General Description:
Designed specifically for horns, drums, acoustical and electric guitars, the N/D468 provides a smooth, natural sound, capturing the excitement of the instrument. The supercardioid pattern provides superior rejection and acoustic isolation in any application. An innovative EV design harnesses the increased power of a neodymium based magnet design, allowing a large-diameter voice coil (up to 50% larger than other mics) for dynamic, efficient microphone performance. N/DYM® offers the power and clarity to “cut through the mix.” Whatever your instrument application the N/D468 is sure to be a top performer.
Operation
The low frequency response of the N/D468 microphone varies with the distance from the sound source. Known as “proximity effect,” maximum bass response is produced in “close-up” use with the microphone 1/4 inch from the sound source. Normal bass response is experienced with working distances greater than 24 inches. Working close to the microphone will produce a more robust sound. Close up positioning of the microphone will also reduce the potential for feedback from the sound reinforcement system. When close­miced, the bass-boost provides an increase in overall microphone output level. The mixer gain may be proportionately reduced, resulting in a reduction of the system’s sensitivity to feedback caused by sound entering the microphone from the loudspeakers.
Technical Specifications:
:tnemelEerutcurtstengam®MYD/NcimanyD :esolC,esnopseR.qerFzH000,22-zH03 :raF,esnopseR.qerFzH000,22-zH06 :nrettaPraloPdioidracrepuS tiucriCnepO,ytivitisneS
:zHk1@egatloV :egnaRcimanyDBd441 :esioNtuptuOtnelaviuqEdethgiewABd41
:ytiraloPsesuacmgarhpaidnoerusserpevitisoP
:ecnadepmI)z-wol(decnalabsmho053 :rotcennoCenohporciMepyt-RLX,nip-3 :hsiniFkcalbgnitcelfer-noN :slairetaMneercsellirgxelfarmeM :dedulcnIseirosseccAretpadAdnatS113
:htgneL,snoisnemiD :retemaiD :knahS
:thgieWteN)g091(zo7.6 :thgieWgnippihS)g354(zo61
lacsap/Vm1.3
)mm511("5.4 )mm25("50.2 )mm02("08.0
)lacsap20000.0=Bd0(
3nip.fer2nipnoegatlovevitisop
gaB"giG"dereppiZtfoS
Polar Response:Frequency Response:
(5 dB per division)
1000 Hz
Microphone Use and Placement
Please note that micing techniques are a matter of personal preference. These are merely guidelines to assist in the placement of the microphone to gain optimal performance.
Usage Optimal Placement
Electric Guitar and Bass Guitar Amplifier Place microphone approximately 1-2" from and at a 90°degree angle to the speaker cone.
T o reduce boominess, move the microphone off axis to the cone from 90° to 45°, or move mic from center of cone to either edge.
Tom-Toms On double headed Toms place mic over the top of drum 1-3" and at a 45° angle to the
drum surface and 1-2" in from the drum edge. On single headed T oms use above method or place mic inside T om from underneath at a 90° angle from the center of head, 3-5", away.
Snare Drum Place mic 1-3" above the heads, 1-2" in from the rim. Aim each mic at the top heads
angled down about 45°. If the drum rings, tape deadening material to the head or use damping rings. For more “snare” sound place a 2nd mic underneath aimed up at the bottom of head.
Cymbals Place microphone one to two feet above the top of cymbals. High-Hat Place 5 inches above outside edge at a 45° down angle. Brass 6-24" away , and on axis with the bell of the instrument. Acoustic Guitar Place mic 6-12" from where finger board joins the body .
Instrumental Microphone Standard Placement & Use Guidelines
1. Always point the microphone at the desired source of sound, and away from any unwanted sources.
2.The microphone should be located close to the sound source to minimize interference from other potential sound sources.
3. Use the 3-to-1 rule when using multiple microphones. Place each microphone three times farther from other microphones as from the desired sound source.
4. Minimize over-handling of the microphone to reduce unwanted mechanical noise.
5.Working close to the microphone will increase the bass tone and also provide increased gain-before-feedback.
N/D468 Part Number: 16043008
12000 Portland Avenue South, Burnsville, MN 55337 Phone: 952/884-4051, Fax: 952/884-0043
www.electrovoice.com
© Telex Communications, Inc. 9/2003
Part Number 38109-831 Rev. B
U.S.A. and Canada only. For customer orders, contact Customer Service at:
Europe, Africa, and Middle East only. For customer orders, contact Customer Service at:
Other International locations. For customer orders, contact Customer Service at:
For warranty repair or service information, contact the Service Repair department at:
For technical assistance, contact Technical Support at:
Specifications subject to change without notice.
800/392-3497 Fax: 800/955-6831
+ 49 9421-706 0 Fax: + 49 9421-706 265
+ 1 952 884-4051 Fax: + 1 952 736-4212
800/553-5992 or 402/467-5321
800/392-3497 or 952/736-4656
Loading...