DPA4410/11
400 watt 4 Channel Power Amplifier
Key Features:
• Configurable as a 2x200, 2x100 & 1x200, or
4x100 amplifier.
• Operation with 70V loudspeaker networks or 4/8
ohms low-impedance systems
• Outputs protected against idling, short-circuits,
over-temp and load variations.
• Integrated Remote Module for control and
monitoring (DPA4411 only)
• Routing switch for parallel operation of the
amplifier’s inputs
• Integrated Standby Power Supply
• Remote-Start function for mains and battery
operation with inrush current limiter protection.
• Power-on noise attenuation.
• Status-LED indicators.
• LED meters with CLIP indication.
• Active, temperature-controlled ventilation.
General Description:
The DPA4410/11 amplifiers have been specially
designed to ensure durable performance and reliable
operation of sound reinforcement systems with several
independent loudspeaker lines. The units are best
suited for paging and pre-recorded message
installations, alert systems, and for general music
applications in industrial enterprises, offices, multifunction halls, sport arenas, schools, churches, hotels,
hospitals, super markets, cruise ships, and similar
venues.
The DPA4410/11 amplifiers can either be operated on
the AC mains or connected to an external 24 V battery
power source. Switching to battery operation is
accomplished via an internal relay.
The DPA4411 provides the following remote
monitoring functions when used within a ProAnnounce
system:
• Setting input levels on channels 1-4
• Reading level values of the audio level controls.
• Setting level offsets via virtual controllers.
• Mute function (via level controls).
• Remote control power operation ON/OFF.
• Battery operation remote control ON/OFF.
• Monitoring and fault message transmission of
thermal overload warnings on the mains
transformer or power output stages.
• Monitoring of the functioning of the power output
stages 1 to 4 via pilot tone signal.
• Ground fault detection for loudspeaker lines.
Technical Specifications:
Nominal output power with mains supply 4 x 100 W
Input characteristics: Electronically balanced
Nominal input level 775 mV = 0 dBu / 10 k ohms
Power output characteristics: Balanced, floating
Nominal output voltage -AC supply 100 V / 70 V / 50 V / 20 V
Nominal output voltage - battery supply
at 24 V DC
Nominal load impedance 100 ohms (50 / 25 / 4 ohms)
Noise (A-weighted) -56 dBu
THD <1 %
Frequency response 60 Hz to 20 kHz
Distortion-limited response (PA
NOMINAL -3dB, kS = 1 %)
Crosstalk 80dB at 1 kHz
MONITOR output characteristics: Electronically balanced
MONITOR nominal output voltage 2 V = + 8.2 dBu
MONITOR nominal load impedance 600 ohms
MONITOR frequency response 60 Hz to 20 kHz
Operating temperature range +5 °C to +40 °C
Dimensions (W x H x D) 19“ (483 mm) x
Installation depth without external
connectors
Installation depth incl. external
connectors (max.)
Weight 22.5 kg
Color Anthracite
79 V / 56 V / 40 V / 16 V
60 Hz to 5 kHz
3HU (132 mm) x 345 mm
340 mm
400 mm
Architecture & Engineering
Specifications:
The remote control amplifier unit shall provide the
following remote monitoring functions:
• Setting input levels on channels 1-4
• Reading level values of the audio level
controls.
• Setting level offsets via virtual controllers.
• Mute function (via level controls).
• Remote control power operation ON/OFF.
• Battery operation remote control ON/OFF.
• Monitoring and fault message transmission of
thermal overload warnings on the mains
transformer or power output stages.
• Monitoring of the functioning of the power
output stages 1 to 4 via pilot tone signal.
• Ground fault detection for loudspeaker lines.
The amplifier shall either be powered by AC mains or
connected to an external 24 V battery power source.
Switching to battery operation shall be accomplished
via an internal relay.
The amplifier shall be 3 RU in height and be
configurable for 2x200, 1x200 & 2x100, or 4x100 watt
operation. Jumpers located on the unit chassis shall
accomplish these operation mode changes. The
output channels must be driven through on-board
transformers.
The amplifier shall be the Dynacord ProAnnounce
DPA4411 or DPA4410.
Available Accessories:
Model Cat. No. Description
NRS90206 121639 Pilot Tone Monitor module
NRS90207 121799 Ground fault monitor module
NRS90208 121641 Input transformer
Ordering Information:
Model Cat. No. Description
DPA4410 121792 4x100 Power Amplifier
DPA4411 121793 4x100 Power Amplifier w/remote
2 3 4 5 14 13 11 6 7 8
12 15 1
1 DC INPUT 24 V = 9 ROUTING switch for INPUT 1-4
2 POWER ON switch 10 Device address label field
3 AC MAINS INPUT connector 11 ADDRESS selector switch
4 Mains fuse 12 POWER OUTPUT
5 VOLTAGE SELECTOR switch 13 Device output configuration label field
6 REMOTE CONTROL connectors 14 Air outlets
7 STATUS indicator 15 CIRCUIT GROUND TO CHASSIS GROUND SWITCH
8 INPUT connectors 1-4
USA and Canada Only. For customer orders contact
Customer Service at: 800/392-3497 Fax: 800/955-6831
12000 Portland Av. South, Burnsville, MN 55337
Phone: 952-887-4051, Fax:952-887-0043
www.electrovoice.com
Telex Communications Inc 11/2002
Part Number 38109-xxx Rev A
10
9