Elektralite (a division of Group One),
70, Sea Lane, Farmingdale, NY11735, U.S.A.
T. +1 (516)-249-3662. F. +1 (516)-249-8870
WWW.MYELEKTRALITE.COM
1. Unpacking
Thank you for choosing the Elektralite 1018RGBWA (5-in-1) fixture. For your own safety, please read
this manual before installing the device. This manual covers important information on installation and
applications. Please keep this manual for future reference.
Elektralite 1018 (5-in-1) wash fixture uses 18 high powered 10 watt quad leds in a balanced
arrangement giving incredible output. Please unpack the Elektralite 1018 (5-in-1) carefully and check
whether it was damaged in shipping.
The following item should be in the box with the fixture:-
Color/Gel frame
Please handle the fixture with care at all times. Do not drop. Do not hit the front lens assembly.
2. Safety Instructions.
This device has left the factory in perfect condition. In order to maintain this condition and to ensure a
safe operation, it is absolutely necessary for the user to follow the safety instructions and warning
notes written in this user manual. Elektralite 1018 (5-in-1) is a high voltage fixture. Be careful when
dealing with high voltages.
Please read this manual. If you do not read this manual and damages occur to the Elektralite
1018 (5-in-1), then it could void the war ranty.
During shipping, the Elektralite 1018(5-in-1) may have been exposed to high temperature changes or
humidity changes. So, as a precaution, do not switch the Elektralite 1018(5-in-1) on immediately.
Condensation can damage the Elektralite 1018 (5-i n-1) so leave the Elektralite 1018 (5-in-1)
switched off until it has reached room temperature. The Elektralite 1018 (5-in-1) is an INDOOR
operational fixture. Do not operate this fixture outdoors or anywhere there is high humidity.
The electric connection must carry out by a qualified person and it is absolutely essential that the Elektralite 1018(5-in-1) be grounded. So under no circumstances break off the ground pin on the
Edison plug or use the fixture where a ground is not present. A ground pin, like the fuse for the
Elektralite 1018 (5-in-1) is there for safety.
Always disconnect the Elektralite 1018(5-in-1) from the power source, when the fixture is not in use
or before cleaning it. Only unplug Elektralite 1018(5-in-1) from the power source holding onto the
Edison plug. Never pull out the Edison plug out by just pulling on the power cord itself.
Please keep the Elektralite 1018 (5-in-1) away from children and the general public. Please be
intelligent and use common sense when operating the Elektralite 1018 (5-in-1).
3. General Guidelines.
Elektralite 1018 (5-in-1) is a lighting fixture for professional use on stages, in clubs, theatres, churches
etc.
Elektralite 1018 (5-in-1) should only be operated at between 120 to 240 volts and only indoors.
Elektralite 1018 (5-in-1) should not be operated 24/7 (24 hours a day; 7 days a week). Elektralite
1018 (5-in-1) needs operation breaks to ensure that it will work for a long time without problems.
Please do not shake the Elektralite 1018 (5-in-1) and avoid using brute force when installing or
operating it.
Please read this below. It is important to understand and realize the following:-
The lens encapsulates each of the leds. This way the maximum output is attained. However this
means that, if the fixture is dropped or the front lens assembly is struck, then it is possible for leds to be
crushed. So please exercise care and attention. This is not a par64 that can be abused at will!
When choosing the location to install the Elektralite 1018 (5-in-1), please make sure that it is not
exposed to extreme heat, moisture or dust and never install it outdoors. Make sure that the fixture has
a good amount of free space around it for air flow. Do not install it in a confined space or have
insulation around the fixture. The minimum distance between the Elektralite 1018 (5-in-1) and the
illuminated surface must be more than 3 feet.
Always mount the Elektralite 1 0 18 ( 5- i n -1) with an appropriate safety cable.
Operate the Elektralite 1018 (5-in-1) only when you are familiar with the features on the fixture. Do not
permit operation by persons not qualified.
All modifications to the Elektralite 1018 (5-in-1) will invalidate the warranty. There are absolutely no exceptions.
If Elektralite 1018 (5-in-1) is operated in any way different to the one described in this manual,
Elektralite 1018 (5-in-1) maybe damaged and the guarantee will be void.
4. Installation
Please ensure that the Elektralite 10 18 (5 - i n - 1) is hung using the appropriate "C" clamp or half
cheeseboro. A safety chain or cable should also be used as a secondary point of holding the fixture in
case the clamp comes loose. Never hang the fixture without a safety chain or cable. Make sure the Gel
frame (Gel holder) is clipped into position correctly and cannot come loose.
If you are not qualified or have any doubts about hanging the Elektralite 1018 (5-in-1) then do NOT
hang it.
Do not clamp the safety cable to the U bracket or clamp. That is not a secondary safety point.
A secondary safety point is any point that will adequately hold the Elektral ite 1018 (5-in-1) if the "C"
clamp or half cheesboro fails. Then the safety cable would be the backup and stop the fixture from
falling to the ground. So do NOT fix the safety cable to the same place that the "C"clamp is attached.
Ω
5. DMX-512 Control Connection
Connect an XLR cable to the female 5-pin XLR output of your Elektralite CP 20 or other DMX
controller. The other end should be connected to the male 5-pin XLR input of the Elektralite 1018
(5-in-1). Then daisy-chain out of the first Elektralite 1018 (5-in-1) into the next Elektralite 1018
(5-in-1) or other dmx device. Never “Y” split the DMX connection.
If you need more cable, then it should be two core, screened cable fitted with a 5 pin XLR input and
output connector. Please refer to the diagram below.
1
5
4
2
3
DMX-512 connection with DMX terminator
For installations where the DMX cable has to run a long distance or is in an electrically “noisy”
environment, it is recommended that a DMX terminator is used. This helps prevent corruption of the
digital control signal. The DMX terminator is simply a 5 pin XLR plug (male) with a 120 Ω resistor
connected between pins 2 and 3. It is then plugged into the output XLR socket of the last Elektralite 1018(5-in-1) or other dmx device in the chain. Please see illustration below.
5
4
1
2
3
120
6. Menus in the fixture.
Root Menu Sub Menu 1 Sub Menu 2
STAT (STATIC LOOK) R(ED) 0-255
G(REEN) 0-255
B(LUE) 0-255
W(HITE) 0-255
A(MBER) 0-255
S(STROBE) 0-255
AUTO (AUTOMATIC) AT 01 THROUGH TO AT10
PR 01 THROUGH TO PR10
RUN DMX
SLAV(E)
DMX ASSIGN DMX CHANNEL 1-512
PERS (PERSONALITY) STAG(E)
ARC1
ARC1d
ARC2
AR2d
AR2s
HSV
5CH
ID ID 01 THROUGH 66
EDIT PR01 SC01 THROUGH TO SC99
(MAKING OWN AUTO PR02 SC01 THROUGH TO SC99
SCENES) PR03 SC01 THROUGH TO SC99
PR04 SC01 THROUGH TO SC99
PR05 SC01 THROUGH TO SC99
PR06 SC01 THROUGH TO SC99
PR07 SC01 THROUGH TO SC99
PR08 SC01 THROUGH TO SC99
PR09 SC01 THROUGH TO SC99
PR10 SC01 THROUGH TO SC99
SET UPLD
DV
RGBW
DIM
ID
REST (RESET)
CAL1 WT01 THROUGH TO WT11
CAL2 RGB
KEY OFF
ON
7. Static Look.
The Elektralite 1018 (5-in-1) can be set to a single static look quickly.
Use the Menu button to get to STAT.
Press Enter.
The next screen will read R000. This is addressing the RED leds.
If Red is to be in the static look, then use the
Numbers are expressed in DMX values so 0 is no output and 255 is highest output.
Press Enter to save the value.
The screen will automatically advance to the next color Green.
If Green is to be in the static look, then use the ↑ or↓ to crease the value of green.
Press Enter to save the value.
The screen will automatically advance to the next color Blue.
If Blue is to be in the static look, then use the
Press Enter to save the value.
The screen will automatically advance to the next color White.
If White is to be in the static look, then use the
Press Enter to save the value.
The screen will automatically advance to the next color Amber.
If Amber is to be in the static look, then use the ↑ or
Press Enter to save the value.
The screen will automatically advance to the strobe function.
If the strobe function is to be in the static look, then use the ↑ or↓ to crease the value of strobes flash
rate.
Press Enter to save the value.
This is the last entry and the static look is complete. Pressing the Enter key just continues around if you
need to make fine adjustments to the color of the static look.
Do not press MENU as this will get you out to the Root directory and out of the static look.
↑ or ↓ to increase the value of the red.
↑ or↓ to crease the value of blue.
↑ or↓ to crease
↓ to crease the value of amber
the value of white.
.
8. Auto Programs.
The Elektralite 1018 (5-in1) can be set to run some inbuilt programs.
There are two types of programs in the Elektralite 1018 (5-in-1)
AT 01 to AT10 are fully pre-programmed and cannot be altered.
PR01 to PR10 are pre-programmed and can be edited
To run a program use the Menu button to get to AUTO.
Press ENTER.
Use the ↑ or ↓ key to get to the program. Press Enter.
The program will start running.
Loading...
+ 12 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.