1. Unpacking
Thank you for choosing the Elektralite ML602 moving light fixture.. For your own safety, please read
this manual before installing the fixture. This manual covers important information on installation and
applications. Please keep this manual for future reference.
To keep this simple, we are going to refer to the fixture as the Elektralite ML602 throughout the manual. The Elektralite ML602 uses a high powered 90 watt led which is run a balanced and conservative arrangement at 60 watts. Please unpack the Elektralite ML602 carefully and check whether it was
damaged in shipping. Turn the head both horizontally (Pan) and vertically (tilt) to make sure all movement
is smooth.
The following items should be in the box with the fixture:-
Safety cable
U brackets
DMX 5 pin male to 5 pin female cable
4 spare gobos
2. Safety Instructions.
This device has left the factory in perfect condition. In order to maintain this condition and to ensure a
safe operation, it is absolutely necessary for the user to follow the safety instructions and warning notes
written in this user manual. The Elektralite ML602 is a high voltage fixture. Be careful when dealing with
high voltages.
Please read this manual. If you do not read this manual and damages occur to the Elektralite ML602, then it could void the warranty.
During shipping, Elektralite ML602 may have been exposed to high temperature or humidity changes. So, as a precaution, do not switch Elektralite ML602 on immediately. Condensation can damage Elektralite ML602 so leave it switched off, until it has reached room temperature. The electrical connection must be carry out by a qualified person and it is absolutely essential that the
Elektralite ML602 be grounded. This is imperative and is a safety issue. Do not break or bend out of the
way, the ground center pin on the plug.
Always disconnect the Elektralite ML602 from the power source, when the device is not in use or before cleaning it. Only unplug Elektralite ML602 from the power cord. Never pull out the plug out by pulling on
the power cord.
Please keep the Elektralite ML602 away from children and the general public. Please be intelligent and use common sense when operating the Elektralite ML602.
3. General Guidelines.
The Elektralite ML602 is a lighting fixture for professional use on stages, in churches, theatres, etc. The Elektralite ML602 should only be operated at between 120 to 240 volts and only indoors. By 240
volts we mean that the neutral must remain a neutral and NOT be used as one phase in a 120v circuit to
create 208 volts across the Elektralite ML602. The reason for this is simple, the neutral is not protected with a fuse. Any problem with that phase will not be protected by the Elektralite ML602. The Elektralite ML602 should not be operated 24/7 (24 hours a day; 7 days a week). The Elektralite ML602 needs operation breaks to ensure that it will work for a long time without problems. Please do not shake Elektralite ML602 and avoid using brute force when installing or operating it. When choosing the location to install the Elektralite ML602, please make sure that it is not exposed to extreme heat, moisture or dust. The minimum distance between the Elektralite ML602 and the
illuminated surface must be more than 3 feet.
Always mount the Elektralite ML602 with an appropriate safety cable/chain. Operate the Elektralite ML602 only when you are familiar with the features on the fixture. Do not permit
operation by persons not qualified to operate it.
All modifications to the Elektralite ML602 will invalidate the warranty. There are absolutely no exceptions. That includes operation of the fixture at 208v using two different 120v phases. If Elektralite ML602 is operated in any way different to the one described in this manual, the Elektralite
ML602 maybe damaged and the guarantee will be void.
4. Installation
Please ensure that the Elektralite ML602 is hung using the appropriate "C" clamps or half cheeseboros and the U brackets that come with the Elektralite ML602. A safety chain or cable should also be used as a secondary point of holding the fixture in case the clamp comes loose. Never hang the fixture without
a safety chain or cable.
Mount the Elektralite ML602 either vertically upright or vertically down. DO not mount the Elektralite ML602 sideways.
If you are not qualified or have any doubts about hanging the Elektralite ML602 then do NOT hang it.
Do not clamp the cable to the U bracket or clamp. That is not a secondary safety point.
A secondary safety point is any point that will adequately hold the Elektralite ML602 if the "U" brackets, "C" clamps or half cheese-boros fail. Then the safety cable would be the backup and stop the Elektralite ML602 from falling to the ground. So do NOT fix the safety to the same place that the "C"clamps/half