1. Unpacking
Thank you for choosing the Elektra Lite LED P r o Line 1018 fixture. For your own safety, please read this manual before installing the device. This manual covers important information on installation and applications. Please keep this manual for future reference.
ElektraLite LED Pro Line 1018 wash fixture uses 18 high powered 10 watt quad leds in a balanced arrangement giving you incredible output. Please unpack it carefully and check whether it was damaged in shipping. The following items should be in the box with the fixture:-
Color/Gel frame
DMX 5 pin male to 5 pin female cable
2. Safety In st ructions.
This device has left the factory in perfect condition. In order to maintain this condition and to ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warning notes written in this user manual. ElektraLite LED Pro Line 1018 is a high voltage fixture. Be careful when dealing with high voltages.
Please read this manual. If you do not read this manual and damages occur to ElektraLite LED Pro Line 1018, then it could void the warranty.
During shipping, ElektraLite LED Pro Line 1018 may have been exposed to high temperature changes or humidity changes. So, as a precaution, do not switch ElektraLite LED Pro Line 1018 on immediately. Condensation can damage ElektraLite LED Pro Line 1018 s o leave ElektraLite LED Pro Line 1018 switched off until it has reached room temperature. The electric connection must carry out by a qualified person and it is absolutely essential that ElektraLite LED Pro Line 1018 be grounded.
Always disconnect ElektraLite LED Pro Line 1018 from the power source, when the device is not in use or before cleaning it. Only unplug ElektraLite LED Pro Line 1018 from the power cord. Never pull out the plug out by pulling on the power cord.
Please keep ElektraLite LED Pro Line 1018 away from children and the general public. Please be intelligent and use common sense when operating ElektraLite LED Pro Line 1018.
3. General Guidelines.
ElektraLite LED Pro Line 1018 is a lighting fixture for professional use on stages, in clubs, theatres,
etc.
ElektraLit e LE D P r o Li n e 1018 shou ld only b e oper ated at between 120 to 240 vo lts an d on ly ind oors. ElektraLite LED Pro Line 1018 should not be operated 24/7 (24 hours a day; 7 days a week). ElektraLite LED Pro Line 1018 needs operation breaks to ensure that it will work for a long time
without problems. Please do not shake ElektraLite LED Pro Line 1018 and avoid using brute force when installing or operating it. When choosing the location to install ElektraLite LED Pro Line 1018 , please make sure that it is not exposed to extrem e heat, m oisture or dust . Th e m inimum distance betw een E lektr aLi te LE D P ro Lin e 1018 and the illuminated surface must be more than 3 feet. Always mount ElektraLite LED Pro Line 1018 with an appropriate safety cable. Operate Ele ktr aLite LED Pr o Lin e 1018 only w hen you are familiar with the featu res o n the fix ture. Do not permit operation by persons not qualified for operating it. All modifications to ElektraLite LED Pro Line 1018 will invalidate the warranty. There are absolutely no exceptions. If ElektraLite LED Pro Line 1018 is operated in any way different to the one described in this manual,
ElektraLite LED Pro Line 1018 maybe damaged and the guarantee will be void.
4. Installation
Please ensure that the E lektr aLit e LED P r o Line 1018 is hung using the appropriat e "C" cl a mp or half cheeseboro. A safety chain or cable should also be used as a secondary point of holding the fixture in case the clamp com es loose. Never hang the fixture w ithout a safety c h a in or cab le. M ake su re the Ge l frame (Gel holder) is clipped into position correctly and cannot come loose. If you are not qualified or have any doubts about hanging the ElektraLite LED Pro Line 1018 then do NOT hang it. Do not clamp the cable to the U bracket or clamp. That is not a secondary safety point. A secondary safety point is any point that will adequately hold the ElektraLite LED Pro Line 1018 if the "C" clamp or half cheesboro fails. Then the safety cable would be the backup and stop the fixture from falling to the ground. So do NOT fix the safety to the same place that the "C"clamp is attached.
5. DMX-512 Control Connection
1
2
3
4
5
1
2
3
4
5
Ω
120
Connect the provided XLR cable to the female 5-pin XLR output of your Elektralite CP 20 or other DMX controller. The other end should be connected to the male 5-pin XLR input of the ElektraLite
LED Pro Li n e 1018. Then daisy-chain out of t he first E lektr aLi te LED P ro Lin e 1018 and into the nex t ElektraLite LED Pro Line 1018 or other dmx device. Never “Y” split the DMX connection.
If you need more cable, then it should be two core, screened cable fitted with a 5 pin XLR input and output connector. Please refer to the diagram below.
DMX-512 conn ect ion with DM X terminator
For installations where the DMX cable has to run a long distance or is in an electrically “noisy” environment, it is recommended that a DMX terminator is used. This helps prevent corruption of the digital control signal. The DMX terminator is simply a 5 pin XLR plug (male) with a 120 Ω resistor connected between pins 2 and 3. It is then plugged into the output XLR socket of the last LED Pro Line 1018 or other dmx device in the chain. Please see illustration below.
ElektraLite

6. Menus i n the fixture.

Root Menu Sub Menu 1 Sub Menu 2

STAT (STATIC LOOK) R(ED) 0-255 G(REEN) 0-255 B(LUE) 0-255 W(HITE) 0-255 S(STROBE) 0-255 AUTO (AUTOMATIC) PR 01 THROUGH TO PR10 RUN DMX SLAV(E) DMX ASSIGN DMX CHANNEL 1-512 PERS (PERSONALITY) STAG(E) ARC1 ARC1d ARC2 AR2d AR2s HSV ID ID 01 THROUGH 66 EDIT PR01 SC01 THROUGH TO SC99 (MAKING OWN AUTO SCENES) PR03 SC01 THROUGH TO SC99 PR04 SC01 THROUGH TO SC99 PR05 SC01 THROUGH TO SC99 PR06 SC01 THROUGH TO SC99 PR07 SC01 THROUGH TO SC99 PR08 SC01 THROUGH TO SC99 PR09 SC01 THROUGH TO SC99 PR10 SC01 THROUGH TO SC99 SET UPLD DV RGBW DIM ID REST (RESET) CAL1 WT01 THROUGH TO WT11 CAL2 RGB KEY OFF ON
AT 01 THROUGH TO AT10
PR02 SC01 THROUGH TO SC99
7. Static Look.
The ElektraLite LED Pro Line 1018 can be set to a single static look quickly. Use the Menu button to get to STAT. Press Enter. The next screen will read R000. This is addressing the RED leds. If Red is to be in the static look, then use the ↑ or ↓ to increase the value of the red. Numbers are expressed in DMX values so 0 is no output and 255 is highest output. Press Enter to save the value. The screen will automatically advance to the next color Green. If Green is to be in the static look, then use the ↑ or↓ to crease the value of green. Press Enter to save the value. The screen will automatically advance to the next color Blue. If Blue is to be in the static look, then use the ↑ or↓ to crease the value of blue. Press Enter to save the value. The screen will automatically advance to the next color White. If White is to be in the static look, then use the ↑ or↓ to crease the value of white. Press Enter to save the value. The screen will automatically advance to the strobe function. If the strobe function is to be in the static look, then use the ↑ or↓ to crease the value of strobes flash rate. Press Enter to save the value. This is the last ent ry an d the static look is complete. Pressing the E nter key j ust c ont inues a r ound if you need to make fine adjustments to the color of the static look. Do not press MENU as this will get you out to the Root directory and out of the static look.
8. Auto Programs.
The ElektraLite LED Pro Line 1018 can be set to run some inbuilt programs. There are two types of programs in the ElektraLite LED Pro Line 1018 AT 01 to AT10 are fully pre-programmed and cannot be altered. PR01 to PR10 are pre-programmed and can be edited To run a program use the Menu button to get to AUTO. Press ENTER. Use the ↑ or ↓ key to get to the program. Press Enter. The program will start running.
9. Run Mode.
Run allows the fixture to operate in either DMX or Slave operation. Using the Menu button in the root menu go to RUN. Press Enter to get to DMX mode. To get to SLAV mode use the ↑ or ↓ And press enter to save this setting.