Electronics Line EL-2614E, EL-2711P, EL-2711M User guide

EL2614E / EL-2711M / EL-2711P Wireless keyfob, Panic & Medical – Funkhandsender, Panik & Medizin - Émetteur radio, la panique et médecine - Radiozender, paniek & Medicine
Conrad No: 1276479/1276480/1276481
INTRODUCTION The EL-2711M-P and EL-2614E are keyfob transmitters. This product is a part of the Electronics Line Secuplace series, and operates together with the Secuplace alarm system. When you wish to know more about the complete system, its possibilities and its settings, then you can check out the installation manual or visit www.Electronics-Line.com.
WARNINGS
Do not expose the components of your systems to extremely high temperatures
or bright light sources.
In case of improper usage or if you have altered and repaired the product yourself, all guarantees expire. Electronics Line does not accept responsibility in the case of improper usage of the product or when the product is used for purposes other than specified. Electronics Line does not accept responsibility for additional damage other than covered by the legal product responsibility.
This product is not a toy. Keep out of reach of children.
The product should only be repaired or serviced by a qualified repairman.
Keep batteries out of the reach of children. Dispose of batteries as chemical waste. Never use old and new batteries or different types of batteries together. Remove the batteries when you are not using the system for a longer period of time. Check the polarity (+/-) of the batteries when inserting them in the product. Wrong positioning can cause an explosion.
Automatic switching devices provide comfort, but can also be dangerous. They can surprise people or can ignite clothing hanging over an electric heat source. Please be careful and take appropriate measures to avoid accidents.
REGISTRATION PROCEDURE To register keyfobs:
1.
From the Programming menu, select Devices, Keyfobs [912].
2.
Select the keyfob you want to register; the system initiates Registration mode.
3.
Press a button, making sure that the keyfob’s LED lights up when the button is pressed.
4.
Press the same button again. When Save? appears on the panel’s LCD display, press ./.
EL-2711M-P The EL-2711M-P is a one-button transmitter that generates a Medical Emergency alarm when pressed. The transmitter is water resistant and can be worn around the neck. Its large button makes it ideal for elderly or sight-impaired users.
When the battery is low, the EL-2711M-P’s LED flashes during transmission and a Low Battery signal is sent to the receiver.
EL2614E / EL-2711M / EL-2711P Wireless keyfob, Panic & Medical – Funkhandsender, Panik & Medizin - Émetteur radio, la panique et médecine - Radiozender, paniek & Medicine
Conrad No: 1276479/1276480/1276481
When either of these two indications are observed, replace the
EL-2614E
The EL-2614E is a four-button keyfob transmitter that offers a number of functions including arm, disarm and SOS Panic.
When the battery is low, the EL-2614E’s LED flashes during transmission and a Low Battery signal is sent to the receiver. When either of these two indications are observed, replace the batteries.
Figure B.11: EL-2614E
To replace the batteries:
1.
Insert a small screwdriver into the pry-off slot – see Figure B.12 Carefully twist the screwdriver to separate the front and back of the casing.
unit.
FigureB. EL-2711M-P
2.
Observing correct polarity, replace the batteries (3V lithium, size: CR1225).
3.
Close the casing making sure that the front and back click shut.
TECHNICAL DATA EL-2711M-P
Antenna: Frequency: Power: RFI Immunity: 40V/m Operating Temperature: 0 to 60°C Dimensions:
Built-in Whip
868.35MHz FM Non-replaceable battery
60 x 40 x 15mm
EL-2614E Antenna:
Frequency: Power:
Built-in Whip
868.35MHz FM 2 x 3V Lithium Battery Size CR1225
Current Consumption: 16mA (transmission)
2μA (standby) RFI Immunity: 40V/m Operating Temperature: 0 to 60°C Dimensions:
62 x 42 x 15mm
Figure B.12: Opening the
EL-2614E’s Casing
EL2614E / EL-2711M / EL-2711P Wireless keyfob, Panic & Medical – Funkhandsender, Panik & Medizin - Émetteur radio, la panique et médecine - Radiozender, paniek & Medicine
Conrad No: 1276479/1276480/1276481
5IN1561
International Headquarters:
Electronics Line 3000 Ltd.
14 Hachoma St., 75655 Rishon Le Zion, Israel Tel: (+972-3) 963-7777 Fax: (+972-3) 961-6584
All data is subject to change without prior notice techniques In no event shall Electronics Line be liable for an amount in excess of EL3K’s original selling price of this product, for any loss or damage whether direct, indirect, incidental, consequential or otherwise arising out of any failure of the product. Hereby, Electronics Line declares that this sensor/transmitter is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. Alle Daten können jederzeit ohne vorherige Ankündigung geändert werden. In keinem Fall haftet Electronics Line für einen Betrag von mehr als des ursprünglichen Kaufpreis des Produkts, für Verluste oder Schäden, ob direkte, indirekte, zufällige, Folge- oder die aus einer Fehlfunktion des Produkts entstandenen. Hiermit erklärt Electronics Line, dass sich dieses Gerät in Übereinstimmung mit den grundlegenden Anforderungen und den anderen relevanten Vorschriften der Richtlinie 1999/5/EG befindet. Hierbij verklaart Electronics Line dat het toestel dit apparaat in overeenstemming is met de essentiële eisen en de andere relevante bepalingen van richtlijn 1999/5/EG. Vollständige CE Erklärung unter www.secplan.de/ce Ces spécifications techniques sont sujettes à modifications sans avis préalable. Electronics Line (E.L) n'est en aucun cas responsable de l'augmentation du prix de vente du produit, de toute perte ou dommage direct, indirect, accidentel, consécutif ou provenant d'un défaut du produit. Par la présente Electronics Line déclare que l'appareil ce dispositif est conforme aux
exigences essentielles et aux autres dispositions pertinentes de la directive 1999/5/CE Specificaties kunnen wijzigen zonder voorafgaande melding hiervan. Hierbij verklaart Electronics Line dat het toestel dit apparaat in overeenstemming is met de essentiële eisen en de andere relevante bepalingen van richtlijn 1999/5/EG.
06/2011 5IN1561
Loading...