Electro-voice DPA4410, DPA4411 DATASHEET

0 (0)
Electro-voice DPA4410, DPA4411 DATASHEET

DPA4410/11

400 watt 4 Channel Power Amplifier

Key Features:

Configurable as a 2x200, 2x100 & 1x200, or 4x100 amplifier.

Operation with 70V loudspeaker networks or 4/8 ohms low-impedance systems

Outputs protected against idling, short-circuits, over-temp and load variations.

Integrated Remote Module for control and monitoring (DPA4411 only)

Routing switch for parallel operation of the amplifier’s inputs

Integrated Standby Power Supply

Remote-Start function for mains and battery operation with inrush current limiter protection.

Power-on noise attenuation.

Status-LED indicators.

LED meters with CLIP indication.

Active, temperature-controlled ventilation.

General Description:

The DPA4410/11 amplifiers have been specially designed to ensure durable performance and reliable operation of sound reinforcement systems with several independent loudspeaker lines. The units are best suited for paging and pre-recorded message installations, alert systems, and for general music applications in industrial enterprises, offices, multifunction halls, sport arenas, schools, churches, hotels, hospitals, super markets, cruise ships, and similar venues.

The DPA4410/11 amplifiers can either be operated on the AC mains or connected to an external 24 V battery power source. Switching to battery operation is accomplished via an internal relay.

The DPA4411 provides the following remote monitoring functions when used within a ProAnnounce system:

Setting input levels on channels 1-4

Reading level values of the audio level controls.

Setting level offsets via virtual controllers.

Mute function (via level controls).

Remote control power operation ON/OFF.

Battery operation remote control ON/OFF.

Monitoring and fault message transmission of thermal overload warnings on the mains transformer or power output stages.

Monitoring of the functioning of the power output stages 1 to 4 via pilot tone signal.

Ground fault detection for loudspeaker lines.

Technical Specifications:

Nominal output power with mains supply

4 x 100 W

Input characteristics:

Electronically balanced

Nominal input level

775 mV = 0 dBu / 10 k ohms

Power output characteristics:

Balanced, floating

Nominal output voltage -AC supply

100 V / 70 V / 50 V / 20 V

Nominal output voltage - battery supply

79 V / 56 V / 40 V / 16 V

at 24 V DC

 

Nominal load impedance

100 ohms (50 / 25 / 4 ohms)

Noise (A-weighted)

-56 dBu

THD

<1 %

Frequency response

60 Hz to 20 kHz

Distortion-limited response (PA

60 Hz to 5 kHz

NOMINAL -3dB, kS = 1 %)

 

Crosstalk

80dB at 1 kHz

MONITOR output characteristics:

Electronically balanced

MONITOR nominal output voltage

2 V = + 8.2 dBu

MONITOR nominal load impedance

600 ohms

MONITOR frequency response

60 Hz to 20 kHz

Operating temperature range

+5 °C to +40 °C

Dimensions

(W x H x D) 19“ (483 mm) x

 

3HU (132 mm) x 345 mm

Installation depth without external

340 mm

connectors

 

Installation depth incl. external

400 mm

connectors (max.)

 

Weight

22.5 kg

Color

Anthracite

Loading...