Key Features:
• Balanced frequency response
• Supercardioid polar pattern
• Powerful Neodymium magnet structure
• Shock mounted capsule and low handling noise
• Fast transient response
• Fine mesh Memraflex™ grille
General Description:
Thank you for purchasing the Electro-Voice® PL24 (or PL24S
switched version). This product is a professional-grade supercardioid dynamic microphone designed to capture the character of both
voice and instrument in live sound applications. With its balanced
frequency response, the PL24’s sonic performance is robust and
articulate, and delivers all around vocal clarity in any live sound situation. The enhanced isolation provided by its supercardioid polar
pattern is an excellent defense against system feedback and crosstalk bleed emanating from other nearby sound sources. The result
is higher gain before feedback and cleaner stage mixes. Although
designed to be a vocal microphone for music and spoken word, the
PL24 will also function well as an instrument or amplifier microphone
where a dynamic element capsule would be desired.
Application Notes:
As with most directional microphones, the low frequency response
of the PL24 microphone varies with the distance from the sound
source. Known as “proximity effect”, the bass response of the
microphone increases as the working distance to the microphone is
reduced. This “bass boost” is only audible when working at distances
closer than 6 inches. Using this microphone at distances greater
than 6 inches provides minimal coloration from proximity effect.
Proximity effect can be used to your advantage when a thin voice
is being recorded. As the vocalist decreases their working distance
to the microphone, the low frequency content is enhanced. Closeup positioning of the microphone will also reduce the potential for
feedback from the sound reinforcement system. When close-talked,
the bass-boost provides an increase in overall microphone output
level. The mixer gain may be proportionately reduced, resulting in
a reduction of the system’s sensitivity to feedback caused by the
sound entering the microphone from the loudspeakers.
Warranty:
This Electro-Voice® PL24 product is guaranteed against malfunction
due to defects in materials or workmanship for a period of three (3)
years from the date of original purchase. Please refer to the Limited
Warranty card included with your product for further warranty information.
PL24, PL24S
Dynamic Supercardioid
Vocal Microphone
Technical Specifications:
Element Type: Dynamic, Neodymium Magnet
Frequency Response: 80 Hz - 16,000 Hz
Polar Pattern: Supercardioid
Sensitivity, Open Circuit
Voltage, 1 kHz:
Polarity: Positive pressure on diaphragm
Rated Impedance: 600 ohms
Microphone Connector: 3-pin, XLR-type
Dimensions: Length = 7.23” (184.0 mm)
Accessories Included: Stand adapter with Euro-thread
Net Weight: 10.4 oz (294 g)
Shipping Weight: 19.3 oz (547 g)
Structure
2.2 mV/Pa (-53 dBV)
produces positive voltage on pin 2
relative to pin 3
Finish: Textured black satin handle with
MemraflexTM grille
Width = 2.10” (53.0 mm)
Shank = 0.93” (23.6 mm)
insert, Soft zippered gig bag
Frequency Response: Polar Response:
Locking Switch Feature (switched versions only)
To lock the switch
in the “ON” position,
slide the switch up
and rotate the small
screw in the center
of the switch button clockwise 90° as
shown.
To unlock the switch,
turn the screw counterclockwise 90°.
Microphone Use and Placement
Please note that micing techniques are a matter of personal preference. These are merely guidelines to assist in the placement of the
microphone to gain optimal performance.
Usage Optimal Placement
Vocals 0 to 6 inches away, aimed directly at the sound source.
Spoken Word 5 to 10 inches away, aimed directly at the sound source.
Standard Placement & Use Guidelines
1. Always point the microphone at the desired source of sound, and away from any unwanted sources.
2. The microphone should be located close to the sound source to minimize interference from other potential sound sources.
3. Use the 3-to-1 rule when using multiple microphones. Place each microphone three times farther from other microphones as from
the desired sound source.
4. Minimize over-handling of the microphone to reduce unwanted mechanical noise.
Dimension Drawing:
PL24 Part Numbers
PRD000157000 PL24, Dynamic Supercardioid Vocal •
Microphone
PRD000157001 PL24S, Dynamic Supercardioid Vocal •
Microphone with Switch
ACC000045000 SAPL-1, Replacement Microphone Stand •
Adapter
ACC000048001 WSPL-1, Optional Foam Windscreen, Black•
Electro-Voice
12000 Portland Avenue South, Burnsville, MN 55337
Phone: 952/884-4051, Fax: 952/884-0043
®
www.electrovoice.com
© Bosch Communications Systems 09/2008
Part Number LIT000228 Rev C
Europe, Africa, and Middle East only. For customer orders, contact Customer Service at:
U.S.A. and Canada only. For customer orders, contact Customer Service at:
800/392-3497 Fax: 800/955-6831
+ 49 9421-706 0 Fax: + 49 9421-706 265
Other Internatonal locations. For customer orders, Contact Customer Service at:
+ 1 952 884-4051 Fax: + 1 952 887-9212
For warranty repair or service information, contact the Service Repair department at:
800/685-2606
For technical assistance, contact Technical Support at: 866/78AUDIO
Specifications subject to change without notice.