Elektra Beckum Compresor Power 260 User Manual

Power 260
Betriebsanleitung. . . . . . . . . . . . . . . . . . . . 3
Operating Instruction . . . . . . . . . . . . . . . . . 7
Instructions d'utilisation . . . . . . . . . . . . . . 11
Handleiding . . . . . . . . . . . . . . . . . . . . . . . 16
Manuale d’istruzioni. . . . . . . . . . . . . . . . . 21
Manual de uso . . . . . . . . . . . . . . . . . . . . . 26
Betjeningsvejledning . . . . . . . . . . . . . . . . 31
Bruksanvisning . . . . . . . . . . . . . . . . . . . . 35
Käyttökäsikirja . . . . . . . . . . . . . . . . . . . . . 39
115 168 3572 / 3003 - 1.1
S
Ê
A
ÖRSÄ
E
K
A
U2K0041.fm
D DEUTSCH ENG ENGLISH
KONFORMITÄTSERKLÄRUNG DECLARATION OF CONFORMITY Wir erklären in alleiniger Verantwortlichkeit, dass dieses Produkt mit
den folgenden Normen übereinstimmt* gemäß den Bestimmungen der Richtlinien**
F FRANÇAIS NL NEDERLAND DECLARATION DE CONFORMITE CONFORMITEITSVERKLARING
Nous déclarons, sous notre seule responsabilité, que ce produit est en conformité avec les normes ou documents normatifs suivants* en vertu des dispositions des directives **
IT ITALIANO ES ESPAÑOL DICHIARAZIONE DI CONFORMITÀ DECLARACION DE CONFORMIDAD
Noi dichiariamo sotto la nostra esclusiva responsabilità che il presente prodotto è conforme alle seguenti norme* in conformità con le disposizioni delle normative **
PT PORTUGU DECLARAÇÃO DE CONFORMIDADE
Declaramos sob nossa responsabilidade que este produto está de acordo com as seguintes normas* de acordo com as directrizes dos regulamentos **
FIN SUOMI NO NORGE VAATIMUKSENMUKAISUUSVAKUUTUS SAMSVARSERKLÆRING
Vakuutamme, että tämä tuote vastaa seuraavia normeja* on direktiivien määräysten mukainen**
DA DANS OVERENSSTEMMELSESATTEST OŚWIADCZENIE O ZGODNOŚCI
Hermed erklærer vi på eget ansvar, at dette produkt stemmer overens ed følgende standarder* iht bestemmelserne i direktiverne**
EL ΕΛΛHNIK ∆ΗΛΩΣΗ ΑΝΤΙΣΤΟΙΧΕΙΑΣ MEGEGYEZŐSÉGI NYILATKOZAT
∆ηλώνουµε µε ιδία ευθύνη ότι το προϊόν αυτό αντιστοιχεί στις ακόλουθες προδιαγραφές* σύµφωνα µε τις διατάξεις των οδηγιών**
S SV SVENSK
We herewith declare in our sole responsibility that this product complies with the following standards* in accordance with the regulations of the undermentioned
Wij verklaren als enige verantwoordelijke, dat dit product in overeenstemming is met de volgende normen* conform de bepalingen van de richtlijnen**
Declaramos bajo nuestra exclusiva responsabilidad, que el presente producto cumple con las siguientes normas* de acuerdo a lo dispuesto en las directrices** Homologación de
KRAN OM ÖVERENSSTÄMMELS
F Vi försäkrar på eget ansvar att denna produkt överensstämmer med
följande standarder* enligt bestämmelserna i direktiven**
Vi erklærer under eget ansvar at dette produkt samsvarer med følgende normer* henhold til bestemmelsene i direktiv**
POL POLSKI
Oświadczamy z pełną odpowiedzialnością, że niniejszy produkt odpowiada wymogom następujących norm* według ustaleń wytycznych **
HU MAGYAR
Kizárólagos felelősségünk tudatában ezennel igazoljuk, hogy ez a termék kielégíti az alábbi szabványokban lefektetett követelményeket* megfelel az alábbi irányelvek előírásainak**
POWER 260
* EN 60204-1, EN 60335-1, EN 1012-1
** 98/37/EG - 93/ 68/EWG - 89/336/EWG - 73/23/EWG - 87/404/EWG - 2000/14/EG
Jürgen Kusserow
Vorstand
ELEKTRA BECKUM AG – Daimlerstraße 1 – 49716 Meppen
1001038/ 01
2
XK0020E.fm Operating Instruction ENGLISH
1. Device overview
12
11
ENGLISH
10
1 Compressor pump
3
4
5
89
7
6
2 Carrying handle
3 On/Off switch
4 Pressure regulator
5 Compressed air outlet
(quick coupler)
6 Outlet pressure gauge
7 Condensate drain screws
8 Tank pressure gauge
9 Safety valve
10 Pressure vessel
11 Air intake filter housing
7
ENGLISH
Table of Contents
1. Device overview ..........................7
2. Please Read First! .......................8
3. Safety ...........................................8
3.1 Specified conditions of use ...........8
3.2 General safety information............8
3.3 Safety devices...............................9
4. Operation .....................................9
4.1 Mains connection ..........................9
4.2 Generating compressed air...........9
5. Care and Maintenance ................9
5.1 Periodic maintenance....................9
5.2 Device storage ..............................9
6. Trouble Shooting ........................9
7. Repairs .......................................10
8. Environmental Protection ........10
9. Technical Specifications ..........10
2. Please Read First!
Read these instructions before use. Pay special attention to the safety information.
If you notice transport damage while unpacking, notify your supplier immediately. Do not operate the device!
Dispose of the packing in an envi­ronmentally friendly manner. Take to a proper collecting point.
Keep these instructions for refer­ence on any issues you may be uncertain about.
If you lend or sell this device be sure to have the instructions to go with it.
3. Safety
3.1 Specified conditions of use
This device is intended to generate com­pressed air required for the operation of air tools.
Any use for medical purposes, food processing as well as filling of oxygen cylinders for breathing equipment is not permitted.
Explosive, combustible gases or gases detrimental to health may not be com­pressed. Operation in hazardous loca­tions is not permitted.
Any other use is not as specified. Use not as specified, alteration of the device or use of parts that are not approved by the equipment manufacturer, can cause unforeseeable damage!
Children, juveniles and persons not hav­ing been instructed in its usage are not permitted to operate this device and any air tools connected to it.
3.2 General safety information
When using this electric tool observe the following safety instructions, to exclude the risk of personal injury or material damage. Please also observe the special safety instructions in the respective chapters; Keep all documents, supplied with the device, for future reference. Observe the statuary accident insurance institution regulations and regulations for the prevention of accidents pertaining to the operation of air compressors and air tools, where applicable.
A
General hazard!
Keep your work area tidy – a messy work area invites accidents. Be alert. Know what you are doing. Set out to work with reason. Do not operate electric tool while under the influence of drugs, alcohol or medication. Consider environmental conditions. Keep work area well lighted. Prevent adverse body positions. Ensure firm footing and keep your balance at all times. Do not operate electric tool near inflam­mable liquids or gases. Keep bystanders, particularly children, out of the work area. Do not permit other persons to touch the tool or power cable while the electric tool is running. Do not overload electric tool – use it only within the performance range it was designed for (see Technical specifica­tions).
B
Danger! Risk of electric shock!
Do not expose electric tool to rain. Do not operate electric tool in damp or wet environment. Prevent body contact with earthed objects such as radiators, pipes, cooking stoves or refrigerators when operating this electric tool. Do not use the power cable for any pur­pose it is not intended for.
A
Risk of personal injury by escaping compressed air and parts hurled about by escaping air!
Never direct compressed air against per­sons or animals! Ensure all air tools and accessories used are designed for the working pres­sure or are supplied via a pressure regu­lator. Please note that, when disconnecting the quick coupler, the compressed air contained in the pressure hose will escape all of a sudden. You should therefore firmly hold the air hose when disconnecting it. Ensure all screwed connections are fully tightened at all times. Do not attempt to repair the device your-
self! Only trained specialists are permit­ted to service or repair compressors, pressure vessels and air tools.
Hazard generated by oil-satu-
A
rated compressed air!
Use oil saturated compressed air only for air tools requiring such supply. Do not use an air hose used to supply com­pressed air containing oil to supply air tools not designed for operation on com­pressed air containing oil. Do not fill tires with compressed air containing oil.
A
Risk of burns from the sur­faces of parts carrying compressed air!
Let device cool off before servicing.
Risk of personal injury and
A
crushing by moving parts!
Do not operate the device without installed guards. Please note that the device will start automatically when the pressure falls off to minimum! – Disconnect from power supply prior to any servicing. Ensure that when switching on (e.g. after servicing) no tools or loose parts are in the electric tool.
Hazard generated by insuffi-
A
cient personal protection gear!
Wear hearing protection. Wear safety glasses. Wear mask respirator when work gener­ates dust or mist detrimental to health. Wear suitable work clothes When work­ing outdoors wearing of non-slip shoes is recommended.
Hazard generated by electric
A
tool defects!
Keep electric tool and accessories in good repair. Observe the maintenance instructions. Prior to any use check the electric tool for possible damage: before using the electric tool carefully check safety devices, protection devices or slightly damaged parts for proper function as specified. Check to see that all moving parts work properly and do not jam. All parts must be correctly installed and meet all conditions necessary for the proper operation of the electric tool. Damaged protection devices or parts must be repaired or replaced by an qual­ified specialist. Have damaged switches replaced by a service centre. Do not operate electric tool if the switch can not be turned ON or OFF. Keep handles free of oil and grease.
8
3.3 Safety devices
Safety valve
ENGLISH
13
15
Check all screwed connections for tightness, tighten if necessary.
Check power supply cable for dam­age, if necessary have replaced by a qualified electrician.
Every 50 operating hours
Check air intake filter (18), clean if necessary.
12
The spring safety valve (12) is incorpo­rated into the pressure switch unit. The safety valve opens if the max. permissi­ble pressure is exceeded.
4. Operation
4.1 Mains connection
Danger! High voltage
B
Operate device in dry environ­ment only. Operate device only on a power source complying with the following requirements:
outlets properly installed, earthed and tested;
fuse protection in accordance with the Technical Specifications.
Position power cable so it does not interfere with the work and is not damaged.
Always check to see that the device is switched OFF before plugging in.
Protect power cable from heat, aggressive liquids and sharp edges.
Use only extension cables with suffi­cient lead cross section (see "Techni­cal Specifications").
Do not stop the compressor by unplugging, but switch OFF using the switch.
Unplug after use.
4.2 Generating compressed air
1. Start device (13) and wait until the max. tank pressure is reached (compressor shuts off). The tank pressure is indicated by the tank pressure gauge (14).
17
16
14
2. Set pressure regulator (15) to required working pressure. The cur­rent working pressure is indicated by the regulated pressure gauge
(16).
Caution!
A
The regulated pressure may not be set higher than the max. work­ing pressure of the connected air tools!
3. Connect air hose to compressed air
outlet (17).
4. Connect air tool.
You are now ready to work with the air tool.
5. Switch the device OFF, if you do not
continue working immediately after­wards. Unplug after switching OFF.
5. Care and Maintenance
Danger!
A
Prior to all servicing:
Switch Off.
Unplug.
Wait until the device has come to
a complete stop.
Ensure the device and all air tools and accessories connected to it are relieved from pressure.
Let the device and all air tools and accessories used cool off.
After all servicing:
Check to see that all safety devices are operational.
Make sure that no tools or other parts remain on or in the device.
Repair and maintenance work other than described in this section must only be carried out by qualified spe­cialists.
5.1 Periodic maintenance
Prior to each use
Check air hoses for damage, replace if necessary.
18
Drain condensate (19).
19
Every 250 operating hours
Replace air filter element.
5.2 Device storage
1. Switch unit OFF and unplug.
2. Release pressure from tank and all connected air tools.
3. Store device in such way that it can­not be started by unauthorized per­sons.
Caution!
A
Do not store device unpro­tected outdoors or in damp environ­ment. Do not lay device on its side for transportation or storing.
6. Trouble Shooting
Danger!
A
Prior to all servicing:
Switch Off.
Unplug.
Wait until the device has come to
a complete stop.
Ensure the device and all air tools and accessories connected to it are relieved from pressure.
Let the device and all air tools and accessories used cool off.
9
ENGLISH
After all servicing:
Check to see that all safety devices are operational.
Make sure that no tools or other parts remain on or in the device.
Compressor does not run:
No mains voltage.
Check cables, plug, outlet and
mains fuse.
Mains voltage too low.
Use only extension cables with
sufficient lead cross section (see "Technical Specifications"). Avoid using extension cable with cold device.
Compressor was stopped by unplugging.
Switch compressor OFF at the
On/Off switch, then ON again.
Motor has overheated, caused by insufficient cooling (cooling fins covered).
Remove cause for overheating and allow to cool down for approx. 10 minutes, then start again.
Compressor runs but does not build up sufficient pressure.
Condensate drain of pressure ves­sel leaky.
Check gasket of drain screw(s);
replace if necessary.
Tighten drain screw(s) fingertight.
Check valve leaky.
Have check valve serviced by
qualified service centre.
Air tool is not supplied with sufficient pressure.
Pressure regulator not opened wide enough.
Open pressure regulator more.
Hose connection between compres-
sor and air tool leaky.
Check air hoses, replace defec-
tive parts if necessary.
7. Repairs
Danger!
A
Repairs to power tools must be carried out by qualified electricians only!
Electric tools in need of repair can be send to the service centre in your coun­try. See spare parts list for address.
Please attach a description of the fault to the power tool.
8. Environmental Protection
The device's packaging can be 100 % recycled.
Worn out devices and accessories con­tain considerable amounts of valuable raw and plastic materials, which can be recycled.
These instructions are printed on chlo­rine-free bleached paper.
9. Technical Specifications
Suction capacity l/min 235
Free air delivery (volume flow rate) l/min 110
Filling rate l/min 120
Max. working pressure bar 8
Pressure vessel volume l 4
Pump model F 245
No. of cylinders 1
-1
Motor speed min
Motor capacity kW 1.5
Supply voltage (50 Hz) V 230
Rated current A 6.8
Fuse protection min. A 10 (time-lag)
Degree of protection IP 20
Maximum overall length when using extension cables with: – 3 x 1.0 mm – 3 x 1.5 mm – 3 x 2.5 mm
Dimensions: length x width x height mm 600 x 310 x 405
Weight kg 18
2
lead cross-section
2
lead cross-section
2
lead cross-section
2850
m m m
10 25 25
Sound pressure level at 1 m max. dB (A) 87 ± 3
10
Loading...