LCD GRAPHIC 122x32
INCL. CONTROLLER FOR 8 BIT BUS
blue-white: EA DIP122B-5NLW
Dimension 75 x 27 mm
6.2007
amber: EA DIP122J-5NLA
Dimension 75 x 27 mm
no more mounting
required
yellow/green: EA DIP122-5HNLED
Dimension 68 x 27 mm
FEATURES
* HIGH CONTRAST LCD DISPLAY AS STN AND FSTN
* CLASSIC LINE YELLOW/GREEN: EA DIP122-5HNLED
* OR BLUE-WHITE EA DIP122B-5NLW
* BUILT IN CONTROLLER PT6520 OR COMPATIBLE
* INTERFACE FOR 8 BIT DATA BUS
* POWER SUPPLY +2.7~5V / -6.3~-4V 800µA max.
* LED BACKLIGHT Y/G max. 150mA@+25°C
* LED BACKLIGHT AMBER AND WHITE max. 45mA@+25°C
* SOME MORE MODULES WITH SAME MECHANIC AND SAME PINOUT:
DOTMATRIX 1x8, 2x16, 4x20 AND 128x64, 240x128 WITH LARGER OUTLINE
* NO SCREWS REQUIRED: SOLDER ON IN PCB ONLY
* DETACHABLE VIA 9-PIN SOCKET EA B200-9 (2 PCS. REQUIRED)
* OPERATING TEMPERATURE RANGE 0~+50°C OR
* -20~+70°C OPERATING TEMP. WITH BUILT-IN TEMP. COMP. CIRCUIT
ORDERING INFORMATION
LCD GRAPHIC MODULE 122x32, WITH BACKLIGHT Y/G EA DIP122-5NLED
Y/G FOR -20~+70°C OPERATING TEMP. RANGE EA DIP122-5HNLED
BLUE-WHITE FOR -20~+70°C, LOW POWER EA DIP122B-5NLW
AMBER FOR -20~+70°C EA DIP122J-5NLA
9-PIN SOCKET, HEIGHT 4.3mm (2 PCS. REQUIRED) EA B200-9
HIGH-LEVEL-GRAPHICSCONTROLLER WITH RS-232C EA IC1520-1PGH
Lochhamer Schlag 17 · D-82166 Graefelfing · Phone +49-(0)89-8541991 · Fax +49-(0)89-8541721 · www.lcd-module.de · info@lcd-module.de

EA DIP122-5
Page 2
Specifications may be changed without
prior notice. Printing error reserved
PINOUT
Pin Symbol Level Function Pin Symbol Level Function
1 VSS L Power supply 0V (GND) 10 D3 H / L Display Data
2 VDD H Power supply +5V 11 D4 H / L Display Data
3 VEE - Contrast adjustment (-4 V) 12 D5 H / L Display Data
4 A0 H / L Command / Data 13 D6 H / L Display Data
5 R/W H / L H=Read, L=Write 14 D7 H / L Display Data, MSB
6 E1 H Enable left side 15 E2 H Enable right side
7 D0 H / L Display Data, LSB 16 RES L Reset
8 D1 H / L Display Data 17 A - LED Backlit+ (external RV !)
9 D2 H / L Display Data 18 C - LED Backlit -
CONTROLLER PT6520
Graphic modules of EA DIP122-5 series do have 2 controller PT6520 (or
compatible) built in: One for the left half of display and the other for the right
one. From 61 columns each 0..60 are used only.
ATTENTION
PT6520 do not have any character mode, so all character has
to be set by graphic. Many different fonts are optionally
available on disk with part numer EA DISKFONT1520.
A detailed description for all commands and interface timing
handling precautions!
you will find at the user manual for PT6520
*)
.
Instructions
A0 RD WR D7 D6 D5 D4 D3 D2 D1 D0
Display ON/OFF 0 1 0 1 0 1 0 1 1 1 0/1 Turns Display on or off. 0=OFF; 1=ON;
Display start line 0 1 0 1 1 0
Set page address 0 1 0 1 0 1 1 1 0
Display start
address (0 - 31)
Page
(0-3)
Set Column address 0 1 0 0 Column address (0 - 79) Sets display RAM column address.
O
R
N
E
/
O
F
F
0
S
E
T
0 0 0
Read Status 0 0 1
B
A
U
D
S
C
Y
Write display data 1 1 0 Write data Writes data into display RAM.
Read display data 1 0 1 Read data Reads data from display RAM.
Select ADC 0 1 0 1 0 1 0 0 0 0 0/1 0=CW output; 1=CCW output;
Static drive ON/OFF 0 1 0 1 0 1 0 0 1 0 0/1
Select duty 0 1 0 1 0 1 0 1 0 0 0/1 Select duty cycle. 0=1/16; 1=1/32;
Specifies RAM line corresponding to top
of display.
Sets display RAM page.
Read the following status:
BUSY:
ADC:
ON/OFF:
RESET:
Selects static driving operation.
0=Normal driving; 1=Static drive;
Function
1=Busy;
1=CW output;
1=Display off;
1=Being reset;
0=Ready;
0=CCW output;
0=Display on;
0=Normal;
Code
Read-Modify-Write 0 1 0 1 1 1 0 0 0 0 0 Read-modify-write ON
End 0 1 0 1 1 1 0 1 1 1 0 Read-modify-write OFF
Reset 0 1 0 1 1 1 0 0 0 1 0 Software reset.
*) http://www.lcd-module.de/eng/pdf/zubehoer/pt6520.pdf

Specifications may be changed without
prior notice. Printing error reserved
EA DIP122-5
Page 3
CONTRAST ADJUSTMENT
Contrast voltage for all displays of EA DIP122-5 series is typ. -4V. That means that for 5V power supply an
additional negative voltage of min. 4V is required.
Display modules for -20..+70°C (-5HNLED, -5NLW and -5NLA) are equipped with an on-board
temperature compensation. So there's no more need for contrast adjustment while operation anymore.
Furthermore these 3 displays are featured with a superfast STN/FSTN liquid that allows fast resonse even at
very low temperatures: typical response time at -20°C is 2 seconds only.
BACKLIGHT
Driving the backlight requires a current source or an external resistor for current limit. Please take care of
derating for t
>+25°C. Uf for yellow/green backlight is 3.9~4.2V, 2.2~2.6V (amber) and 3.0~3.6V for white
a
LED backlight.
Note: Do never drive backlight direct to 5V; immediately damage my happen !
YELLOW/GREEN - BLUE - AMBER
The blue-white display EA DIP122B-5NLW is best for indoor use with and without ambient light. Reading
the display requires a minimum of backlight with about 15mA.
The yellow/green version EA DIP122-5NLED is especially designed for 24-hour or outdoor applications.
These displays do provide best contrast for all ambient illuminations, even with direct sunlight. No need to
say that these display can be read in darkness when LED backlight is switched on.
This is same for the amber backlighted version EA DIP122J-5NLA.

EA DIP122-5
Page 4
Specifications may be changed without
prior notice. Printing error reserved
all dimensions are in mm
Note:
In general LC display are not suitable for wave
soldering and reflow soldering process. An ambient
temperature above 80°C may destroy the display.
ATTENTION
handling precautions!
DIMENSIONS
Lochhamer Schlag 17 · D-82166 Graefelfing · Phone +49-(0)89-8541991 · Fax +49-(0)89-8541721 · www.lcd-module.de · info@lcd-module.de