Electro-voice DPA4410, DPA4411 DATASHEET

DPA4410/11
400 watt 4 Channel Power Amplifier

Key Features:

Configurable as a 2x200, 2x100 & 1x200, or 4x100 amplifier.
Operation with 70V loudspeaker networks or 4/8 ohms low-impedance systems
Outputs protected against idling, short-circuits, over-temp and load variations.
Integrated Remote Module for control and monitoring (DPA4411 only)
Routing switch for parallel operation of the amplifier’s inputs
Integrated Standby Power Supply
Remote-Start function for mains and battery
operation with inrush current limiter protection.
Power-on noise attenuation.
Status-LED indicators.
LED meters with CLIP indication.
Active, temperature-controlled ventilation.

General Description:

The DPA4410/11 amplifiers have been specially designed to ensure durable performance and reliable operation of sound reinforcement systems with several independent loudspeaker lines. The units are best suited for paging and pre-recorded message installations, alert systems, and for general music applications in industrial enterprises, offices, multi­function halls, sport arenas, schools, churches, hotels, hospitals, super markets, cruise ships, and similar venues.
The DPA4410/11 amplifiers can either be operated on the AC mains or connected to an external 24 V battery power source. Switching to battery operation is accomplished via an internal relay.
The DPA4411 provides the following remote monitoring functions when used within a ProAnnounce system:
Setting input levels on channels 1-4
Reading level values of the audio level controls.
Setting level offsets via virtual controllers.
Mute function (via level controls).
Remote control power operation ON/OFF.
Battery operation remote control ON/OFF.
Monitoring and fault message transmission of
thermal overload warnings on the mains transformer or power output stages.
Monitoring of the functioning of the power output
stages 1 to 4 via pilot tone signal.
Ground fault detection for loudspeaker lines.

Technical Specifications:

Nominal output power with mains supply 4 x 100 W Input characteristics: Electronically balanced Nominal input level 775 mV = 0 dBu / 10 k ohms Power output characteristics: Balanced, floating Nominal output voltage -AC supply 100 V / 70 V / 50 V / 20 V Nominal output voltage - battery supply at 24 V DC Nominal load impedance 100 ohms (50 / 25 / 4 ohms) Noise (A-weighted) -56 dBu THD <1 % Frequency response 60 Hz to 20 kHz Distortion-limited response (PA NOMINAL -3dB, kS = 1 %) Crosstalk 80dB at 1 kHz MONITOR output characteristics: Electronically balanced MONITOR nominal output voltage 2 V = + 8.2 dBu MONITOR nominal load impedance 600 ohms MONITOR frequency response 60 Hz to 20 kHz Operating temperature range +5 °C to +40 °C Dimensions (W x H x D) 19“ (483 mm) x
Installation depth without external connectors Installation depth incl. external connectors (max.) Weight 22.5 kg Color Anthracite
79 V / 56 V / 40 V / 16 V
60 Hz to 5 kHz
3HU (132 mm) x 345 mm 340 mm
400 mm

Architecture & Engineering Specifications:

The remote control amplifier unit shall provide the following remote monitoring functions:
Setting input levels on channels 1-4
Reading level values of the audio level
controls.
Setting level offsets via virtual controllers.
Mute function (via level controls).
Remote control power operation ON/OFF.
Battery operation remote control ON/OFF.
Monitoring and fault message transmission of
thermal overload warnings on the mains transformer or power output stages.
Monitoring of the functioning of the power output stages 1 to 4 via pilot tone signal.
Ground fault detection for loudspeaker lines.
The amplifier shall either be powered by AC mains or connected to an external 24 V battery power source. Switching to battery operation shall be accomplished via an internal relay.
The amplifier shall be 3 RU in height and be configurable for 2x200, 1x200 & 2x100, or 4x100 watt operation. Jumpers located on the unit chassis shall
accomplish these operation mode changes. The output channels must be driven through on-board transformers.
The amplifier shall be the Dynacord ProAnnounce DPA4411 or DPA4410.

Available Accessories:

Model Cat. No. Description
NRS90206 121639 Pilot Tone Monitor module NRS90207 121799 Ground fault monitor module NRS90208 121641 Input transformer

Ordering Information:

Model Cat. No. Description
DPA4410 121792 4x100 Power Amplifier DPA4411 121793 4x100 Power Amplifier w/remote
2 3 4 5 14 13 11 6 7 8
12 15 1
1 DC INPUT 24 V = 9 ROUTING switch for INPUT 1-4 2 POWER ON switch 10 Device address label field 3 AC MAINS INPUT connector 11 ADDRESS selector switch 4 Mains fuse 12 POWER OUTPUT 5 VOLTAGE SELECTOR switch 13 Device output configuration label field 6 REMOTE CONTROL connectors 14 Air outlets 7 STATUS indicator 15 CIRCUIT GROUND TO CHASSIS GROUND SWITCH 8 INPUT connectors 1-4
USA and Canada Only. For customer orders contact Customer Service at: 800/392-3497 Fax: 800/955-6831
12000 Portland Av. South, Burnsville, MN 55337 Phone: 952-887-4051, Fax:952-887-0043
www.electrovoice.com
Telex Communications Inc 11/2002 Part Number 38109-xxx Rev A
10