Elektronika SKM25ZD-S, SKM22ZD-S, STM25ZE-S, SRRM25ZE-S, STM35ZE-S User Manual

...
1
(OUTDOOR UNIT) SCM60ZD-S
(INDOOR UNIT) SKM22ZD-S STM25ZE-S SRRM25ZE-S SKM25ZD-S STM35ZE-S SRRM35ZE-S SKM28ZD-S STM50ZE-S SRRM50ZE-S SKM35ZD-S STM60ZE-S SRRM60ZE-S SKM50ZD-S
SCM-ZD (3room)
INVERTER MULTI-SPLIT SYSTEM
(Air to air heat pump type)
2
CONTENTS
5.1 GENERAL INFORMATION ........................................................................ 377
5.1.1 Specific features ................................................................................. 377
5.1.2 How to read the model name ............................................................. 377
5.2 SELECTION DATA ..................................................................................... 378
5.2.1 Specifications ...................................................................................... 378
5.2.2 Range of usage & limitations ............................................................. 386
5.2.3 Exterior dimensions............................................................................ 387
5.2.4 Piping system ...................................................................................... 389
5.2.5 Selection chart .................................................................................... 390
5.3 ELECTRICAL DATA................................................................................... 391
5.3.1 Electrical wiring .................................................................................. 391
5.4 OUTLINE OF OPERATION CONTROL BY MICROCOMPUTER ............. 395
5.5 APPLICATION DATA ................................................................................. 419
5.5.1 Installation of indoor unit ................................................................... 420
5.5.2 Installation of remote control............................................................. 429
5.5.3 Installation of outdoor unit................................................................. 430
5.5.4 Electrical wiring .................................................................................. 431
5.5.5 Refrigerant piping ............................................................................... 432
5.5.6 Test run and handling instruction ..................................................... 434
5.5.7 Installation of remote control and super link adapter
(SC-AD-E) (Optional parts) ................................................................ 435
5.5.8 Installation of optional parts (Ducted type) ...................................... 442
5.6 MAINTENANCE DATA ............................................................................... 447
5.6.1 Trouble shooting ................................................................................. 447
5.6.2 Servicing .............................................................................................. 456
5.7 REFRIGERANT PIPING INSTALLATION/SERVICING MANUAL
FOR AIR CONDITIONERS USING R410A ................................................ 456
3
5.1 GENERAL INFORMATION
5.1.1 Specific features
(1) The long piping makes the location of the inside and units flexible.
¡ No need for additional charge of refrigerant : 30m
¡ Maximum piping length : 40m
(2) Connectable indoor capacity
Number of connectable units : 3 units
Total of indoor units (class kW) : 11.0kW
(3) Indoor units are available with 5 capacities.
5 capacities ................ 22, 25, 28, 35, 50, 60
Types ......................... Wall mounted type (SKM).
4-way ceiling cassette type (STM).
Ducted type (SRRM).
(4) Inverter (Frequency converter) for multi-steps power control
¡ Heating / Cooling
The rotational speed of a compressor is changed in step in relation to varying load, to interlock with the indoor and outdoor unit
fans controlled to changes in frequency, thus controlling the power.
¡ Allowing quick heating/cooling operation during start-up period. Constant room temperature by fine-tuned control after the
unit has stabilized.
(5) Fuzzy control
Fuzzy control calculates the amount of variation in the difference between the suction air temperature and the setting temperature
in compliance with the fuzzy rules in order to control the air capacity and the inverter frequency.
(6) Self diagnosis function
We are constantly trying to do better service to our customers by installing such judges that show abnormality of operation as
follows. (See Page 74)
5.1.2 How to read the model name
Example : ST M 25 Z E - S
R410A models
Series No.
Inverter and Heat pump type
Product capacity
Multiple system
Model name
SK : Wall mounted type ST : 4 way ceiling cassette type SRR : Ducted type SC : Outdoor unit
4
Item
Models
SKM22ZD-S SKM25ZD-S SKM28ZD-S SKM35ZD-S
Cooling capacity W 2200 2500 2800 3500
Heating capacity W 3200 3400 4000 4500
Noise level
Cooling
Hi : 37 Me : 30 Lo : 23
Hi : 38 Me : 31 Lo : 24 Hi : 39 Me : 32 Lo : 25
dB
Hi : 53 Hi : 54 Hi : 55
Heating
Hi : 39 Me : 33 Lo : 27
Hi : 40 Me : 34 Lo : 28 Hi : 41 Me : 35 Lo : 29
Hi : 55 Hi : 56 Hi : 57
Exterior dimensions
Height × Width × Depth
mm 250 × 815 × 249
Color Cool white
Net weight kg 9.0
Air handling equipment
Fan type & Q’ty
Tangential fan × 1
Motor W 16
Cooling 8.0 8.2 8.4
Air flow (at high)
Heating
CMM
8.7 9.0 9.2
Air filter, Q’ty
Polypropylene net × 2 (Washable)
Operation switch Wireless-Remote control
Room temperature control M.C thermostat
Pilot lamp RUN (Green), TIMER (Yellow), HI POWER (Green), ECONO (Orange)
Safety equipment
O.D mm (in)
φ 6.35 (1/4″)
φ 9.52 (3/8″)
Connecting method Flare connecting
Attached length of piping Liquid line : 0.4m Gas line : 0.33m
Insulation Necessary (Both Liquid & Gas lines)
Drain hose Connectable
Accessories (including)
Mounting kit, Clean filter (Natural enzyme filter × 1, Photocatalytic washable deodorizing filter × 1)
Optional parts
Outdoor unit to be combined SCM60ZD-S
5.2 SELECTION DATA
5.2.1 Specifications
(1) Indoor unit
Models SKM22ZD-S, 25ZD-S, 28ZD-S, 35ZD-S
(2) Capacity indicated is the rated capacity with one unit operating under ISO-T1 standards conditions.
Refrigerant piping
Liquid line
Gas line
Frost protection, Serial error protection
Fan motor error protection
Notes (1) The data are measured at the following conditions.
Item Indoor air temperature Outdoor air temperature
Standards
Operation DB WB DB WB
Cooling 27ºC 19ºC 35ºC 24ºC ISO-T1, JIS C9612
Heating 20ºC 7ºC 6ºC ISO-T1, JIS C9612
Sound level
Power level
Sound level
Power level
5
Item
Model
SKM50ZD-S
Cooling capacity W 5000
Heating capacity W 5800
Noise level
Cooling
Sound level
dB
Hi : 47 Me : 36 Lo : 23
Power level Hi : 62
Noise level
Heating
Sound level Hi : 48 Me : 37 Lo : 27
Power level Hi : 63
Exterior dimensions
Height × Width × Depth
mm 250 × 815 × 249
Color Cool white
Net weight kg 9.5
Air handling equipment
Fan type & Qty
Tangential fan × 1
Motor W 29
Cooling 11
Air flow (at high)
Heating
CMM
13.9
Air filter, Qty Polypropylene net × 2 (Washable)
Operation switch Wireless-Remote control
Room temperature control M.C thermostat
Pilot lamp RUN (Green), TIMER (Yellow), HI POWER (Green), ECONO (Orange)
Safety equipment
O.D mm (in)
φ 6.35 (1/4″)
φ 12.7 (1/2″)
Connecting method Flare connecting
Attached length of piping Liquid line : 0.4m Gas line : 0.33m
Insulation Necessary (Both Liquid & Gas lines)
Drain hose Connectable
Accessories (including)
Mounting kit, Clean filter (Natural enzyme filter × 1, Photocatalytic washable deodorizing filter × 1)
Optional parts
Outdoor unit to be combined SCM60ZD-S
Item Indoor air temperature Outdoor air temperature
Standards
Operation DB WB DB WB
Cooling 27ºC19ºC35ºC24ºC ISO-T1, JIS C9612
Heating 20ºC 7ºC6ºC ISO-T1, JIS C9612
(2) Capacity indicated is the rated capacity with one unit operating under ISO-T1 standards conditions.
Refrigerant piping
Liquid line
Gas line
Frost protection, Serial error protection
Fan moter error protection
Notes (1) The data are measured at the following conditions.
Model SKM50ZD-S
6
Sound level
Power level
Sound level
Power level
Item
Models
STM25ZE-S STM35ZE-S STM50ZE-S STM60ZE-S
Cooling capacity W 2500 3500 5000 6000
Heating capacity W 3400 4500 5800 6800
Noise level
Cooling
35 38 40 47
dB
51 54 56 63
Heating
35 38 40 47
51 54 56 63
Exterior dimensions
Main unit 248 × 570 × 570
Height × Width × Depth
Panel
mm
35 × 700 × 700
Color
Net weight
Main unit
kg
14 14.5
Panel 3.5
Air handling equipment
Fan type & Qty
Turbo fan × 1
Motor W 40
Cooling 8.0 9.0 10.0 13.0
Air flow (at high)
Heating
CMM
9.0 10.0 11.0 14.0
Air filter, Qty
Long life filter
× 1
(Washable)
Operation switch Wireless-Remote control
Room temperature control M.C thermostat
Pilot lamp RUN (Green), TIMER (Yellow), HI POWER (Green), ECONO (Orange)
Safety equipment
O.D mm (in)
φ 6.35 (1/4″)
φ 9.52 (3/8″) φ 12.7 (1/2″)
Connecting method Flare connecting
Attached length of piping
Insulation Necessary (Both Liquid & Gas lines)
Drain hose Connectable
Accessories (including) Mounting kit
Optional parts Wired remote control
Outdoor unit to be combined SCM60ZD-S
Models STM25ZE-S, 35ZE-S, 50ZE-S, 60ZE-S
(2) Capacity indicated is the rated capacity with one unit operating under ISO-T1 standards conditions.
Refrigerant piping
Liquid line
Gas line
Frost protection, Serial error protection
Fan motor error protection, Drain error protection
Notes (1) The data are measured at the following conditions.
Item Indoor air temperature Outdoor air temperature
Standards
Operation DB WB DB WB
Cooling 27ºC19ºC35ºC24ºC ISO-T1, JIS C9612
Heating 20ºC 7ºC6ºC ISO-T1, JIS C9612
7
Sound level
Power level
Sound level
Power level
Models SRRM25ZE-S, 35ZE-S, 50ZE-S, 60ZE-S
Item
Models
SRRM25ZE-S SRRM35ZE-S SRRM50ZE-S SRRM60ZE-S
Cooling capacity W 2500 3500 5000 6000
Heating capacity W 3400 4500 5800 6800
Noise level
Cooling
38 40 46 49
dB
53 55 60 63
Heating
39 41 46 49
54 56 60 63
Exterior dimensions
Height × Width × Depth
mm 230 × 740 × 455
Color
Net weight kg 22.0 23.0
Air handling equipment
Fan type & Qty
Centrifugal fan × 2
Motor W 51
Cooling 8.5 9.0 10.5 12.5
Air flow (at high)
Heating
CMM
10.0 11.0 13.0 15.0
Air filter, Qty
Polypropylene net × 1
Operation switch Wireless-Remote control
Room temperature control M.C thermostat
Pilot lamp RUN (Green), TIMER (Yellow), HI POWER (Green), ECONO (Orange)
Safety equipment
O.D mm (in)
φ 6.35 (1/4″)
φ 9.52 (3/8″) φ 12.7 (1/2″)
Connecting method Flare connecting
Attached length of piping
Insulation Necessary (Both Liquid & Gas lines)
Drain hose Connectable
Accessories (including) Mounting kit
Optional parts Wired remote control
Outdoor unit to be combined SCM60ZD-S
(2) Capacity indicated is the rated capacity with one unit operating under ISO-T1 standards conditions.
Refrigerant piping
Liquid line
Gas line
Frost protection, Serial error protection
Fan motor error protection, Drain error protection
Notes (1) The data are measured at the following conditions.
Item Indoor air temperature Outdoor air temperature
Standards
Operation DB WB DB WB
Cooling 27ºC19ºC35ºC24ºC ISO-T1, JIS C9612
Heating 20ºC 7ºC6ºC ISO-T1, JIS C9612
8
(2) Outdoor unit
Model SCM60ZD-S
Item
Model
SCM60ZD-S
Cooling capacity W 6000 (1400~6900)
Heating capacity W 7000 (750~7200)
Power source 1 Phase 220/230/240V 50Hz
Power consumption
Cooling
W
1860 (400~3000)
Heating 1740 (320~2700)
Running current
Cooling 8.5/8.2/7.8
Heating
A
8.0/7.6/7.3
Sound level Cooling : 48/48/50 Heating : 50/50/52
Noise level
Power level
dB
Cooling : 63/63/65 Heating : 65/65/67
Exterior dimensions
Height × Width × Depth
mm
640 × 850 × 290
Color Stucco white
Net weight kg 51
Refrigerant equipment
Compressor type & Q’ty
TNB220FLBM1 [Twin rotary type] × 1
Motor kW 1.3
Starting method Direct start
Refrigerant control Capillary tubes + Electronic expansion valve
Refrigerant kg R410A 2.2 (Pre-charged up to the piping length of 30m)
Refrigerant oil R 0.67 (MEL56)
Air handling equipment
Fan type & Qty
Propeller fan × 1
Motor W 45
Air flow (at high) CMM 42
Shock & vibration absorber Rubber (for compressor)
Safety equipment
Size × Core × Number mm (in)
Liquid line: φ 6.35 (1/4″) × 3
Gas line: φ 9.52 (3/8) × 3
Connecting method Flare connecting
Attached length piping
Insulation Necessary (Both Liquid & Gas lines)
Power source supply Terminal block (Screw fixing type)
Size × Core number 1.5 mm2 × 4 cores (Including earth cable) × 3
Connecting method Terminal block (Screw fixing type)
Accessories (included)
Union : (φ 9.52 / φ 12.7) × 2
Installation sheet, Manual instruction
SKM22, 25, 28, 35, 50 type
Indoor units to be combined STM25, 35, 50, 60 type
SRRM25, 35, 50, 60 type
Compressor overheat protection, Overcurrent protection
Serial signal error protection
Notes (1) The data are measured at the following conditions.
Refrigerant piping
Connection wiring
Item Indoor air temperature Outdoor air temperature
Standards
Operation DB WB DB WB
Cooling 27ºC19ºC35ºC24ºC ISO-T1, JIS C9612
Heating 20ºC 7ºC6ºC ISO-T1, JIS C9612
(2) The values for capacity and power consumption shown in a range ( ) indicate the minimum and maximum of the range.
(3) If the piping length exceeds 30 m, additional charging is required. (20g/m)
9
(3) Operation data
¡ The combinations of the indoor units is indicated by numbers. They are read as follows.
(Example) SKM22ZD-S / 22 SKM35ZD-S / 35
¡ The capacity of the indoor units is shown by rooms. If this exceeds the maximum capacity of the outdoor unit, the demand
capacity will be proportionally distributed.
¡ If units are to be combined, use the table below to make the proper selection.
Model SCM60ZD-S
(a) Heating
1
room
22 3.2 - - 0.75 3.2 3.4 320 1100 1200 5.1 4.8 4.6
25 3.4 - - 0.75 3.4 3.6 320 1200 1300 5.5 5.3 5.1
28 4.0 - - 0.75 4.0 4.2 320 1450 1550 6.7 6.4 6.1
35 4.5 - - 0.75 4.5 4.6 320 1750 1800 8.0 7.7 7.4
50 5.8 - - 0.75 5.8 6.2 320 2100 2400 9.6 9.2 8.8
11.9
10.3
11.4
10.1
10.9
60 6.8 - - 0.75 6.8 6.9 320 2600 2650
2
room
22+22 2.55 2.55 - 1.1 5.1 6.5 330 1450 2350 6.7 6.4 6.1
22+25 2.48 2.82 - 1.1 5.3 6.5 330 1500 2350 6.9 6.6 6.3
22+28 2.55 3.25 - 1.1 5.8 6.5 330 1700 2400 7.8 7.5 7.2
22+35 2.35 3.75 - 1.1 6.1 6.6 330 1900 2500 8.7 8.3 8.0
22+50 2.02 4.58 - 1.2 6.6 6.8 360 2150 2700 9.9 9.4 9.0
9.9 9.5
10.6 9.7
22+60 1.80 4.90 - 1.2 6.7 6.8 360 2250 2700
25+25 2.75 2.75 - 1.1 5.5 6.5 330 1600 2350 7.3 7.0 6.7
25+28 2.78 3.12 - 1.1 5.9 6.5 330 1800 2400 8.3 7.9 7.6
25+35 2.63 3.68 - 1.1 6.3 6.6 330 2000 2500 9.2 8.8 8.4
25+50 2.23 4.47 - 1.2 6.7 6.8 360 2250 2700 10.3 9.9 9.5
25+60 1.97 4.73 - 1.2 6.7 6.8 360 2300 2700
28+28 3.20 3.20 - 1.1 6.4 6.6 330 2050 2450 9.4 9.0 8.6
28+35 2.98 3.72 - 1.1 6.7 6.7 330 2200 2550 10.1 9.7 9.3
28+50 2.41 4.29 - 1.2 6.7 6.8 360 2400 2700 11.0 10.5 10.1
11.2 10.8 10.3
28+60 2.13 4.57 - 1.2 6.7 6.8 360 2450 2700
35+35 3.35 3.35 - 1.1 6.7 6.7 330 2350 2600 10.8 10.3 9.9
35+50 2.76 3.94 - 1.2 6.7 6.8 360 2550 2700 11.7 11.2 10.7
11.9 11.4 10.9
35+60 2.47 4.23 - 1.2 6.7 6.8 360 2600 2700
50+50 3.35 3.35 - 1.5 6.7 6.8 420 2600 2700 11.9 11.4 10.9
12.2 11.6 11.2
50+60 3.05 3.65 - 1.5 6.7 6.8 420 2650 2700
3
room
22+22+22
2.23 2.23 2.23 1.7 6.7 7.2 440 1650 2700 7.6 7.2 6.9
22+22+25
2.20 2.20 2.50 1.7 6.9 7.2 440 1750 2700 8.0 7.7 7.4
22+22+28
2.14 2.14 2.72 1.7 7.0 7.2 440 1800 2700 8.3 7.9 7.6
22+22+35
1.95 1.95 3.10 1.7 7.0 7.2 440 1850 2700 8.5 8.1 7.8
22+22+50
1.64 1.64 3.72 1.9 7.0 7.2 500 1740 2700 8.0 7.6 7.3
9.0 8.6 8.2
22+22+60
1.50 1.50 4.10 1.9 7.1 7.2 500 1950 2700
22+25+25
2.14 2.43 2.43 1.7 7.0 7.2 440 1750 2700 8.0 7.7 7.4
22+25+28
2.05 2.33 2.61 1.7 7.0 7.2 440 1850 2700 8.5 8.1 7.8
22+25+35
1.88 2.13 2.99 1.7 7.0 7.2 440 1950 2700 9.0 8.6 8.2
22+25+50
1.61 1.83 3.66 1.9 7.1 7.2 500 2050 2700 9.4 9.0 8.6
9.4 9.0 8.6
22+25+60
1.46 1.66 3.98 1.9 7.1 7.2 500 2050 2700
22+28+28
1.97 2.51 2.51 1.7 7.0 7.2 440 1950 2700 9.0 8.6 8.2
22+28+35
1.84 2.34 2.92 1.7 7.1 7.2 440 2050 2700 9.4 9.0 8.6
22+28+50
1.56 1.99 3.55 1.9 7.1 7.2 500 2100 2700 9.6 9.2 8.8
9.6 9.2 8.8
22+28+60
1.42 1.81 3.87 1.9 7.1 7.2 500 2100 2700
22+35+35
1.70 2.70 2.70 1.7 7.1 7.2 440 2150 2700 9.9 9.4 9.0
10.1 9.7 9.3
22+35+50
1.46 2.32 3.32 1.9 7.1 7.2 500 2200 2700
25+25+25
2.33 2.33 2.33 1.7 7.0 7.2 440 1800 2700 8.3 7.9 7.6
25+25+28
2.24 2.24 2.51 1.7 7.0 7.2 440 1900 2700 8.7 8.3 8.0
Indoor unit combinaton
Cooling capacity (kW)
Power cosumption (W) Standard current (kW)
Roomcooling capacity (kW) Total capacity (kW)
Min. Standard Max. 220V 230V 240V
B room C room
Min. Standard Max.
A room
10
25+25+35
2.06 2.06 2.88 1.7 7.0 7.2 440 2000 2700 9.2 8.8 8.4
25+25+50
1.78 1.78 3.55 1.9 7.1 7.2 500 2050 2700 9.4 9.0 8.6
9.4 9.0 8.6
25+25+60
1.61 1.61 3.87 1.9 7.1 7.2 500 2050 2700
25+28+28
2.19 2.45 2.45 1.7 7.1 7.2 440 2000 2700 9.2 8.8 8.4
25+28+35
2.02 2.26 2.82 1.7 7.1 7.2 440 2100 2700 9.6 9.2 8.8
25+28+50
1.72 1.93 3.45 1.9 7.1 7.2 500 2250 2700 10.3 9.9 9.5
25+35+35
1.87 2.62 2.62 1.7 7.1 7.2 440 2200 2700 10.1 9.7 9.3
10.3 9.9 9.5
25+35+50
1.61 2.26 3.23 1.9 7.1 7.2 500 2250 2700
28+28+28
2.37 2.37 2.37 1.7 7.1 7.2 440 2150 2700 9.9 9.4 9.0
28+28+35
2.18 2.18 2.73 1.7 7.1 7.2 440 2200 2700 10.1 9.7 9.3
28+28+50
1.88 1.88 3.35 1.9 7.1 7.2 500 2350 2700 10.8 10.3 9.9
28+35+35
2.03 2.54 2.54 1.7 7.1 7.2 440 2300 2700 10.6 10.1 9.7
35+35+35
2.37 2.37 2.37 1.7 7.1 7.2 440 2400 2700 11.0 10.5 10.1
3
room
Indoor unit combinaton
Cooling capacity (kW)
Power cosumption (W) Standard current (kW)
Roomcooling capacity (kW) Total capacity (kW)
Min. Standard Max. 220V 230V 240V
B room C room
Min. Standard Max.
A room
(b) Cooling
1
room
22 2.2 - - 1.4 2.2 2.3 400 720 750 3.3 3.2 3.0
25 2.5 - - 1.4 2.5 2.6 400 800 830 3.7 3.5 3.4
28 2.8 - - 1.4 2.8 3.0 400 950 1050 4.4 4.2 4.0
35 3.5 - - 1.4 3.5 3.6 400 1300 1350 6.0 5.7 5.5
50 5.0 - - 1.4 5.0 5.1 400 2200 2250 10.1 9.7 9.3
60 6.0 - - 1.4 6.0 6.1 400 2700 2800
2
room
22+22 2.20 2.20 - 1.5 4.4 4.6 410 1450 1650 6.7 6.4 6.1
22+25 2.20 2.50 - 1.5 4.7 4.9 410 1600 1750 7.3 7.0 6.7
22+28 2.20 2.80 - 1.5 5.0 5.2 410 1720 1900 7.9 7.6 7.2
22+35 2.05 3.25 - 1.5 5.3 5.4 410 2100 2150 9.6 9.2 8.8
22+50 1.86 4.24 - 1.6 6.1 6.4 440 2550 2750 11.7 11.2 10.7
12.9 12.3 11.8
12.4 11.9 11.4
22+60 1.74 4.76 - 1.6 6.5 6.6 440 2800 2880
25+25 2.50 2.50 - 1.5 5.0 5.2 410 1720 1900 7.9 7.6 7.2
25+28 2.50 2.80 - 1.5 5.3 5.4 410 1850 1950 8.5 8.1 7.8
25+35 2.42 3.38 - 1.5 5.8 5.9 410 2200 2300 10.1 9.7 9.3
25+50 2.10 4.20 - 1.6 6.3 6.5 440 2720 2850 12.5 11.9 11.4
13.2 12.6 12.1
13.2 12.6 12.1
13.2 12.6 12.1
13.2 12.6 12.1
25+60 1.94 4.66 - 1.6 6.6 6.6 440 2880 2880
28+28 2.80 2.80 - 1.5 5.6 5.7 410 2000 2100 9.2 8.8 8.4
28+35 2.71 3.39 - 1.5 6.1 6.2 410 2420 2500 11.1 10.6 10.2
28+50 2.37 4.23 - 1.6 6.6 6.6 440 2880 2880 13.2 12.6 12.1
28+60 2.10 4.50 - 1.6 6.6 6.6 440 2880 2880
35+35 3.30 3.30 - 1.5 6.6 6.6 410 2880 2880 13.2 12.6 12.1
35+50 2.72 3.88 - 1.6 6.6 6.6 440 2880 2880 13.2 12.6 12.1
35+60 2.43 4.17 - 1.6 6.6 6.6 440 2880 2880
50+50 3.30 3.30 - 1.9 6.6 6.6 500 2880 2880 13.2 12.6 12.1
50+60 3.00 3.60 - 1.9 6.6 6.6 500 2880 2880
Cooling capacity(kW)
220V 230V 240V
Indoor unit combinaton
Roomcooling capacity (kW) Total capacity (kW)
Power cosumption (W) Standard current (kW)
Min. Standard Max.
B room C room
Min. Standard Max.
A room
11
3
room
22+22+22
1.70 1.70 1.70 1.9 5.1 6.8 620 1470 2950 6.7 6.5 6.2
22+22+25
1.66 1.66 1.88 1.9 5.2 6.8 620 1500 2950 6.9 6.6 6.3
22+22+28
1.59 1.59 2.02 1.9 5.2 6.9 620 1500 3000 6.9 6.6 6.3
22+22+35
1.50 1.50 2.39 1.9 5.4 6.9 620 1600 3000 7.3 7.0 6.7
22+22+50
1.40 1.40 3.19 2.1 6.0 6.9 680 1860 3000 8.5 8.2 7.8
9.2 8.8 8.4
9.2 8.8 8.4
9.2 8.8 8.4
22+22+60
1.29 1.29 3.52 2.1 6.1 6.9 680 2000 3000
22+25+25
1.59 1.81 1.81 1.9 5.2 6.9 620 1500 3000 6.9 6.6 6.3
22+25+28
1.55 1.77 1.98 1.9 5.3 6.9 620 1550 3000 7.1 6.8 6.5
22+25+35
1.48 1.68 2.35 1.9 5.5 6.9 620 1620 3000 7.4 7.1 6.8
22+25+50
1.36 1.55 3.09 2.1 6.0 6.9 680 1860 3000 8.5 8.2 7.8
22+25+60
1.27 1.45 3.48 2.1 6.2 6.9 680 2000 3000
22+28+28
1.52 1.94 1.94 1.9 5.4 6.9 620 1600 3000 7.3 7.0 6.7
22+28+35
1.45 1.84 2.31 1.9 5.6 6.9 620 1650 3000 7.6 7.2 6.9
22+28+50
1.32 1.68 3.00 2.1 6.0 6.9 680 1860 3000 8.5 8.2 7.8
9.4 9.0 8.6
22+28+60
1.26 1.60 3.44 2.1 6.3 6.9 680 2050 3000
22+35+35
1.39 2.21 2.21 1.9 5.8 6.9 620 1750 3000 8.0 7.7 7.4
22+35+50
1.27 2.03 2.90 2.1 6.2 6.9 680 2000 3000
25+25+25
1.77 1.77 1.77 1.9 5.3 6.9 620 1550 3000 7.1 6.8 6.5
25+25+28
1.73 1.73 1.94 1.9 5.4 6.9 620 1600 3000 7.3 7.0 6.7
25+25+35
1.65 1.65 2.31 1.9 5.6 6.9 620 1650 3000 7.6 7.2 6.9
25+25+50
1.50 1.50 3.00 2.1 6.0 6.9 680 1860 3000 8.5 8.2 7.8
9.4 9.0 8.6
25+25+60
1.43 1.43 3.44 2.1 6.3 6.9 680 2050 3000
25+28+28
1.70 1.90 1.90 1.9 5.5 6.9 620 1620 3000 7.4 7.1 6.8
25+28+35
1.62 1.81 2.27 1.9 5.7 6.9 620 1700 3000 7.8 7.5 7.2
25+28+50
1.48 1.66 2.96 2.1 6.1 6.9 680 2000 3000 9.2 8.8 8.4
25+35+35
1.55 2.17 2.17 1.9 5.9 6.9 620 1800 3000 8.3 7.9 7.6
9.4 9.0 8.6
25+35+50
1.43 2.00 2.86 2.1 6.3 6.9 680 2050 3000
28+28+28
1.87 1.87 1.87 1.9 5.6 6.9 620 1650 3000 7.6 7.2 6.9
28+28+35
1.78 1.78 2.23 1.9 5.8 6.9 620 1750 3000 8.0 7.7 7.4
28+28+50
1.64 1.64 2.92 2.1 6.2 6.9 680 2100 3000 9.6 9.2 8.8
28+35+35
1.69 2.11 2.11 1.9 5.9 6.9 620 1800 3000 8.3 7.9 7.6
35+35+35
2.07 2.07 2.07 1.9 6.2 6.9 620 2100 3000 9.6 9.2 8.8
Cooling capacity(kW)
220V 230V 240V
Indoor unit combinaton
Roomcooling capacity (kW) Total capacity (kW)
Power cosumption (W) Standard current (kW)
Min. Standard Max.
B room C room
Min. Standard Max.
A room
12
5.2.2 Range of usage & limitations
Indoor intake air temperature (Upper, lower limits)
Indoor units that can be used in combination
Length for one indoor unit
Total length for all rooms
Max. 25m
Max. 40m
11.0kW
2 to 3 units
SCM60ZD-S
Refer to the selection chart.
Compressor stop/start frequency
Power source voltage
1 cycle time
Stop time
Voltage fluctuation
Voltage drop during start
Interval unbalance
Difference in height between indoor units (C)
Within ±3% of rated voltage
Within ±15% of rated voltage
Within ±10% of rated voltage
3 min or more
6 min or more (from stop to stop or from start to start)
Max. 25m
Max. 15m
Max. 10m
Outdoor air temperature (Upper, lower limits)
Number of connected units
Total of indoor Units (class kW)
Difference in height between indoor and outdoor units
When above outdoor unit (B)
When below outdoor unit (A)
Item
Model
A
B
C
13
VIEW A
45
14.5
60
788
5
60
45
815
A
250
117.5
580 117.5
148.5
216.5216.5
8.2
44.5
236.1
5.7
450
450
67.5
42.7
47.2
175
44.5
216.5216.5
148.5
53.5
Piping for Gas
Drain hose 540 (ø16)
Piping for Liquid 465.1 (ø6.35)
Piping hole (ø65)
Piping hole (ø65)
( )
22,25,28,35: ø9.52 50: ø12.7
397.1
Piping hole right(left)
Terminal block
9
60
45
3
249
150
18
56
Remote controller
5.2.3 Exterior dimensions
(1) Indoor unit
Models SKM22ZD-S, 25ZD-S, 28ZD-S, 35ZD-S, 50ZD-S
Unit : mm
Models STM25ZE-S, 35ZE-S, 50ZE-S, 60ZE-S
Hanging bolt pitch 530
Celling opening 660 (For conventional celling)
Hanging fixture
C
B
A
D
Drain hose (accessory) To be installed at site
Control box
Hanging bolt pitch 530
Air outlet
Air intake
PANEL
E
*Please arrange VP25 connector sockets on the installer's part.
350
319
104
more
45 or
541
700
413
43202
570
243
196
250
93
35
137
197
68
Mark Description
Model 25,35ZE-S 50,60ZE-S
A
Gas pipe connecting port ø 9.52(Flare) ø 12.7(Flare)
B
Liquid pipe connecting port ø 6.35(Flare)
C
Drain line tube connecting port VP25*
D
Power intake
E
Hanging bolt (M10 or M8)
14
Models SRRM25ZE-S, 35ZE-S, 50ZE-S, 60ZE-S
(2) Outdoor unit Model SCM60ZD-S
42.7
42.7
42.7
Drain holes
Elogated hole (2-12X16)
Terminal block
Gas line service valve C Unit (ø9.52)
Liquid line service
valve C Unit (ø6.35)
Liquid line service valve B Unit (ø6.35)
Gas line service valve B Unit (ø9.52)
Liquid line service valve A Unit (ø6.35)
Gas line service valve A Unit (ø9.52)
Ground terminal
314
14
12
850
203.1 510 136.9
476
286.4
12
50
290
49.6
43.5
328
100.3
67.9
67.9
15
640
124
34.6
20º
20º
Unit : mm
Controller
Terminal block
Air outlet
ø 4 × 8(Holes for tapping screws)
B
A
Air inlet
Hanging bolt
(M8 × 4)
35 670 (Suspension bolts pitch)
740
35
515 (Suspension bolts pitch)
455 3030
325
455
106740
150
38
78135
30 230 11 255
236
105
Drain hose
(Connection opening diameter ø16)
220 90 220 105
3014855
1917044
100 540 100
Mark
Description
Model 25,35ZE-S 50,60ZE-S
A
Gas pipe connecting port ø9.52(Flare) ø12.7(Flare)
B
Liquid pipe connecting port
ø6.35(Flare)
15
Gas line
Liquid line
(ø9.52 or ø12.7)
(ø9.52 or ø12.7)
(ø6.35)
(ø6.35)
(ø6.35)
EEVA
Strainer
EEVB
EEVC
(ø9.52 or ø12.7)
Service valve (Gas)
Outdoor Unit
Indoor Unit
Sensor
(Th
I-
R
2
)
Heat exchanger
Sensor
(Th
I-A
)
Sensor
(Th
I-R1
)
Sensor
(Th
O-D
)
Sensor
(Th
O-A
)
Accumlator
Accumlator
Muffler
Sensor
(Th
o-C
)
Service valve
(Liquid)
Electronic
expansion valve
Gas line 22, 25, 28, 35 type:
ø9.52
50, 60 type :
ø12.7
Capillary
tube
Compressor
Check joint
4way valve
Heating
Cooling
Discharge
Suction
Receiver
Sensor
(Th
O
-R)
Heat exchanger
5.2.4 Piping system
Model SCM60ZD-S
16
5.2.5 Selection chart
Correct the cooling and heating capacity in accordance with the conditions as follows. The net cooling and heating capacity can be
obtained in the following way.
Net capacity = Capacity shown on specification × Correction factors as follows.
(1) Coefficient of cooling and heating capacity in relation to temperatures
15
ISO-T1 Standard ConditionOutdoor air W.B. temperature °C W.B.
010-10 -5 5
14 16 18 20 22
15
10
27 25
20
15
20
25
30
35
40
0.6
0.7
0.8
0.9
1.0
1.1
1.2
1.3
43
24
20
ISO-T1 Standard ConditionIndoor air W.B. temperature °C W.B.
Heating
Cooling
Applicable range
Coefficient of cooling &
Heating capacity in
relation to temperature
Cooling operation
Outdoor air D.B.
temperature
°C D.B.
Heating operation
Indoor air D.B.
temperature
°C D.B.
Air inlet temperature of
outdoor unit in ºCWB
Adjustment coefficient
-10
0.95-90.94-70.93-50.91-30.88-10.8610.8730.9251.00
Piping length [m]
Cooling
Heating
7
1.0
1.0
10
0.99
1.0
15
0.975
1.0
20
0.965
1.0
25
0.95
1.0
(2) Correction of cooling and heating capacity in relation to one way length of refrigerant piping
It is necessary to correct the cooling and heating capacity in relation to the one way piping length between the indoor and outdoor
units.
(3) Correction relative to frosting on outdoor heat exchanger during heating
In additions to the foregoing corrections (1), (2) the heating capacity needs to be adjusted also with respect to the frosting on the
outdoor heat exchanger.
17
5.3 ELECTRICAL DATA
Meaning of marks
• Outdoor Unit
• Indoor Unit
FM
I
CF
I
SM
Tr
ZNR
F
Parts name
Fan motor
Capacitor (for FM
I
)
Flap motor
Transformer
Varistor
Fuse
Symbol
DM
FS
Th
I
-A
Th
I-R1
ThI-R
2
Parts name
Drain motor
Float switch
Sensor (room temp.)
Sensor (indoor H.X temp.)
Sensor (indoor H.X temp.)
Symbol
CM
FM
O
CFO
L
DS1
Q11
Parts name
Compressor motor
Fan motor
Capacitor (for FM
O)
Reactor
Diode stack
Power transistor
Symbol
EEVA ~ D
20S
Tho-A
Tho-R
Tho-D
Tho-C
Parts name
Electronic expansion valve
4 way valve (coil)
Sensor (outdoor air temp.)
Sensor (outdoor H.X temp.)
Sensor (discharge pipe temp.)
Sensor (suction pipe temp.)
Symbol
5.3.1 Electrical wiring
(1) Indoor unit
Models SKM22ZD-S, 25ZD-S, 28ZD-S, 35ZD-S
CNW
CF
I
HEAT EXCHANGER
Power line (Outdoor unit)
CNM
CNU
CNC
Tr
F
(250V 3.15A)
Printed circuit
board
1
52C-4
N
ZNR
IC8
3
5
1
WH
2/N
3
SM
FM
I
BK
RD
WH
Y/GN
RD
WH
BR
TB
RD
J
Y/GN
G
BK
CNB
CNE
CNG CNF
Back up switch
ThI-A ThI-R
2
ThI-R
1
Display
Wireless
R-Amp
Black Brown Red White Yellow/Green
BK BR RD WH Y/GN
Color symbol
18
HEAT EXCHANGER
Power line (Outdoor unit)
CNM
F
(250V 3.15A)
Printed circuit
board
1
52C-4
N
~~
ZNR
WH
2/N
3
SM
FM
I
BK
RD
WH
Y/GN
RD
1
3
4
5
6
WH
BL
CNU
Y
BK
TB
RD
J
Y/GN
G
BK
CNE
CNG CNF
Back up switch
ThI-A ThI-R
2
ThI-R
1
Display
Wireless
R-Amp
Black
Brown Red White
Yellow/Green
BK
BR RD WH
Blue
Yellow
BL
Y Y/GN
Color symbol
Model SKM50ZD-S
19
Models STM25ZE-S, 35ZE-S, 50ZE-S, 60ZE-S
Models SRRM25ZE-S, 35ZE-S, 50ZE-S, 60ZE-S
Display
Wireless
R-amp
Display
Wireless
R-amp
DM
DM
FS
FS
Tr
SM
SM
FM
I
FM
I
BK
BK
Printed circuit
board
F
(250V 3.15A)
ZNR
Printed circuit
board
(Optional parts)
(Optional
parts)
F
(250V 3.15A)
ZNR
13 546
G
2/N
Power line
(Outdoor unit)
13
J
R/L
S/N
Control
box
Control
box
YXZXYZ
BK
RD
T2
T1
Wired remote control
(Optional parts)
Power line
(Outdoor unit)
Wired remote control
(Optional parts)
T1
CNG
CNP
CNE
CNQ
CNM
CNU
13 546
G
CNC
1
2/N
3
S/N
J
R/L
CNB
YXZXYZ
T2
ThI-A ThI-R1ThI-R
2
ThI-A ThI-R1ThI-R
2
Y
BL
Y
BKRDWH
WH
BK
RD
Y/G
Y/G
RD
BK
WH
BK
WH
RD
RD
RD
BL
Y
BKRDWH
BK
BK
Y/G
OR
WH
BK
Y/G
RD
RD
BK
WH
WH BK
RD
BK
Color symbol
BL
Y/G
Black Blue
Yellow/Green
WH White
RD Red Y Yellow
BK
Color symbol
BL OR
Y/G
Black Blue Orange
Yellow/Green
WH White
RD Red Y Yellow
CNP
CNE
CNG
CNQ
CNM
CNU
CNB
20
SWITCHING
POWER CIRCUIT
EEV-C
P
L-1
N-1
L
N
BK
WH
1
2
3
RD
20S
G2
~
~
+
-
CNI
RAM DATA
URD
W
CM
V
PWB ASSY(POWER) PWB2
F1
250V 20A
F1
200V 2A
EEV-BEEV-A
Tho-D
Tho-A
Tho-R
Tho-C
1
2
3
4
5
6
7
8
HEATER
F
250V 20A
EARTH
1
2
3
BR
1
2
3
BL
BK
BK
BK
WH
WH
WH
1122
CNO
CNP
CNQ
CNB CNC
CND
CNJ CNK CNL
CNG
RD
BK
P_1N_1
P_1
123456 123456 123456
12
CNN CNH
1234567891011121312345
12345 12345678910111213
PWB ASSY(CAPACITOR) PWB3
PWB ASSY(CPU) PWB1
NW
V
U
DC-P
DC-N
N1
L
N2
P2
BK
C1 C2 C3 C4
2
1
IC12 Q11
RD
BK RD
BL
GR
BL
GR
L-OUT2
AC.L
AC.N
N-OUT2
CNG
CNH
T1
T2
DS1
AF-L2
N_3
G3
AF-L1
OR OR
L
OR OR
Y/G
Y/G Y/G
WH
BK
WH
BK
Power source
1 Phase
220/230/240V
Unit
A
Unit
B
Unit
C
Black
Red
White
Yellow/Green
BK
RD
WH
Blue
Yellow
BL
Brown
BR
Gray
GR
Orange
OR
Y
Y/GN
Color symbol
NF
NF
NF
LED4
Unit A
LED5
ERROR
LED2
Unit C
LED3
Unit B
FMo
CNS
1
3
7
5
CAP1
CAP2
Me
Lo
COM
CFO
OR
Y
BK
BL
RD
WH
(2) Outdoor unit
Model SCM60ZD-S
21
LO
MED
HI
AUTO
HI POWER
ECONO
ON OFF
AM PM
HI POWER
TEMP
ECONO
AIR FLOW
CANCEL
ON OFF
RESERVE
TIMER
TIME
ACL
FAN SPEED
ON
MODE
LO
MED
HI
AUTO
TIME
OFF
HI POWER
ECONO
ON OFF
AM PM
FAN SPEED button
Each time the button is pushed, the indi­cator is switched over in turn.
The above illustration shows all controls, but in practice
only the relevant parts are shown.
OPERATION MODE select button
Each time the button is pushed, the indi­cator is switched over in turn.
AIR FLOW button
This button changes the flap mode. When pressed, this button changes the mode in the following order:
ON/OFF button
Press for starting operation, press again for stopping.
HI POWER button
This button changes the HI POWER mode.
ECONOMY button
This button changes the ECONOMY mode.
RESET switch
Switch for resetting microcomputer.
ON TIMER button
This button selects ON TIMER operation.
Clock switch
This switch for setting the clock.
OFF TIMER button
This button selects OFF TIMER operation.
TEMPERATURE button
This button sets the room temperature. (This button changes the present time and
TIMER time.)
CANCEL button
This button cancels the ON timer and OFF timer.
RESERVE button
This button sets the present time and TIMER time.
S Indication section
OPERATION MODE indicator
Indicates selected operation with lamp.
[
(Auto) (Cool) (Heat) (Dry)]
TEMPERATURE indicator
Indicates set temperature. (Does not indicate temperature when operation
mode is on AUTO)
FAN SPEED indicator
Indicates set air flow rate with lamp.
AIR FLOW indicator
Shows selected flap mode.
HI POWER MODE indicator
Indicates during Hi power mode operation.
ECONOMY MODE indicator
Indicates during economy mode operation.
ON TIMER indicator
Indicates during ON TIMER operation.
Clock indicator
Indicates present time or timer setting time.
OFF TIMER indicator
Indicates during OFF TIMER operation.
(a) Wireless remote control
Models All models
S Operation section
(Air scroll) (Swing)
5.4 OUTLINE OF OPERATION CONTROL BY MICROCOMPUTER
(1) Operation control function by remote control switch
This button is not used for SRRM-ZE series. (Air flow direction adjustment can not be performed.)
(Flap stopped)
22
(b) Wired remote control (Optional parts)......STM, SRRM only
The figure below shows the remote controller with the cover opened. Note that all the items that may be displayed in the liquid crystal
display area are shown in the figure for the sake of explanation.
Characters displayed with dots in the liquid crystal display area are abbreviated.
Pull the cover downward to open it.
Weekly timer display
Displays the settings of the weekly timer.
[Vent Indicator]
Indicates operation in the Ventilation mode.
Operation/Stop switch
This switch is used to operate and stop the air conditioning system. Press the switch once to operate the system and press it once again to stop the system.
MODE switch
This switch is used to switch between operation modes.
Operation setting display area
Displays setting temperature, airflow volume, operation mode and operation message.
Operation/Check indicator light
During operation: Lit in green In case of error: Flashing in red
FAN SPEED switch
This switch is used to set the airflow volume. (AUTO, HI POWER or ECONO cannot be selected.)
SET switch
This switch is used to apply the timer operation setting. This switch is also used to make silent mode operation settings.
[RESET switch]
Press this switch while making settings to go back to the previous operation. This switch is also used to reset the
FILTER CLEANING message display.
(Press this switch after cleaning the air filter.)
Central control display
Displayed when the air conditioning system is controlled by the option controller.
Timer operation display
Displays the settings related to timer operation.
AIR CON No. (Air conditioning system No.) switch
Displays the number of the connected air conditioning system.
[CHECK switch]
This switch is used at servicing.
[TEST switch]
This switch is used during test operation.
Temperature setting switches
These switches are used to set
the temperature of the room.
[VENT switch]
Switch that operates the connected ventilator.
Timer setting switches
These switches are used to set the timer mode and time.
TIMER switch
This switch is used to select a timer mode. (The comfortable timer cannot be selected.)
[GRILL switch]
This switch has no function. When this switch is pressed, (Invalid Operation) is displayed, but it does not mean a failure.
LOUVER switch
This switch is used to operate/stop the swing louver. This button is not used for SRRM-ZE series. (Air flow direction adjustment can not be performed.)
* If you oress any of the switches above and INVALID OPER is display, the switch has no function. But it does not mean a failure.
Note (1) The STM, SRRM models don't support the switches and functions displayed in [ ].
23
RUN (HOT KEEP) light (green)
Illuminates during operation.
Blinks at air flow stop due to the HOT KEEP’.
ECONOMY light (orange)
Illuminates during ECONOMY operation.
TIMER light (yellow)
Illuminates during TIMER operation.
HI POWER light (green)
Illuminates during HI POWER operation.
Models STM25ZE-S, 35ZE-S, 50ZE-S, 60ZE-S
Models SRRM25ZE-S, 35ZE-S, 50ZE-S, 60ZE-S
RUN (HOT KEEP) light (green)
Illuminates during operation.
Blinks at air flow stop due to the HOT KEEP’.
TIMER light (yellow)
Illuminates during TIMER operation.
RUN (HOT KEEP) light (green)
Illuminates during operation.
Blinks at air flow stop due to the HOT KEEP’.
ECONOMY light (orange)
Illuminates during ECONOMY operation.
TIMER light (yellow)
Illuminates during TIMER operation.
HI POWER light (green)
Illuminates during HI POWER operation.
ECONOMY light (orange)
Illuminates during ECONOMY operation.
HI POWER light (green)
Illuminates during HI POWER operation.
(c) Unit indication section
Models SKM22ZD-S, 25ZD-S, 28ZD-S, 35ZD-S, 50ZD-S
24
(2) Unit ON/OFF button
When the remote control batteries become weak, or if the remote control is lost or malfunctioning, this button may be used to turn
the unit on and off.
(a) Operation
Push the button once to place the unit in the automatic mode. Push it once more to turn the unit off.
(b) Details of operation
The unit will go into the automatic mode in which it automatically determines, from room temperature (as detected by
sensor), whether to go into the cooling, thermal dry or heating modes.
Function
Room temperature Flap
Operation mode
setting
Fan speed
(SKM, STM only)
Timer switch
Cooling About 25ºC
Thermal dry About 25ºC Auto Auto Continuous
Heating About 26ºC
Unit ON/OFF button
Unit ON/OFF button
Unit ON/OFF button
¡ SKM model
¡ STM model
(3) Drain motor forced operation functions (STM, SRRM only)
(a) Operation
When the float switch detects drain water, please use the wireless remote control to set the operation mode to "heating",
set the temperature to 30°C, and set the timer to continuous operation.
When the float switch detects drain water, press the TEST switch on wired remote control for 3 seconds.
(b) Detail of operation
Sets the decision speed to 0 rps, stops the indoor fan motor, and only lets the drain motor run for 5 minutes. After this
operation finishes, if the float switch detects drain water, it will display an error and stop operation.
(C) Reset condition
(i) When the drain motor has run for 5 minutes.
(ii) Use the remote control to set the operation mode to heating, set the temperature to 30°C, and set the timer to something
other than continuous operation.
¡ SRRM model
25
(4) Power blackout auto restart function
(a) Power blackout auto restart function is that records the operational status of the air-conditioner immediately prior to it being
switched off by a power cut, and then automatically resumes operations at that point after the power has been restored.
(b) The following settings will be cancelled:
(i) Timer settings
(ii) High-power operations
Notes (1) Power blackout auto restart function is set at on when the air-conditioner is shipped from the factory. Consult with your dealer if this function needs to
be switched off.
(2) When power failure ocurrs, the timer setting is cancelled. Once power is resumed, reset the timer.
(3) If the jumper wire (J7) “REMOTE/AUTORESTART (SKM), AUTORESTART (STM, SRRM) ” is cut, auto restart is disabled. (See the diagram at
above)
¡ SKM model
(5) Flap control (SKM, STM only)
Control the flap by AIRFLOW button on the wireless remote control.
(a) Air scroll
The flap will be automatically set to the angle of air flow best to operation.
(i) Starting time of operation
(ii) When not operating
The flap closes, when operation has stopped.
s
During cooling and
t
dry operation
Thick line : Rapid movement
Thin line : Slow movement
Stops for approximately 5 seconds in the horizontal position.
s
During heating
t
operation
Stops for approximately 5 seconds in this position.
Thick line : Rapid movement
Thin line : Slow movement
¡ STM, SRRM model
¡ SKM model
¡ STM model
Thick line : moves quickly
Thin line : moves slowly
Stops at this position for 5 seconds.
Thick line : moves quickly
Thin line : moves slowly
Stops at this position for 5 seconds.
s
During cooling and
t
dry operation
s
During heating
t
operation
EXTERNAL INPUT
WIRED REMOCON
OPE PERMISSION CUSTOM
AUTO RESTART
LO TEMP
DIRT PREVENT
COOL ONLY
HI CEIL PANEL
50/60