1. Unpacking
Thank you for choosing the Elektralite Theatrical White Dazer fixture. For your own safety, please read this manual
before installing the fixture. This manual covers important information on installation and applications. Please keep this
manual for future reference.
The Elektralite Theatrical Dazer fixture uses 36 high powered 5 watt leds in a balanced arrangement giving incredible
output. Please unpack it carefully and check whether it was damaged in shipping.
The following items should be in the box with the fixture:-
Color/Gel frame
Safety Cable
2. Safety Instructions.
This device has left the factory in perfect condition. In order to maintain this condition and to ensure a safe operation, it
is absolutely necessary for the user to follow the safety instructions and warning notes written in this user manual. The
Elektralite Theatrical White Dazer is a high voltage fixture. Be careful when dealing with high voltages. Please read this manual. If you do not read this manual and damages occur to the Elektralite Theatrical White Dazer, then it could void the warranty.
During shipping, Elektralite Theatrical White Dazer may have been exposed to high temperature changes or humidity changes. So, as a precaution, do not switch Elektralite Theatrical White D azer on immediately. Condensation can damage Elektralite Theatrical White Dazer so leave it switched off, until it has reached room temperature. The electric connection must be carry out by a qualified person and it is absolutely essential that the Elektralite
Theatrical White Dazer be grounded. This is imperative and is a safety issue. Do not break or bend out of the way,
the ground center pin on the plug.
Always disconnect the Elektralite Theatrical Wh ite Dazer from the power source, when the device is not in use or before cleaning it. Only unplug Elektralite Theatrical White Dazer from the power cord. Never pull out the plug out by
pulling on the power cord.
Please keep the Elektralite Theatrical White Dazer away from children and the general public. Please be intelligent and use common sense when operating the Elektralite Theatrical White Dazer.
3. General Guidelines.
The Elektralite Theatrical White Dazer is a lighting fixture for professional use on stages, in churches, theatres, etc. The Elektralite Theatrical White Dazer should only be operated at between 120 to 240 volts and only indoors. The Elektralite Theatrical White Dazer should not be operated 24/7 (24 hours a day; 7 days a week). The Elektralite Theatrical White Dazer needs operation breaks to ensure that it will work for a long time without problems. Please do not shake the Elektralite Theatrical White Dazer and avoid using brute force when installing or operating it. When choosing the location to install the Elektralite Theatrical White Dazer, please make sure that it is not exposed to extreme heat, moisture or dust. The minimum distance between the Elektralite Th eatrical White Dazer and the
illuminated surface must be more than 3 feet.
Always mount the Elektralite Theatrical White Dazer with an appropriate safety cable/chain. Operate the Elektralite Theatrical White Dazer only when you are familiar with the features on the fixture. Do not
permit operation by persons not qualified to operate it.
All modifications to the Elektralite Theatrical White Dazer will invalidate the warranty. Ther e are absolutely no exceptions. If Elektralit e Theatrical White Dazer is operated in any way different to the one described in this manual, the
Elektralite Theatrical White Dazer maybe damaged and the guarantee will be void.
4. Installation
Please ensure that the Elektralite Theatrical White Dazer is hung using the appropriate "C" clamp or half cheeseboro.
A safety chain or cable should also be used as a secondary point of holding the fixture in case the clamp comes loose.
Never hang the fixture without a safety chain or cable. Make sure the Gel frame (Gel holder) is clipped into position
correctly and cannot come loose.
If you are not qualified or have any doubts about hanging the Elektralite Theatrical White Dazer then do NOT hang it.
Do not clamp the cable to the U bracket or clamp. That is not a secondary safety point.
A secondary safety point is any point that will adequately hold the Elektralite Theatrical White Dazer if the "C" clamp
or half cheesboro fails. Then the safety cable would be the backup and stop the fixture from falling to the ground. So do
NOT fix the safety to the same place that the "C"clamp is attached.
5. DMX-512 Control Connection
Ω
Connect the provided XLR cable to the female 5-pin XLR output of the Elektralite CP 16/24 or other DMX controller. The other end should be connected to the male 5-pin XLR input of the Elektralite Theatrical White Dazer . Then daisy-chain out of the first Elektralite Theatrical White Dazer and into the next Elektralite Theatrical White Dazer or other dmx device. Never “Y” split the DMX connection.
If you need more cable, then it should be two core, screened cable fitted with a 5 pin XLR input and output connector.
Please refer to the diagram below.
1
5
4
2
3
DMX-512 connection with DMX terminator
For installations where the DMX cable has to run a long distance or is in an electrically “noisy” environment, it is
recommended that a DMX terminator is used. This helps prevent corruption of the digital control signal. The DMX
terminator is simply a 5 pin XLR plug (male) with a 120 resistor connected between pins 2 and 3. It is then plugged
into the output XLR socket of the last Elektralite Theatrical White Dazer or other dmx device in the chain. Please see