Install the thermostat at a suitable place where its operation cannot be affected by direct fl ow
of hot air from the heater, sunshine or other disturbing effects. Neither install it on an external
wall. The installation height should be approx. 1.5 m above the fl oor. Place the thermostat in
the “reference room”, such as the living room (the heating source will switch according to the
temperature in this room).
The installation must only be done by a properly qualifi ed person!
Before installation, disconnect the power supply!
INSTALLATION PROCEDURE
INSTALLATION AND LOCATION
1) Switch off the main circuit breaker.
2) Loosen the locking screw and remove the front part of the thermostat with the
electronics (Fig. 1).
3) Fix the back part of the thermostat to the wall (Fig. 2).
4) Connect the wires to the terminal board; take heed to proper tightening of the
terminals.
5) Put on the front part of the thermostat with LCD and ensure the thermostat with the
locking screw against splitting.
6) Switch on the main circuit breaker. If everything is OK, the LCD shows the current
temperature.
7) Set the thermostat parameters and the required temperature program according to the
instructions.
PT14-P DESCRIPTION
When heating is
switched on,
LED is lit
RESET button
internal temperature sensor
backlit display
(active for 30 s after
you push any button)
2
entry into the menu (AUTO, MANU,
OFF, CLO, PROG, PAr)
short push = confi rmation (ENTER)
long push = step back
browsing the functions of
temperature setting, time, key
locking; see page 10
Page 3
Fig.1 Loosen the locking screw and remove
the thermostat electronics.
Fig.2 Fix the back part of the thermostat
to the wall.
holes for installation screws
Fig.3 Connect the inlet wires according
to the diagram.
L
N
HEATING-
16 A
max.
UNUSED
Fig.4 Put the electronics part onto the bottom
part and ensure it with the locking screw.
3
Page 4
LCD DESCRIPTION
current day
preset required
temperature
( , , )
heating on
indication
current temperature
required temperature
or current time
or status information
preset mode
FUNCTIONS AND SETTING
Push any button to activate the display backlight. Then push the MENU button to enter
the menu. Browse in the menu with the or button:
AUTO : the thermostat works according to the program preset (page 8, 9).
MANU : used for manual temperature setting (selection with the
the temperature remains constant until the next manual temperature change.
OFF: tin this mode, the thermostat is off permanently
is functional).
(the anti-freeze protection of 3 °C
CLo : current day and time setting.
PROG : mode for temperature program setting.
PAr : parameter settings.
or ), button);
4
Page 5
CURRENT DAY AND TIME SETTING (CLo)
Push twice the MENU button; choose the CLo function with the
button; confi rm with the MENU button. The hour indication
is fl ashing on the display, set the current hour with the
button and confi rm with the MENU button. Similarly, proceed with
the minutes, day and year, confi rm each setting with the MENU
button. Return to the menu by means of long push of the MENU
button.
or
PARAMETER SETTING (PAr)
Push twice the MENU button; chose the PAr function with the
button; confi rm with the MENU button.
Set the parameters as follows:
P1economical temperature (17 °C by default)
- The display shows P1
- Set the required economical temperature with the
button and confi rm it with the MENU button.
or
P2comfortable temperature (23 °C by default)
- The display shows P2
- Set the required comfortable temperature with the
button and confi rm it with the MENU button.
or
P3party temperature (25 °C by default)
- The display shows P3
- Set the required party temperature with the or
button and confi rm it with the MENU button.
5
Page 6
P4hysteresis (0.5 °C by default)
- The display shows P4
- Set the required hysteresis with the
or button (see the
graph) within the range of 0.1 to 6 °C (selection by 0.1 °C)
and confi rm it with the MENU button.
P5minimum switch-on time (1 minute by default)
- The display shows P5
- With the or button, set the minimum time of the
thermostat switch-on in minutes.
Choose it according to the type of the heating system used
within the range of 1 to 5 minutes (see the table) and confi rm
with the confi rm it with the MENU button.
desired
temp..
Heating
ON
6
HYSTERESIS
Heating
type
T
hysteresis
Electric heating
Plate radiators
Cast iron radiators
Floor heating
t
t
Minimum source
switch-on time
1
2 (3)
4
5
Page 7
P6current temperature correction (0 °C by default)
- The display shows P6
- With
or button, set the correction within the range
of -5 °C to +5 °C and confi rm it with the MENU button.
It is used to correct the temperature measured by the thermostat. The setting must be done only
after 12-hour operation, when the internal sensor temperature has stabilized. Measure the room
temperature with a thermometer; if it is different from the thermostat temperature, set the correction.
P7keyboard lock code (not set by default)
- The display shows P7
- With
or button, set a combination of 4 digits (from 0 to 9)
and confi rm it with the MENU button.
The keys will be locked within 1 minute (after entry in the basic display); the
LCD shows the LOC message. If you push a key, the LCD prompts you to
enter the keyboard code; after entering the correct code, you can make any
changes (control elements are functional again).
The control elements are locked again automatically after the
setting is completed (within approx. 1 minute).
RECOMMENDATIONS:
- Record the keyboard code in the table;
- The code can be cancelled with the - - - - option;
- If you lose the code, you must restore the default settings of
the thermostat. Hold
RESET (see page2). Not before the sign rESE will appear
on the LCD screen leave the
button and briefl y press the button
YOUR CODE
buttons.
P8fi rmware version (default settings restoration)
Firmware version, for information only.
FACTORY SETTINGS RESTORATION:
Push long (for approx. 3 s) the
button, the RESE message
appears shortly on the LCD and the default setting of the thermostat
will be restored!
7
Page 8
TEMPERATURE PROGRAM SETTING (PROG)
Push twice the MENU button; select the PROG function with the
button and confi rm it with the MENU button.
CHOOSE A DAY OR BLOCK OF DAYS:
- With the
want to program:
1= Monday5= Friday12345= Monday to Friday
2= Tuesday6= Saturday 67= Saturday to Sunday
3= Wednesday 7= Sunday1234567= all week
4= Thursday
- After selection, push the MENU button.
CHOOSE THE 1ST CHANGE TIME:
- The fi rst time change setting (1) appears on the display; the time
value is fl ashing
- Set the fi rst change time with the or button (minimum step
of 10 min) and confi rm it with the MENU button.
CHOOSE THE REQUIRED TEMPERATURE:
- The
required temperature with the
are preset in the parameters P1, P2 and P3 (see page 5).
- Confi rm with the MENU button again.
- The second time change setting (2) of the same day appears automatically on the
display.
- Repeat this procedure until you set all (up to 6) of the time changes; then exit the
programming mode by long push of the MENU button.
- Choose the AUTO function; the thermostat starts working according to the preset
program.
button, choose a day or block of days which you
TABLE FOR SELECTION OF DAYS TO PROGRAM
, or symbol appears on the display. Choose the
button (the temperature values
8
Page 9
PRESET TEMPERATURE PROGRAM
P1 = 17°C P2 = 23°C P3 = 25°C
program for Mon-Fri
561821023
program for Sat-Sun
721023
SHORT TERM TEMPERATURE CHANGE
In the AUTO mode, push any button, and then the or button
to make a short-term change of the temperature.
The thermostat will keep this temperature until the next
temperature change given by the program.
9
Page 10
OFF FUNCTIONpermanent switch-off
Push twice the MENU button; select the OFF function with the
button and confi rm it with the MENU button.
The thermostat will switch off. The OFF message appears on the
display. To cancel this function, push twice the MENU button and
choose another mode (AUTO or MANU) with the
Note: The anti-freeze mode is still active.
button.
KEY LOCK
It is used to lock the keyboard as a protection against undesirable
operation.
Push the MENU and
locked. The LOC message appears on the display.
To cancel, unlock, you can simultaneously push the MENU and
button.
Note: If the key lock code has been entered (see parameter P7,
page 7), it is necessary to enter the pertinent code!
buttons; in this way, the keyboard will be
ANTI-FREEZE MODE
If the room temperature falls below 3 °C, the thermostat
automatically switches the connected device (heater).
The FrO message appears on the display.
As soon as the temperature rises by 0.5 °C, the thermostat
resumes the preset mode.
AUTOMATIC CHANGE OF SUMMER/WINTER TIME
If the current time is set correctly, the change from the summer to
winter time and vice versa is automatic.
10
Page 11
OVERVIEW OF TYPES MANUFACTURED
PT14PT14
Thermostat with a backlit display, suitable for direct heaters,
fl oor heating and electric heating panels.
Advantages:
quick selection of economical and comfortable •
temperature
simple operation•
output relay max. 16 A•
power supply 230 VAC•
fi xed hysteresis 0.5 °C•
PT14-HTPT14-HT
Thermostat with a backlit display, suitable for control of
thermoelectric drives (NC = closed in de-energized state).
A semiconductor providing for noise-free operation is used
as the switching element.
Advantages:
quick selection of economical •
and comfortable temperature
simple operation•
up to 2 thermoelectric drives •
can be connected to the outlet
power supply 230 VAC•
stepless control•
zóna 1
zóna 2
zóna 3
zóna 4
zóna 5
zóna 6
11
Page 12
PROGRAMMABLE THERMOSTAT PT14-PPT14-P
Suitable for households, family houses and offi ces with electric heating. It can be
used for switching of direct heaters, electric radiant panels or electric fl oor heating
up to the current of 16 A. The well-arranged backlit display enables reading and
setting even at low intensity of the ambient lighting.
Technical parameters
Power supply230 V/ 50 Hz
Power consumption1 VA (1W)
Hysteresis - adjustable0.1°C to 6°C
Number of temper. changes 6 temper. changes per every day
Minimum programming time 10 minutes
Adjustable temper. range+3°C to 39°C
Temperature settingsby 0.5°C
Minimum indication step0.5°C
Measuring accuracy± 1°C
Switching elementrelay
ProtectionIP20
Protection classII
Outputmax. 16 A
Operating temperature0°C to +40°C
CERTIFICATE OF GUARANTEE