKII replace there is a minimum clear area which must be maintained. Nothing except the Bidore 140 MKII may be within this area. When enclosed, the Bidore 140 MKII is centered - stand o frame face in line with the front inside or back inside blue limit and centered- above. This minimum area MUST BE DEFINED BY NON-COMBUSTIBLE MATERIAL. The inside of the enclosing walls (including any necessary framing) may be no less than the distances shown above.
Note! The nished walls must be at least 1⁄”/28 mm thick or the replace trim will extend beyond the nished walls.
We recommend that the replace be set into its nal location before building the enclosure.
Element4 Gas Fireplaces EuropeanHome.com
29
Page 30
ENCLOSING the FIREPLACE
MINIMUM AREA REQUIRED FOR TRISORE 95 MKII
TRISORE 140 MKII
FRONT STANdOFF FRAME FLUSh
When enclosing the Trisore 140 MKII replace there is a minimum clear area which must be maintained. Nothing except the Trisore 140 MKII may be within this area. When enclosed, the Trisore 140 MKII is centered - stand o frame face in line with the front inside or back inside blue limit and centered- above. This minimum area MUST BE DEFINED BY NON-COMBUSTIBLE MATERIAL. The inside of the enclosing walls (including any necessary framing) may be no less than the distances shown above.
Note! The nished walls must be at least 1⁄”/28 mm thick or the replace trim will extend beyond the nished walls.
We recommend that the replace be set into its nal location before building the enclosure.
Element4 Gas Fireplaces EuropeanHome.com
30
Page 31
ENCLOSING the FIREPLACE
The nished wall(s) must be at least 1⁄”/28 mm thick or the replace trim will extend beyond the nished wall. The list below shows the thickness of the approved wall products.
Your choice of wall material depends largely on the intended nish. For example, a thinner wall product and a layer of stone may be thick enough to reach the trim edge. If a painted nish is desired then a wall at least 1⁄”/28 mm thick will suce.
Product Thickness
Skamol Skamotec® 225 Fireplace Building Board 1½”/38 mm
Promat PROMAFOUR® System ½”/12 mm, ⁄ ”/15 mm, ¾”/18 mm
James Hardie Building Products HardieBacker® 500 ½” Cement Board ½”/12 mm
James Hardie Building Products HardieBacker® ¼” Cement Board ¼”/6 mm
Fireplace Trim
Minimum Wall Thickness =
1⁄”/ 28 mm
Element4 Gas Fireplaces EuropeanHome.com
31
Page 32
ENCLOSING the FIREPLACE
Modore 140 with
Convection Outlets
Bidore 140 with
Convection Outlets
Modore 140 with
Outlet Reveal
Bidore 140 with
Outlet Reveal
Trisore 140 with
Convection Outlets
Modore 140 MKII 70 452
Element4 Gas Fireplaces EuropeanHome.com
Convection Air Outlet Area by Model
Model Square Inches Square Centimeters
Bidore 140 MKII 70 452
Trisore 140 MKII 70 452
32
Trisore 140 with
Outlet Reveal
Page 33
ENCLOSING the FIREPLACE
DO NOT ALLOW THE FIREPLACE
TO BEAR ANY WEIGHT
Dimension A, B, and C must be equal throughout the installation.
Any support framing (NON-combustible framing ONLY) must be at least 2”/50 mm away, above and beside the replace. The entire weight of the non-combustible walls must be borne by a structure other than the replace.
C
B
A
Element4 Gas Fireplaces EuropeanHome.com
33
Page 34
ENCLOSING the FIREPLACE
COLD CLIMATE INSULATION
For cold climate installations, it is especially important to insulate outside the chase cavity, between studs and under the oor on which appliance rests, if oor is above ground level. Gas line holes and other openings should be lled with approved restop.
If the replace is being installed on a cement slab in cold climates, a sheet of plywood or a raised platform can be placed underneath to prevent cold transferring to the replace and into the room. It also helps to tape the venting for maximum air tightness and to caulk restops.
LOCATING THE CONTROLS
The control system for the Element4 replaces consist of three major components:
the receiver
the remote
the gas valve
The remote is the remote control by which you operate the replace. The receiver and the gas control are at one end of a line set which will extend approximately 50”/1270 mm from the center of the replace. The other end of the line set is connected to the rebox just left of center. As shipped, the line set is wrapped together and xed beside the replace.
The Wall Access Door is provided with your replace and is designed to hold the receiver and gas control. When locating the Wall Access Door you must consider four types of access:
1. Air access. Room air must be allowed to ow freely through the door perforations, up through the site-built platform and above, through the enclosing replace chase.
2. Line set access. The line set is to be unwrapped which allows the controls to be then placed within approximately 50”/1270 mm from the center of the replace, as the cable runs.
3. Physical access. The gas valve/receiver must be readily accessible for maintenance, etc.
4. Wireless access. The signals from the remote must get to the receiver, inside the access door.
If the Access Door is not used its air access equivalent (25 square inches) as well as line set, physical and wireless access must be provided.
MOUNTING THE CONTROLS
Do not place the controls above the level of the burner. If the replace is to set directly on the oor, the controls must be placed outside the non-combustible zone or insulated from the heat from the replace.
The Wall Access Door (11¼”/286 mm high x 8⁄”/214 mm wide outer frame) requires a rough opening of 9⁄”/250 mm high x 6  ⁄ ”/175 mm wide. The door should be mounted with the hinge on the left side or with the hinge side down.
Wall Access Door Dimensions
Outer Frame Rough Opening
11¼”/286 mm x 8⁄”/214 mm 9⁄”/250 mm x 6⁄”/175 mm
Element4 Gas Fireplaces EuropeanHome.com
34
Page 35
ENCLOSING the FIREPLACE
Carefully cut the black tie wraps which hold the line set to the side of the replace then carefully unwrap the line set. Lay the line set out towards the location of the Access Door. Do not kink the lineset and do not bend to a radius of less than 2”/50 mm.
Remove the four bolts holding the white door/ frame cover to the frame. Separate the frame and cover then mount the Access Door frame to the rough opening as shown.
Replace the white door/frame cover onto the frame and secure it with the four bolts.
Fit the gas control tab into the bracket on the Access Door frame.
Element4 Gas Fireplaces EuropeanHome.com
Tighten the bolt through the mounting bosses.
35
Page 36
ENCLOSING the FIREPLACE
Set the receiver into the Wall Access Door bracket as shown and connect the AC adapter.
Wall Access Door with gas control and receiver mounted.
TEST FIRE
Prior to being placed into operation, the replace should be test-red in stages to ensure that all components are in good working order. This replace has a 2nd thermocouple which senses the main burner ame. The system will turn itself o if the system does not sense the 2nd thermocouple output within 20 seconds after the main valve opens.
Note that a single, long beep indicates that the 2nd thermocouple is still hot enough to produce electricity at the receiver which will not allow the replace to start. Allow time for the 2nd thermocouple to cool down before attempting a start. The system is ready to start when pressing the ON/OFF button produces a response from the valve.
1. Start the replace with the hearth panel out and with the front glass o. Ensure that the pilot ame both heats the primary thermocouple and lights the main burner. For safety, a post-purge delay is built into the system. Subsequent start attempts MUST NOT take place for at least thirty (30) seconds.
2. Start the replace with the hearth panel in place and with all of the glass panels xed correctly in place. Ensure that the main burner ames engulf the 2nd thermocouple and the replace stays lit for at least 1 full minute. If the system turns itself o after 20 seconds install the required media (next section) and return here. Installing the re media will help with the ame around the 2nd thermocouple. Subsequent start attempts MUST NOT take place for at least ve (5) minutes.
3. Start the replace with the media installed. If the system turns itself o after 20 seconds, rearrange the media to produce a good ame at the 2nd thermocouple. This step may have to be repeated several times before the media is in the best place for consistent operation. A single, long beep indicates that the 2nd thermocouple is still too hot to start the ignition sequence. Allow time for the 2nd thermocouple to cool down. Once the system stays lit for at least one full minute, turn the replace o, x the glass panels in place and operate the replace for at least 45 minutes to ensure the system works properly when heated.
Element4 Gas Fireplaces EuropeanHome.com
36
Page 37
INSTALLING THE FIRE MEDIA
LSE 418 II
LOG ARRANGEMENTS
Ensure that the hearth panels are properly placed and sitting rmly on the base of the re box. The pilot ame must be visible through the panel and the cut-out in the pilot shield. Scatter the bag of chips evenly on the hearth panel and burners. Ensure that the area inside the pilot shield and the area around the 2nd thermocouple remains clear of media.
What’s in the box? (LSE 418 II)
-(1) small bag of ash
-(2) bags of black/grey chips
-(2) pine cones
-(9) logs
With the chips scattered across the burner and hearth panel, lay the logs in the following sequence...
The bag of ash (shown left) comes with your log set. Its purpose is to make the logs look more realistic. The use of this ash is optional.
To use:
- Sprinkle the ash onto the logs as desired.
- Make sure that the ash DOES NOT get inside of the burner ports. If so, clogging may occur.
Element4 Gas Fireplaces EuropeanHome.com
37
Page 38
INSTALLING THE FIRE MEDIA
STONES/GLASS ARRANGEMENTS
Ensure that the hearth panel is sitting rmly on the base of the re box and the shield is installed around the 2nd thermocouple. The center panel must be inserted in between the burner tubes. The pilot ame must be visible through the hearth panel and the pilot shield.
Evenly scatter the contents of the bag of stones/glass over the top of the hearth panel and burner. Ensure that none of the stones/ glass enters the pilot area or restricts the operation of the 2nd thermocouple.
The arrangement is now complete. However, it is important to check that the pilot ame is still visible.
A shows the arrangement for stones; the arrangement for glass is similar.
A
2nd Thermocouple
(actual burner pilot assembly and thermocouple location may vary depending on model)
(grey stones shown here)
B shows the pilot area (below) clear of media (above).
C shows the 2nd thermocouple area (below) clear of media (above).
B
Pilot Assembly
Pilot Area
C
2nd Thermocouple
To see how to arrange media in an Element4 replace
WWW.EUROPEANHOME.COM/RESOURCES/VIDEOS/
Element4 Gas Fireplaces EuropeanHome.com
please visit the link below.
38
Page 39
SCREEN INSTALLATION
MODORE 140 MKII
Upper Tabs 2
Lo wer Tabs 2
Magnets 6
Long Screen 1
Short Screen N/A
against the glass
BIDORE 140 MKII
Upper Tabs 3
Lo wer Tabs 3
Magnets 9
Long Screen 1
Short Screen 1
Lower TabShort side
Tall side against the screen
Top half mounts to backside of stando frame (top)
TRISORE 140 MKII
Upper Tabs 4
Lo wer Tabs 4
Magnets 12
Long Screen 1
Short Screen 2
Up per Tab
Top half mouints to backside of screen frame (top)
Short Screen
Element4 Gas Fireplaces EuropeanHome.com
Long Screen
Place the (2) Lower Tabs on the trim, with the short side against the glass, ~2-3” from each corner of the glass. Place a magnet on the front of each tab.
39
Page 40
SCREEN INSTALLATION
Place the (2) Upper Tabs on the inside of the top stand o frame. One magnet will be hidden, attached to the standoff frame. The other magnet will be exposed to attach to the screen.
Element4 Gas Fireplaces EuropeanHome.com
This is what the screen will look like when it is attached correctly to the top Upper Tabs (view from inside of the stando frame).
40
Page 41
SCREEN INSTALLATION
This is what the screen will look like when it is attached correctly to the top Lower Tabs (view between the screen and the glass).
Element4 Gas Fireplaces EuropeanHome.com
The screen is installed properly in the photo above. Please make sure that all magnets are in the correct position and the tabs are secured.
41
Page 42
OPERATING the FIREPLACE
BEFORE THE FIRST FIRE
1. Make certain that all construction materials have been removed from inside and around the replace and the replace has been cleaned of any construction dust. Clean the glass BEFORE and AFTER the rst re.
2. Conrm that the gas valve is properly connected and bled by a certied gas technician or plumber.
3. Check the gas supply for leaks and proper pressure. --- Refer to the table in “Appliance Ratings” section.
4. Check that the venting is unobstructed and in proper working condition.
5. PROPERLY PLACE, CLAMP, AND SEAL THE GLASS PANELS.
6. Ensure the receiver is plugged in with AC Adapter OR Batteries... NOT BOTH.
7. Place the three AAA batteries into the remote control and conrm that it will communicate with the receiver by pressing the ON/OFF button. If necessary pair the remote and receiver.
8. Follow USING THE REMOTE CONTROL ELECTRONIC IGNITION SEQUENCE to setup and use remote.
PAIRING THE REMOTE AND RECEIVER (System Reset)
From the factory, the remote control will communicate with the receiver; they are ‘paired’ and should need no further attention. If the receiver does not respond to commands from the remote they should be paired to each other. This is done as follows:
1. Press and hold the receiver reset button using a small, long tool until you hear the second of two beeps. After the second beep release the reset button.
2. Press and hold the button on the remote until you hear the second of two beeps. Release the button.
If you hear one long beep, this indicates the pairing sequence has failed or the wiring is incorrect.
RESET BUTTON
MANUAL KNOB IN
ON POSITION
Note! For normal operation the MANUAL knob on the gas valve cannot be in the MAN position; it must be fully in the ON position.
MAIN VALVE KNOB
IN ON POSITION
(This knob is AUTOMATIC and will
turn o when the replace is turned o & on when the replace is turned on.)
Element4 Gas Fireplaces EuropeanHome.com
42
Page 43
OPERATING the FIREPLACE
NOTICE
WARNING
Countdown Timer
Program Mode
Display
SETTING FAHRENHEIT or CELSIUS
To change between °C and °F, press and
AM
PM
ON OFF
1 2
buttons simultaneously.
NOTE: Choosing °F results in a 12 hour clock.
Choosing °C results in a 24 hour clock.
1 2
ON OFF
Time
Temperature
Signal Indicator Child Proof
AM
PM
CHILD PROOF
ON OFF
1 2
Thermostatic Mode
Auxiliary Feature
ON:
AM PM
To activate, press and buttons simultaneously displayed and the remote is rendered inoperable, except for the o function.
Battery Status
Fahrenheit or Celsius
Eco Mode
SETTING the TIME
1. Press and buttons simultaneously. Day ashes.
AM PM
ON OFF
1 2
2. Press or button to select a number to correspond with the day of the week (e. g. = Monday, = Tuesday, = Wed­nesday, = Thursday, = Friday, = Sat­urday, = Sunday).
3. Press and buttons simultaneously. Hour ashes.
4. To select hour press or button.
5. Press and buttons simultaneously. Minutes ash.
6. To select minutes press or button.
7. To conrm press and buttons simultaneously or wait.
OFF: To deactivate press and buttons simultaneously. disappears.
MANUAL MODE REMOTE
BEFORE OPERATING
1. Make sure MANUAL knob on the valve is in the ON, full coun­terclockwise
position.
2. Place the ON/OFF switch (if equipped) in the I (ON) position.
TO TURN ON FIRE
TO TURN ON FIRE
***PLEASE SEE NEXT PAGE FOR FURTHER INSTRUCTIONS***
When pilot ignition is conrmed, motor turns automatically to maximum ame height.
Element4 Gas Fireplaces EuropeanHome.com
43
Page 44
OPERATING the FIREPLACE
NOTICE
NOTICE
WARNING
WARNING
Remote One-Button Operation
AM PM
ON OFF
1 2
(Default Setting)
• Press and hold button until two short beeps and a blinking series of lines conrms the start sequence has begun; release button.
• Main gas ows once pilot ignition is conrmed.
• Remote automatically goes into Manual Mode after main burner ignition.
Change from one-button to two-button ignition operation by pressing and holding talling batteries. complete
will change to .
button for 10 sec. immediately after ins-
is displayed and is ashing. When change is
Remote Two-Button Operation
AM PM
ON OFF
1 2
• Press and button simultaneously until two short beeps and a blinking series of lines conrms the start sequence has begun; release buttons.
• Main gas ows once pilot ignition is conrmed.
• Remote automatically goes into Manual Mode after main burner ignition.
Change from two-button to one-button ignition operation by pressing and holding talling batteries. complete
will change to .
button for 10 sec. immediately after ins-
is displayed and is ashing. When change is
FLAME HEIGHT ADJUSTMENT
FLAME HEIGHT ADJUSTMENT
AM PM
ON OFF
1 2
Remote
• To increase ame height press and hold button.
• To decrease ame height or to set appliance to pilot ame, press and hold button.
DESIGNATED LOW FIRE and HIGH FIRE
NOTE: Backlight must be on for high re and low re double-click
operation.
• To go to low re, double-click button.
AM
is displayed.
NOTE: Flame goes to high re rst before
going to low re.
• To go to high re, double-click button.
AM
is displayed.
If the pilot does not stay lit after several tries, turn the main valve knob to OFF and follow the operating instructions “TURN OFF GAS TO APPLIANCE”.
STANDBY MODE PILOT FLAME
STANDBY MODE PILOT FLAME
Remote
Press and hold
button
to set appliance to pilot ame.
TO TURN OFF FIRE
Remote
• Press
AM PM
ON OFF
1 2
Element4 Gas Fireplaces EuropeanHome.com
NOTE: There is a 5 second delay before the
button to turn OFF
next ignition is possible.
If the appliance will not operate, follow the instructions “TURN OFF GAS TO APPLIANCE”.
COUNTDOWN TIMER
ON/SETTING:
AM PM
ON OFF
1 2
.
1. Press and hold button until displayed,
and hour ashes.
2. To select hour press or button.
3. To conrm press button. Minutes
ash.
4. To select minutes press or button.
5. To conrm press button or wait.
OFF:
Press button,
and countdown time disappear.
NOTE: At end of countdown time period, the re turns o. The
Countdown Timer only works in Manual, Thermostatic, and Eco Modes. Maximum countdown time is 9 hours and 50
44
minutes.
Page 45
OPERATING the FIREPLACE
MODES of OPERATION
AM PM
ON OFF
1 2
AM PM
ON OFF
1 2
AM
THERMOSTATIC MODE
AM PM
ON OFF
1 2
AM PM
ON OFF
1 2
Thermostatic Mode The room temperature is measured and compared to the set temperature. The ame height is then automatically adjusted to achieve the set temperature.
Program Mode PROGRAMS 1 and 2, each can be programmed to go on and o at specic times at a set temperature.
Eco Mode Flame height modulates between high and low. If the room temperature is lower than the set temperature, the ame height stays on high for a longer period of time. If the room temperature is higher than the set temperature, the ame height stays on low for a longer period of time. One cycle lasts approximately 20 minutes.
ON: Press button. displayed, preset temperature displayed briey, and then room temperature displayed.
OFF:
1. Press button.
2. Press or button to enter Manual
Mode.
3. Press button to enter Program Mode.
4. Press button to enter Eco Mode.
SETTING:
1. Press button and hold until
displayed, temperature ashes.
2. To adjust set temperature press or
button.
3. To conrm press button or wait.
PROGRAM MODE
ON:
AM PM
ON
OFF
1 2
Press button. , or , or displayed.
OFF:
1. Press or or button to enter
AM PM
ON OFF
1 2
Manual Mode.
2. Press button to enter Thermostatic Mode.
NOTE: The set temperature for Thermost atic Mode is the temperature
for the on time in Program Mode. Changing the Thermostatic Mode set temperature also changes the on time temperature in Program Mode.
Default settings: ON TIME (Thermostatic) TEMPERATURE: 21 °C (70 °F) OFF TIME TEMPERATURE: “ ” (pilot ame only)
TEMPERATURE SETTING:
1. Press button and hold until
AM PM
ON
OFF
1 2
ashes. and set temperature (setting in Thermostatic Mode) displayed.
2. To continue press button or wait. ,
displayed, temperature ashes.
3. Select o temperature by pressing the
or button.
4. To conrm press button.
NOTE: The on (Thermostatic) and o set temperatures are the same
for each day.
DAY SETTING:
AM PM
ON
OFF
1 2
5. ashes. Press or button to
choose between , , , , , , , , .
6. To conrm press button.
Element4 Gas Fireplaces EuropeanHome.com
45
Page 46
OPERATING the FIREPLACE
WARNING
NOTICE
GENERAL NOTES
Wiring of valve and receiver must be completed before starting ignition. Failure to do so could damage the electronics.
Batteries – Remote
• Low battery indicator on remotes.
Batteries – Receiver
• Low battery indication: frequent beeps for 3 seconds when motor turns.
• Instead of batteries, the included AC adapter should be used for improved reliability and customer satisfaction.
• While not using an AC adapter, battery replacement is
recommended at the beginning of each heating season.
• Old or dead batteries should be removed immediately. If left in the
unit the batteries can overheat, leak, and/or explode.
• Do NOT expose batteries (including during storage) to direct
sunlight, excessive heat, re, moisture, or severe impact. Each of these conditions can cause the batteries to overheat, leak, and/or explode.
• New and old batteries and dierent brands of batteries should
not be used together. Mixing of various batteries can cause the batteries to overheat, leak, and/or explode.
The following Functions can be Deactivated/Activated
• CHILD PROOF (To activate press and buttons simultaneously. displayed and the remote is rendered inoperable (except for
o function).
• PROGRAM MODE
• THERMOSTATIC MODE (also deactivates Program Mode)
• ECO MODE
• LIGHT/DIMMER OPERATION
• CIRCULATING FAN OPERATION
• AUXILIARY FEATURE
• COUNTDOWN TIMER
Automatic Turndown.
1. In Manual/Temperature/Timer modes, the valve will turn to pilot
ame if there is no change in ame height for a six hour period. In Temperature or Timer mode, if the ambient room temperature changes, the ame height will adjust automatically to maintain set temperature and the re will continue to function normally. The valve will turn to pilot ame if the set temperature and the ambient room temperature remain the same over a six hour period.
2. The valve turns to pilot ame if the temperature in the receiver is
higher than 140°F/60°C. The burners comes back on only when the temperature is below 140° F/60°C.
Software Version Press and buttons simultaneously. Software version is displayed.
Remote Model Number Press and buttons simultaneously. Remote model number is displayed.
Deactivate Functions
1. Install batteries. All icons are displayed and ashing.
2. While the icons are ashing, press the relevant function button and hold for 10 sec.
3. The function icon will ash until deactivation is complete. Deactivation is complete when the function icon and two horizontal bars are displayed.
NOTE: If a deactivated button is pressed, there is no function, and
two horizontal bars are displayed.
NOTE: Deactivation remains in eect after change of batteries.
Activate Functions
1. Install batteries. All icons are displayed and ashing.
2. To activate a function, press the relevant button and hold for 10sec.
3. The function icon will continue to ash until activation is complete. Activation is complete when the function icon is displayed.
Automatic Shut O.
1. With low battery power in the receiver, the system shuts o the re completely. This does not happen if the power supply is interrupted.
2. The system shuts o the re completely if there is no change in ame height for 5 days.
3. The system shuts o the re if the main burner does not completely ignite approximately 20 seconds after ignition or after pushing the button.
Element4 Gas Fireplaces EuropeanHome.com
46
Page 47
OPERATING the FIREPLACE
THE FIRST FIRE
When the replace is rst heated, an odor may be given o by the hot metal. This is normal and is a result of the ‘burn o’ of the lubricants and sealants used when manufacturing the replace. We recommend that you open the nearby windows for extra ventilation and then operate the replace for at least four hours.
When the glass is cold, some condensation may appear on the glass after lighting the replace. This is normal and the condensation will disappear as the glass warms.
During this rst re, examine the ame for appearance and quality. Examine the burner media for sooting. The ames should look like those shown below.
After this burn-o period, turn o the replace and let it cool completely to room temperature and clean both sides of the glass and the interior panels as described in the MAINTENANCE section.
Since it is a metal replace, the heat-up and cool-down cycles may produce some noises caused by the expansion and contraction of these metals. The premium materials and build quality of your replace will keep these sounds to a minimum.
To see an Element4 replace starting and running normally
WWW.EUROPEANHOME.COM/RESOURCES/VIDEOS/
Element4 Gas Fireplaces EuropeanHome.com
please visit the link below.
47
Page 48
MAINTENANCE
REMOVING AND CLEANING THE GLASS
OVERVIEW
The glass panels on this replace are held in place by a number of rope gaskets. These instructions will show you how to remove and install the rope gaskets and glass panels.
Please read these instructions completely before proceeding.
TOOLS REQUIRED
• Gloves (not included)
REMOVING THE GLASS
Step 1.
Remove the lower and upright trim pieces which are held in place with magnets and will lift out.
Step 2.
The front glass panel should be removed rst. This panel is secured with one lower rope gasket and one upper rope gasket.
Remove the SIDE TRIM rst, then the BOTTOM TRIM
Step 3.
Once the rope gaskets are out, lift the glass panel up and swing the lower edge of the glass panel out and over the stando frame.
When the glass panel is clear of the stando frame then lower the glass panel out and set the panel securely aside.
Step 4.
Remove all of the rope gaskets holding each remaining glass panel (if applicable). Remove each small glass panel and set aside.
PROPERLY PLACE ROPE GASKET(S) AND SEAL THE GLASS PANEL(S) BEFORE LIGHTING THE FIRE!
Remove the ROPE GASKET starting from one end down to the other end
The ROPE GASKET will be removed for all remaining sides (if applicable)
Element4 Gas Fireplaces EuropeanHome.com
48
Page 49
MAINTENANCE
CLEANING THE GLASS
Burning natural gas (NG) or propane (LP) in this replace will always result in some of the gas components being deposited on the glass. Hydrogen suldes and mercaptans, which are present in the burning gas, condense onto the relatively cooler glass surface and cause white lm to build up over time.
The amount of this white lm is inuenced by a number of factors such as; the conguration of the system venting, thermal eciency of the replace design, the humidity of combustion air, frequency of replace use, burner performance and, the replace design itself.
Do not use normal household (usually ammonia-based) glass cleaners to clean the glass as these cleaners can leave a permanent stain. Only a gas replace glass cleaner should be used. Products such as Stove Bright® Gas Appliance Glass Cleaner by Forrest Technical Coatings, Imperial Gas Fireplace Glass Cleaner by Imperial Manufacturing Group and GFC™ Gas Fireplace Glass Cleaner by A.W. Perkins Co. are designed for this purpose.
Follow the instructions for use and do not clean the glass when it is hot! If the glass becomes coated with deposits which cannot be removed it must be replaced.
The replace glass should be cleaned before the replace is rst lit and then after the replace has been through its four hour burn­in cycle. This will reduce potential build up on your glass.
INSTALLING THE GLASS
The glass panels should be installed in reverse order of their removal.
Step 1.
Lift the glass panel up under the stando frame and swing the lower edge of the glass panel against the rebox gasket. Set a rope gasket into place and secure it from the middle to the left and right sides.
Step 2.
Repeat Step 1 with the remaining glass panels.
Step 3.
Adjust the remaining glass panels left to right until there is no corner gap.
Step 4.
While ensuring that the glass panels are tight and square to each another, carefully install the remaining rope gaskets.
PROPERLY PLACE ROPE GASKET(S) AND SEAL THE GLASS PANEL(S) BEFORE LIGHTING THE FIRE!
Element4 Gas Fireplaces EuropeanHome.com
49
Page 50
MAINTENANCE
Pilot Injector Natural - Marking 31.2 Pilot Injector Propane - Marking 27.1
3mm
WARNING
Installation and maintenance must be performed by an authorized qualied installer, service agency or gas supplier.
TURN OFF THE GAS before servicing the appliance. It is recommended that a qualied service technician perform an appliance check-up/service once a year.
Any safety screen or guard removed for servicing MUST BE REPLACED before operating this appliance.
DO NOT USE this appliance if any part has been under water. Immediately call a qualied service technician to inspect the unit and to replace any part of the control system and any gas valve that has been under water.
Any alteration to the product that causes soot or carbon to form and results in damage is not the responsibility of the manufacturer.
Inspect the external vent cap on a regular basis to make sure that no debris, plants, trees, or shrubs are interfering with the air ow.
BURNER MAINTENANCE
The ames from the burner should be visually checked. The ame should have a blue base and yellow tops and be candle-like in appearance.
PILOT MAINTENANCE
The pilot ame must be visually checked. The pilot ame must always be present when the appliance is in operation and should appear as shown (with hearth panel removed.)
The pilot has two distinct ames, one engulng the thermocouple on it’s left, the other reaching across to the main burner.
The area around the pilot should be inspected for cleanliness. Lint or foreign material must be removed with a brush or vacuum.
Thermocouple
Ignitor Rod
Pilot Assembly
Element4 Gas Fireplaces EuropeanHome.com
Thermocouple
Ignitor Rod
(styles vary)
Pilot Assembly Detail
50
Page 51
MAINTENANCE
Natural Gas Injector - marked 1200 Propane Gas Injector - marked 320
THERMOCOUPLE MAINTENANCE
The Element4 replaces have two thermocouples; one next to the pilot and one opposite the pilot side of the main burner. The completeness and operation of both must be checked. A qualied installer must conrm that both thermocouples are in place and not damaged. While checking the thermocouple, please ensure that the ignitor rod is not cracked as well.
VENT MAINTENANCE
The following venting system inspection by a qualied service technician is recommended every six months:
1. Inspect for excessive condensation, e.g. water droplets forming in the inner lining and subsequently dripping out of the joints. This can cause corrosion in the system.
2. Check for corrosion in areas exposed to the elements. Where rust spots or holes have appeared, these must be immediately replaced.
3. Ensure that there is no foreign material in the vents. Survey by removing the cap and shining a light down the vent.
4. Check all joints and pipes to make sure that nothing has been disturbed or loosened.
REPLACEMENT PARTS
The orice for the burners is shown below. The NG orices are marked 650, LP orices are marked 220.
E4-SA-LPCK-140MKII-01 LP Conversion Kit REPL-E4-GS-1T-01 Replacement Primary Thermocouple REPL-E4-GS-2TC-01 Replacement 2nd Thermocouple REPL-E4-GS-CM-01 Replacement Receiver REPL-E4-GS-RC-01 Replacement Remote Control
Element4 Gas Fireplaces EuropeanHome.com
51
Page 52
WARRANTY
European Home Warranty
Element4 Gas Fireplace
European Home warrants these gas fireplaces against defects in materials and workmanship for a period of ONE (1) YEAR from the date of original retail purchase. Glass is expressly NOT covered by this warranty.
If a defect exists, European Home will, at its option, either (1) provide needed components using new or refurbished replacement parts or (2) exchange the product with one which is new or which has been manufactured from new or serviceable used parts and is at least functionally equivalent to the original product. A replacement product/part assumes the remaining warranty of the original product or ninety (90) days from the date of replacement or repair, whichever provides longer coverage for you. When a product or part is exchanged, any replacement item becomes your property and the replaced item becomes the property of European Home. All warranty claims must be submitted through the dealer from which you purchased the product. Check with your dealer in advance for any costs to you when arranging a warranty call. Shipping and/or delivery charges for parts are not covered by this warranty.
Nothing in the above shall be deemed to imply that this warranty shall apply to work which has been abused or neglected or shows evidence of changes or modifications by others with or without permit, damages caused by the acts of God, building settlement or moving, fire or vandalism. In addition, installation of this product that varies from the requirements stated in the instruction manual will void the warranty.
PRODUCT INSTALLATION RECORD
Installer: Please complete this form. Customer: Please retain this information.
Model (check one) Modore 140 MKII Bidore 140 MKII Trisore 140 MKII
Purchased From
Date of Purchase
Installed By
Date of Installation
Fireplace Serial Number
Fuel Type
Total Venting Horizontal
Total Venting Vertical
Element4 Gas Fireplaces EuropeanHome.com
52
Page 53
APPENDIX ONE
MASSACHUSETTS CERTIFICATION
This appliance is approved for installation in the Commonwealth of Massachusetts. The Board of State Examiners of Plumbers and Gas Fitters has issued approval number G1-0515-495 for this appliance.
The following must be observed when installing the Element4 replaces within the Commonwealth of Massachusetts:
(a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above nished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satised:
1. INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fueled equipment, the installing plumber or gastter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the oor level where the gas equipment is to be installed. In addition, the installing plumber or gastter shall observe that a battery operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of qualied licensed professionals for the installation of hard wired carbon monoxide detectors
a. In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent oor level.
b. In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be installed.
2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above
provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certied.
3. SIGNAGE. A metal or plastic identication plate shall be permanently mounted to the exterior of the building at a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The sign shall read, in print size no less than one-half (½) inch in size, "GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS".
4. INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.08(2)(a)1 through 4.
(b) EXEMPTIONS: The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4:
1. The equipment listed in Chapter 10 entitled "Equipment Not Required To Be Vented" in the most current edition of NFPA 54 as adopted by the Board; and
2. Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building or structure used in whole or in part for residential purposes.
(c) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM PROVIDED. When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the instructions provided by the manufacturer for installation of the equipment and the venting system shall include:
1. Detailed instructions for the installation of the venting system design or the venting system components; and
2. A complete parts list for the venting system design or venting system.
(d) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of a Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the ue gases, but identies "special venting systems", the following requirements shall be satised by the manufacturer:
1. The referenced "special venting system" instructions shall be included with the appliance or equipment installation
instructions; and
2. The "special venting systems" shall be Product Approved by the Board, and the instructions for that system shall
include a parts list and detailed installation instructions.
(e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation.
Element4 Gas Fireplaces EuropeanHome.com
53
Page 54
APPENDIX TWO
TROUBLESHOOTING FLOW CHART
FUNCTION POSSIBLE CAUSE REMEDY
A.
Press UP and OFF
buttons to start igni-
tion sequence. Beep
will occur each
second.
Yes
(continued)
No
Remote batteries low.
Receiver batteries low.
Check that remote and receiver are synchronized.
Remote distance is limited.
Defective AC adapter Replace the AC adapter.
Damaged wiring Inspect/test all wiring and connections.
2nd thermocouple is producing electricity.
Replace remote batteries. Quality alkaline recommended.
Test the batteries. replace if necessary. Quality 1.5V AA alkaline recommended.
Note: Do NOT connect an AC adapter when using receiver batteries.
Reset system, see the installation manual or the label on the receiver. One long beep indicates the wiring is incorrect or the code learning sequence has failed.
Straighten the antenna.
Replace the receiver.
Wait for 2nd thermocouple to cool down (3-5 minutes)
Element4 Gas Fireplaces EuropeanHome.com
54
Page 55
APPENDIX TWO
FUNCTION POSSIBLE CAUSE REMEDY
B.
Magnet unit is
energized thus pro-
ducing an obvious
latching sound.
Yes
No
No
No
No beep
3 short beeps
1 long beep
Impulse magnet not operating properly.
Receiver batteries low.
8-wire cable is o or not operating properly.
SW-cable disconnected.
Motor not operating properly.
Micro switch not operating properly.
ON/OFF switch is in the OFF (O) position.
2nd thermocouple not connected
Replace gas valve.
Test the batteries, replace if necessary. Quality 1.5V AA alkaline recommended.
Conrm proper operation of the 8-wire cable.
Conrm proper connection/operation of the SW-cable.
Replace gas valve.
Replace gas valve.
If equipped, set switch to ON ( | ) position.
Conrm integrity of 2nd thermocouple and connection.
C.
Spark will occur
each second.
Yes
(continued)
No
No
No
No
Check connection between ignition cable and ignition electrode.
Ignition components not operating properly.
Ignition sequence stops after one spark
Ignition sequence stops, no pilot flame. No reaction to remote command.
Ignition sequence stops, no pilot flame. Remote command is possible.
Check ignition electrode spark gap.
Check ignition electrode.
Check ignition cable for damage.
Increase distance between ignition cable and all metal parts.
Remove ground bolt (T20 Torx, above) and clean ground lug.
Reset system, see the installation manual or the label on the receiver.
Do not coil the ignition cable.
Shorten the ignition cable, if possible.
Test the batteries, replace if necessary. Quality 1.5V AA alkaline recommended.
Element4 Gas Fireplaces EuropeanHome.com
55
Page 56
APPENDIX TWO
FUNCTION POSSIBLE CAUSE REMEDY
D.
Pilot lit.
Yes
E.
Sparking stops after
pilot is lit.
Yes
No
No
No
Magnet unit drops (audible sound)
TC- and SW-cable reversed.
Magnet unit not operating properly. Replace gas valve.
Short between interrupter and SW cable. Check interrupter block connection.
No gas (magnet unit drops after 30 second audible count.)
Spark not lighting the pilot. Check spark is crossing pilot orice.
Short between interrupter block and TC­cable.
Electronic measuring amplier defective. Replace the receiver.
Resistance in thermocouple circuit too high.
Not enough heat on thermocouple.
Check cable connection between receiver and interrupter block.
Check gas supply.
Check connection to interrupter block.
Check thermocouple circuit.
Check position of pilot to thermocouple. Check the stability and intensity of pilot ame. Ensure the proper restrictor is installed. Ensure that the pilot ame is properly adjusted. Possible cold start
Replace thermocouple. Do not over tighten ­hand tight plus ¼ turn maximum.
Check gas supply.
Ensure powered/unpowered receiver allows manual operation.
Reset system, see the installation manual or the label on the receiver.
Do not coil the ignition cable.
Remove hearth panel and glass and check for proper pilot operation. If pilot establishes with panel o then install panel and glass and adjust pilot ame (hi/lo) for best operation.
F.
Motor turns to main
gas and pilot stays
lit.
No
No
Low voltage from thermocouple.
No gas (magnet unit drops after 30 second audible count.)
Broken receiver
Ignition sequence stops. No reaction to remote command.
Element4 ‘140’ models ONLY: Pilot ame under hearth panel not establishing.
Yes
(continued)
Element4 Gas Fireplaces EuropeanHome.com
56
Page 57
APPENDIX TWO
FUNCTION POSSIBLE CAUSE REMEDY
G.
Main burner is lit.
Yes
No
No
No
Manual knob is in the “MAN” position.
Pilot ame is too low.
System
‘drops out’
- all ames
immediately
go out
Main burner
remains lit while ames are lowered.
Too much draft at pilot ame (poor ame impingement of primary thermocouple.)
Pilot assembly out of order.
5 day shut o.
2nd thermocouple is not heated.
Turn the control knob to “ON” position, a positive latch is required.
Conrm correct gas pressure. Increase pilot ame if necessary.
Check venting installation. Use restrictor as required.
Inspect pilot assembly for correct operation and thermocouple impingement.
The system shuts o the re and pilot if there is no change in the ame height for 5 days.
Ensure 2nd thermocouple is heated by a robust ame. The replace media may be interfering with proper ame. Check 2nd thermocouple wiring.
H.
Main burner stays
lit.
Yes
(continued)
No
(Main valve
knob is
turned via
motor.)
System goes
to pilot ame
only.
2nd thermocouple shut o.
6 hours of no motor movement.
The system shuts o the re when the main burner ame is not sensed within 22 seconds of ignition or not sensed after pressing the large ame button. Note: If the system fails to light due to the 2nd thermocouple voltage not being sensed a two minute lockout period begins. This lockout time allows the gas to dissipate.
In Manual/Temperature/Timer modes the valve turns down to pilot only if the ame height does not change for a 6 hour period.
In Temperature/Timer modes if the ambient room temperature changes, the ame height will adjust automatically to maintain the set temperature and the re will continue to function normally. The valve will turn to pilot ame if the set temperature and the ambient temperature remain the same over a 6 hour period.
Element4 Gas Fireplaces EuropeanHome.com
57
Page 58
APPENDIX TWO
OPERATION
FUNCTION POSSIBLE CAUSE REMEDY
I.
Magnet unit drops while motor turns.
Receiver makes 3
beeps.
No
J.
Flames become
thin, blue, wispy
then go out.
No
K.
Flames are very
yellow with dark,
sooty tips.
Yes
Yes
Yes
Receiver batteries low.
Ensure magnet unit is operating normally.
Exhaust is contaminating the fresh air.
Flow of fresh air and/or exhaust is blocked.
LP gas being used with NG orice(s).
The air shutter is closed when using LP gas.
Flow of fresh air and/or exhaust is blocked.
Test the batteries, replace if necessary. Quality 1.5V AA alkaline recommended.
Test the receiver output to the magnet unit.
Inspect venting for damage and/or incorrect installation.
Ensure that vent conguration is within the vent chart requirements.
Check termination for blockage and/or appropriate type.
Ensure the gas type is correct for the installed orices.
When using LP gas the air shutter must be fully open. See conversion instructions.
Ensure that vent conguration is within the vent chart requirements.
Check termination for blockage and/or appropriate type.
No
L.
Flames are very
busy and blowing in
an abnormal direc-
tion.
No
M.
Flames are stable but too small and
blue.
No
NORMAL
Yes
Yes
Air leak in the rebox.
Too much primary air.
Check unit for leaks at glass corners or at gaskets.
Check unit for positive relief door seal.
Check venting for complete integrity.
Reduce the primary air opening until ames have blue base and yellow upper two-thirds.
Element4 Gas Fireplaces EuropeanHome.com
58
Page 59
APPENDIX THREE
LP (PROPANE) CONVERSION
Modore 140 MkII, Bidore 140 MkII, Trisore 140 MkII
The E4-SA-LPCK-140MKII-01 LP conversion kit contains these instructions plus the following:
• one Pilot Orice (stamped 27)
• two Main Burner Orices (stamped 220)
Converting your replace to LP gas requires the following:
- a 7 mm box/open end wrench
- a 10 mm box/open end wrench
- a 13 mm box/open end wrench
- a 17 mm box/open end wrench
- a No. 2 Phillips screwdriver
- a pair of small needle nose pliers
- a bright work light
APPLICABLE MODELS
CONTENTS
TOOLS REQUIRED
Loosen the two shutter bolts (7 mm) holding each of the two shutters in place, remove the shutters and tighten the bolts.
Remove the compression nuts (17 mm) from each of the orices and, taking care to not deform the supply tube, slide the supply tube out of the orice.
Loosen the orice locknut (13 mm) and unscrew the NG burner orice from each of the burners
Screw an LP orice into each burner until the orice is aligned with the supply tube.
Connect the supply tube to each of the burner orices and tighten the compression nuts.
Tighten the orice locknuts.
Remove the pilot burner inlet tube (10 mm) from the pilot
burner. See below.
CAUTION: The next step involves small parts which can be easily lost.
Note: The pilot inlet nut is easily reached at the bottom of the replace when the replace is tilted slightly rearward. Take care to stabilize the replace!
WARNING!
This conversion must be done by a licensed
plumber or gastter.
Turn o the gas supply before proceeding.
Begin by reading all instructions thoroughly.
INSTALLATION
These models have a double burner and, therefore, two main burner orices must be replaced.
Remove a long glass panel and carefully store it.
Remove all of the re media.
Remove the six hearth (bottom) panels by removing the ten
retaining bolts then lifting up each of the six panels.
• Remove the six bolts attaching the burner base to the rebox.
Using a 10mm wrench, loosen the pilot inlet nut and remove the pilot burner inlet tube from the pilot burner. The pilot orice then drops out of the pilot burner. See below.
Pilot Burner
Pilot Orice
Pilot Inlet Nut
Pilot Inlet Tube
Element4 Gas Fireplaces EuropeanHome.com
59
Page 60
APPENDIX THREE
Orices and Shutters
Supply Tube
Compression Nut
Shutter
Shutter Bolts
Burner Orice
On the gas valve, between the Manual Knob and the Main Valve Knob is a black plastic cap which hides access to the pressure regulator adjustment screw. Remove black plastic cap to gain access to the pressure regulator adjustment screw. See right.
Connect LP gas supply to replace. Loosen the screw inside the manifold pressure test port and connect the manometer to the port. See photo, right.
Turn on the replace and set the ames to high. While turning the pressure regulator screw, adjust the manifold pressure to that stated in the installation manual.
Turn o the replace, remove the manometer and close the test port screw.
Replace the hearth panels, the burner media and the glass panel. Check for proper replace operation.
Pressure Regulator
Adjustment Screw
(cap removed)
Remove the pilot burner orice and replace it with the LP orice (stamped 27) provided. Take care to observe the proper orientation, shown.
Connect the pilot burner inlet tube and tighten the inlet nut.
To see how to convert the gas on an Element4 replace,
Element4 Gas Fireplaces EuropeanHome.com
Orice Locknut
Manifold Pressure Test Port
please visit the link below.
60
Page 61
APPENDIX FOUR
INSTALLING AN OPTIONAL WALL SWITCH
see Figure 5.1
1. Install a single-gang electrical workbox (not supplied) at the desired location - no more than 26 feet as the cable runs.
2. While keeping the black connector (A) inside the work box, thread the black 4-wire cable through the workbox and bring the red connector (B) to the location of the receiver.
3. Connect the black connector (A) to the wall switch, the red connector (C) to the receiver.
4. Test for proper operation then screw the wall switchplate to the workbox with the two screws provided and attach the faceplate (included).
B
A
Figure 5.1
USING THE WALL SWITCH
see Figure 5.2
Note that, with the wall switch, you can turn the replace on and o and adjust the ames up and down. The rear burner, however, can only be turned on/o with the remote control (model
applicable).
Turn replace ON: Press the ON/OFF button until a short beep conrms the start sequence has begun then release the button.
Increase the ame height: Press and hold the UP button.
Decrease the ame height: Press and hold the DOWN button.
For ne adjustment tap the UP or DOWN button as necessary.
Turn replace OFF: Press the ON/OFF button.
UP
ON/OFF
DOWN
Figure 5.2
Element4 Gas Fireplaces EuropeanHome.com
61
Page 62
APPENDIX FIVE
CONNECTING TO A SMART HOME SYSTEM
GENERAL NOTES
The replace may be operated through an external source such as a smart home (home automation) system by using the 5-pin connector on the receiver.
A required 39”/1000 mm cable, with connector, is available (part number E4-SA-SHSC-02). The overall cable length should not exceed 26’/8000 mm.
Signal relays (gold contacts) or opto-couplers are recommended but not supplied. The E4-SA-SHSC-02 cable must be connected to the three smart home system contacts as shown below.
WARNING
You MUST ensure that the replace is in a safe and ready condition before attempting to operate from a remote source.
SEqUENCE OF OPERATION
• To start ignition, close contacts 1 and 3 simultaneously for 1 second.
• To set the valve to High Fire, close contact 1. To set the valve to Pilot, close contact 3. In each case, the contacts need to be closed for 12 seconds to turn the motor from one end-stop to the other end stop.
• To set the valve to the O position, close contacts 1, 2, and 3 simultaneously for 1 second.
E4-SA-SHSC-02
MOdES OF OPERATION
• Mode 1 - the external source provides “ON“ and “OFF“ operation only. The remote control handset provides all other functions. Note: Even if the re is switched on by the external source, the handset, in the thermostatic mode, controls the room temperature. The room temperature setting of the handset will remain the same for the next ON-cycle of the external source as long as the temperature setting in the handset has not been changed. If the handset is in manual mode, it will go to High Fire in the next cycle of external operation.
• Mode 2 - The handset must be set to the manual mode if the external source is to control the room temperature. If the handset is placed in the thermostatic mode it will override the external source.
NOTE:
Frequent ON and OFF cycles will limit life expectancy of the valve and will increase battery consumption. The replace should be powered by the AC adapter for improved reliability and customer satisfaction.
Element4 Gas Fireplaces EuropeanHome.com
62
Page 63
INDEX
A
APPLIANCE RATINGS 8 AC AdAPTER SPECIFICATIONS 8
C
CERTIFICATION
Listing LabeL 8 Massachusetts 57
CLEARANCES
Location 14 ManteLs 16 WarM air outLet(s) 17
E
ELECTRIC
requireMents 18 ac adapter specifications 8
ENCLOSING ThE FIREPLACE 25
F
FIRE MEdIA
instaLLing the Logset 37 instaLLing the stones 38
FIRST FIRE 47
G
GAS
converting to Lp 59 instaLLing the gas Line 18 pressures 8
K
O
OPERATING ThE FIREPLACE
test fi re 36 using the reMote controL 43 using the WaLL sWitch 61
P
PARTS OF ThE FIREPLACE 12
S
SAFETY INFORMATION 3 SCREEN INSTALLATION 39 SMART hOME SYSTEM 62 SPECIFICATIONS
appLiance ratings 8 diMensions - Modore 140 MKii 9 diMensions - bidore 140 MKii 10 diMensions - trisore 140 MKii 11
T
TROUbLEShOOTING 54
V
vENTING
configuration 19 horizontaL terMinations 22 verticaL terMi nations 22 restrictors 21
W
WARRANTY 52
KEY INSTALLATION POINTS 6
L
LISTING LAbEL 8 LP (PROPANE) CONvERSION 59
M
MAINTENANCE
burner 50 piLot 50 therMocoupLes 51 vent 51
MANTELS 16
N
NON-COMbUSTIbLE MATERIALS
MiniMuM cLearances 15
Element4 Gas Fireplaces EuropeanHome.com
63
Page 64
Imported and distributed in North America by:
EUROPEAN HOME
a division of Europa Ja, Inc.
376 Washington Street
Suite 203
Malden, MA 02148
www.europeanhome.com
Element4 Gas Fireplaces EuropeanHome.com
IGE410II -16 0 401A
64
Loading...