HOT GLASS WILL Une surface vitrée chaude
CAUSE BURNS. peut causer des brûlures.
DO NOT TOUCH GLASS Laisser refroidir la surface
UNTIL COOLED. vitrée avant d’y toucher.
NEVER ALLOW CHILDREN Ne permettez jamais á un enfant
TO TOUCH GLASS. de toucher la surface vitrée.
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed
for the protection of children and other at-risk individuals.
Une barrière conçu pour réduire le risque de brûlure par le verre de visualisation chaude est fournie avec cet appareil et doit
être installé pour la protection des enfants et autres personnes à risque.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could
result in serious injury, death, or property damage.
AVERTISSEMENT:
INCENDIE OU D’EXPLOSION
Le non-respect des avertissements de sécurité à la
lettre pourrait entraîner de graves blessures , la mort
ou des dommages matériels.
- Do not store or use gasoline or other ammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
• If you cannot reach your gas supplier, call
the re department.
- Installation and service must be performed
by a qualied installer, service agency or the
gas supplier.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Element4 Gas Fireplaces EuropeanHome.com
- Ne pas entreposer ni utilizer d’essence ni d’autres vapeurs
ou liquides inammables dans le voisinage de cet appareil
ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ
• Ne pas tenter d’allumer d’appareil.
• Ne touchez á aucan interrupteur. Ne pas vous servir des
téléphones se trouvant dans le bátiment ou vous trouvez.
• Quitter immédiatement le bâtiment.
• Appelez immédiatment votre fournisseur de gaz depuis
un voisin. Suivez les instructions du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz
appelez le service des incindies.
- Installation et l’entretien doivent être effectués par un
installateur qualié, une agence de service ou le fournisseur
de gaz.
INSTALLATEUR: Laissez cette notice avec l’appareil.
CONSOMMATEUR: Conservez cette notice pour
consultation ultérieure.
1
4006 611
April 1, 2016
Page 2
TABLE OF CONTENTS
Important Safety Information 3
Key Installation Points 6
User Information 7
Specications and Dimensions 8
Modore 140 MKII 9
Bidore 140 MKII 10
Trisore 140 MKII 11
Parts of the Fireplace 12
Clearances 14
Gas and Electric 18
Venting 19
Conguration 19
Venting Charts 22
Venting Clearances 23
Enclosing the Fireplace 25
Non- combustible Materials List 25Rough Opening Dimensions 28
Convection Air Opening 32
Installing the Fire Media 37
Screen Installation 39
Operating the Fireplace 42
Maintenance 48
Glass 48
Burner 50
Pilot 50
Thermocouple 51
Venting 51
Replacement Parts 51
Warranty 52
Massachusetts Certication Appendix One
Troubleshooting Flowchart Appendix Two
LP Conversion Appendix Three
Installing the Optional Wall Switch Appendix Four
Connecting To A Smart Home System Appendix Five
Index ---
Page 3
IMPORTANT SAFETY INFORMATION
CAUTION - HOT! HOT! HOT!
This appliance is a HEATING appliance and it does become very hot in operation.
UNDER ANY CIRCUMSTANCES, DO NOT PLACE any object, furniture, draperies or other item LESS THAN 36”/90 cm IN
FRONT OF THE GLASS OF THE FIREPLACE.
CHILDREN AND PETS
Radiant heat can heat surfaces such as the surround and trims of the replace to temperatures that, although approved
safe, can be quite uncomfortable to touch - particularly for children and pets. Children and pets should always be
supervised when in the room where the appliance is located. Remote control handset should be kept out of reach of
children. In the presence of children, we STRONGLY RECOMMEND that you install in front of the replace: a re screen or,
to protect young toddlers, a “hearth gate”.
HOT SURFACES
Be aware that, although safe, some combustible materials and nishes, even though
installed at listed clearances may, over time, discolor, warp or show cracks.
Convective heat will exit the unit and travel up the wall surface if not impeded. Protruding
mantels and projections can help direct the heat away from the wall. AVOID placing heat
sensitive items such as televisions, paintings, decorations, etc. above replaces or near the
edge of protrusions unless appropriate.
Do not place furniture or other objects
within 36” of the replace glass.
SAVE THESE INSTRUCTIONS
Make yourself fully aware of all the following instructions and the many features of the Element4
direct vent gas replace appliance.
INSTALLER: Leave this manual with the appliance.
OWNER: Keep this manual for future reference.
Element4 Gas Fireplaces EuropeanHome.com
3
Page 4
IMPORTANT SAFETY INFORMATION
WARNING
Children and adults should be alerted to the hazards of
high surface temperature and should stay away to avoid
burns or clothing ignition.
WARNING
This direct vent system appliance must be installed as an
OEM installation in manufactured homes (USA only) or
an aftermarket permanently located, or a mobile home,
where not prohibited by local codes and must be
installed in accordance with Manufacturer’s instructions
and the Manufactured Home Construction and Safety
Standard, Title 24 CFR, Part 3280, in the United States, or
the Standard for Installation in Mobile Homes, CAN/CSA
Z240 MH Series, in Canada.
WARNING: Installation and Service
Installation and service must be performed by an
authorized qualied installer, service agency or gas
supplier.
Any alteration to the product that causes soot or carbon to
form and results in damage is not the responsibility of the
manufacturer.
ONLY a qualied person may open the door/remove the
glass.
Do not modify or substitute any part of this appliance.
WARNING: Electrical Grounding
These direct vent appliances must be electrically
grounded in accordance with the local codes or, in the
absence of local codes, with National Electric code, ANSI/
NFPA 70, or the Canadian Electric Code, CSA C22.1
If the information in these instructions is not followed
exactly a re or explosion may result causing property
damage, personal injury or death.
Do not store or use gasoline or other ammable vapors
and liquids in the vicinity of this appliance.
WARNING: Glass Handling
The glass must only be removed by a qualied person.
Gloves should be worn when removing the glass.
WARNING: Gas Appliance
This appliance is only for use with the type of gas
indicated on the rating plate. These appliances are not
convertible for use with other gases unless a certied kit
is used and the conversion is performed by an authorized
qualied technician.
Applicable standards are ANSI Z21.50/CSA 2.22 (Vented
Gas Fireplaces) and CAN/CGA 2.17-M91 (Gas-red
Appliances for Use at High Altitudes.) If your installation
is at an elevation greater than 2000’ in the US or 4500’
in Canada, consult with the local authority having
jurisdiction for gas product installations to determine their
specic requirements for high altitude installations.
Element4 Gas Fireplaces EuropeanHome.com
4
Page 5
IMPORTANT SAFETY INFORMATION
This gas replace and vent assembly MUST be vented
directly to the outside and MUST NEVER be attached to a
chimney serving a separate solid fuel burning appliance.
Each gas appliance MUST BE a separate vent system.
Common vent systems are prohibited.
This unit MUST be used with a vent system as described
in this installation manual. NO OTHER VENT SYSTEM OR
COMPONENTS MAY BE USED.
INSPECT the external vent cap on a regular basis to make
sure that no debris, plants, trees, or shrubs are interfering
with the air ow.
TURN OFF the gas before servicing the appliance. It is
recommended that a qualied service technician perform
an appliance check-up/service once a year.
Any safety screen or guard removed for servicing MUST BE
REPLACED before operating this appliance.
THIS UNIT IS NOT FOR USE WITH SOLID FUEL, and must
only be used with gas supply conditions as indicated on
the rating label.
DO NOT USE this appliance if any part has been under
water. Immediately call a qualied service technician to
inspect the unit and to replace any part of the control
system and any gas control that has been under water.
NEVER OBSTRUCT the ow of ventilation air. Keep the
front of the appliance CLEAR of all obstacles and materials
for servicing and proper operation.
The glass panels MUST be in place and sealed before the
unit can be placed into safe operation.
DO NOT OPERATE this appliance with the glass panels
removed, cracked or broken. Replacement of the glass
panels should be performed by a licensed or qualied
service person. DO NOT strike or slam the glass panels.
The glass panels SHALL ONLY be replaced by units
supplied by the manufacturer. NO SUBSTITUTE panels
shall be used.
DO NOT USE abrasive cleaners on the panels. DO NOT
ATTEMPT to clean the glass panels when they are hot.
DO NOT use this appliance as a temporary source of heat
during construction.
This appliance is a vented gas replace. It must not be
used for any other purposes such as drying clothes, etc.
If the pilot ame is extinguished either intentionally or
unintentionally, no attempt should be made to re-light the
gas until at least 3 minutes have elapsed.
Dimensions will appear as INCHES”/metric throughout
this manual. For convenience, the inches are rounded to
the nearest 1/16” when converted. If greater accuracy is
required, use the metric dimensions.
Element4 Gas Fireplaces EuropeanHome.com
5
Page 6
KEY INSTALLATION POINTS
IMPORTANT
INFORMATION
This page references the most important key installation points when installing any Element 4 replace. This
page DOES NOT substitute for reading the entire manual.
RECORDS
•The installer MUST record the serial number and venting conguration to use for any technical issues that
may arise.
ELECTRICAL
• The receiver MUST be powered by either the AC adapter or 4 (AA) batteries, NEVER both at the same time.
FIRE MEDIA
•When installing the re media make sure to NEVER mix dierent types of media or use media purchased
from another retailer. ALWAYS keep the second thermocouple AND pilot free from media.
CONVECTION AIR
• The convection air outlets MUST be installed BEFORE the rst light. The amount of square inches needed
for the opening varies from model to model.
ENCLOSING THE FIREPLACE
•ONLY a tested and approved non-combustible wallboard that is specied in the manual may be used when
enclosing the replace.
VENTING
•The venting MUST follow the model specic graph shown in the manual. A restrictor may or may not need
to be used based on venting run and rise.
CONSTRUCTION DEBRIS
• REMEMBER that if the replace is installed before the site is nished, construction debris MUST be cleaned
from the enclosure and around the unit prior to nishing and the test re.
GAS PRESSURES
• Gas pressures MUST be read with a manometer and conrmed with what is required in the installation manual.
FINISHING
• A ⁄”/3 mm gap between the ange and the enclosing wallboard MUST be maintained to prevent cracking
from heat expansion and contraction.
Element4 Gas Fireplaces EuropeanHome.com
6
Page 7
USER INFORMATION
WARMTH AND BEAUTY HOW IT WORKS
The Element4 replaces are direct vent replaces and, as such, the intake and exhaust are both handled through the vent pipe. The
replace also provides convection air to your room. The illustration shows one of the unique features of the Element4 replaces - its
use of warm, convection air ow.
Other replaces have louvered metal boxes around them to keep temperatures under control. The Element4 replaces use your
enclosing walls, or chase, to guide this warm air. This design, therefore, requires the use of non-combustible wall materials and gives
you beauty for your eort.
When the air within the chase is warmed by the replace, it rises and exits through the Convection Air Outlet. This chase air is then
replaced by room air which enters the chase through the Room Air Inlet and through the Wall Access Door. As the exiting warm air
cools, it falls to the oor where it's drawn into the inlets and the cycle repeats.
The replace provides the inlet for room air as part of its design; you provide the warm air outlet as part of your design.
See the ENCLOSING the FIREPLACE section of this manual for more information.
Warm Air Out
Room Air In
Warm Air Out
Site-built Chase
Room Air In
Element4 Gas Fireplaces EuropeanHome.com
Access Door
Room Air In
7
Page 8
APPLIANCE RATINGS
SPECIFICATIONS and DIMENSIONS
Modore 140 MKII
Model
Bidore 140 MKII
Trisore 140 MKII
GasNatural GasPropane
Input MaximumBtu/hr38,20034,100
Input MinimumBtu/hr13,65011,950
Maximum Supply
Pressure
Minimum Supply
Pressure
Manifold Pressure
Maximum
Manifold Pressure
Minimum
in. w.c.711
kpa1.742.74
in. w.c.48
kpa12
in. w.c.4.010.8
kpa0.992.68
in. w.c.0.41.5
kpa0.10.38
Main Burner Injector Marking650 (x2)220 (x2)
Pilot Injector Marking31.227.1
Eciency80.6%
DO NOT REMOVE
DIRECT VENT GAS FIREPLACE - Not for
use with solid fuel.
This appliance is only for use with the type of gas indicated on the
rating plate and may be installed in an aftermarket, permanently
located, manufactured home (USA only) or mobile home where
not prohibited by local codes. See owner’s manual for details. This
appliance is not convertible for use with other gases, unless a
certied kit is used.
For use only with Vent, Glass Panels and Ceramic Logs (or
stones) certied and approved for use with this appliance.
This appliance must be installed in accordance with local codes,
if any; if none, follow ANSI Z223.1/NFPA 54, or CSA B149.1. The
appliance must be properly connected to a venting system in accordance with the manufacturer’s installation instructions.
The system must be installed by ba qualied installing agency.
SAMPLE
Manufacturer/ Fabricant:
Element4 B.V.
Paxtonstraar 23
NL-8013 RP Zwolle
The Netherlands / Pays-Bas
Tel / Tél : 0031 38 4209020
Fax:0031 38 4209021
Product name: (check one) / Nom du produit : (cochez …)
Trisore 100H [ ] Bidore 100H [ ]
Modore 100H [ ]
Serial No. / N° de série: _____________
This appliance equipped only for altitudes /
Cet appareil est équipé uniquement pour les altitudes : 0-4500 ft / 0-1370 m
Fuel Type / Type de combustible Natural Gas / Propane Gas /
Gaz naturel Gaz propane
(check one) / (cochez…) [ ] [ ]
Min. Input / Capacité d’entrée mini (BTU/HR) 15025 17075
Gas Inlet Pressure (in w.c.) / Pression d’entrée du gaz (en w.c.) 7 11
Manifold Pressure (in w.c.) / Pression d’admission (en w.c.) 2.1 7.4
Orice Size / Taille de l’ouverture 650 (x2) 180 (x2)
Clearances to combustible / Dégagement jusqu’au combustible :
Back / Arrière : 11” (28cm) Sides / Côtés : 11” (28cm)
Top / Haut : 26” (66cm) Floor / Sol : 4” (10cm)
Mantel / Linteau : 2” (5cm)
NE PAS RETIRER
FOYER GAZ À AÉRATION DIRECTE - Ne pas
utiliser avec un combustible solide
Cet appareil est destiné uniquement avec le type de gaz indiqué sur
la plaque signalétique et peut être installé dans une habitation en dur,
à emplacement xe (USA uniquement) ou dans une résidence mobile
si la législation locale l’autorise. Consultez le manuel du propriétaire
pour les détails. Cet appareil ne doit pas être modié pour une utilisation avec d’autres gaz, sauf à l’aide d’un kit certié.
À utiliser uniquement avec des ventilations, panneaux en verre et
poutres (ou pierres) en céramique dont l’utilisation est autorisée avec
cet appareil.
Cet appareil doit être installé conformément à la législation locale. À
défaut d’une telle législation, suivre ANSI Z223.1/NFPA 54, ou CSA
B149.1. L’appareil doit être proprement raccordé à un système de
ventilation, conformément aux instructions d’installation du fabricant.
Le système doit être installé par un installateur qualié.
Approved By / Approuvé par:
Control No. : 4006611
Conforms to std. ANS Z21.50a-2008
Certied to std. CSA 2.22a-2008 - Vented Gas Fireplaces
AC ADAPTER SPECIFICATIONS
Input Voltage120 V AC
Element4 fireplace and contains important certification
information. It must not be removed from the replace.
Input Power9 W
Output Voltage6V DC
Output Current500 mA
Size3.1”H x 2”W x 1.7”D
Output Cord Length6 Feet
Agency ApprovalsUL, CSA
AC Adapter Connection (arrow)
AC Adapter
A typical rating label is shown above. It is attached to every
Element4 Gas Fireplaces EuropeanHome.com
8
Page 9
SPECIFICATIONS and DIMENSIONS
Modore 140 Mk II Planning Dimensions
11/2015
Element4 B.V.EuropeanHome.com
manufactured bydistributed by
MODORE 140 MKII
Front Elevation
Letter Inches Millimeters
A58⁄1488
B54⁄1386
C54⁄1386
D16½419
E44⁄1138
F50¾1288
G55½1410
H56⁄1446
I13⁄338
Right Elevation
Plan View
J28⁄714
K27⁄700
L11⁄282
M4⁄118
N16⁄423
O10⁄275
P4⁄105
Q1⁄27
A DWG les is available for download at www.europeanhome.com for design specic dimensions not listed.
Element4 Gas Fireplaces EuropeanHome.com
MODORE 140 MKII
9
Page 10
SPECIFICATIONS and DIMENSIONS
Bidore 140 Mk II Planning Dimensions
11/2015
Element4 B.V.EuropeanHome.com
manufactured bydistributed by
BIDORE 140 MKII
Front Elevation
Letter Inches Millimeters
A58⁄1496
B571447
C54⁄1388
D54⁄1388
E16⁄421
F44⁄1138
G50¾1288
H551397
I4⁄105
J26½672
K12⁄326
L10⁄277
Right Elevation
M4⁄118
N9¼234
O10⁄270
P13⁄338
Q56¾1441
R58⁄149 6
S11278
T½12
Plan View
A DWG les is available for download at www.europeanhome.com for design specic dimensions not listed.
Element4 Gas Fireplaces EuropeanHome.com
BIDORE 140 MKII
10
Page 11
SPECIFICATIONS and DIMENSIONS
Trisore 140 Mk II Planning Dimensions
11/2015
Element4 B.V.EuropeanHome.com
manufactured bydistributed by
Front Elevation
Right Elevation
TRISORE 140 MKII
Letter Inches Millimeters
A59⁄1507
B58⁄1475
C54½1383
D55⁄1400
E44⁄1138
F50¾1288
G13⁄338
H59⁄1506
I11½291
J28⁄714
K27⁄700
L12¾324
M4⁄118
N8⁄224
O16⁄420
P10⁄275
Q1⁄47
R4⁄105
S½13
Plan View
A DWG les is available for download at www.europeanhome.com for design specic dimensions not listed.
Element4 Gas Fireplaces EuropeanHome.com
TRISORE 140 MKII
11
Page 12
SPECIFICATIONS and DIMENSIONS
PARTS OF THE FIREPLACE
The various parts of the 140 MKII Series replaces are shown below. These parts are typical of any Element4 replace.
12
11
1
6
2
7
5
8
9
10
3
Table of Fireplace Parts
Outer Frame Face - surrounds the glass panels and limits the non-combustible wall board
Support Feet - four adjustable feet allow the replace to be levelled
3
Hearth Panel - supports various Fire Media
4
Primary Burner - produces the ame
5
Flange
6
Pilot Burner - the part of the safety circuit which lights the Main Burner
7
2nd Thermocouple - the part of the safety circuit which monitors the Main Burner
8
Finish Trim - hides the Glass Clamps
9
Glass Rope Gaskets - holds the Glass Panel in place (2 ea. - Modore, 3 ea. - Bidore, 4 ea. - Trisore)
10
Vent Collar - accepts the 5” x 8” venting adapter (included)
11
Relief Door - part of the safety system. Do NOT block the operation.
12
Pilot Assembly
13
Upright Trim - (2 ea. - Modore, Bidore, Trisore)
14
Element4 Gas Fireplaces EuropeanHome.com
13
Page 14
CLEARANCES
These are NOT zero-clearance fireplaces. All clearances to
combustible AND non- combustible materials MUST be maintained
as described in this manual.
LOCATING THE FIREPLACE
When selecting a location for the replace:
• Ensure that all minimum clearances to combustible AND noncombustible materials are met.
• Provide adequate clearances for servicing.
• Consider venting dimensions (rise, run and number of
elbows, etc.) when selecting the location for your replace.
• Locate the appliance out of trac and away from furniture
and draperies.
• Keep the location free of electrical, plumbing or other
heating/air conditioning ducting.
PLACING THE FIREPLACE
The base upon which the appliance rests must be sturdy, level
and built to safely support at least 500 pounds/230 kilograms.
The base may be the oor or a purpose-built raised platform, e.g.
wood, metal. When placed on a platform, an 8”/203 mm x 6”/152
mm opening must be cut through the platform top. The lineset
can be routed through this opening. Room air must be allowed
to ow through the Wall Access Door then through this opening.
MINIMUM CLEARANCE TO COMBUSTIBLES
• The appliance is approved with a minimum clearance to
combustible materials of 26”/660 mm to the top, 11”/280
mm on all sides and 4”/100 mm to the bottom. Any spacer
or framing used closer than this dimension must be noncombustible (e.g. metal).
• The minimum distance from the bottom of the appliance to
the room ceiling is 72”/1830 mm.
• When installing the venting, the following clearances to
combustible materials MUST be maintained:
a. 3”/76 mmabove any horizontal venting
b. 1”/25 mmto venting sides or below any horizontal
venting
• Do not block or restrict the Room Air Inlet, located between
the stando frame and glass.
The minimum clearances (air spaces) to combustible materials
must be maintained. It is of the greatest importance that the
replace and vent system be installed only in accordance with
these instructions.
Clearance to combustibles summary:
Back: 11”/280 mm
Sides: 11”/280 mmTop: 26”/660 mmFloor: 4”/100 mm
The feet on the appliance are designed to sit on a at platform,
however the appliance must not be installed on any combustible
material other than wood. For example, carpet or linoleum bases
are not permitted.
Do not place anything between the bottom of the rebox and the
bottom of the feet.
ENSURE THAT THE LINESET (WHICH INCLUDES THE GAS
VALVE, ELECTRICAL WIRING, AND GAS LINES) DOES NOT
IMPEDE THE FULL OPERATION OF THE RELIEF DOORS (if
applicable). IT IS YOUR RESPONSIBILITY TO ENSURE THE
SAFETY OF THESE CRITICAL COMPONENTS THROUGHOUT
THE INSTALLATION PROCESS.
The Floor dimension (above) is measured from the bottom of
the rebox. When the adjustable feet are in their lowest position
the required clearance to the oor is maintained.
Element4 Gas Fireplaces EuropeanHome.com
14
Page 15
CLEARANCES
140 MKII SERIES
140 MKII SERIES
CLEARANCES TO COMBUSTIBLE MATERIAL
Clearances to Combustibles
Sides (Non-Glass Sides ONLY)11”
Top26”
Bottom4”
CLEARANCES TO NON-COMBUSTIBLEMATERIAL
Clearances to Non-Combustibles
Sides (Non-Glass Sides ONLY)2”
Top2”
Bottom4”
No material of any kind is allowed between the bottom of the support feet and the bottom of the rebox (except for the
lineset).
No material of any kind is allowed within 2”/50 mm from the top of the replace.
No material of any kind is allowed within 2”/50 mm from the metal sides the replace.
Facing material should be installed against the outer frame of the replace, with an ⁄”/3 mm vertical or horizontal clearance
TO THE FLANGE allow for heat expansion.
Non-combustible materials may be installed to a zero clearance to the outer faces of the appliance outer frame face. However,
they must not cover (or prevent the removal of) the glass panels or other replace parts.
Below the feet materials may be combustible (except for the use of linoleum or carpeting of any type).
These clearances are the same for ALL Element 4 Fireplaces, regardless of model.
Please refer to the “Reduced Clearance to Existing Combustible Wall” section for use of combustibles inside of the above clearances.
Element4 Gas Fireplaces EuropeanHome.com
15
Page 16
CLEARANCES
(2") 50
C
SECTION
A-A
900
COMBUSTIBLE MATERIALSNOT PERMITTED IN FRONTOF GLASS
MANTELS
The graph below shows a range of allowable depths and heights for a combustible mantel installation.
As shown, the minimum allowable mantel height above the replace opening is 2”/50 mm with a 1”/25 mm deep mantel.
The maximum mantel depth is 12”/300 mm at a minimum height above the replace opening of 13”/330 mm.
All of the mantel height/depth combinations fall in between these extremes in accordance with the chart below.
Mantels made of non-combustible material are allowed inside these dimensions but they will be subjected to elevated
temperatures and may become too hot to touch.
A typical completed installation with mantel is shown in the diagram below, on the right.
INCHES
13”/330 mm
Mantel Height
Mantel Depth
12”/300 mm
1”/25 mm
2”/50 mm
Element4 Gas Fireplaces EuropeanHome.com
16
Page 17
CLEARANCES
TYPICAL CLEARANCE DIAGRAMS
The total area of the convection air outlet(s) depends on the replace model. The location of the outlet(s) must allow for the free
movement of air and must not allow excessive convection air to build up within the chase.
The top of the outlet(s) must be at least 1”/25 mm down from the room ceiling and we recommend no more than 3”/76 mm down.
The top of the outlet(s) must be no more than 1”/25 mm down from the chase ceiling.
The minimum distance from the bottom of the appliance to the room ceiling is 72”/1830 mm.
B
Convection
Air Outlet
Minimum Distances
Room ceiling to
A
appliance bottom
Room ceiling to top of
B
Convection Air Outlet1”25 mm
72”
1830 mm
A
Convection Air Outlet Area by Model
Model Square Inches Square Centimeters
Modore 140 MKII70452
Bidore 140 MKII70452
Trisore 140 MKII70452
Element4 Gas Fireplaces EuropeanHome.com
17
Page 18
GAS and ELECTRIC
INSTALLING THE GAS LINE
Correctly size and route the gas supply line from the supply regulator to the area where the appliance is to be installed as per
requirements outlined in the latest edition of the National Fuel Gas Code, NFPA 54 (USA) or CAN/CSA-B149.1 (Canada).
Never use galvanized or plastic pipe unless specied for use with gas. Refer to the table below for proper sizing of the supply gas
line. Gas lines must be routed, constructed and made of materials that are in strict accordance with local codes and regulations. A
qualied plumber or gas tter should be hired to correctly size and route the gas supply line to the appliance.
Installing a gas supply line from the fuel supply to the appliance involves numerous considerations of materials, protection, sizing,
locations, controls, pressure, sediment trap, and other criteria. The sizing and/or installing of gas piping should only be performed
by a qualied plumber or gastter.
The gas control inlet accepts a ⁄” NPT tting.
This replace is shipped from the factory for use with natural gas. See appendix for LP (propane) conversion instructions.
Schedule 40 Black Iron Pipe
Length (feet)Inside Diameter (Inches)
0 - 10½⁄
10 - 40½½
40 - 100½½
100 - 150¾½
150 - 200¾½
Natural
Gas
Propane
Gas
ELECTRICAL REQUIREMENTS
The Element4 replaces use a receiver and remote control for their burner operation. The remote control comes with (3) AAA
batteries and the receiver is powered by a 120V AC adapter, included. The replace should be powered by the AC adapter for
improved reliability and customer satisfaction.
The installer must provide an approved 120V AC wall receptacle to be placed within the six foot cord limit of the AC adapter.
The receiver may be powered by either the AC adapter or (4) AA batteries - not both.Batteries do not provide an electrical backup
for the AC adapter. Using batteries in combination with the AC adapter can lead to a damaged receiver.
Electrical work must be performed by a qualied, licensed electrician.
WARNING
Element4 Gas Fireplaces EuropeanHome.com
All wiring shall be in compliance with all local, city, and state codes.
18
Page 19
VENTING
CONFIGURATION
CONFIGURING THE VENTING
The replaces in this manual are direct vent replaces that use a co-axial or “pipe within a pipe” venting system. The outer “pipe” or vent
conducts fresh, outside air into the replace and the inner vent carries the exhaust outside. This system, which can run either horizontally
through a side wall or vertically through the roof, produces an ecient system because conditioned building air is not used for combustion.
• Only the 5” x 8” direct vent components from M&G DuraVent are approved for use with these replaces. Any of the M&G
DuraVent 5” x 8” direct vent components suitable for the local condition are permitted. Please visit www.europeanhome.com/
qr-support or via the QR code below for installation instructions.
• This replace is shipped with a North American venting adapter. It MUST attach to the vent collar of the replace.
• All venting measurements are taken from the top center of the vent collar on the top of the replace and all congurations
must fall within the acceptable range of the venting charts.
• A minimum clearance of 3”/75mmmust be maintained between combustible materials and the top of any horizontal vent
pipe surface; a minimum clearance of 1”/25mmmust be maintained between combustible materials and any other vent pipe
surface.
• The horizontal parts of the venting must be pitched up away from the replace. For every 12” / 305mmof horizontal run, the
venting must rise ¼” ⁄ 6.5mmtoward the termination. The venting must never run downward unless with the use of a power
vent.
• Whenever venting passes through a wall, an approved heat shield or ‘wall thimble’ must be installed.
• A power vent system is available for venting that falls outside of the venting graphs. Refer to the appropriate power vent
manual for any venting conguration which is outside of the vent graphs shown here.
• Your venting needs to be inspected annually, including any connected components, to ensure that the system is working as
designed.
APPROVED MANUFACTURERS and COMPONENTS
ManufacturerComponents
M&G DuraVent, Inc.*
For the M&G venting installation guide or power venting installation manuals
please visit the link below.
www.europeanhome.com/qr-support
only DirectVent Pro®
5” x 8” venting components
Element4 Gas Fireplaces EuropeanHome.com
19
Page 20
VENTING
CONFIGURATION
R
R
N
N
S
T
N
S
N
N
S
T
S
Q
T
R
N
S
Vertical or Horizontal Vent TerminationR
45 or 90 degree bends Vertical to Horizontal or vice versaN
45 and 90 degree bends Horizontal to HorizontalQ
Horizontal Pipe SectionT
Vertical Pipe SectionS
CALCULATING THE TOTAL VERTICAL SECTION (TVS)
Calculate the Total Vertical Section by adding up all vertical upward sections in your specic vent design.
CALCULATING THE TOTAL HORIZONTAL SECTION (THS)
Calculate the Total Horizontal Section by adding up all vertical upward sections in your specic vent design.
Element4 Gas Fireplaces EuropeanHome.com
20
Page 21
VENTING
CONFIGURATION
BEWARE OF ELBOWS
Elbows do not help the movement of air through your venting conguration and must be included when determining your minimum
and maximum vent lengths.
45° elbows are calculated as either vertical or horizontal depending on positioning.
There are (2) types of elbows:
TYPE N 45° and 90° elbows from vertical to horizontal and vice versa
-The rst (3) N elbows do not need to be included in venting calculations.
-For every extra N elbow, you must add 40”/(1m) to your THS
TYPE Q 45° and 90° elbows from horizontal to horizontal
-For each 90° elbow in the horizontal section you must add 80”/(2m) to your THS
-For each 45° elbow in the horizontal section you must add 40”(1m) to your THS
INTERPRETING THE GRAPH RESULTS
Once you have found your total vertical section (TVS) and your total horizontal section (THS) determine where you vent
conguration will terminate on the corresponding venting chart (shown on the next page).
These venting numbers will correlate as follows:
x
If your venting conguration lands on a block with an “X” the conguration is not possible.
For venting congurations that land on an “X” a power vent option may be available.
CALCULATING THE TOTAL VERTICAL SECTION (TVS)
Calculate the Total Vertical Section by adding up all vertical upward sections in your specic vent design.
CALCULATING THE TOTAL HORIZONTAL SECTION (THS)
Calculate the Total Horizontal Section by adding up all vertical upward sections in your specic vent design.
INSTALLING A RESTRICTOR
Some vent congurations may require a restrictor plate be installed. The restrictor for this replace is installed on the inside top of
the replace and is to be slid open or closed. Loosen the screws on either side and slide the restrictor as desired. Do not modify the
restrictor(s). Please use the graph above to determine if you will need to use a restrictor.
Loosen thes e (2) Phillip’s head screws
to slide on/o the restrictor.
35 mm
Element4 Gas Fireplaces EuropeanHome.com
21
Page 22
VENTING
HORIZONTAL TERMINATIONS & RESTRICTOR USE
rise
VENTING CHARTS
run
VERTICAL TERMINATIONS & RESTRICTOR USE
rise
KEY
x
Element4 Gas Fireplaces EuropeanHome.com
run
22
Page 23
VENTING
HORIZONTAL VENT TERMINATION CLEARANCES AND REQUIREMENTS
CLEARANCES
Element4 Gas Fireplaces EuropeanHome.com
23
Page 24
VENTING
CLEARANCES
VERTICAL TERMINATION CLEARANCES AND REQUIREMENTS
Important Note for Roof Terminations
These instructions should be used as a guideline and do not supersede local codes in any way. Install venting according to local
codes, these instructions, the current National Fuel Gas Code (ANSI Z223.1 in the USA) or the current standard of CAN/CSA-B149.1
in Canada.
A second termination may be no closer than 12”/305 mm.
Element4 Gas Fireplaces EuropeanHome.com
Termination Heights
Multiple Termination Clearance
24
Page 25
ENCLOSING the FIREPLACE
COMBUSTIBLE MATERIALS
Materials that can catch re and burn are considered combustible. Any material that is made of, or faced with, wood, wood pulp,
paper, plastic or any other material that can catch re and burn is considered combustible. Even though these materials may have
been ‘ame-proofed’, made ‘re-resistant’ or are ‘re-rated’ they are considered combustible. Standard and Type X drywall are both
combustible.
NON-COMBUSTIBLE MATERIALS
A material is said to be non-combustible when it cannot catch re and burn. For example, materials made entirely, or in combinations,
of, stone, brick, concrete, tile, steel, plaster or glass are considered non-combustible.
The table below shows a list of materials which, as of this writing, are reported by their manufacturers to be non-combustible (in
accordance with the ASTM E136 standard) AND approved for use around replaces.
Skamol Skamotec® 225 and the Promat PROMAFOUR® system are preferred products for enclosing replaces.
ProductThickness
Skamol Skamotec® 225 Fireplace Building Board1½”/38 mm
Promat PROMAFOUR® System ½”/12 mm, ⁄ ”/15 mm, ¾”/18 mm
James Hardie Building Products HardieBacker® 500 ½” Cement Board ½”/12 mm
James Hardie Building Products HardieBacker® ¼” Cement Board¼”/6 mm
* The listed brand names are trademarks of their respective companies
Skamol Americas, Inc.
(844) 475-2665
E-mail: skamotec225@skamol.com
www.skamotec225.com
Promat Inc.
(865) 681- 0155
E-mail: sales@promat.us
www.promat.us/en
James Hardie Building Products
(888) 542-7343
www.jameshardie.com
Element4 Gas Fireplaces EuropeanHome.com
25
Page 26
ENCLOSING the FIREPLACE
BUILDING THE ENCLOSURE
A safe installation of your Element4 replace requires that four things be clearly understood.
1. Most important, these replaces are NOT zero-clearance replaces. Unlike zero-clearance replaces, there is not a metal box
around the Element4 replaces. With no metal box there are no louvers to distract your view of the re. However, we want the
cooling advantage of a metal box so your site-built, non-combustible enclosure will substitute.
2. Your replace enclosure must be made to act the way a metal replace box acts - letting room air in below and warm
convection air out above. The framing cannot interfere with the air ow. The Room Air Inlet is part of the replace and cannot
be changed or adjusted. The convection air outlet is part of your enclosure design, is provided by you and MUST be included.
Note! The convection air outlet must be installed in the same room as the replace or a space which ALWAYS ows air into the room
in which the replace is installed. The ow of convection air must NOT be blocked.
3. Since these are not zero-clearance replaces, the clearances and dimensions listed in the CLEARANCES section MUST be
maintained. Only the non-combustible wall, the mounting brackets and the venting may touch the replace. As previously
stated, NOTHING may be built closer than 2”/50 mm to the non-glass sides.
4. The controls will be mounted to your enclosure and below the burner. The controls are at the end of a 50”/1270mm line set
and are to be mounted to the Wall Access Door which is included. The controls must be located for ease of physical access
(gas line, maintenance, etc.) as well as wireless signal (remote control) access. See the LOCATING THE CONTROLS and the MOUNTING THE CONTROLS sections.
The combination of multiple glass sides and no zero-clearance box makes for a non-typical enclosure project. It may seem
straightforward to build the ‘rough opening’, set the replace then attach the wall. However, for most projects, it will be easier to
rst set the replace in position then enclose it with Skamol Skamotec® or Promat PROMAFOUR® building board.
REDUCED CLEARANCE TO EXISTING COMBUSTIBLE WALLS
When retrotting the replace against an existing wall it is often desirable to reduce the distance between the replace and the
combustible wall. Normally, this distance is 11”/280 mm but it may be reduced by shielding the existing nished wall with a 1” air gap
and a sheet of non-combustible material as shown.
IN ALL CASES:
• A reduced clearance shield is ONLY ALLOWED ON A VERTICAL WALL; IT IS NOT ALLOWED TO BE USED ON OTHER SURFACES WITHIN
THE NON-COMBUSTIBLE ZONE.
• The non-combustible wall shield MUST extend more than 26”/660 mm above the top of the replace. The shield shall be placed
no closer than 1”/25 mm to the oor or any intersecting walls. Air MUST be allowed to continually circulate around all sides of the
wall shield.
• A 1”/25 mm air gap between the wall shield and the existing wall MUST be maintained.
• A 2”/50 mm air gap between the wall shield and the replace MUST be maintained.
Element4 Gas Fireplaces EuropeanHome.com
26
Page 27
ENCLOSING the FIREPLACE
REDUCED CLEARANCE TO EXISTING COMBUSTIBLE WALLS
COMbUSTIbLE WALL
COMbUSTIbLE WALL
ShIELd OvER FINIShEd WALL
2”/50 mm
Minimum Air
Gap MUST BE
MAINTAINED
ShIELd OvER FINIShEd WALL
1”/25 mm Minimum Air Gap MUST BE MAINTAINED
COMbUSTIbLE WALL
ShIELd OvER FINIShEd WALL
Element4 Gas Fireplaces EuropeanHome.com
ShIELd OvER FINIShEd WALL
COMbUSTIbLE WALL
The non-combustible wall shield MUST EXTEND MORE
than 26”/660 mm above the top of the replace.
27
Page 28
ENCLOSING the FIREPLACE
MINIMUM AREA REQUIRED FOR MODORE 95 MKII
MODORE 140 MKII
FRONT STANdOFF FRAME FLUSh
When enclosing the Modore 140 MKII replace there is a minimum clear area which must be maintained. Nothing except the Modore
140 MKII may be within this area. When enclosed, the Modore 140 MKII is centered - stand o frame face in line with the front inside
or back inside blue limit and centered- above. This minimum area MUST BE DEFINED BY NON-COMBUSTIBLE MATERIAL. The inside of
the enclosing walls (including any necessary framing) may be no less than the distances shown above.
Note! The nished walls must be at least 1⁄”/28 mm thick or the replace trim will extend beyond the nished walls.
We recommend that the replace be set into its nal location before building the enclosure.
Element4 Gas Fireplaces EuropeanHome.com
28
Page 29
ENCLOSING the FIREPLACE
MINIMUM AREA REQUIRED FOR BIDORE 95 MKII
BIDORE 140 MKII
FRONT STANdOFF FRAME FLUSh
When enclosing the Bidore 140 MKII replace there is a minimum clear area which must be maintained. Nothing except the Bidore
140 MKII may be within this area. When enclosed, the Bidore 140 MKII is centered - stand o frame face in line with the front inside
or back inside blue limit and centered- above. This minimum area MUST BE DEFINED BY NON-COMBUSTIBLE MATERIAL. The inside of
the enclosing walls (including any necessary framing) may be no less than the distances shown above.
Note! The nished walls must be at least 1⁄”/28 mm thick or the replace trim will extend beyond the nished walls.
We recommend that the replace be set into its nal location before building the enclosure.
Element4 Gas Fireplaces EuropeanHome.com
29
Page 30
ENCLOSING the FIREPLACE
MINIMUM AREA REQUIRED FOR TRISORE 95 MKII
TRISORE 140 MKII
FRONT STANdOFF FRAME FLUSh
When enclosing the Trisore 140 MKII replace there is a minimum clear area which must be maintained. Nothing except the Trisore
140 MKII may be within this area. When enclosed, the Trisore 140 MKII is centered - stand o frame face in line with the front inside
or back inside blue limit and centered- above. This minimum area MUST BE DEFINED BY NON-COMBUSTIBLE MATERIAL. The inside of
the enclosing walls (including any necessary framing) may be no less than the distances shown above.
Note! The nished walls must be at least 1⁄”/28 mm thick or the replace trim will extend beyond the nished walls.
We recommend that the replace be set into its nal location before building the enclosure.
Element4 Gas Fireplaces EuropeanHome.com
30
Page 31
ENCLOSING the FIREPLACE
The nished wall(s) must be at least 1⁄”/28 mm thick or the replace trim will extend beyond the nished wall. The list below shows
the thickness of the approved wall products.
Your choice of wall material depends largely on the intended nish. For example, a thinner wall product and a layer of stone may be
thick enough to reach the trim edge. If a painted nish is desired then a wall at least 1⁄”/28 mm thick will suce.
ProductThickness
Skamol Skamotec® 225 Fireplace Building Board1½”/38 mm
Promat PROMAFOUR® System ½”/12 mm, ⁄ ”/15 mm, ¾”/18 mm
James Hardie Building Products HardieBacker® 500 ½” Cement Board ½”/12 mm
James Hardie Building Products HardieBacker® ¼” Cement Board¼”/6 mm
Fireplace Trim
Minimum Wall Thickness =
1⁄”/ 28 mm
Element4 Gas Fireplaces EuropeanHome.com
31
Page 32
ENCLOSING the FIREPLACE
Modore 140 with
Convection Outlets
Bidore 140 with
Convection Outlets
Modore 140 with
Outlet Reveal
Bidore 140 with
Outlet Reveal
Trisore 140 with
Convection Outlets
Modore 140 MKII70452
Element4 Gas Fireplaces EuropeanHome.com
Convection Air Outlet Area by Model
Model Square Inches Square Centimeters
Bidore 140 MKII70452
Trisore 140 MKII70452
32
Trisore 140 with
Outlet Reveal
Page 33
ENCLOSING the FIREPLACE
DO NOT ALLOW THE FIREPLACE
TO BEAR ANY WEIGHT
Dimension A, B, and C must be equal throughout the installation.
Any support framing (NON-combustible framing ONLY) must be at least 2”/50 mm away,
above and beside the replace. The entire weight of the non-combustible walls must be
borne by a structure other than the replace.
C
B
A
Element4 Gas Fireplaces EuropeanHome.com
33
Page 34
ENCLOSING the FIREPLACE
COLD CLIMATE INSULATION
For cold climate installations, it is especially important to insulate outside the chase cavity, between studs and under the oor on
which appliance rests, if oor is above ground level. Gas line holes and other openings should be lled with approved restop.
If the replace is being installed on a cement slab in cold climates, a sheet of plywood or a raised platform can be placed underneath
to prevent cold transferring to the replace and into the room. It also helps to tape the venting for maximum air tightness and to
caulk restops.
LOCATING THE CONTROLS
The control system for the Element4 replaces consist of three major components:
• the receiver
• the remote
• the gas valve
The remote is the remote control by which you operate the replace. The receiver and the gas control are at one end of a line set
which will extend approximately 50”/1270 mm from the center of the replace. The other end of the line set is connected to the
rebox just left of center. As shipped, the line set is wrapped together and xed beside the replace.
The Wall Access Door is provided with your replace and is designed to hold the receiver and gas control. When locating the Wall
Access Door you must consider four types of access:
1. Air access. Room air must be allowed to ow freely through the door perforations, up through the site-built platform
and above, through the enclosing replace chase.
2. Line set access. The line set is to be unwrapped which allows the controls to be then placed within approximately
50”/1270 mm from the center of the replace, as the cable runs.
3. Physical access. The gas valve/receiver must be readily accessible for maintenance, etc.
4. Wireless access. The signals from the remote must get to the receiver, inside the access door.
If the Access Door is not used its air access equivalent (25 square inches) as well as line set, physical and wireless access must be
provided.
MOUNTING THE CONTROLS
Do not place the controls above the level of the burner. If the replace is to set directly on the oor, the controls must be placed outside the
non-combustible zone or insulated from the heat from the replace.
The Wall Access Door (11¼”/286 mm high x 8⁄”/214 mm wide outer frame) requires a rough opening of 9⁄”/250 mm high x
6 ⁄ ”/175 mm wide. The door should be mounted with the hinge on the left side or with the hinge side down.
Wall Access Door Dimensions
Outer FrameRough Opening
11¼”/286 mm x 8⁄”/214 mm9⁄”/250 mm x 6⁄”/175 mm
Element4 Gas Fireplaces EuropeanHome.com
34
Page 35
ENCLOSING the FIREPLACE
Carefully cut the black tie wraps which hold
the line set to the side of the replace then
carefully unwrap the line set. Lay the line set
out towards the location of the Access Door.
Do not kink the lineset and do not bend to a
radius of less than 2”/50 mm.
Remove the four bolts holding the white door/
frame cover to the frame. Separate the frame
and cover then mount the Access Door frame
to the rough opening as shown.
Replace the white door/frame cover onto the
frame and secure it with the four bolts.
Fit the gas control tab into the bracket on
the Access Door frame.
Element4 Gas Fireplaces EuropeanHome.com
Tighten the bolt through the mounting
bosses.
35
Page 36
ENCLOSING the FIREPLACE
Set the receiver into the Wall
Access Door bracket as shown
and connect the AC adapter.
Wall Access Door
with gas control and
receiver mounted.
TEST FIRE
Prior to being placed into operation, the replace should be test-red in stages to ensure that all components are in good working
order. This replace has a 2nd thermocouple which senses the main burner ame. The system will turn itself o if the system does
not sense the 2nd thermocouple output within 20 seconds after the main valve opens.
Note that a single, long beep indicates that the 2nd thermocouple is still hot enough to produce electricity at the receiver which will
not allow the replace to start. Allow time for the 2nd thermocouple to cool down before attempting a start. The system is ready to
start when pressing the ON/OFF button produces a response from the valve.
1. Start the replace with the hearth panel out and with the front glass o. Ensure that the pilot ame both heats the primary
thermocouple and lights the main burner. For safety, a post-purge delay is built into the system. Subsequent start attempts
MUST NOT take place for at least thirty (30) seconds.
2. Start the replace with the hearth panel in place and with all of the glass panels xed correctly in place. Ensure that the
main burner ames engulf the 2nd thermocouple and the replace stays lit for at least 1 full minute. If the system turns itself
o after 20 seconds install the required media (next section) and return here. Installing the re media will help with the
ame around the 2nd thermocouple. Subsequent start attempts MUST NOT take place for at least ve (5) minutes.
3. Start the replace with the media installed. If the system turns itself o after 20 seconds, rearrange the media to produce
a good ame at the 2nd thermocouple. This step may have to be repeated several times before the media is in the best
place for consistent operation. A single, long beep indicates that the 2nd thermocouple is still too hot to start the ignition
sequence. Allow time for the 2nd thermocouple to cool down. Once the system stays lit for at least one full minute, turn
the replace o, x the glass panels in place and operate the replace for at least 45 minutes to ensure the system works
properly when heated.
Element4 Gas Fireplaces EuropeanHome.com
36
Page 37
INSTALLING THE FIRE MEDIA
LSE 418 II
LOG ARRANGEMENTS
Ensure that the hearth panels are properly placed and sitting rmly on the base of the re box. The pilot ame must be visible through
the panel and the cut-out in the pilot shield. Scatter the bag of chips evenly on the hearth panel and burners. Ensure that the area
inside the pilot shield and the area around the 2nd thermocouple remains clear of media.
What’s in the box? (LSE 418 II)
-(1) small bag of ash
-(2) bags of black/grey chips
-(2) pine cones
-(9) logs
With the chips scattered across the burner and hearth panel, lay the logs in the following sequence...
The bag of ash (shown left) comes with your log set. Its purpose is to make the logs look more
realistic. The use of this ash is optional.
To use:
- Sprinkle the ash onto the logs as desired.
- Make sure that the ash DOES NOT get inside of the burner ports. If so, clogging may occur.
Element4 Gas Fireplaces EuropeanHome.com
37
Page 38
INSTALLING THE FIRE MEDIA
STONES/GLASS ARRANGEMENTS
Ensure that the hearth panel is sitting rmly on the base of the re box and the shield is installed around the 2nd thermocouple.
The center panel must be inserted in between the burner tubes. The pilot ame must be visible through the hearth panel and the
pilot shield.
Evenly scatter the contents of the bag of stones/glass over the top of the hearth panel and burner. Ensure that none of the stones/
glass enters the pilot area or restricts the operation of the 2nd thermocouple.
The arrangement is now complete. However, it is important to check that the pilot ame is still visible.
A shows the arrangement for stones; the arrangement for glass is similar.
A
2nd Thermocouple
(actual burner pilot assembly and thermocouple location may vary depending on model)
(grey stones shown here)
B shows the pilot area (below) clear of media (above).
C shows the 2nd thermocouple area (below) clear of media (above).
B
Pilot Assembly
Pilot Area
C
2nd Thermocouple
To see how to arrange media in an Element4 replace
WWW.EUROPEANHOME.COM/RESOURCES/VIDEOS/
Element4 Gas FireplacesEuropeanHome.com
please visit the link below.
38
Page 39
SCREEN INSTALLATION
MODORE 140 MKII
Upper Tabs2
Lo wer Tabs2
Magnets6
Long Screen1
Short ScreenN/A
against
the glass
BIDORE 140 MKII
Upper Tabs3
Lo wer Tabs3
Magnets9
Long Screen1
Short Screen1
Lower TabShort side
Tall side
against
the screen
Top half
mounts to
backside of
stando frame
(top)
TRISORE 140 MKII
Upper Tabs4
Lo wer Tabs4
Magnets12
Long Screen1
Short Screen2
Up per Tab
Top half
mouints to
backside of
screen frame
(top)
Short Screen
Element4 Gas Fireplaces EuropeanHome.com
Long Screen
Place the (2) Lower Tabs on the trim, with the
short side against the glass, ~2-3” from each
corner of the glass. Place a magnet on the front
of each tab.
39
Page 40
SCREEN INSTALLATION
Place the (2) Upper Tabs on the inside of the top
stand o frame. One magnet will be hidden,
attached to the standoff frame. The other
magnet will be exposed to attach to the screen.
Element4 Gas Fireplaces EuropeanHome.com
This is what the screen will look like when it is
attached correctly to the top Upper Tabs (view
from inside of the stando frame).
40
Page 41
SCREEN INSTALLATION
This is what the screen will look like when it is
attached correctly to the top Lower Tabs (view
between the screen and the glass).
Element4 Gas Fireplaces EuropeanHome.com
The screen is installed properly in the photo
above. Please make sure that all magnets are in
the correct position and the tabs are secured.
41
Page 42
OPERATING the FIREPLACE
BEFORE THE FIRST FIRE
1. Make certain that all construction materials have been removed from inside and around the replace and the replace has
been cleaned of any construction dust. Clean the glass BEFORE and AFTER the rst re.
2. Conrm that the gas valve is properly connected and bled by a certied gas technician or plumber.
3. Check the gas supply for leaks and proper pressure. --- Refer to the table in “Appliance Ratings” section.
4. Check that the venting is unobstructed and in proper working condition.
5. PROPERLY PLACE, CLAMP, AND SEAL THE GLASS PANELS.
6. Ensure the receiver is plugged in with AC Adapter OR Batteries... NOT BOTH.
7. Place the three AAA batteries into the remote control and conrm that it will communicate with the receiver by pressing
the ON/OFF button. If necessary pair the remote and receiver.
8. Follow USING THE REMOTE CONTROL ELECTRONIC IGNITION SEQUENCE to setup and use remote.
PAIRING THE REMOTE AND RECEIVER (System Reset)
From the factory, the remote control will communicate with the receiver; they are ‘paired’ and should need no further attention. If
the receiver does not respond to commands from the remote they should be paired to each other. This is done as follows:
1. Press and hold the receiver reset button using a small, long tool until you hear the second of two beeps. After the second
beep release the reset button.
2. Press and hold the button on the remote until you hear the second of two beeps. Release the button.
If you hear one long beep, this indicates the pairing sequence has failed or the wiring is incorrect.
RESET BUTTON
MANUAL KNOB IN
ON POSITION
Note! For normal operation the MANUAL knob on the gas valve cannot be in the MAN position; it must be fully in the ON position.
MAIN VALVE KNOB
IN ON POSITION
(This knob is AUTOMATIC and will
turn o when the replace is turned
o & on when the replace is turned
on.)
Element4 Gas Fireplaces EuropeanHome.com
42
Page 43
OPERATING the FIREPLACE
NOTICE
WARNING
Countdown Timer
Program Mode
Display
SETTING FAHRENHEIT or CELSIUS
To change between °C and °F, press and
AM
PM
ON
OFF
1 2
buttons simultaneously.
NOTE: Choosing °F results in a 12 hour clock.
Choosing °C results in a 24 hour clock.
1 2
ON
OFF
Time
Temperature
Signal Indicator Child Proof
AM
PM
CHILD PROOF
ON
OFF
1 2
Thermostatic Mode
Auxiliary Feature
ON:
AM
PM
To activate, press and buttons
simultaneously displayed and the
remote is rendered inoperable, except for
the o function.
Battery Status
Fahrenheit or Celsius
Eco Mode
SETTING the TIME
1. Press and buttons simultaneously.
Day ashes.
AM
PM
ON
OFF
1 2
2. Press or button to select a number
to correspond with the day of the week
(e. g. = Monday, = Tuesday, = Wednesday, = Thursday, = Friday, = Saturday, = Sunday).
3. Press and buttons simultaneously.
Hour ashes.
4. To select hour press or button.
5. Press and buttons simultaneously.
Minutes ash.
6. To select minutes press or button.
7. To conrm press and buttons
simultaneously or wait.
OFF:
To deactivate press and buttons
simultaneously. disappears.
MANUAL MODE REMOTE
BEFORE OPERATING
1. Make sure MANUAL knob on the valve is in the ON, full counterclockwise
position.
2. Place the ON/OFF switch (if equipped) in the I (ON) position.
TO TURN ON FIRE
TO TURN ON FIRE
***PLEASE SEE NEXT PAGE FOR FURTHER INSTRUCTIONS***
When pilot ignition is conrmed, motor turns automatically to
maximum ame height.
Element4 Gas Fireplaces EuropeanHome.com
43
Page 44
OPERATING the FIREPLACE
NOTICE
NOTICE
WARNING
WARNING
Remote One-Button Operation
AM
PM
ON
OFF
1 2
(Default Setting)
• Press and hold button until two short
beeps and a blinking series of lines
conrms the start sequence has begun;
release button.
• Main gas ows once pilot ignition is
conrmed.
• Remote automatically goes into Manual
Mode after main burner ignition.
Change from one-button to two-button ignition operation by
pressing and holding
talling batteries.
complete
will change to .
button for 10 sec. immediately after ins-
is displayed and is ashing. When change is
Remote Two-Button Operation
AM
PM
ON
OFF
1 2
• Press and button simultaneously
until two short beeps and a blinking series
of lines conrms the start sequence has
begun; release buttons.
• Main gas ows once pilot ignition is
conrmed.
• Remote automatically goes into Manual
Mode after main burner ignition.
Change from two-button to one-button ignition operation by
pressing and holding
talling batteries.
complete
will change to .
button for 10 sec. immediately after ins-
is displayed and is ashing. When change is
FLAME HEIGHT ADJUSTMENT
FLAME HEIGHT ADJUSTMENT
AM
PM
ON
OFF
1 2
Remote
• To increase ame height press and hold
button.
• To decrease ame height or to set appliance
to pilot ame, press and hold button.
DESIGNATED LOW FIRE and HIGH FIRE
NOTE: Backlight must be on for high re and low re double-click
operation.
• To go to low re, double-click button.
AM
is displayed.
NOTE: Flame goes to high re rst before
going to low re.
• To go to high re, double-click button.
AM
is displayed.
If the pilot does not stay lit after several tries, turn the main valve
knob to OFF and follow the operating instructions “TURN OFF GAS
TO APPLIANCE”.
STANDBY MODE PILOT FLAME
STANDBY MODE PILOT FLAME
Remote
•
Press and hold
button
to set appliance to pilot ame.
TO TURN OFF FIRE
Remote
• Press
AM
PM
ON
OFF
1 2
Element4 Gas Fireplaces EuropeanHome.com
NOTE: There is a 5 second delay before the
button to turn OFF
next ignition is possible.
If the appliance will not operate, follow the instructions “TURN OFF
GAS TO APPLIANCE”.
COUNTDOWN TIMER
ON/SETTING:
AM
PM
ON
OFF
1 2
.
1. Press and hold button until displayed,
and hour ashes.
2. To select hour press or button.
3. To conrm press button. Minutes
ash.
4. To select minutes press or button.
5. To conrm press button or wait.
OFF:
Press button,
and countdown time disappear.
NOTE: At end of countdown time period, the re turns o. The
Countdown Timer only works in Manual, Thermostatic, and
Eco Modes. Maximum countdown time is 9 hours and 50
44
minutes.
Page 45
OPERATING the FIREPLACE
MODES of OPERATION
AM
PM
ON
OFF
1 2
AM
PM
ON
OFF
1 2
AM
THERMOSTATIC MODE
AM
PM
ON
OFF
1 2
AM
PM
ON
OFF
1 2
Thermostatic Mode
The room temperature is measured and
compared to the set temperature. The ame
height is then automatically adjusted to
achieve the set temperature.
Program Mode
PROGRAMS 1 and 2, each can be
programmed to go on and o at specic
times at a set temperature.
Eco Mode
Flame height modulates between high and
low. If the room temperature is lower than
the set temperature, the ame height stays
on high for a longer period of time. If the
room temperature is higher than the set
temperature, the ame height stays on low
for a longer period of time. One cycle lasts
approximately 20 minutes.
ON:
Press button. displayed, preset
temperature displayed briey, and then room
temperature displayed.
OFF:
1. Press button.
2. Press or button to enter Manual
Mode.
3. Press button to enter Program Mode.
4. Press button to enter Eco Mode.
SETTING:
1. Press button and hold until
displayed, temperature ashes.
2. To adjust set temperature press or
button.
3. To conrm press button or wait.
PROGRAM MODE
ON:
AM
PM
ON
OFF
1 2
Press button. , or , or
displayed.
OFF:
1. Press or or button to enter
AM
PM
ON
OFF
1 2
Manual Mode.
2. Press button to enter Thermostatic
Mode.
NOTE: The set temperature for Thermost atic Mode is the temperature
for the on time in Program Mode. Changing the Thermostatic
Mode set temperature also changes the on time temperature
in Program Mode.
Default settings:
ON TIME (Thermostatic) TEMPERATURE: 21 °C (70 °F)
OFF TIME TEMPERATURE: “” (pilot ame only)
TEMPERATURE SETTING:
1. Press button and hold until
AM
PM
ON
OFF
1 2
ashes. and set temperature (setting
in Thermostatic Mode) displayed.
2. To continue press button or wait. ,
displayed, temperature ashes.
3. Select o temperature by pressing the
or button.
4. To conrm press button.
NOTE: The on (Thermostatic) and o set temperatures are the same
for each day.
DAY SETTING:
AM
PM
ON
OFF
1 2
5. ashes. Press or button to
choose between , , , , , , , , .
6. To conrm press button.
Element4 Gas Fireplaces EuropeanHome.com
45
Page 46
OPERATING the FIREPLACE
WARNING
NOTICE
GENERAL NOTES
Wiring of valve and receiver must be completed before starting
ignition. Failure to do so could damage the electronics.
Batteries – Remote
• Low battery indicator on remotes.
Batteries – Receiver
• Low battery indication: frequent beeps for 3 seconds when motor
turns.
• Instead of batteries, the included AC adapter should be used for
improved reliability and customer satisfaction.
• While not using an AC adapter, battery replacement is
recommended at the beginning of each heating season.
• Old or dead batteries should be removed immediately. If left in the
unit the batteries can overheat, leak, and/or explode.
• Do NOT expose batteries (including during storage) to direct
sunlight, excessive heat, re, moisture, or severe impact. Each of
these conditions can cause the batteries to overheat, leak, and/or
explode.
• New and old batteries and dierent brands of batteries should
not be used together. Mixing of various batteries can cause the
batteries to overheat, leak, and/or explode.
The following Functions can be Deactivated/Activated
• CHILD PROOF (To activate press and buttons simultaneously.
displayed and the remote is rendered inoperable (except for
o function).
• PROGRAM MODE
• THERMOSTATIC MODE (also deactivates Program Mode)
• ECO MODE
• LIGHT/DIMMER OPERATION
• CIRCULATING FAN OPERATION
• AUXILIARY FEATURE
• COUNTDOWN TIMER
Automatic Turndown.
1. In Manual/Temperature/Timer modes, the valve will turn to pilot
ame if there is no change in ame height for a six hour period.
In Temperature or Timer mode, if the ambient room temperature
changes, the ame height will adjust automatically to maintain set
temperature and the re will continue to function normally. The
valve will turn to pilot ame if the set temperature and the ambient
room temperature remain the same over a six hour period.
2. The valve turns to pilot ame if the temperature in the receiver is
higher than 140°F/60°C. The burners comes back on only when the
temperature is below 140° F/60°C.
Software Version
Press and buttons simultaneously. Software version is displayed.
Remote Model Number
Press and buttons simultaneously. Remote model number is
displayed.
Deactivate Functions
1. Install batteries. All icons are displayed and ashing.
2. While the icons are ashing, press the relevant function button and
hold for 10 sec.
3. The function icon will ash until deactivation is complete.
Deactivation is complete when the function icon and two
horizontal bars are displayed.
NOTE: If a deactivated button is pressed, there is no function, and
two horizontal bars are displayed.
NOTE: Deactivation remains in eect after change of batteries.
Activate Functions
1. Install batteries. All icons are displayed and ashing.
2. To activate a function, press the relevant button and hold for
10sec.
3. The function icon will continue to ash until activation is complete.
Activation is complete when the function icon is displayed.
Automatic Shut O.
1. With low battery power in the receiver, the system shuts o
the re completely. This does not happen if the power supply is
interrupted.
2. The system shuts o the re completely if there is no change in
ame height for 5 days.
3. The system shuts o the re if the main burner does not
completely ignite approximately 20 seconds after ignition or after
pushing the button.
Element4 Gas Fireplaces EuropeanHome.com
46
Page 47
OPERATING the FIREPLACE
THE FIRST FIRE
When the replace is rst heated, an odor may be given o by the hot metal. This is normal and is a result of the ‘burn o’ of the
lubricants and sealants used when manufacturing the replace. We recommend that you open the nearby windows for extra
ventilation and then operate the replace for at least four hours.
When the glass is cold, some condensation may appear on the glass after lighting the replace. This is normal and the
condensation will disappear as the glass warms.
During this rst re, examine the ame for appearance and quality. Examine the burner media for sooting. The ames should look
like those shown below.
After this burn-o period, turn o the replace and let it cool completely to room temperature and clean both sides of the glass
and the interior panels as described in the MAINTENANCE section.
Since it is a metal replace, the heat-up and cool-down cycles may produce some noises caused by the expansion and contraction
of these metals. The premium materials and build quality of your replace will keep these sounds to a minimum.
To see an Element4 replace starting and running normally
WWW.EUROPEANHOME.COM/RESOURCES/VIDEOS/
Element4 Gas Fireplaces EuropeanHome.com
please visit the link below.
47
Page 48
MAINTENANCE
REMOVING AND CLEANING THE GLASS
OVERVIEW
The glass panels on this replace are held in place by a number
of rope gaskets. These instructions will show you how to remove
and install the rope gaskets and glass panels.
Please read these instructions completely before proceeding.
TOOLS REQUIRED
• Gloves (not included)
REMOVING THE GLASS
Step 1.
Remove the lower and upright trim pieces which are held in
place with magnets and will lift out.
Step 2.
The front glass panel should be removed rst. This panel is
secured with one lower rope gasket and one upper rope gasket.
Remove the SIDE TRIM rst,
then the BOTTOM TRIM
Step 3.
Once the rope gaskets are out, lift the glass panel up and swing
the lower edge of the glass panel out and over the stando
frame.
When the glass panel is clear of the stando frame then lower
the glass panel out and set the panel securely aside.
Step 4.
Remove all of the rope gaskets holding each remaining glass
panel (if applicable). Remove each small glass panel and set
aside.
PROPERLY PLACE ROPE GASKET(S) AND SEAL THE GLASS
PANEL(S) BEFORE LIGHTING THE FIRE!
Remove the ROPE GASKET
starting from one end down
to the other end
The ROPE GASKET will be
removed for all remaining
sides (if applicable)
Element4 Gas Fireplaces EuropeanHome.com
48
Page 49
MAINTENANCE
CLEANING THE GLASS
Burning natural gas (NG) or propane (LP) in this replace will always result in some of the gas components being deposited on the
glass. Hydrogen suldes and mercaptans, which are present in the burning gas, condense onto the relatively cooler glass surface
and cause white lm to build up over time.
The amount of this white lm is inuenced by a number of factors such as; the conguration of the system venting, thermal eciency
of the replace design, the humidity of combustion air, frequency of replace use, burner performance and, the replace design itself.
Do not use normal household (usually ammonia-based) glass cleaners to clean the glass as these cleaners can leave a permanent
stain. Only a gas replace glass cleaner should be used. Products such as Stove Bright® Gas Appliance Glass Cleaner by Forrest
Technical Coatings, Imperial Gas Fireplace Glass Cleaner by Imperial Manufacturing Group and GFC™ Gas Fireplace Glass Cleaner by
A.W. Perkins Co. are designed for this purpose.
Follow the instructions for use and do not clean the glass when it is hot! If the glass becomes coated with deposits which cannot
be removed it must be replaced.
The replace glass should be cleaned before the replace is rst lit and then after the replace has been through its four hour burnin cycle. This will reduce potential build up on your glass.
INSTALLING THE GLASS
The glass panels should be installed in reverse order of their removal.
Step 1.
Lift the glass panel up under the stando frame and swing the lower edge of the glass panel against the rebox gasket. Set a rope
gasket into place and secure it from the middle to the left and right sides.
Step 2.
Repeat Step 1 with the remaining glass panels.
Step 3.
Adjust the remaining glass panels left to right until there is no corner gap.
Step 4.
While ensuring that the glass panels are tight and square to each another, carefully install the remaining rope gaskets.
PROPERLY PLACE ROPE GASKET(S) AND SEAL THE GLASS PANEL(S) BEFORE LIGHTING THE FIRE!
Element4 Gas Fireplaces EuropeanHome.com
49
Page 50
MAINTENANCE
Pilot Injector Natural - Marking 31.2
Pilot Injector Propane - Marking 27.1
3mm
WARNING
Installation and maintenance must be performed by an authorized qualied installer, service agency or gas supplier.
TURN OFF THE GAS before servicing the appliance. It is recommended that a qualied service technician perform an
appliance check-up/service once a year.
Any safety screen or guard removed for servicing MUST BE REPLACED before operating this appliance.
DO NOT USE this appliance if any part has been under water. Immediately call a qualied service technician to inspect the
unit and to replace any part of the control system and any gas valve that has been under water.
Any alteration to the product that causes soot or carbon to form and results in damage is not the responsibility of the
manufacturer.
Inspect the external vent cap on a regular basis to make sure that no debris, plants, trees, or shrubs are interfering with the
air ow.
BURNER MAINTENANCE
The ames from the burner should be visually checked. The ame should have a blue base and yellow tops and be candle-like in
appearance.
PILOT MAINTENANCE
The pilot ame must be visually checked. The pilot ame must always be present when the appliance is in operation and should
appear as shown (with hearth panel removed.)
The pilot has two distinct ames, one engulng the thermocouple on it’s left, the other reaching across to the main burner.
The area around the pilot should be inspected for cleanliness. Lint or foreign material must be removed with a brush or vacuum.
Thermocouple
Ignitor Rod
Pilot Assembly
Element4 Gas Fireplaces EuropeanHome.com
Thermocouple
Ignitor Rod
(styles vary)
Pilot Assembly Detail
50
Page 51
MAINTENANCE
Natural Gas Injector - marked 1200Propane Gas Injector - marked 320
THERMOCOUPLE MAINTENANCE
The Element4 replaces have two thermocouples; one next to
the pilot and one opposite the pilot side of the main burner. The
completeness and operation of both must be checked. A qualied
installer must conrm that both thermocouples are in place and
not damaged. While checking the thermocouple, please ensure
that the ignitor rod is not cracked as well.
VENT MAINTENANCE
The following venting system inspection by a qualied service
technician is recommended every six months:
1. Inspect for excessive condensation, e.g. water droplets
forming in the inner lining and subsequently dripping out of
the joints. This can cause corrosion in the system.
2. Check for corrosion in areas exposed to the elements.
Where rust spots or holes have appeared, these must be
immediately replaced.
3. Ensure that there is no foreign material in the vents. Survey
by removing the cap and shining a light down the vent.
4. Check all joints and pipes to make sure that nothing has
been disturbed or loosened.
REPLACEMENT PARTS
The orice for the burners is shown below. The NG orices are marked 650, LP orices are marked 220.
European Home warrants these gas fireplaces against defects in materials and workmanship for a period of ONE (1) YEAR
from the date of original retail purchase. Glass is expressly NOT covered by this warranty.
If a defect exists, European Home will, at its option, either (1) provide needed components using new or refurbished
replacement parts or (2) exchange the product with one which is new or which has been manufactured from new or
serviceable used parts and is at least functionally equivalent to the original product. A replacement product/part assumes
the remaining warranty of the original product or ninety (90) days from the date of replacement or repair, whichever
provides longer coverage for you. When a product or part is exchanged, any replacement item becomes your property and
the replaced item becomes the property of European Home. All warranty claims must be submitted through the dealer
from which you purchased the product. Check with your dealer in advance for any costs to you when arranging a warranty
call. Shipping and/or delivery charges for parts are not covered by this warranty.
Nothing in the above shall be deemed to imply that this warranty shall apply to work which has been abused or neglected
or shows evidence of changes or modifications by others with or without permit, damages caused by the acts of God,
building settlement or moving, fire or vandalism. In addition, installation of this product that varies from the requirements
stated in the instruction manual will void the warranty.
PRODUCT INSTALLATION RECORD
Installer: Please complete this form. Customer: Please retain this information.
This appliance is approved for installation in the Commonwealth of Massachusetts. The Board of State Examiners of Plumbers and
Gas Fitters has issued approval number G1-0515-495 for this appliance.
The following must be observed when installing the Element4 replaces within the Commonwealth of Massachusetts:
(a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole
or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust
vent termination is less than seven (7) feet above nished grade in the area of the venting, including but not limited to decks and
porches, the following requirements shall be satised:
1. INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas
fueled equipment, the installing plumber or gastter shall observe that a hard wired carbon monoxide detector with an alarm
and battery back-up is installed on the oor level where the gas equipment is to be installed. In addition, the installing plumber
or gastter shall observe that a battery operated or hard wired carbon monoxide detector with an alarm is installed on each
additional level of the dwelling, building or structure served by the side wall horizontal vented gas fueled equipment. It shall be
the responsibility of the property owner to secure the services of qualied licensed professionals for the installation of hard wired
carbon monoxide detectors
a. In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic,
the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent oor
level.
b. In the event that the requirements of this subdivision can not be met at the time of completion of installation, the
owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that during said
thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be installed.
2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above
provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certied.
3. SIGNAGE. A metal or plastic identication plate shall be permanently mounted to the exterior of the building at a
minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled
heating appliance or equipment. The sign shall read, in print size no less than one-half (½) inch in size, "GAS VENT DIRECTLY
BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS".
4. INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve
the installation unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance
with the provisions of 248 CMR 5.08(2)(a)1 through 4.
(b) EXEMPTIONS: The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4:
1. The equipment listed in Chapter 10 entitled "Equipment Not Required To Be Vented" in the most current edition of
NFPA 54 as adopted by the Board; and
2. Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from
the dwelling, building or structure used in whole or in part for residential purposes.
(c) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM PROVIDED. When the manufacturer of Product
Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the
equipment, the instructions provided by the manufacturer for installation of the equipment and the venting system shall include:
1. Detailed instructions for the installation of the venting system design or the venting system components; and
2. A complete parts list for the venting system design or venting system.
(d) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of a
Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the ue gases, but
identies "special venting systems", the following requirements shall be satised by the manufacturer:
1. The referenced "special venting system" instructions shall be included with the appliance or equipment installation
instructions; and
2. The "special venting systems" shall be Product Approved by the Board, and the instructions for that system shall
include a parts list and detailed installation instructions.
(e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all
venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or
equipment at the completion of the installation.
Element4 Gas Fireplaces EuropeanHome.com
53
Page 54
APPENDIX TWO
TROUBLESHOOTING FLOW CHART
FUNCTIONPOSSIBLE CAUSEREMEDY
A.
Press UP and OFF
buttons to start igni-
tion sequence. Beep
will occur each
second.
Yes
(continued)
No
Remote batteries low.
Receiver batteries low.
Check that remote and receiver are
synchronized.
Remote distance is limited.
Defective AC adapterReplace the AC adapter.
Damaged wiringInspect/test all wiring and connections.
Test the batteries. replace if necessary.
Quality 1.5V AA alkaline recommended.
Note: Do NOT connect an AC adapter when
using receiver batteries.
Reset system, see the installation manual
or the label on the receiver.
One long beep indicates the wiring is
incorrect or the code learning sequence
has failed.
Straighten the antenna.
Replace the receiver.
Wait for 2nd thermocouple to cool down
(3-5 minutes)
Element4 Gas Fireplaces EuropeanHome.com
54
Page 55
APPENDIX TWO
FUNCTIONPOSSIBLE CAUSEREMEDY
B.
Magnet unit is
energized thus pro-
ducing an obvious
latching sound.
Yes
No
No
No
No beep
3 short beeps
1 long beep
Impulse magnet not
operating properly.
Receiver batteries low.
8-wire cable is o or
not operating
properly.
SW-cable
disconnected.
Motor not operating
properly.
Micro switch not
operating properly.
ON/OFF switch is in
the OFF (O) position.
2nd thermocouple
not connected
Replace gas valve.
Test the batteries, replace if necessary.
Quality 1.5V AA alkaline recommended.
Conrm proper operation of the 8-wire
cable.
Conrm proper connection/operation of
the SW-cable.
Replace gas valve.
Replace gas valve.
If equipped, set switch to ON ( | ) position.
Conrm integrity of 2nd thermocouple and
connection.
C.
Spark will occur
each second.
Yes
(continued)
No
No
No
No
Check connection between ignition cable and ignition
electrode.
Ignition components not
operating properly.
Ignition sequence stops after one spark
Ignition sequence stops, no pilot flame.
No reaction to remote command.
Ignition sequence stops, no pilot flame.
Remote command is possible.
Check ignition electrode spark gap.
Check ignition electrode.
Check ignition cable for damage.
Increase distance between ignition cable and all metal
parts.
Remove ground bolt (T20 Torx, above) and
clean ground lug.
Reset system, see the installation manual or
the label on the receiver.
Do not coil the ignition cable.
Shorten the ignition cable, if possible.
Test the batteries, replace if necessary.
Quality 1.5V AA alkaline recommended.
Element4 Gas Fireplaces EuropeanHome.com
55
Page 56
APPENDIX TWO
FUNCTIONPOSSIBLE CAUSEREMEDY
D.
Pilot lit.
Yes
E.
Sparking stops after
pilot is lit.
Yes
No
No
No
Magnet
unit
drops
(audible
sound)
TC- and SW-cable reversed.
Magnet unit not operating properly.Replace gas valve.
Short between interrupter and SW cable.Check interrupter block connection.
No gas (magnet unit drops after 30 second
audible count.)
Spark not lighting the pilot.Check spark is crossing pilot orice.
Short between interrupter block and TCcable.
Electronic measuring amplier defective.Replace the receiver.
Resistance in thermocouple circuit too
high.
Not enough heat on thermocouple.
Check cable connection between receiver
and interrupter block.
Check gas supply.
Check connection to interrupter block.
Check thermocouple circuit.
Check position of pilot to thermocouple.
Check the stability and intensity of pilot ame.
Ensure the proper restrictor is installed.
Ensure that the pilot ame is properly
adjusted.
Possible cold start
Replace thermocouple. Do not over tighten hand tight plus ¼ turn maximum.
Reset system, see the installation manual or
the label on the receiver.
Do not coil the ignition cable.
Remove hearth panel and glass and check
for proper pilot operation. If pilot establishes
with panel o then install panel and glass
and adjust pilot ame (hi/lo) for best
operation.
F.
Motor turns to main
gas and pilot stays
lit.
No
No
Low voltage from thermocouple.
No gas (magnet unit drops after 30
second audible count.)
Broken receiver
Ignition sequence stops.
No reaction to remote command.
Element4 ‘140’ models ONLY: Pilot ame
under hearth panel not establishing.
Yes
(continued)
Element4 Gas Fireplaces EuropeanHome.com
56
Page 57
APPENDIX TWO
FUNCTIONPOSSIBLE CAUSEREMEDY
G.
Main burner is lit.
Yes
No
No
No
Manual knob is in the “MAN” position.
Pilot ame is too low.
System
‘drops out’
- all ames
immediately
go out
Main burner
remains lit
while ames
are lowered.
Too much draft at
pilot ame (poor
ame impingement
of primary
thermocouple.)
Pilot assembly out of
order.
5 day shut o.
2nd thermocouple is
not heated.
Turn the control knob to “ON” position, a
positive latch is required.
Conrm correct gas pressure. Increase pilot
ame if necessary.
Check venting installation. Use
restrictor as required.
Inspect pilot assembly for correct
operation and thermocouple
impingement.
The system shuts o the re and pilot if
there is no change in the ame height
for 5 days.
Ensure 2nd thermocouple is heated by a
robust ame. The replace media may
be interfering with proper ame. Check
2nd thermocouple wiring.
H.
Main burner stays
lit.
Yes
(continued)
No
(Main valve
knob is
turned via
motor.)
System goes
to pilot ame
only.
2nd thermocouple shut
o.
6 hours of no motor
movement.
The system shuts o the re when the
main burner ame is not sensed within
22 seconds of ignition or not sensed
after pressing the large ame button.
Note: If the system fails to light due
to the 2nd thermocouple voltage not
being sensed a two minute lockout
period begins. This lockout time allows
the gas to dissipate.
In Manual/Temperature/Timer modes
the valve turns down to pilot only if the
ame height does not change for a 6
hour period.
In Temperature/Timer modes if
the ambient room temperature
changes, the ame height will adjust
automatically to maintain the set
temperature and the re will continue
to function normally. The valve will turn
to pilot ame if the set temperature
and the ambient temperature remain
the same over a 6 hour period.
Element4 Gas Fireplaces EuropeanHome.com
57
Page 58
APPENDIX TWO
OPERATION
FUNCTIONPOSSIBLE CAUSEREMEDY
I.
Magnet unit drops
while motor turns.
Receiver makes 3
beeps.
No
J.
Flames become
thin, blue, wispy
then go out.
No
K.
Flames are very
yellow with dark,
sooty tips.
Yes
Yes
Yes
Receiver batteries low.
Ensure magnet unit is operating
normally.
Exhaust is contaminating the fresh air.
Flow of fresh air and/or exhaust is
blocked.
LP gas being used with NG orice(s).
The air shutter is closed when using
LP gas.
Flow of fresh air and/or exhaust is
blocked.
Test the batteries, replace if necessary.
Quality 1.5V AA alkaline recommended.
Test the receiver output to the magnet unit.
Inspect venting for damage and/or incorrect
installation.
Ensure that vent conguration is within the
vent chart requirements.
Check termination for blockage and/or
appropriate type.
Ensure the gas type is correct for the
installed orices.
When using LP gas the air shutter must be fully
open. See conversion instructions.
Ensure that vent conguration is within the
vent chart requirements.
Check termination for blockage and/or
appropriate type.
No
L.
Flames are very
busy and blowing in
an abnormal direc-
tion.
No
M.
Flames are stable
but too small and
blue.
No
NORMAL
Yes
Yes
Air leak in the rebox.
Too much primary air.
Check unit for leaks at glass corners or at
gaskets.
Check unit for positive relief door seal.
Check venting for complete integrity.
Reduce the primary air opening until ames have blue
base and yellow upper two-thirds.
The E4-SA-LPCK-140MKII-01 LP conversion kit contains these
instructions plus the following:
• one Pilot Orice (stamped 27)
• two Main Burner Orices (stamped 220)
Converting your replace to LP gas requires the following:
- a 7 mm box/open end wrench
- a 10 mm box/open end wrench
- a 13 mm box/open end wrench
- a 17 mm box/open end wrench
- a No. 2 Phillips screwdriver
- a pair of small needle nose pliers
- a bright work light
APPLICABLE MODELS
CONTENTS
TOOLS REQUIRED
• Loosen the two shutter bolts (7 mm) holding each of the two
shutters in place, remove the shutters and tighten the bolts.
• Remove the compression nuts (17 mm) from each of the
orices and, taking care to not deform the supply tube, slide
the supply tube out of the orice.
• Loosen the orice locknut (13 mm) and unscrew the NG
burner orice from each of the burners
• Screw an LP orice into each burner until the orice is
aligned with the supply tube.
• Connect the supply tube to each of the burner orices and
tighten the compression nuts.
• Tighten the orice locknuts.
• Remove the pilot burner inlet tube (10 mm) from the pilot
burner. See below.
CAUTION: The next step involves small parts which can be
easily lost.
Note: The pilot inlet nut is easily reached at the bottom of
the replace when the replace is tilted slightly rearward.
Take care to stabilize the replace!
WARNING!
This conversion must be done by a licensed
plumber or gastter.
Turn o the gas supply before proceeding.
Begin by reading all instructions thoroughly.
INSTALLATION
These models have a double burner and, therefore, two main
burner orices must be replaced.
• Remove a long glass panel and carefully store it.
• Remove all of the re media.
• Remove the six hearth (bottom) panels by removing the ten
retaining bolts then lifting up each of the six panels.
• Remove the six bolts attaching the burner base to
the rebox.
• Using a 10mm wrench, loosen the pilot inlet nut and remove
the pilot burner inlet tube from the pilot burner. The pilot
orice then drops out of the pilot burner. See below.
Pilot Burner
Pilot Orice
Pilot Inlet Nut
Pilot Inlet Tube
Element4 Gas Fireplaces EuropeanHome.com
59
Page 60
APPENDIX THREE
Orices and Shutters
Supply Tube
Compression Nut
Shutter
Shutter Bolts
Burner Orice
• On the gas valve, between the Manual Knob and the Main Valve
Knob is a black plastic cap which hides access to the pressure
regulator adjustment screw. Remove black plastic cap to gain
access to the pressure regulator adjustment screw. See right.
• Connect LP gas supply to replace. Loosen the screw inside
the manifold pressure test port and connect the manometer to
the port. See photo, right.
• Turn on the replace and set the ames to high. While turning
the pressure regulator screw, adjust the manifold pressure to
that stated in the installation manual.
• Turn o the replace, remove the manometer and close the
test port screw.
• Replace the hearth panels, the burner media and the glass
panel. Check for proper replace operation.
Pressure Regulator
Adjustment Screw
(cap removed)
• Remove the pilot burner orice and replace it with the LP
orice (stamped 27) provided. Take care to observe the proper
orientation, shown.
• Connect the pilot burner inlet tube and tighten the inlet nut.
To see how to convert the gas on an Element4 replace,
Element4 Gas Fireplaces EuropeanHome.com
Orice Locknut
Manifold Pressure
Test Port
please visit the link below.
60
Page 61
APPENDIX FOUR
INSTALLING AN OPTIONAL WALL SWITCH
see Figure 5.1
1. Install a single-gang electrical workbox (not supplied) at the
desired location - no more than 26 feet as the cable runs.
2. While keeping the black connector (A) inside the work box,
thread the black 4-wire cable through the workbox and bring
the red connector (B) to the location of the receiver.
3. Connect the black connector (A) to the wall switch, the red
connector (C) to the receiver.
4. Test for proper operation then screw the wall switchplate to
the workbox with the two screws provided and attach the
faceplate (included).
B
A
Figure 5.1
USING THE WALL SWITCH
see Figure 5.2
Note that, with the wall switch, you can turn the replace on and o and adjust the ames up
and down. The rear burner, however, can only be turned on/o with the remote control (model
applicable).
• Turn replace ON: Press the ON/OFF button until a short beep conrms the start sequence
has begun then release the button.
• Increase the ame height: Press and hold the UP button.
• Decrease the ame height: Press and hold the DOWN button.
• For ne adjustment tap the UP or DOWN button as necessary.
• Turn replace OFF: Press the ON/OFF button.
UP
ON/OFF
DOWN
Figure 5.2
Element4 Gas Fireplaces EuropeanHome.com
61
Page 62
APPENDIX FIVE
CONNECTING TO A SMART HOME SYSTEM
GENERAL NOTES
The replace may be operated through an external source such as a smart home (home automation) system by using the 5-pin
connector on the receiver.
A required 39”/1000 mm cable, with connector, is available (part number E4-SA-SHSC-02). The overall cable length should not
exceed 26’/8000 mm.
Signal relays (gold contacts) or opto-couplers are recommended but not supplied. The E4-SA-SHSC-02 cable must be connected
to the three smart home system contacts as shown below.
WARNING
You MUST ensure that the replace is in a safe and ready condition before attempting to operate from a remote source.
SEqUENCEOFOPERATION
• To start ignition, close contacts 1 and 3 simultaneously
for 1 second.
• To set the valve to High Fire, close contact 1.
To set the valve to Pilot, close contact 3. In each case, the
contacts need to be closed for 12 seconds to turn the
motor from one end-stop to the other end stop.
• To set the valve to the O position, close contacts 1, 2,
and 3 simultaneously for 1 second.
E4-SA-SHSC-02
MOdESOFOPERATION
• Mode 1 - the external source provides “ON“ and “OFF“
operation only. The remote control handset provides all
other functions.
Note: Even if the re is switched on by the external
source, the handset, in the thermostatic mode, controls
the room temperature. The room temperature setting of
the handset will remain the same for the next ON-cycle
of the external source as long as the temperature setting
in the handset has not been changed. If the handset is in
manual mode, it will go to High Fire in the next cycle of
external operation.
• Mode 2 - The handset must be set to the manual mode if
the external source is to control the room temperature.
If the handset is placed in the thermostatic mode it will
override the external source.
NOTE:
Frequent ON and OFF cycles will limit life expectancy of the
valve and will increase battery consumption. The replace
should be powered by the AC adapter for improved
reliability and customer satisfaction.
Element4 Gas Fireplaces EuropeanHome.com
62
Page 63
INDEX
A
APPLIANCE RATINGS 8
AC AdAPTER SPECIFICATIONS 8
C
CERTIFICATION
Listing LabeL8
Massachusetts57
CLEARANCES
Location14
ManteLs16
WarM air outLet(s) 17
E
ELECTRIC
requireMents18
ac adapter specifications8
ENCLOSING ThE FIREPLACE 25
F
FIRE MEdIA
instaLLingthe Logset37
instaLLingthe stones38
FIRST FIRE 47
G
GAS
convertingto Lp 59
instaLLingthe gas Line18
pressures8
K
O
OPERATING ThE FIREPLACE
test fi re36
usingthe reMote controL43
usingthe WaLL sWitch61
P
PARTS OF ThE FIREPLACE 12
S
SAFETY INFORMATION 3
SCREEN INSTALLATION 39
SMART hOME SYSTEM 62
SPECIFICATIONS