ELECTRONIC ASSEMBLY EA TFT070-84ANN Datasheet

Zeppelinstrasse 19 D-82205 Gilching Fon +49-8105-778090
CUSTOMER :
MODULE NO.: EA TFT070-84ANN
APPROVED BY:
info@lcd-module.de
http://www.lcd-module.de
( FOR CUSTOMER USE ONLY )
SALES BY APPROVED BY CHECKED BY PREPARED BY
ISSUED DATE: 2019/02/01
PCB VERSION: DATA:
Zeppelinstrasse 19 D-82205 Gilching Fon +49-8105-778090
Content
1.Summary
2.General Specification
3.Absolute Maximum Ratings
4.Electrical Characteristics
5.DC Characteristics
6.AC Characteristics
info@lcd-module.de
http://www.lcd-module.de
7.Optical Characteristics
8.Interface
9.Block Diagram
10.Reliability
11.Contour Drawing
EA TFT070-84ANN
Page 2 of 16
Zeppelinstrasse 19 D-82205 Gilching Fon +49-8105-778090
info@lcd-module.de
http://www.lcd-module.de
1.Summary
This technical specification applies to 7.0’ color TFT-LCD panel. The 7.0’ color TFT-LCD panel is designed for camcorder, digital camera application and other electronic products which require high quality flat panel displays. This module follows RoHS.
1.1. Accessories
ZIF connector for display, bottom contact EA WF050-40S ZIF connector for display, top contact EA WF050-40ST
EA TFT070-84ANN
Page 3 of 16
Zeppelinstrasse 19 D-82205 Gilching Fon +49-8105-778090
info@lcd-module.de
2.General Specifications
Item Dimension Unit
Size 7.0 inch
Dot Matrix 800 x RGBx480(TFT) dots
Module dimension 165.0(W) x 100(H) x 5.8(D) mm
Active area 154.08 x 85.92 mm
Dot pitch 0.1926 x 0.179 mm
LCD type TFT, Normally White, Transmissive
http://www.lcd-module.de
View Direction 12 o’clock
Gray Scale Inversion Direction 6 o’clock
Backlight Type LED, Normally White
With /Without TP Without TP
Surface Anti-Glare
*Color tone slight changed by temperature and driving voltage.
EA TFT070-84ANN
Page 4 of 16
Zeppelinstrasse 19 D-82205 Gilching Fon +49-8105-778090
info@lcd-module.de
http://www.lcd-module.de
3.Absolute Maximum Ratings
Item Symbol Min Typ Max Unit
Operating Temperature TOP -20
Storage Temperature TST -30
Note: Device is subject to be damaged permanently if stresses beyond those absolute maximum ratings listed above
1. Temp. 60, 90% RH MAX. Temp.60, Absolute humidity shall be less than 90% RH at 60
+70
+80
EA TFT070-84ANN
Page 5 of 16
Zeppelinstrasse 19 D-82205 Gilching Fon +49-8105-778090
info@lcd-module.de
http://www.lcd-module.de
4.Electrical Characteristics
4.1. Operating conditions:
Item Symbol Min Typ Max Unit
Supply Voltage For Logic VCC 3.0 3.3 3.6 V Note 1
Power Supply For Current VCC =3.3V 110 165 mA
Note 1 : This value is test for Vcc=3.3V , Ta=25 only
4.2. LED driving conditions
Parameter Symbol Min. Typ. Max. Unit Remark LED current - - 180 - mA ­Power Consumption - 1620 - 1890 mW ­LED voltage VLED+ 9.0 - 10.5 V Note 1 LED Life Time - - 50,000 - Hr Note 2,3,4
Note 1 : There are 1 Groups LED
Remark
Note 2 : Ta = 25 Note 3 : Brightness to be decreased to 50% of the initial value
Note 4 : The single LED lamp case
EA TFT070-84ANN
Page 6 of 16
Zeppelinstrasse 19 D-82205 Gilching Fon +49-8105-778090
info@lcd-module.de
5.DC CHARATERISTICS
Rating
Parameter Symbol
Min Typ Max
Low level input voltage VIL 0 - 0.3VCC V
High level input voltage VIH 0.7VCC - VCC V
http://www.lcd-module.de
Unit Condition
EA TFT070-84ANN
Page 7 of 16
Zeppelinstrasse 19 D-82205 Gilching Fon +49-8105-778090
info@lcd-module.de
6.AC CHARATERISTICS
6.1. AC Electrical Characteristics
Signal Symbol Min Typ Max Unit
HS setup time Thst 8 - - ns HS hold time Thhd 8 - - ns VS setup time Tvst 8 - - ns VS hold time Tvhd 8 - - ns Data setup time Tdsu 8 - - ns Data hole time Tdhd 8 - - ns VCC Power On Slew rate TPOR - - 20 ms RESET pulse width TRst 1 - - ms DCLK cycle time Tcoh 20 - - ns DCLK pulse duty Tcwh 40 50 60 %
6.2. Input Clock and Data Timing Diagram
http://www.lcd-module.de
EA TFT070-84ANN
Page 8 of 16
Zeppelinstrasse 19 D-82205 Gilching Fon +49-8105-778090
6.3. Timing
info@lcd-module.de
Val ue s
Item Symbol
Unit Remark
Min. Typ. Max.
CLK Frequency (DCLK)
Horizontal Display Area thd - 800 - CLK
One Horizontal Line th 862 1056 1200 CLK
HS pulse width thpw 1 - 40 CLK
HS Blanking thb 46 46 46 CLK
HS Front Porch thfp 16 210 354 CLK
Vertical Display Area tvd - 480 - TH
VS period time tv 510 525 650 TH
VS pulse width tvpw 1 - 20 TH
VS Blanking tvb 23 23 23 TH
VS Front Porch tvfp 7 22 147 TH
6.4. Data Input Format
fclk 26.4 33.3 46.8 MHz
http://www.lcd-module.de
Fig. Horizontal input timing diagram
Fig. Vertical input timing diagram
EA TFT070-84ANN
Page 9 of 16
Zeppelinstrasse 19 D-82205 Gilching Fon +49-8105-778090
info@lcd-module.de
7.Optical Characteristics
Item Symbol Condition. Min Typ. Max. Unit Remark
Response time
Contrast ratio CR
Color Chromaticity White
Viewing angle
(Gray Scale Inversion
Direction)
Brightness - - 350 460 -
Hor.
Ver.
Tr Tf - 15 30 .ms
viewing angle Wx Wy 0.28 0.33 0.38 ­ΘR ΘL 60 70 ­ΦT 40 50 ­ΦB 60 70 -
Ta=25 ±2, IL=180mA Note 1: Definition of viewing angle range
θ=0°Φ=0°
At optimized
θ=0°Φ=0
CR10
- 10 20 .ms
400 500 - - Note 4
0.26 0.31 0.36 -
60 70 -
http://www.lcd-module.de
Note 3
Note 2,5,6
Deg. Note 1
Center of
2
cd/m
display
Fig. 7.1. Definition of viewing angle Note 2: Test equipment setup: After stabilizing and leaving the panel alone at a driven temperature for 10 minutes, the measurement should be executed. Measurement should be executed in a stable, windless, and dark room. Optical specifications are measured by Topcon BM-7orBM-5 luminance meter 1.0° field of view at a distance of 50cm and normal direction.
EA TFT070-84ANN
Page 10 of 16
Zeppelinstrasse 19 D-82205 Gilching Fon +49-8105-778090
info@lcd-module.de
http://www.lcd-module.de
Fig. 8.2. Optical measurement system setup Note 3: Definition of Response time: The response time is defined as the LCD optical switching time interval between “White” state and “Black” state. Rise time, Tr, is the time between photo detector output intensity changed from 90%to 10%. And fall time, Tf, is the time between photo detector output intensity changed from 10%to 90%
Display
Data
100%
90%
Black(TFT ON) White(TFT OFF)W h ite (T F T O F F )
10%
0%
Note 4: Definition of contrast ratio: The contrast ratio is defined as the following expression.
Contrast ratio (CR ) =
Luminance measured when LCD on the "White" state Luminance measured when LCD on the "Black" state
Note 5: White Vi = Vi50 ± 1.5V Black Vi = Vi50 ± 2.0V “±” means that the analog input signal swings in phase with VCOM signal. “±” means that the analog input signal swings out of phase with VCOM signal. The 100% transmission is defined as the transmission of LCD panel when all the input terminals of module are electrically opened.
Note 6: Definition of color chromaticity (CIE 1931) Color coordinates measured at the center point of LCD
Note 7: Measured at the center area of the panel when all the input terminals of LCD panel are electrically opened.
EA TFT070-84ANN
Page 11 of 16
Zeppelinstrasse 19 D-82205 Gilching Fon +49-8105-778090
info@lcd-module.de
8.Interface
8.1. LCM PIN Definition
Pin Symbol Function Remark
1 VLED- Backlight ground 2 VLED+ Power supply for backlight 3 GND Power ground 4 VCC Power for Digital Circuit 5 R0 Red data(LSB) Note 1 6 R1 Red data Note 1 7 R2 Red data 8 R3 Red data 9 R4 Red data 10 R5 Red data 11 R6 Red data 12 R7 Red data(MSB) 13 G0 Green data(LSB) Note 1 14 G1 Green data Note 1 15 G2 Green data 16 G3 Green data 17 G4 Green data 18 G5 Green data 19 G6 Green data 20 G7 Green data(MSB) 21 B0 Blue data(LSB) Note 1 22 B1 Blue data Note 1 23 B2 Blue data 24 B3 Blue data 25 B4 Blue data 26 B5 Blue data 27 B6 Blue data 28 B7 Blue data(MSB) 29 GND Power Ground 30 CLK Sample clock Note 2 31 R/L Right /Left selection Note 3,4 32 Hsync Horizontal Sync Input 33 Vsync Vertical Sync Input 34 NC No connection 35 U/D Up/down selection Note 3,4 36 RESET Global reset pin. 37 NC No connection 38 NC No connection 39 NC No connection 40 NC No connection
http://www.lcd-module.de
EA TFT070-84ANN
Page 12 of 16
Zeppelinstrasse 19 D-82205 Gilching Fon +49-8105-778090
info@lcd-module.de
http://www.lcd-module.de
Note 1: When input 18 bits RGB data, the two low bits of R,G and B data must be grounded. Note 2: Data shall be latched at the falling edge of CLK. Note 3: Selection of scanning mode
Setting of scan
U/D R/L
L
H L Down to up, right to left L L Up to down, right to left H H Down to up, left to right
H Up to down, left to right
Scanning direction
Note 4: Definition of scanning direction. Refer to the figure as below:
Up
Left Right
Down
EA TFT070-84ANN
Page 13 of 16
Zeppelinstrasse 19 D-82205 Gilching Fon +49-8105-778090
9.Block Diagram
CLK
R0~R7
G0~G7
B0~B7
Vsync,Hsync
RESET
VCC
R/L,U/D
GND
INPUT CONNECTOR
CONTROLLER
TIMING
info@lcd-module.de
http://www.lcd-module.de
SCAN DRIVER IC
TFT LCD
PANEL
DATA DRIVER IC
VLED+ VLED-
LED CONNECTOR BACKLIGHT UNIT
EA TFT070-84ANN
Page 14 of 16
Zeppelinstrasse 19 D-82205 Gilching Fon +49-8105-778090
info@lcd-module.de
http://www.lcd-module.de
10.Reliability
Content of Reliability Test (Wide temperature, -20℃~70℃)
Environmental Test
Test Item Content of Test Test Condition Note
High Temperature storage
Low Temperature storage
High Temperature Operation
Low Temperature Operation
High Temperature/ Humidity Operation
Thermal shock resistance
Vibration test Endurance test applying the vibration during
Static electricity test Endurance test applying the electric stress to the
Note1: No dew condensation to be observed. Note2: The function test shall be conducted after 4 hours storage at the normal Temperature and humidity after remove from the test chamber. Note3: The packing have to including into the vibration testing.
Endurance test applying the high storage temperature for a long time.
Endurance test applying the low storage temperature for a long time.
Endurance test applying the electric stress (Voltage & Current) and the thermal stress to the element for a long time. Endurance test applying the electric stress under low temperature for a long time.
The module should be allowed to stand at 60 ,90%RH max
The sample should be allowed stand the following 10 cycles of operation
-20℃ 25℃ 70
30min 5min 30min 1 cycle
transportation and using.
terminal.
80 200hrs
-30 200hrs 70 200hrs
-20 200hrs 60,90%RH 96hrs
-20/70 10 cycles
Total fixed amplitude : 15mm Vibration Frequency : 10~55Hz One cycle 60 seconds to 3 directions of X,Y,Z for Each 15 minutes VS=±600V(contact), ±800v(air), RS=330Ω
CS=150pF 10 times
2
1,2
——
1
1,2
——
3
——
EA TFT070-84ANN
Page 15 of 16
Zeppelinstrasse 19 D-82205 Gilching Fon +49-8105-778090
11.Contour Drawing
Component Area
4
1
XLYD XRYU
info@lcd-module.de
http://www.lcd-module.de
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40
1 2 3 4 5 6 7 8 9
VLED-
VLED+
GND VCC
R0 R1 R2 R3 R4 R5 R6 R7 G0 G1 G2 G3 G4 G5 G6 G7 B0 B1 B2 B3 B4 B5 B6
B7
GND CLK
R/L Hsync Vsync
NC
U/D
RESET
NC
NC
NC
NC
The non-specified tolerance of dimension is 0.3mm.
EA TFT070-84ANN
Page 16 of 16
Loading...