Electro-Voice Computer Monitor User Manual

®
Force Monitor
• 12-inch two-way high-output stage system
• 150-watts continuous, 600-watts short-term power handling
• 80° x 55° Constant-directivity CD horn
• Usable monitor angles of 50° and 65°
• Integral 1 3/8-inch stand mount
• Choice of paralleled 1/4-inch or Neutrik Speakon
®
(-E) connectors
Description
The Electro-Voice Force peak output, high-efficiency super low pro­file two-way floor monitor. The Force Monitor features a constant directivity 80° x 55° horn in a vertical orientation that pro­vides usable monitor angles of 50° and 65°. The combined professional quality manufactured components arrange in a horizontal array with a very durable and road worthy light weight enclosure. The result is a very high performance system with excellent vocal reproduction and bass response that is surprising from such a small enclosure.
The Force design that presents a very minimal front cross section along with an exremely low profile. A top mounted strap handle al­lows for comfortable one handed transpor­tation. The design is light weight, but very rugged and features a heavy metal grill and highly stylized corner protection.
The Force mount adapter on the woofer side for ver­tical orientation (standard 1 3/8 diameter.)
®
Monitor enclosure has a unique
®
Monitor also features a stand
®
Monitor is a high-
Power-Handling Capacity
Electro-Voice components and systems are manufactured to exacting standards, en-
®
suring they will hold up, not only through the most rigorous of power tests, but also through continued use in arduous, real­life conditions. The EIA Loudspeaker Power Rating Full Range (ANSI/EIA RS­426-A 1980) uses a noise spectrum which mimics typical music and tests the ther­mal and mechanical capabilities of the components. Electro-V oice will support rel­evant additional standards as and when they become available. Extreme, in-house power tests, which push the performance boundaries of the woofers, are also per­formed and passed to ensure years of trouble-free service.
Specifically, the Eliminator Monitor passes ANSI/EIA RS-426-A 1980 with the follow­ing values:
R
= 6.55 ohms (1.15 x RE)
SR
= 150 watts
P
E(MAX)
Test voltage = 31.34 volts rms,
138.00 volts peak (+6dB)
The “peak” power-handling capacity of a woofer is determined by the peak test volt-
age amount. For the Eliminator Monitor, a
138.00-volt-peak-test voltage translates
into 600-watts short-term peak power-han­dling capacity. This is the equivalent of four times the “average” power-handling capacity, and is a peak that can be sus­tained for only a few milliseconds. How­ever, this sort of short duration peak is very typical in speech and music. Provided the amplifier can reproduce the signal accu­rately, without clipping, the woofer will also perform accurately and reliably, even at these levels.
Amplifier Recommendations
The power-handling rating of the Force Monitor is 150-watts continuous. The spe­cific tests used employ a crest factor (ratio of peak energy to continuous energy) of at least 6 dB. During extended testing, the
®
Force
Monitor is routinely subjected to peak levels far in excess of its continuous rating of 150 watts. Many amplifier de­signs are capable of producing peak power levels in excess of their ratings as well, so exact “pairing’ of loudspeaker rating and amplifier ratings is not necessary. Ampli­fier continuous ratings of 150 watts to 300 watts into 8 ohms are suggested. Larger amplifier ratings are recommended for maxi-
®
Force® Monitor
mum dynamic range, but it should be rec­ommended that amplifier continuous lev­els (as opposed to peak levels) be within the range quoted for the Force
®
Monitor
long-term average power-handling rating.
Uniform Limited Warranty
Monitor
®
Electro-Voice products are guaranteed against malfunction due to defects in ma­terials or workmanship for a specified pe-
Force
riod, as noted in the individual product­line statement(s) below, or in the individual product data sheet or owner’s manual, be­ginning with the date of original purchase. If such malfunction occurs during the specified period, the product will be re­paired or replaced (at our option) without charge. The product will be returned to the customer prepaid. Exclusions and Limita- tions: The Limited Warranty does not ap­ply to: (a) exterior finish or appearance; (b) certain specific items described in the indi­vidual product-line statement(s) below, or in the individual product data sheet or owner’s manual; (c) malfunction resulting from use or operation of the product other than as specified in the product data sheet or owner’s manual; (d) malfunction result-
ing from misuse or abuse of the product; or (e) malfunction occurring at any time after repairs have been made to the product by anyone other than Electro­Voice Service or any of its authorized ser­vice representatives. Obtaining Warranty Service: To obtain warranty service, a cus­tomer must deliver the product, prepaid, to Electro-Voice Service or any of its autho­rized service representatives together with proof of purchase of the product in the form of a bill of sale or receipted invoice. A list of authorized service representatives is available from Electro-Voice Service at 600 Cecil Street, Buchanan, MI 49107 (800/ 234-6831 or FAX 616/695-4743). Inci-
dental and Consequential Damages Ex­cluded: Product repair or replacement and
return to the customer are the only rem­edies provided to the customer. Electro­Voice shall not be liable for any incidental or consequential damages including, with­out limitation, injury to persons or prop­erty or loss of use. Some states do not allow the exclusion or limitation of inciden­tal or consequential damages so the above limitation or exclusion may not apply to you. Other Rights: This warranty gives
you specific legal rights, and you may also have other rights which vary from state to state.
Electro-V oice Speakers and Speaker Sys­tems are guaranteed against malfunction
due to defects in materials or workman­ship for a period of five (5) years from the date of original purchase. The Limited Warranty does not apply to burned voice coils or malfunctions such as cone and/or coil damage resulting from improperly de­signed enclosures. Electro-Voice active electronics associated with the speaker systems are guaranteed for three (3) years from the date of original purchase. Addi­tional details are included in the Uniform Limited Warranty statement.
For warranty repair, service information, or a listing of the repair facilities nearest you, contact the service repair department at: 616/695-6831 or 800/685-2606.
For technical assistance, contact Techni­cal Support at 800/234-6831 or 616/695­6831, M-F, 8:00 a.m. to 5:00 p.m. Eastern Standard time.
Specifications subject to change without notice.