3.0 Installation (cont...)
4.0 Maintenance, Repair & Disposal
l
Use only a damp cloth for cleaning and
wiping of the radiator which should be
switched off at this time.
l
When scrapping the radiator, follow the
regulations concerning the disposal of oil.
3.0 Installation
FLOOR
CONNECTION
l
The electrical installation must comply with
the local or national regulations.
l
The radiator must be connected to the
electrical supply, using a switched fused
spur with 3mm separation on all poles.
l
If the radiator is installed in a bathroom or
shower room, it must be protected with a
residual current device (RCD) with a rated
residual current not exceeding 30 mA.
Optional Extras
A (min) 135 135 135 135 135 135 135
A (max) 160 160 160 160 160 160 160
B (min) 101 254 508 762 812 1016 1219
B (max) 152 305 558 812 863 1066 1270
Length (mm) 400 550 800 1050 1100 1300 1500
Electrorad Digi-Line Single Panel (refer to figure 2)
C 135 205
D 90 163
Height (mm) 300 500
A 160 160 160 160 160 160 160 160 160 160
B 101 203 355 508 660 711 965 1016 1320 1727
Length (mm) 400 500 650 800 950 1000 1250 1300 1600 2000
Electrorad Digi-Line Double Panel (refer to figure 2)
C 135 205
D 90 163
Height (mm) 300 500
l
This product is splash resistant with an
IP44 rating. This must be considered when
installing in a location containing a bath or
shower, as defined by BS 7671.
l
The radiator may be positioned in zone 2
(figure 4) of the bathroom, in so far as no
operating controls (button, switch, etc.) are
in reach of persons in the bath or under
the shower.
l
NB: If the radiator is supplied with a
3 pin plug, then this should NOT be
installed in any bathroom zone.
FIXING
l
Mark out the distance between the brackets
and the positions for the screw holes as
shown in figure 2 and the dimension tables
at the top of page 7, and ensure the safety
clips are used (see figure 3).
Figure 2.
Figure 3.
Figure 1.
Min. 100mm
Min. 100mm
Min. 100mm
Step 1 Step 2
POSITIONING
l
The radiator must be positioned horizontally,
the right way up on the wall in order for it to
function correctly. Never switch the radiator
on in any other position as this will damage
the electrical element.
l
The radiator must be positioned according
to the applicable standards and the
minimum distances as specified in figure 1
should be carefully observed.
l
The radiator must not be located
underneath an electric socket.
Zone 1 Zone 2
Zone 2
Zone 0
OUTSIDE ZONES
3m
2.25m
0.6m
0.6m
Figure 4.
Safety Clip-on Brackets
RF Programmer + Touch E3
Electrorad Digi-Line radiators can be used
as a stand alone radiator. The radiator has
a built in radio frequency receiver which
can be used with an RF Programmer or
Touch E3. Please ask for more details.