Cabinets: 4 x Xi 1122/85Horizontal coverage: 2 x 120°-150°
Amps: 2 x P 1200Average distance: 20-25 meters
Cabeling: 2 x NL4 long, 2 x NL4 short/longTotal amp. power: 1,600 Watts cont.
Dx38:1
Cabinets: 4 x Xi 1152 (64 or 94)Horizontal coverage: 2 x 120°-150°, *2 x 150°
Amps: 1 x P 1200, 1 x P 3000Average distance: 20-30 meters, *20-25 meters
Cabeling: 2 x NL4 long, 2 x NL4 short/longTotal amp. power: 3,000 Watts cont.
Dx38:1
Dx38 In 1In 2Out 1Out 2Out 3Out 4Preset *
#1Main LeftMain Right Lo LHi LLo RHi R#37 (1152/64), #39(1152/94)
For medium SPL’s as stand alone.
In higher SPL applications as supplement.
P2000 may be used through out (deduct ~3 dB on HF
input level).
P3000 may be used through out (deduct ~6 dB on HF
input level).
Cabinets: 2 x Xi 1123/106Horizontal coverage: 2 x 100°
Amps: 2 x P 1200Average distance: 25-30 meters
Cabeling: 2 x NL8 longTotal amp. power: 1,000 Watts
Dx38:1
Dx38 In 1In 2Out 1Out 2Out 3Out 4Preset *
#1Main LeftMain Right Lo LHi LLo RHi R#47
Cabinets: 4 x Xi 1122, 2 x Xi 2181Horizontal coverage: 2 x 120°-150°, 4 X 80°
Amps: 1 x P 1200, 1 xP 2000, 1x P 3000Average distance: 15-20 meters
Cabeling: 4 x NL4, 2 x NL8 Total amp. power: 4,300 Watts
Dx38:2
Dx38 In 1In 2Out 1Out 2Out 3Out 4Preset *
#1Main LeftMain Right Lo LHi LLo RHi R#35 (HP on 1&3 to 80Hz)
#2SubSub#42 (adjust Level on Out1)
For dance floor applications use 1 Xi 1122 per corner.
Try to keep subwoofers side-to-side whenever possible.
If no separate subfeed is available use sum L+R.
P3000 may be used through out alternatively.
3rd Xi 2181 may be added.
System Applications Xi Series
Disco, Theatre, Club, Band
2.2
2-Way Stereo+Sub
Cabinets: 4 x Xi 1152 (64 or 94), 2 x Xi 2181Horizontal coverage: 2 x 100°-120°, 4 x 60°, *4 x 90°
Amps: 1 x P 1200, 1 x P 3000Average distance: 15-20 meters
Cabeling: Total amp. power: 5,400 Watts (cont.)
Dx38:2
Cabinets: 4 x Xi 1123, 6 x Xi 2181Horizontal coverage: 4 x 100°
Amps: 2 x P 2000, 3 x P3000Average distance: 20 meters
Cabeling: Total amp. power: 9,800 Watts (cont.)
Dx38:2
Dx38 In 1In 2Out 1Out 2Out 3Out 4Preset *
#1Main LeftMain Right Lo LHi LLo RHi R#47
#2SubSub#42 (adjust Level on Out1)
MF and HF horns could be rotated for vertical use.If no seperate sub signal available, use Sum L+R.
System Applications Xi Series
Small Theatre
2.4
2-Way LCR+Sub
Cabinets: 3 x Xi 1123, 2 x Xi 1191Horizontal coverage: 3 x 100°
Amps: 4 x P 2000Average distance: 20-35 meters
Cabeling: Total amp. power: 4,400 Watts
Dx38:2
Dx38 In 1In 2Out 1Out 2Out 3Out 4Preset *
#1Main LeftCenterLo LHi LLo CHi C#47
#2Main Right SubLo RHi RSub#47(Out1&2), #48 (route Out4 to In2)