Safety
BRKT-POLE-S and BRKT-POLE-L support a working load limit of
34.1kg (75lb) at a minimum structural safety factor of 8:1 when
used as intended.
The safety factor is the ratio of the
vided by the
represents the force at which a part will structurally fail. The
working load limit is the maximum load that the user shall apply.
The safety factor provides a margin of safety above the workingload limit to accommodate normal dynamic loading and normal
wear.
When loudspeaker systems are suspended using BRKT-POLE-S
or BRKT-POLE-L as illustrated in this manual, the bracket will be
within the working load limit of both the loudspeaker systems
and the mounting accessories, and a safety factor of at least 8:1
will be maintained.
The use of mounting configurations other than recommended by
Electro-Voice in this manual are at the risk of the user.
Prior to use, inspect the suspension points and associated hardware for any cracks, deformations, broken welds, corrosion,
missing or damaged components which could reduce the suspension points strength. Replace any damaged hardware. Never
exceed the limitations or maximum recommended load intended
for the suspension points. As an added safety measure, it is suggested the user install an extra suspension point back to the
building structural supports. This redundant safety point should
have as little slack as possible (less than one inch is preferable).
Prior to each use, inspect the loudspeaker enclosures for any
cracks, deformations, missing or damaged components, which
could reduce enclosure strength. Replace any loudspeaker systems that are damaged or missing hardware.
working load limit
Warning!
Suspending any object is potentially dangerous and
should only be attempted by individuals who have a
thorough knowledge of the techniques and regulations
of suspending objects overhead. Electro-Voice strongly
recommends that loudspeakers be suspended taking
into account all current national, federal, state, and
local laws and regulations. It is the responsibility of
the installer to ensure all loudspeakers are safely installed in accordance with all such requirements.
When loudspeakers are suspended, Electro-Voice
strongly recommends the system be inspected at least
once per year or as laws and regulations require. If
any sign of weakness or damage is detected, remedial
action should be taken immediately. The user is responsible for making sure the wall, ceiling, or structure is capable of supporting all objects suspended
overhead. Any hardware used to suspend a loudspeaker not associated with Electro-Voice is the responsibility of others.
Warning!
BRKT-POLE-S and BRKT-POLE-L are not designed for
direct exposure to rain and/or outdoor environments.
ultimate break strength
. The ultimate break strength
System overview
Thank you for choosing this pole mount bracket accessory. This
manual describes how to install various full-range loudspeaker
models on BRKT-POLE-S and BRKT-POLE-L pole mount brackets.
Parts included
Make sure that all parts are included and not damaged. If the
packaging or any parts are damaged, contact your shipper. If any
parts are missing, contact your Sales or Customer Service Representative.
Quantity Component
1 Pole mount bracket
2 Wall mounting spacer
Quantity Component
1 Quick installation guide
– Tilting upward or downward from the bracket arm pivot
axis.
– Combining any of the three adjustment points.
Compatible speakers
di-
BRKT-POLE-S is suitable for 8- and 10-inch speakers and some
12-inch speakers. BRKT-POLE-L is suitable for speakers up to 15
inches.
Loudspeaker model BRKT-POLE-S BRKT-POLE-L
ZLX 8" models
ZLX 12" models
ZLX 15" models
EKX 12" models
EKX 15" models
ELX 12" models
ELX 15" models
ELX200 10" models
ELX200 12" models
ELX200 15" models
ETX-10P
ETX-12P
ETX-15P
EVERSE 8
EVERSE 12
PX1122M
PX1152M
PXM-12MP
QRx 112/75
QRx 115/75
SX 12" models
TX1122
TX1152
ZX1 , ZXA1
ZX3
ZX4 , ZX5 , ZXA5
1
Limited horizontal angle and up tilt adjustability
✓ ✓
- ✓
- ✓
1
✓
- ✓
1
✓
- ✓
✓ ✓
- ✓
- ✓
1
✓
1
✓
- ✓
✓ ✓
1
✓
1
✓
- ✓
- ✓
- ✓
- ✓
✓ ✓
- ✓
- ✓
✓ ✓
- ✓
- ✓
✓
✓
✓
✓
✓
✓
1
1
Bracket parts
Pole mount
A
Swivel arm
C
Base plate
E
Vertical tilt hand screw
B
Swivel arm nut
D
Wall mounting spacers
F
Features
The pole mount bracket allows the loudspeaker angle to be adjusted as needed. The options are:
– Rotating to the left or right from the pole mount vertical
axis.
– Swiveling (panning) to the left or right from the bracket
swivel arm vertical axis.
Fig.1:
Rotating to the left or right from the pole mount vertical axis
Fig.2:
Swiveling (panning) to the left or right from the bracket swivel
arm vertical axis
Fig.3:
Tilting upward or downward from the bracket arm pivot axis
The maximum downward tilt of the pole mount bracket is 30 degrees. The maximum upward tilt is 5 degrees.
Installation
Caution!
Due to the weight of the Electro-Voice loudspeaker
system, it is imperative that the bracket is properly secured to the wall or pole. The choice of fastener (not
supplied) will be determined by the material and construction of the mounting surface. The user is responsible to ensure the mounting surface and fasteners are
capable of supporting the weight of the loudspeaker.
Caution!
We recommend that two or more persons lift and
place heavier loudspeakers. Single person lift and
placement of heavier loudspeakers could cause injury.
Pole mount bracket mounting options
When mounting the loudspeaker using the different
mounting options listed in this manual, make sure all the
hardware used is able to support a working load limit of
34.1kg. (75lb). Refer to
When mounting the bracket to a pole or post, make sure
the pole or post is fixed, secure and able to support the
working load limit. Never mount the bracket directly to a
tripod speaker stand as this will cause the stand to tilt
over and cause damage and/or injury.
To prevent unintentional removal of loudspeaker from
the bracket, make sure the set screw or thumb screw is
securely tightened, if available. Mount the bracket in a
location that is not easily accessible to prevent any unintentional or accidental removal of the loudspeaker.
Safety
for additional details.
Mounting to a wall
When mounting the bracket directly to a wall, make sure to use
the two wall mounting spacers (A) supplied. The wall mounting
spacers prevent the bracket from bending or warping when driving the screws to the wall. The bracket accepts fastener diameters up to 3/8 inches or M10.
Warning!
Mount the pole mount bracket directly to a wall stud.
Failure to do so can cause damage and/or injury.
Warning!
Do not mount the pole mount bracket to a ceiling,
floor or any surface that is not vertical. Do not mount
the bracket sideways or upside down.
Mounting to a vertical pole
The bracket can be mounted to a vertical pole using two U-bolts.
The outer holes accept 4 1/2" center to center U-bolts. The inner
slots accept a minimum 1 5/8", maximum 2 7/8" center to center U-bolts, which corresponds to a nominal pipe size between
1" (DN20) and 2" (DN50). Both positions accept a maximum bolt
diameter of 3/8" or M10. Refer to
sions.
Technical data
for slot dimen-
Fig.4:
Using U-Bolts with minimum 1-5/8-inch and maximum 2-7/8-
inch bolt centers
Fig.5:
Using U-Bolts with 4-1/2-inch bolt centers (maximum bolt dia-
meter 3/8-inch or M10)
Fig.6:
Using tube clamps (maximum strap width 3/4” or 20mm)
Notice!
There are many types of metal tube clamps. Depending on the type chosen, make sure the clamp load rating can handle the working load limit times a safety
factor of 8. Refer to
Safety
for additional details.

Installing the loudspeaker on the pole mount bracket
mm [in]
136.8
[5.39]
215.9
[8.50]
250
[9.84]
210
[8.27]
115.8
[4.56]
150
[5.91]
257.9
[10.15]
mm [in]
317.5
[12.50]
250
[9.84]
210
[8.27]
115.8
[4.56]
150
[5.91]
136.8
[5.39]
359.4
[14.15]
210
[8.27]
115.8
[4.56]
150
[5.91]
10.6
[0.41]
6x ∅11.4
[0.44]
25.4
[1]
85.6
[3.37]
29.4
[1.15]
To install models
1. Loosen the set screw without completely removing it.
The loudspeaker easily slides onto the pole mount.
Fig.7:
ZLX-8-G2
Fig.8:
ZLX-12-G2
2. With the bracket pole mount locked in a vertical position,
align the pole cup of the loudspeaker with the bracket pole
mount.
with a set screw
:
Fig.10:
ELX200 12"
adjust the swivel (pan) angle
To
:
1. Loosen the bracket swivel arm nut using 17mm socket or
adjustable wrenches.
2. Move the swivel arm to the left or right to set the loudspeaker to the required angle.
3. Allow enough space between the wall and the loudspeaker
for cable connections.
adjust the vertical (tilt) angle
To
:
1. Loosen the vertical tilt hand screw by hand.
2. While supporting the loudspeaker, move the loudspeaker up
or down to set to the required vertical angle.
Support the loudspeaker until the vertical hand screw is
tightened and the loudspeaker is fully secured.
3. Tighten the vertical hand screw until the loudspeaker is
locked in place.
Dimensions
Fig.11:
BRKT-POLE-S
Full‑Range Loudspeaker Accessories
BRKT‑POLE‑S, BRKT‑POLE‑L
Quick installation guide
3. Slowly slide the loudspeaker onto the pole mount.
4. Rotate the loudspeaker to set to the required rotation angle.
5. Tighten the set screw at the back of the enclosure, if available, without over tightening it.
Fig.9:
ZLX-8-G2
4. Tighten the bracket swivel arm nut using 17mm socket or
adjustable wrenches.
Technical data
BRKT-POLE-S Wall
mount bracket
8",10” 2-way
speaker
Color Black Black
Dimensions (H x W x
D) (mm)
Dimensions (H x W x
D) (in)
Shipping dimensions
(H x W x D) (mm)
Shipping dimensions
(H x W x D) (in)
Working load limit
1
(kg)
Working load limit
1
(lb)
250 mm x 115.8 mm
x 215.9 mm
9.84 in x 4.56 in x
8.50 in
295mm x 265mm x
85mm
11.61in x 10.43in x
3.35in
34.1kg 34.1kg
75lb 75lb
Weight (kg) 1.78 kg 2.02 kg
Weight (lb) 3.92 lb 4.45 lb
Shipping weight (kg) 1.94 kg 2.22 kg
Shipping weight (lb) 4.28 lb 4.89 lb
1
Maximum speaker weight than can be placed on the bracket
BRKT-POLE-L Wall
mount bracket
12”,15” 2-way
speaker
250 mm x 115.8 mm
x 317.5 mm
9.84 in x 4.56 in x
12.5 in
385mm x 265mm x
85mm
15.16in x 10.43in x
3.35in
Fig.12:
BRKT-POLE-L
Fig.13:
Bracket slot dimensions
Bosch Security Systems, LLC
130 Perinton Parkway
Fairport NY 14450
USA
www.electrovoice.com
© Bosch Security Systems, LLC, 2023
EU importer:
Bosch Sicherheitssysteme GmbH
Robert-Bosch-Platz 1
70839 Gerlingen
Germany
© Bosch Sicherheitssysteme GmbH, 2023
2023-07 | 02 | F.01U.409.930 | 202307121553