(3) Operation data
¡ The combinations of the indoor units is indicated by numbers. They are read as follows.
(Example) SKM22ZD-S / 22 SKM35ZD-S / 35
¡ The capacity of the indoor units is shown by rooms. If this exceeds the maximum capacity of the outdoor unit, the demand
capacity will be proportionally distributed.
¡ If units are to be combined, use the table below to make the proper selection.
Model SCM60ZD-S
(a) Heating
1
room
22 3.2 - - 0.75 3.2 3.4 320 1100 1200 5.1 4.8 4.6
25 3.4 - - 0.75 3.4 3.6 320 1200 1300 5.5 5.3 5.1
28 4.0 - - 0.75 4.0 4.2 320 1450 1550 6.7 6.4 6.1
35 4.5 - - 0.75 4.5 4.6 320 1750 1800 8.0 7.7 7.4
50 5.8 - - 0.75 5.8 6.2 320 2100 2400 9.6 9.2 8.8
11.9
10.3
11.4
10.1
10.9
60 6.8 - - 0.75 6.8 6.9 320 2600 2650
2
room
22+22 2.55 2.55 - 1.1 5.1 6.5 330 1450 2350 6.7 6.4 6.1
22+25 2.48 2.82 - 1.1 5.3 6.5 330 1500 2350 6.9 6.6 6.3
22+28 2.55 3.25 - 1.1 5.8 6.5 330 1700 2400 7.8 7.5 7.2
22+35 2.35 3.75 - 1.1 6.1 6.6 330 1900 2500 8.7 8.3 8.0
22+50 2.02 4.58 - 1.2 6.6 6.8 360 2150 2700 9.9 9.4 9.0
9.9 9.5
10.6 9.7
22+60 1.80 4.90 - 1.2 6.7 6.8 360 2250 2700
25+25 2.75 2.75 - 1.1 5.5 6.5 330 1600 2350 7.3 7.0 6.7
25+28 2.78 3.12 - 1.1 5.9 6.5 330 1800 2400 8.3 7.9 7.6
25+35 2.63 3.68 - 1.1 6.3 6.6 330 2000 2500 9.2 8.8 8.4
25+50 2.23 4.47 - 1.2 6.7 6.8 360 2250 2700 10.3 9.9 9.5
25+60 1.97 4.73 - 1.2 6.7 6.8 360 2300 2700
28+28 3.20 3.20 - 1.1 6.4 6.6 330 2050 2450 9.4 9.0 8.6
28+35 2.98 3.72 - 1.1 6.7 6.7 330 2200 2550 10.1 9.7 9.3
28+50 2.41 4.29 - 1.2 6.7 6.8 360 2400 2700 11.0 10.5 10.1
11.2 10.8 10.3
28+60 2.13 4.57 - 1.2 6.7 6.8 360 2450 2700
35+35 3.35 3.35 - 1.1 6.7 6.7 330 2350 2600 10.8 10.3 9.9
35+50 2.76 3.94 - 1.2 6.7 6.8 360 2550 2700 11.7 11.2 10.7
11.9 11.4 10.9
35+60 2.47 4.23 - 1.2 6.7 6.8 360 2600 2700
50+50 3.35 3.35 - 1.5 6.7 6.8 420 2600 2700 11.9 11.4 10.9
12.2 11.6 11.2
50+60 3.05 3.65 - 1.5 6.7 6.8 420 2650 2700
3
room
22+22+22
2.23 2.23 2.23 1.7 6.7 7.2 440 1650 2700 7.6 7.2 6.9
22+22+25
2.20 2.20 2.50 1.7 6.9 7.2 440 1750 2700 8.0 7.7 7.4
22+22+28
2.14 2.14 2.72 1.7 7.0 7.2 440 1800 2700 8.3 7.9 7.6
22+22+35
1.95 1.95 3.10 1.7 7.0 7.2 440 1850 2700 8.5 8.1 7.8
22+22+50
1.64 1.64 3.72 1.9 7.0 7.2 500 1740 2700 8.0 7.6 7.3
9.0 8.6 8.2
22+22+60
1.50 1.50 4.10 1.9 7.1 7.2 500 1950 2700
22+25+25
2.14 2.43 2.43 1.7 7.0 7.2 440 1750 2700 8.0 7.7 7.4
22+25+28
2.05 2.33 2.61 1.7 7.0 7.2 440 1850 2700 8.5 8.1 7.8
22+25+35
1.88 2.13 2.99 1.7 7.0 7.2 440 1950 2700 9.0 8.6 8.2
22+25+50
1.61 1.83 3.66 1.9 7.1 7.2 500 2050 2700 9.4 9.0 8.6
9.4 9.0 8.6
22+25+60
1.46 1.66 3.98 1.9 7.1 7.2 500 2050 2700
22+28+28
1.97 2.51 2.51 1.7 7.0 7.2 440 1950 2700 9.0 8.6 8.2
22+28+35
1.84 2.34 2.92 1.7 7.1 7.2 440 2050 2700 9.4 9.0 8.6
22+28+50
1.56 1.99 3.55 1.9 7.1 7.2 500 2100 2700 9.6 9.2 8.8
9.6 9.2 8.8
22+28+60
1.42 1.81 3.87 1.9 7.1 7.2 500 2100 2700
22+35+35
1.70 2.70 2.70 1.7 7.1 7.2 440 2150 2700 9.9 9.4 9.0
10.1 9.7 9.3
22+35+50
1.46 2.32 3.32 1.9 7.1 7.2 500 2200 2700
25+25+25
2.33 2.33 2.33 1.7 7.0 7.2 440 1800 2700 8.3 7.9 7.6
25+25+28
2.24 2.24 2.51 1.7 7.0 7.2 440 1900 2700 8.7 8.3 8.0
Indoor unit
combinaton
Cooling capacity (kW)
Power cosumption (W) Standard current (kW)
Roomcooling capacity (kW) Total capacity (kW)
Min. Standard Max. 220V 230V 240V
B room C room
Min. Standard Max.
A room