elektraLite eyeBall QUAD User Manual

Elektralite eyeBall Quad led
USER MANUAL
Elektralite (a division of Group One), 70, Sea Lane, Farmingdale, NY11735, U.S.A. T. +1 (516)-249-3662. F. +1 (516)-249-8870
1. Unpacking
Thank you for choosing the Elektralite eyeBall fixture. For your own safety, please read this manual
before installing the device. This manual covers important information on installation and applications.
Please keep this manual for future reference.
Elektralite eyeBall wash fixture uses 7 high powered 10 watt quad leds in a balanced arrangement giving incredible output. Please unpack the Elektralite eyeBall carefully and check whether it was
damaged in shipping.
The following item should be in the box with the fixture:-
2 part yoke
2 knobs for yoke
1 DMX 5 pin cable
1 Turnaround 3 to 5 pin cable
1 Turnaround 5 to 3 pin cable
1 IEC power cable
1 IEC jumper cable (for joining fixtures)
2. Safety Instructions.
This device has left the factory in perfect condition. In order to maintain this condition and to ensure a
safe operation, it is absolutely necessary for the user to follow the safety instructions and warning
notes written in this user manual. Elektralite eyeBall is a high voltage fixture. Be careful when dealing
with high voltages.
Please read this manual. If you do not read this manual and damages occur to the Elektralite eyeBall, then it could void the warranty.
During shipping, the Elektralite eyeBall may have been exposed to high temperature changes or humidity changes. So, as a precaution, do not switch the Elektralite eyeBall on immediately. Condensation can damage the Elektralite eyeBall so leave the Elektralite eyeBall switched off until it has reached room temperature. The Elektralite eyeBall is an INDOOR operational fixture. Do not operate this fixture outdoors or anywhere there is high humidity. The electrical connection must carry out by a qualified person and it is absolutely essential that the Elektralite eyeBall be grounded. So under no circumstances break off the ground pin on the Edison plug or use the fixture where a ground is not present. A ground pin, like the fuse for the Elektralite eyeBall is there for safety.
Always disconnect the Elektralite eyeBall from the power source, when the fixture is not in use or before cleaning it. Only unplug Elektralite eyeBall from the power source holding onto the Edison plug.
Never pull out the Edison plug out by just pulling on the power cord itself.
Please keep the Elektralite eyeBall away from children and the general public. Please be intelligent and use common sense when operating the Elektralite eyeBall.
3. General Guidelines.
Elektralite eyeBall is a lighting fixture for professional use on stages, in clubs, theatres, churches etc. Elektralite eyeBall should only be operated at between 120 to 240 volts and only indoors. Elektralite eyeBall should not be operated 24/7 (24 hours a day; 7 days a week). Elektralite eyeBall
needs operation breaks to ensure that it will work for a long time without problems. Please do not
shake the Elektralite eyeBall and avoid using brute force when installing or operating it. When choosing the location to install the Elektralite eyeBall, please make sure that it is not exposed
to extreme heat, moisture or dust and never install it outdoors. Make sure that the fixture has a good
amount of free space around it for air flow. Do not install it in a confined space or have insulation
around the fixture. The minimum distance between the Elektralite eyeBall and the illuminated surface
must be more than 3 feet.
Always mount the Elektralite eyeBall with an appropriate safety cable. Operate the Elektralite e yeBall only when you are familiar with the features on the fixture. Do not
permit operation by persons not qualified.
All modifications to the Elektralite eyeBall will invalidate the warranty. There are absolutely no exceptions. If the Elektrali te eyeBall is operated in any way different to the one described in this manual, the
Elektralite eyeBall maybe damaged and the guarantee will be void.
4. Installation
Please ensure that the Elektralite eyeBall is hung using the appropriate "C" clamp or half cheeseboro.
A safety chain or cable should also be used as a secondary point of holding the fixture in case the
clamp comes loose. Never hang the fixture without a safety chain or cable.
If you are not qualified or have any doubts about hanging the Elektralite eyeBall then do NOT hang it.
Do not clamp the safety cable to the U bracket or clamp. That is not a secondary safety point.
A secondary safety point is any point that will adequately hold the Elektralite eyeBall if the "C" clamp
or half cheesboro fails. Then the safety cable would be the backup and stop the fixture from falling to
the ground. So do NOT fix the safety cable to the same place that the "C"clamp is attached.
5. DMX-512 Control Connection
Ω
Connect an XLR cable to the female 5-pin XLR output of your Elektralite CP 20 or other DMX controller. The other end should be connected to the male 5-pin XLR input of the Elektralite eyeBall. Then daisy-chain out of the first Elektralite eyeBall into the next Elektralite eyeBall or other dmx device. Never “Y” split the DMX connection.
If you need more cable, then it should be two core, screened cable fitted with a 5 pin XLR input and
output connector. Please refer to the diagram below.
1
5
4
2
3
DMX-512 connection with DMX terminator
For installations where the DMX cable has to run a long distance or is in an electrically “noisy”
environment, it is recommended that a DMX terminator is used. This helps prevent corruption of the
digital control signal. The DMX terminator is simply a 5 pin XLR plug (male) with a 120 resistor
connected between pins 2 and 3. It is then plugged into the output XLR socket of the last Elektralite eyeBall or other dmx device in the chain. Please see illustration below.
5
4
1
2
3
120
6. Menus in the fixture.
Root Menu Sub Menu 1 Sub Menu 2
STAT (STATIC LOOK) RED 0-255
GREEN 0-255
BLUE 0-255
WHITE 0-255
STROBE 0-255
AUTO (AUTOMATIC) Red
Green
Blue
Yel l o w
Cyan
Purple
White
Effect #1
Effect #2
Effect #3
RUN DMX 512
SLAVE
ADDRESS ASSIGN DMX CHANNEL 1-512
ID address 1-255
PERSONALITY STAG(E)
ARC.1
ARC1.D
ARC2
AR2.D
AR2.S
HSV
SETTINGS DTV NTSC/PAL
RGB
DIMMER 000(OFF), 001, 002, 003 or 004
RESET Password required*
FAN OFF
AUTO
LOW
NORMAL
HIGH
OFF
KEY LOCK OFF **SEE BELOW
ON
White
ON/OFF ***
*The Password for the reset is using the up and down buttons when in the reset menu. The screen will initially
display [ ]. The following needs to be pressed ↑↓↑↓↑↓ then press Enter. The screen will then display the
word "OK" for 2 seconds and the fixture will reset.
**The Pasword for Key Lock is the same as reset. If key lock is ON then everytime you power up the eye Ball the
Password is requested. The password must be put in the eye Ball display otherwise no changes can be made to
the operation of the eye Ball.
***RGBWhite. If this feature is turned on the Output of the RGB and white can be adjusted for maximum output.
Normally the R, G, B, and W all default to maximum of 255 output. However this can be change for each of the
color components from a value of 128 up to 255.
Loading...
+ 9 hidden pages