Electrosec DPS-3 User Manual

Page 1/2
2008-2 electrosec
R
electrosec
FEATURES
3 ampere 110-240 Vac. Free Input Voltage Output voltage that is adjusted 3-24 Vdc. from keypad Output voltage interval 1Vdc. 3x4 Marix Membrane Keypad 2-digit 7-segment Display that displays volt 2-digit 7-segment Display that displays ampere Automatic Digital Output Current Limitation Changable 4-digit program entrance code Restoring Factory Settings Code Function Stand-by waiting Audible warning when keys are pressed Green, red and yellow fonction leds Audible alarm warning in case of short circuit and overload current Protection against short circuit, overload current & thermal digital Power cable with socket for AC input Metal case, Dimension : W: 110mm. H:90mm D:190mm
Input voltage :
Output voltage :
Output voltage interval :
Output voltage precision :
Current measurement precision :
Regulator type :
Switching frequency :
Output current :
:
Protection overload :
Programmable current Limit :
Thermal protection :
Output leakage current :
Resting current :
Cooler :
Controller : Voltage Display : Current Display :
Control lights :
Audible warning :
Keypad :
Operation temprature :
Weight :
Protection against short circuit
110-240 Ac. 3-24 Vdc. Digital adjustment 1V. steps + % 1-3 +/- %5 Simple Switcher Step Down 52 Khz. Continue 2.6 A. Electronic Voltage closure
2.8 A. Max. Voltage closure Current that is + 300 Ma. + 125 C Max. 2mA.at 0V. 50 Ua (Stand-by). Aluminium 50x78x20 mm. Microprocessor with adj input 2 Digit 7 Segment red 2 Digit 7 Segment red Yellow, green, red 3mm led 5Vdc. Buzzer 3x4 Matrix
-10 + 60 C
2.200 Kg.
DPS-3
DIGITAL POWER SUPPLY
USER’S GUIDE
www.electrosec.com
TECHNICAL SPECIFICATIONS
Page 2/3
2008-2 electrosec
DPS-3 USER’S GUIDE
The factory setting for the digital adapter is adjusted in accordance with the 2.6 ampere that is the maximum current you can draw. You can reduce this current to the +300Ma. current limit depending on the importance of the equipments you use. This helps you protect the equipments that are connected to you. When the equipments are in the breakdown formation phase, they draw more current than they normally do. For the digital adapter to feel this, it needs current limit. For this, all the equipments that are going to be connected to the digital adapter must be put into operation mode and the current that is drawn in the current display must be under 2.3 ampere.
WHAT IS THE DIGITAL CURRENT LIMIT ?
ENABLE THE DIGITAL CURRENT LIMIT
1234 which is the factory setting code is entered. Then press the key # and digital current limitation is put into operation with the affirmation sound. From that moment on, the current that is 300Ma more than the current that is displayed on the screen can not be drawn. When it tries to draw, the output current is cut and the letters “oL” which is the Over Load symbol starts to blink on the Ampere screen together with the warning sound. This situation goes on until you press the * key. If the equipment does not turn back to its normal condition although you press * key, then there mus certainly be a problem with the equipments that are connected or extra current is being drawn from the digital adapter without your control. When you find this problem, you can operate the digital adapter again by pressing * key.
1234 which is the factory setting code is entered. Then press the key # and digital current limitation is put out of operation with the affirmation sound. From that moment on, from the digital adapter, you can draw 2.6 ampere which is the factory setting value. If more than 2.6 ampere current is drawn, the letters “oL” which is the Over Load symbol starts to blink together with the warning sound as in the case of digital current limitation. In this case you can operate the digital adapter again by pressing * key and diminishing the load that is connected to the digital adapter.
DIGITAL PROTECTION AGAINST SHORT CIRCUIT AND HEAT
Digital Adapter has protection against short circuit. In case of short circuit in the voltage in put, the letters “oL” which is the Over Load symbol starts to blink together with the warning sound as in the case of digital current limitation. In this case, you can operate the digital adapter again by checking equipment connections that are connected and the voltage output of the digital adapter and pressing * key. In addition to this, protection against thermal heat gets into service at 125 C
INSTALLATION & PROGRAMMING
You can operate the equipment by plugging the power cable, that is given together with the equipment, to the 220 Vac. input socket that is at the back of the equipment. While the equipment is opennig, the letters OP En appears on the screen that is on the front side, later on Voltage screen the number 12 appears and on the Ampere screen the numbers 00 appears. The numbers that is written on the voltage screen represent the voltage. The factory setting is adjusted as 12Vdc. You can draw 2.6 ampere.
DISABLE THE DIGITAL CURRENT LIMIT