Elektromaten TS 980 Operating Instructions Manual

en
Electrical operating instructions
Door control panel TS 980
(Design and functions subject to change)
51171150 -
b 07.2007
OPERATING AND INSTALLATION INSTRUCTIONS
SAFETY DIRECTIONS .................................................................................................4
ENCLOSURE INSTALLATION....................................................................................6
MAINS SUPPLY ........................................................................................................... 7
SAFETY DEVICES .......................................................................................................8
Safety edge system with optional connection for shutter pass-door or slack-wire switch. .8
SAFETY DEVICES .......................................................................................................9
Resistance evaluation 8K2 with normally open safety edge contact ................................9
Resistance evaluation 1K2 with normally open safety edge contact ................................9
Resistance evaluation 1K2 with normally closed safety edge contact ..............................10
Resistance evaluation 8K2 with normally closed safety edge contact ..............................11
Optical safety edge (Fraba Type) ................................................................................... 11
Safety against entrapment .............................................................................................. 12
Slack-wire Switch ........................................................................................................... 12
Emergency Stop ............................................................................................................12
Photo-beam ...................................................................................................................13
PUSH BUTTON ............................................................................................................14
Three push button station ............................................................................................... 14
Intermediate stop mode ................................................................................................. 15
Ceiling pull switch ........................................................................................................... 15
RELAY CONTACT ........................................................................................................ 16
PCB PRINT OVERVIEW .............................................................................................. 17
INITIALISATION ............................................................................................................18
Initial installation ............................................................................................................. 18
Language selection ........................................................................................................19
page 2
PAGE
ADJUSTMENT OF THE LIMITS/ BASIC-FUNCTION .................................................. 20
Adjust the mechanical limits NES ...................................................................................20
When control has recognised DES digital limits, adjust limit DES ...................................22
Fine adjustment .............................................................................................................. 23
Safety devices ............................................................................................................... 24
Intermediate stop ...........................................................................................................26
Selecting Aux. Function mode ........................................................................................ 27
Adjusting the automatic close feature .............................................................................27
ADJUSTMENT: AUXILIARY FUNCTIONS .................................................................. 27
Adjustment relay contact 1, pre-information mechanical limit NES operation ..................28
Adjustment relay contact 2 .............................................................................................30
Adjustment of pre-limit ....................................................................................................31
Adjustment: Auxiliary Functions ..................................................................................... 32
Automatic ground adjustment .........................................................................................32
Overrun correction should be selected only for rapid doors. ............................................33
Final program ................................................................................................................ 33
REQUEST INFO MODE ............................................................................................... 34
INSTALLATION PLAN..................................................................................................35
CONFIGURATION PLAN FOR LIMIT SWITCHES ....................................................... 36
FAULT REPORT .......................................................................................................... 37
TECHNICAL DATA ....................................................................................................... 38
page 3
SAFETY DIRECTIONS
Basic Directions
This control has been built in accordance with DIN EN 12453 Industrial, commercial and garage doors and gates - Safety in use of power operated doors - Requirements; DIN EN 12978 Industrial, commercial and garage doors and gates - Safety devices for power operated doors - Requirements and Test methods - and left the factory in perfect condition from the point
of view of safety. To maintain this condition and to ensure safe operation, the user must observe all the directions and warnings contained in these operating instructions. In principle, only trained electrical craftsmen should work on electrical equipment. They must assess the work which has been assigned to them, identify potential danger sources and take suitable safety precautions. Reconstruction of or changes of this control Panel TS 980 is only permissible with the approval of the manufacturer. Original replacement parts and accessories authorised by the manufacturer guarantee safety. Liability ceases to apply if other parts are used.
The operational safety of this control Panel TS 980 is only guaranteed if it is used in accordance with the regulations. The limiting values stated in the technical data should not be exceeded under any circumstances (see corresponding sections of the operating instructions).
Safety Regulations
During the installation, initial operation, maintenance and testing of the ELEKTROMATEN, it is necessary to observe the safety and accident-prevention regulations valid for the specific application.
In particular, you should observe the following regulations (this list is not exhaustive):
European normativ
- DIN EN 12453 Saftey in use of power operated doors - Requirements
- DIN EN 12445 Saftey in use of power operated doors - Test methods
- DIN EN 12978 Industrial, commercial and garage doors and gates ­Safety devices for power operated doors - Requirements and Test methods
Please check normative´s bellow.
VDE-regulations
- DIN EN 418 Safety machinery Emergency stop equipment functional aspects Principles for design
- DIN EN 60204-1 / VDE 0113-1 Safety of machinery - Electrical equipment of machines - Part 1: Prescriptions générales
- DIN EN 60335-1 / VDE 0700-1 Safety of household and similar electrical appliances - Part 1: General requirements
Regulations
- Please ensure that the local regulations relating to the Safety of Opera­tions of Doors are followed
page 4
SAFETY DIRECTIONS
Explanation of warnings
These operating instructions contain directions which are important for using the ELEKTROMATEN appropriately and safely.
The individual directions have the following meaning:
DANGER
This indicates danger to the life and health of the user if the appropriate precautions are not taken.
CAUTION
This warns that the ELEKTROMATEN or other materials may be damaged if the appropriate precautions are not taken.
General warnings and safety precautions
The following warnings are to be understood as a general guideline for working with the ELEKTROMATEN in conjunction with other devices. These directions must be observed strictly during installation and operation.
Please observe the safety and accident prevention regulations valid for the specific application.
The ELEKTROMATEN must be installed with the authorised coverings and protective devices. Care should be taken that any seals are fitted correctly and screw couplings are tightened correctly.
In the case of ELEKTROMATEN with a permanent mains connection, an all­pole main switch with appropriate back-up fuse must be provided.
Check live cables and conductors regularly for insulation faults or breakages. When a fault is detected in the cabling, the defective cabling should be replaced after immediately switching off the mains supply.
Before starting operation, check whether the permissible mains voltage range of the devices corresponds to the local mains voltage.
With three – phase motor connection it must have right phase rotation
page 5
ENCLOSURE INSTALLATION
Before mounting the enclosure the surface has to be checked for flatness, slope and freedom from vibrations. For installation we recommend to use the template supplied. Mounting must be vertical. Mounting, see drawing.
page 6
MAINS SUPPLY
The TS 980 control can be used with all GfA ELEKTROMATEN up to 2,2KW
Warning! This indicates danger to the life through electric shock.
Before starting assembly, disconnect the equipment from the electricity supply.
The control panel TS 980 works with the following supplies. ( See diagrams) Fig.1 to Fig.4 mains supply
3 x 400V, N, PE
Fig. 1 Mains supply 3x 400V,N,PE
3 x 400V, PE
Fig. 2 Mains supply 3x 400V,PE
3 x 230V, PE
Fig. 3 Mains supply 3x 230V,PE
1 x 230V, N, PE
Fig. 4 Mains supply 1x 230V,N,PE
page 7
SAFETY DEVICES
Safety edge system with optional connection for shutter pass-door or slack-wire switch.
The control recognises and works with 5 different safety edges. Each one needs a special 4 core spiral cable and includes an optional shutter pass-door or slack-wire switch contact. The spiral cable connection must be made on the print with the plug provided. The other end is connected to a terminal box or a signal emitter, such as a pressure switch.
- Resistance evaluation 8K2 with normally open safety edge contact (page 9)
- Resistance evaluation 1K2 with normally open safety edge contact (page 9)
- Resistance evaluation 1K2 with normally closed safety edge contact (page 10)
(pressure switch with "Pressure Wave Testing")
- Resistance evaluation 8K2 with normally closed safety edge contact (page 11)
- Optical safety edge system (Fraba type) (page 11)
Important note!
When connecting a safety edge, make sure of compliance with DIN EN 12978 Industrial, commercial and garage doors and gates - Safety devices for power operated doors - Requirements and Test methods.
Mounting the spiral cable
A bush is provided on both sides of the control box for mounting the spiral cable. Push the blue plugs through into the enclosure until there is sufficient cable to allow them to be connected to the board. The plug with two cores must be connected to the pass-door and slack-wire switch terminals. The three core plug must be connected to the safety edge terminals. The control panel TS 980 recognises automatically the type of safety edge used.
Please check after installation all terminal screws are tight to ensure they are finger safe.
page 8
SAFETY DEVICES
Resistance evaluation 8K2 with normally open safety edge contact
This evaluation system is made for electrical safety edges within an end-of-line resistor of 8K2. The resistor must be connected in series with the switch in the safety edge. If a pass-door or slack-wire switch is to be connected, remove the bridge at terminals ST and ST+ in the terminal box
pass-door/slack­wire switch contact
end-of-line resistor 8K2
fig. 1 wiring diagram electrical safety edge with 8K2 resistor and normally open contact
Resistance evaluation 1K2 with normally open safety edge contact
This evaluation system is made for electrical safety edges within an end-of-line resistor of 1K2. The resistor must be connected in series with the switch in the safety edge. If a pass-door or slack-wire switch is to be connected, remove the bridge at terminals ST and ST+ in the terminal box.
pass-door/slack­wire switch contact
end-of-line resistor 1K2
fig. 2 wiring diagram electrical safety edge with 1K2 resistor and normally open contact
page 9
SAFETY DEVICES
Resistance evaluation 1K2 with normally closed safety edge contact
This evaluation system is made for pressure-wave switches ( N/C ) with an end-of-line resistor of 1K2. A pressure wave is generated by compressing the rubber profile, which is conducted to the pressure-wave switch through the plastic hose. The system should be tested as the door closes. The limit S5 must be set to activate the "Testing function" (when using mechanical limit switches). For adjusting the testing function, close the shutter and stop it max. 5 cm before the closed position, now set limit S5. When the shutter runs over the limit S 5, a timer of two seconds starts to countdown.
If a pressure wave activates the pressure switch in this time the TS 980 recognises the function of the safety edge. If the pressure switch has not been activated, the control goes into fault mode and the system will only work in DEAD MAN mode in the close direction. If pass-door or slack-wire switch contact is to be connected, remove the bridge at terminal ST and ST+ in the terminal box.
Important note!
When setting the closed position the rubber edge has to send out a pressure wave sufficient to operate the pressure switch.
Important note!
When using a safety edge system the limit S5 must be set when using mechanical limits. Close the shutter and stop 5 cm before the end position, now set limit S5.
pass-door/slack­wire switch contact
end-of-line resistor 1K2
Fig.3: Wiring diagram resistance evaluation 1K2 normally closed contact
(pressure - wave switch)
page 10
SAFETY DEVICES
Resistance evaluation 8K2 with normally closed safety edge contact
This evaluation system is made for safety edges within an end-of-line resistor of 8K2. When a normally closed safety edge system which works in quiescent current mode is connected, a separate safety edge control has to be connected. The resistor must be connected in series with the switch in the safety edge. If pass- door or slack-wire switch is to be connected, remove bridge at terminals ST and ST+ in the terminal box.
pass-door/slack­wire switch contact
end-of-line resistor 8K2
fig. 4 wiring diagram electrical safety edge with 8K2 resistor and normally open contact
To monitor the end of line safety edge system correctly, the resistor should be mounted close to the switching unit. l. e. pressure switch.
Optical safety edge (Fraba Type)
The principle of operation is similar to a through-beam light barrier with self testing. By activating the safety edge, the light beam is interrupted. If a pass-door or slack-wire switch is to be connected, remove the bridge at terminals ST and ST+ in the terminal box.
pass-door/slack­wire switch contact
Transmitter
The fig. 5 wiring diagram optical safety edge system (Fraba type)
page 11
Receiver
SAFETY DEVICES
Safety against entrapment
This is an additional safety system ( e.g. self-testing light barrier) which shall prevent trapping a person or obstacle in the door. In accordance with EN 12453 monitoring is required of each door or shutter where lifting of people or obstacles cannot be prevented (e.g. Grilles).
A separate control system within an end­of-line resistor of 1K2 should be connected. TS 980 recognises various faults - short circuit, contact or supply interruption. This safety system is only in effect in the upwards direction. When recognising a contact the door movement upwards Stops and returns downwards for only 2 sec.. Then the door Stops until a new command is received. At the same time the control-display displays Emergency Stop Entrapment.
end-of-line resistor 1K2
monitoring resistor
Fig. 1: Wiring diagram of indicator with a monitoring
resistor.
Important note
In accordance with EN 954 -1 the safety edge control of the entrapment device has to meet category 2.
Slack-wire Switch
For doors with a cable or chain drive, in accordance DIN EN 12453 slackness must be monitored. The control can be done with a slack-wire switch which can be connected directly on TS 980 terminals SL+/SL the reaction is just STOP.
Emergency Stop
In accordance DIN EN 418 the emergency Stop button has to meet category 0.
Slack-wire
Switch
Fig. 2: Slack-wire switch wiring
EMERGENCY
STOP
Fig. 3: EMERGENCY STOP wiring
page 12