RE90H
RE90WH
Condenser Cardioid
Hanging Microphone
• Non-reflecting black (RE90H) or
low-gloss white (RE90WH) with
matching cable.
• Shielded pre-amp is highly-resistant
to electrical noise and radio frequency
interference.
• 25-ft. braided, shielded cable maintains
microphone's position (not rotation)
• Cardioid polar pattern
• Three-pin male XLR-type output connector fits with female bulkhead XLR-type
connector
Description and Application
The RE90H and RE90WH of the Architectural Microphone Series are back-electret
condenser hanging microphones providing
an extended, flat frequency response with a
controlled cardioid polar pattern for highquality sound reinforcement. The RE90H is
specifically designed for live pickup of
choirs, instrumental and vocal groups, and
theater. The size and color of the transducer
and cable allow the microphone to blend in
with its surroundings.
The RE90H’s low self-noise and high-output signal level combine to produce lownoise, sound-reinforcement and recording.
Exceptionally high sensitivity, a uniform cardioid polar response, and smooth frequency
response make the RE90H ideally suited for
distant sound pick-up. The cardioid polar
pattern is precisely controlled and is highly
effective in suppressing feedback without
coloration of sound. Power for the RE90H
is obtained from any phantom source supplying 9 to 52 volts.
The RE90H is furnished with 25 feet of black
(RE90H) or white (RE90WH) miniature
braided shielded cable. The design of the
cable ensures the microphone’s horizontal
position will be held stable without the need
for fish-line tethering.
The RE90H is easily aimed at the performance with the supplied steel wire hanger
and holding nut. The wire hanger attached
to the microphone element and cable can be
bent to aim the microphone in the vertical
plane. To position the microphone on the
horizontal plane, loosen the holding nut on
the back of the microphone and slightly twist
the microphone on the wire holder (clockwise rotation rotates the RE90H to the left;
counterclockwise rotation rotates the RE90H
to the right). Secure this position by tightening the holding nut.
Note: For fixed installations, allow the microphone cable to hang for at least 24 hours
so the cable can completely relax and establish a set. This allows the microphone to be
accurately positioned over a choir, stage or
orchestra.
Application Notes
When hanging one or more microphones to
provide coverage for a choir, instrumental
or theater group, the best microphone position for optimum sound quality and feedback
control depends on many factors–sound system characteristics, construction of the au-
ditorium or theater, and the size and nature
of the performing group. Two general rules
to observe for the best sound coverage are
(1) microphone position and (2) the “3-to-1
rule.”
The first rule is to suspend the microphone
approximately two to three feet in front of
the first row of performers and two to three
feet higher than the heads of the last row of
performers. The microphones are usually
aimed to point at the last row of performers
(see Figure 3).
The second rule, the “3-to-1 rule,” should
be applied when more than one microphone
is required, and their outputs are combined
(as with a mixer). Following the 3-to-1 rule
avoids the deep voids and dips in frequency
response that occur when two or more microphones “see” the same signal from
slightly different distances. The 3-to-1 rule
is as follows: when multiple microphones are
used, place them at least three times as far
apart as any one of them is from the nearest
sound source. Figure 4 shows a proper application of the 3-to-1 rule.
The RE90H may also be used to provide coverage for live theater applications (Figure 5).
Most of the action occurs at center stage, so
the microphone should be positioned above

RE90H/RE90WH Condenser Cardioid Hanging Microphone
and pointed to the center of the stage.
Architectural & Engineering
Specifications
The microphone shall be a back-electret
condenser type with a frequency response
of 75 Hz to 15 kHz. The microphone shall
have a cardioid polar pattern with a rear response which is typically 15 dB below the
front response at 1.0 kHz. The microphone
shall have an output power level of -30.4 dB,
where 0 dB = 1 milliwatt per pascal, and
output shall not be appreciably affected by
the following temperature and humidity extremes: -29° to 74°C (-20° to 165°F) when
the relative humidity is 0-50%; -29° to 57°C
(-20° to 135°F) when relative humidity is
0-95%. The microphone shall have a nominal, balanced output impedance of 200 ohms
when connected to its electronics module.
The microphone shall have a low-gloss black
finish (RE90H) or a low-gloss white finish
(RE90WH). The cable color shall match the
transducer. The transducer shall have a wire
hanger for directing the microphone. Dimensions: the transducer shall be 12.7 mm
RE90H/RE90WH Condenser Cardioid Hanging Microphone
(0.4 in.) wide and 36.8 mm (1.4 in.) long;
the cable shall be 7.6 m (25 ft) long and
2.6 mm (0.1 in.) in diameter. The electronics module shall be a metal cylinder 94 mm
(3.7 in.) long and 19 mm (0.75 in.) in diameter. Termination to the electronics module
shall be a 3-pin male XLR type connector.
The Electro-V oice RE90H and RE90WH are
specified.
Warranty (Limited)
Electro-Voice products are guaranteed
against malfunction due to defects in materials or workmanship for a specified period,
as noted in the individual product-line
statement(s) below, or in the individual prod-
uct data sheet or owner’s manual, beginning
with the date of original purchase. If such
malfunction occurs during the specified period, the product will be repaired or replaced
(at our option) without charge. The product
will be returned to the customer prepaid.
Exclusions and Limitations: The Limited
W arranty does not apply to: (a) exterior finish or appearance; (b) certain specific items
described in the individual product-line
statement(s) below, or in the individual product data sheet or owner’s manual; (c) malfunction resulting from use or operation of
the product other than as specified in the
product data sheet or owner’s manual; (d)
malfunction resulting from misuse or abuse
of the product; or (e) malfunction occurring
at any time after repairs have been made to
the product by anyone other than ElectroVoice Service or any of its authorized service representatives. Obtaining Warranty
Service: To obtain warranty service, a customer must deliver the product, prepaid, to
Electro-Voice Service or any of its authorized service representatives together with
proof of purchase of the product in the form
of a bill of sale or receipted invoice. A list of
authorized service representatives is available from Electro-V oice Service at 600 Cecil
Street, Buchanan, MI 49107 (800/234/6831
or FAX 616/695/4743). Incidental and
Consequential Damages Excluded: Product repair or replacement and return to the
customer are the only remedies provided to
the customer. Electro-Voice shall not be liable for any incidental or consequential damages including, without limitation, injury to
persons or property or loss of use. Some
states do not allow the exclusion or limitation of incidental or consequential damages
so the above limitation or exclusion may not
apply to you. Other Rights: This warranty
gives you specific legal rights, and you may
also have other rights which vary from state
to state.
Electro-Voice Wired Microphones are
guaranteed against malfunction from any
cause for two (2) years from the date of original purchase. In addition, the Limited Warranty for the acoustic system contained in
these microphones shall apply for the life of
the product, defined as a period of ten (10)
years from the date that the manufacture of
the specific microphone has been discontinued. Any and all active electronics incorporated in these microphones are guaranteed
against malfunction due to defects in materials or workmanship for a period of three
(3) years from the date of original purchase.
The Limited Warranty does not extend to
cables, cable connectors, or switches. Additional details are included in the Uniform
Limited Warranty statement.
For warranty repair, service information, or
a listing of the repair facilities nearest you,
contact the service repair department at: 616/
695-6831 or 800/685-2606.
For technical assistance, contact Technical
Support at 800/234-6831 or 616/695-6831,
M-F , 8:00 a.m. to 5:00 p.m. eastern standard
time.