Electro-voice DPC 4000 User Manual

OWNER’S MANUAL
PROMATRIX paging stations DPC 4000
1 2
11 12
21 22
31 32
41 42 43
3
4
5
6
7
8
9
10
ALARM
13
14
15
16
17
18
19
20
23
24
25
26
27
28
29
30
33
34
35
36
37
38
39
40
44
45
46
47
48
49
50
ALL E
EINL ÖSCHEN
GO NG
PROG RAMMSTO PP
BUSYESC
SPRECHEN
TEXT
PROMATRIX System
CONTENTS
CONTENTS 18
SYSTEM OVERVIEW 20
PAGING STATION FUNCTIONS 21
CONTROL PANEL DPC 4550 22 CONNECTIONS 24
KEY LABELING 24
OPERATION 25
Selective Call 25 Collective Call 25 Direct Call 25 Gong Signal 25 Text Message 26 General Alarm 26 Selective Alarm 26 Canceling Signals 26 System ON / OFF 27 Program Routing 27 Special Functions 27
INDICATORS 28 PRIORITIES 29
DPC 4350 PAGING STATION EXTENSION 29
FACTORY SETTINGS 30
SPECIFICATIONS 31
WARRANTY 48
18 Revision 1.1 DPC 4000
PROMATRIX System
DPC 4000 Revision 1.1 19
PROMATRIX System
System Overview
The PROMATRIX system includes 5 different paging station models and one paging station extension of the DPC 4000 - series. All paging stations employ gooseneck-microphones, 6 or respectively 8 function keys, and a covered alarm key. An additional key as well as a key-lock switch can be retrofitted. All paging stations are available with 10, 20, 30, or 50 selection keys. All models come with LC-display (2 lines with 16 characters each).
The individual models are listed in the following table:
DPC 4106 6 function keys DPC 4510 8 function keys + 10 selection keys + alarm key DPC 4520 8 function keys + 20 selection keys + alarm key DPC 4530 8 function keys + 30 selection keys + alarm key DPC 4550 8 function keys + 50 selection keys + alarm key
DPC 4350 paging station extension with 50 selection keys
The paging stations employ the following common features:
all functions are processor-controlled
non-volatile configuration data FLASH-memory
condenser microphone incl. pre-amplifier and compressor / limiter
freely programmable key-assignment
easy labeling the keys via label-strips and MS WORD templates
monitoring of the analog circuitry via integrated pilot-tone oscillator
monitoring of the processor system via watchdog-circuit
line-monitoring via pilot-tone and polling
covered alarm key (except at the DPC 4106)
prepared for retrofitting additional alarm keys or key-lock switches
prepared for the connection of an external PTT-type microphone or audio signal source
piezo-humming device for acoustic alerts
prepared for the installation of an optionally available loudspeaker
set-up mode allows altering parameter settings directly at the paging station
two-line LC-display
All paging stations are processor-controlled and provide several monitoring functions. The integrated watchdog­circuitry monitors the processor system while the audio section is guarded by the signal of a switchable pilot tone oscillator. Additionally, the internal supply voltage is constantly measured. Once it drops below a critical threshold, a warning signal is being transmitted. Line-monitoring for the audio-cabling as well as for all RS-485 control-lines allows the early recognition and signaling of line-interrupts and short-circuits.
Easy and comfortable configuration of the paging stations is accomplished through the use of the PROMATRIX Designer software. The graphical, dialog-oriented user-interface allows setting all key-functions, priorities, options, and several other parameters.
Note: Up to four paging stations can be connected to a single input of the central unit. However, it is
20 Revision 1.1 DPC 4000
important to keep the fact in mind that in case of line interruption or short-circuit several microphone terminals can fail at the same time. Despite, inputs allow only launching one message at a time. All other connected paging stations are presented with a busy-message. If these restrictions are not acceptable, every microphone terminal - or at least all directing stations and other important paging stations - should have their own input at the central unit.
PROMATRIX System
on / off
setup
Paging Station Functions
Next to elementary messaging, the paging stations offer several additional functions that in summation are shown in the following diagram. Which functions a microphone terminal can initiate depend on its configuration and priority setting.
Table of all functions
announcement
start
power
program
selective
collective
direkt
gong
text
general
selective
lines
lines
clear
all
stop
clear
special
paging station
service
Detailed information concerning the different functions is provided within the following chapters.
DPC 4000 Revision 1.1 21
start
macro
instruction
address
password
Pre-gong
buzzer
compressor
date / time
LCD-
contrast
Loading...