Zeppelinstrasse 19 D-82205 Gilching Fon +49-8105-778090
SPECIFICATION
CUSTOMER :
MODULE NO.: EA TFT057-32ANN
APPROVED BY:
info@lcd-module.de
http://www.lcd-module.de
( FOR CUSTOMER USE ONLY )
SALES BY APPROVED BY CHECKED BY PREPARED BY
ISSUED DATE: 2018/06/18
PCB VERSION: DATA:
Page 2
Zeppelinstrasse 19 D-82205 Gilching Fon +49-8105-778090
Content
1.Summary
2.General Specification
3.Absolute Maximum Ratings
4.Electrical Characteristics
5.DC Characteristics
6.AC Characteristics
info@lcd-module.de
http://www.lcd-module.de
7.Optical Characteristics
8.Interface
9.Block Diagram
10.Reliability
11.Contour Drawing
EA TFT057-32ANN
Page 2 of 16
Page 3
Zeppelinstrasse 19 D-82205 Gilching Fon +49-8105-778090
info@lcd-module.de
http://www.lcd-module.de
1.Summary
This technical specification applies to 5.7’ color TFT-LCD panel. The 5.7’ color TFT-LCD panel
is designed for camcorder, digital camera application and other electronic products which
require high quality flat panel displays. This module follows RoHS.
1.1. Accessories
ZIF connector for display, bottom contact EA WF050-40S
ZIF connector for display, top contact EA WF050-40ST
EA TFT057-32ANN
Page 3 of 16
Page 4
Zeppelinstrasse 19 D-82205 Gilching Fon +49-8105-778090
info@lcd-module.de
2.General Specifications
Item Dimension Unit
Size 5.7 inch
Dot Matrix 320 x RGBx240(TFT) dots
Module dimension 141.12(W) x 101.55(H) x 6.5(D)(MAX) mm
Active area 115.2 x 86.40 mm
Dot pitch 0.12 x 0.36 mm
LCD type TFT, Normally White, Transmissive
http://www.lcd-module.de
View Direction 12 o’clock
Gray Scale Inversion Direction 6 o’clock
Backlight Type LED,Normally White
With /Without TP Without TP
Surface Glare
*Color tone slight changed by temperature and driving voltage.
EA TFT057-32ANN
Page 4 of 16
Page 5
Zeppelinstrasse 19 D-82205 Gilching Fon +49-8105-778090
info@lcd-module.de
http://www.lcd-module.de
3.Absolute Maximum Ratings
Item Symbol Min Typ Max Unit
Operating Temperature TOP -20
Storage Temperature TST -30
Note: Device is subject to be damaged permanently if stresses beyond those absolute maximum ratings
listed above
1. Temp. ≦60℃, 90% RH MAX. Temp.>60℃, Absolute humidity shall be less than 90% RH at 60℃
Ambient Tem. vs Alloeable Forward Curren
-
-
40
+70
+80
℃
℃
30
20
10
0
020406080100
Alloeable Forward Current IF(mA)
Ambient Temperature(oC)
EA TFT057-32ANN
Page 5 of 16
Page 6
Zeppelinstrasse 19 D-82205 Gilching Fon +49-8105-778090
info@lcd-module.de
http://www.lcd-module.de
4.Electrical Characteristics
4.1. Operating conditions:
Item Symbol ConditionMin Typ Max Unit
Supply Voltage For Logic VCC
Supply Current ICC VCC=3.3V
4.2. LED driving conditions
Parameter Symbol Min. Typ. Max. Unit Remark
LED current - 140 - mA
Power Consumption 1260 1470 mW
LED voltage VBL+ 9.0 10.5 V Note 1
LED Life Time 50,000 Hr Note 2,3,4
-
3.0 3.3 3.6 V
-
140 210 mA
Note 1 : There are 1 Groups LED
Note 2 : Ta = 25
Note 3 : Brightness to be decreased to 50% of the initial value
Note 4 : The single LED lamp case.
A
K
EA TFT057-32ANN
Page 6 of 16
Page 7
Zeppelinstrasse 19 D-82205 Gilching Fon +49-8105-778090
info@lcd-module.de
5.DC CHARATERISTICS
Rating
Parameter Symbol
Min Typ Max
Low level input voltage VIL0 - 0.3VCC V
High level input voltage VIH0.7VCC - VCC V
http://www.lcd-module.de
Unit Condition
EA TFT057-32ANN
Page 7 of 16
Page 8
Zeppelinstrasse 19 D-82205 Gilching Fon +49-8105-778090
info@lcd-module.de
http://www.lcd-module.de
6.AC CHARATERISTICS
6.1. 24-bits parallel RGB Interface
AC Timing Characteristics
Signal ltem Symbol Min. Typ. Max. Unit
Frequency Dclk - 6.4 - MHZ
Dclk
Data
Hsync
Vsync
Back-Porch
Display Period Tvd - 240 - TH
Front-Porch
AC Timing Diagrams
High time Tch - 78 - ns
Low time Tcl - 78 - ns
Setup time Tds 12 - - ns
Hold time Tdh 12 - - ns
Period TH - 408 - DCLK
Pulse Width Thp - 30 - DCLK
Back-Porch Thb - 38 - DCLK
Display Period Thd - 320 - DCLK
Front-Porch Thf - 20 - DCLK
Period
Pulse Width Tvp 1 3 5 TH
NTSC
PAL 312.5 -
NTSC
PAL 23
NTSC
PAL 46 .5
TV -
Tvb -
Tvf -
262.5 -
15
4.5
- TH
- TH
DCLK
EA TFT057-32ANN
Page 8 of 16
Page 9
Zeppelinstrasse 19 D-82205 Gilching Fon +49-8105-778090
info@lcd-module.de
http://www.lcd-module.de
EA TFT057-32ANN
Page 9 of 16
Page 10
Zeppelinstrasse 19 D-82205 Gilching Fon +49-8105-778090
info@lcd-module.de
7.Optical Characteristics
Item SymbolCondition. Min Typ. Max. Unit
Response time
Contrast ratio CR
Color Chromaticity White
Viewing angle
(Gray Scale Inversion
Direction)
Ta=25±2 ℃, IL=140mA
Note 1: Definition of viewing angle range
Brightness - - 400 500 cd/m2
Hor.
Ve r.
Tr
Tf - 35 50 .ms
Wx
Wy 0.3190.3490.379
ΘR
ΘL
ΦT
ΦB
θ=0˚、Φ=0˚
At optimized
viewing angle
θ=0˚、Φ=0
CR≧10
- 15 30 .ms
150 250 - - Note 4,5
0.2820.3120.342
60 70
60 70
40 50
60 70
http://www.lcd-module.de
Remark
Note 3,5
Note 2,6,7
Deg. Note 1
Center of
display
Fig.8.1. Definition of viewing angle
Note 2: Test equipment setup:
After stabilizing and leaving the panel alone at a driven temperature for 10 minutes, the measurement
should be executed. Measurement should be executed in a stable, windless, and dark room. Optical
specifications are measured by Topcon BM-7orBM-5 luminance meter 1.0° field of view at a distance
of 50cm and normal direction.
EA TFT057-32ANN
Page 10 of 16
Page 11
Zeppelinstrasse 19 D-82205 Gilching Fon +49-8105-778090
info@lcd-module.de
http://www.lcd-module.de
Fig. 8.2. Optical measurement system setup
Note 3: Definition of Response time:
The response time is defined as the LCD optical switching time interval between “White” state and
“Black” state. Rise time, Tr, is the time between photo detector output intensity changed from 90%to
10%. And fall time, Tf, is the time between photo detector output intensity changed from 10%to 90%
Display
Data
100%
90%
Black(TFT ON)W hite(TFT OFF)W hite(T FT O F F)
10%
0%
Note 4: Definition of contrast ratio:
The contrast ratio is defined as the following expression.
Contrast ratio (CR) =
Luminance measured when LCD on the "White" state
Luminance measured when LCD on the "Black" state
Note 5: White Vi = Vi50 ± 1.5V
Black Vi = Vi50 ± 2.0V
“±” means that the analog input signal swings in phase with VCOM signal.
“±” means that the analog input signal swings out of phase with VCOM signal.
The 100% transmission is defined as the transmission of LCD panel when all the input terminals of
module are electrically opened.
Note 6: Definition of color chromaticity (CIE 1931)
Color coordinates measured at the center point of LCD
Note 7: Measured at the center area of the panel when all the input terminals of LCD panel are
electrically opened.
EA TFT057-32ANN
Page 11 of 16
Page 12
Zeppelinstrasse 19 D-82205 Gilching Fon +49-8105-778090
info@lcd-module.de
8.Interface
8.1. LCM PIN Definition
Pin Symbol Function Remark
1 NC No connection
2 NC No connection
3 GND System ground pin of the IC. Connect to system ground.
4 VCC Power Supply
5 R0 Red Data bit(LSB)
6 R1 Red Data bit
7 R2 Red Data bit
8 R3 Red Data bit
9 R4 Red Data bit
10 R5 Red Data bit
11 R6 Red Data bit
12 R7 Red Data bit (MSB)
13 G0 Green Data bit(LSB)
14 G1 Green Data bit
15 G2 Green Data bit
16 G3 Green Data bit
17 G4 Green Data bit
18 G5 Green Data bit
19 G6 Green Data bit
20 G7 Green Data bit (MSB)
21 B0 Blue Data bit(LSB)
22 B1 Blue Data bit
23 B2 Blue Data bit
24 B3 Blue Data bit
25 B4 Blue Data bit
26 B5 Blue Data bit
27 B6 Blue Data bit
28 B7 Blue Data bit (MSB)
29 GND
30 CLK Dot data clock
31 L/R Shift direction of device internal shift register control. Note2,3
32 Hsync Horizontal sync signal Note1
33 Vsync Vertical sync signal Note1
34 DE Data Enable signal Note1
35 U/D Up/down selection Note2,3
36 RESET Hardware reset
37 NC No connection
38 NC No connection
39 NC No connection
40 NC No connection
System ground pin of the IC. Connect to system
ground.
http://www.lcd-module.de
EA TFT057-32ANN
Page 12 of 16
Page 13
Zeppelinstrasse 19 D-82205 Gilching Fon +49-8105-778090
For digital 24Bit RGB input data format, both SYNC mode and DE mode are supported. If DE signal is fixed low,
SYNC mode is used. Otherwise,DE mode is used. Suggest used SYNC mode!!
info@lcd-module.de
http://www.lcd-module.de
ModeD[23:16] D[15:8]D[7:0]IHSIVSDEN
HSYNCVSYNC
24 bit RGBR[7:0]G[7:0]B[7:0]
Note 2: Selection of scanning mode
Setting of scan control input Scanning direction
U/D L/R
GND VCC Up to down, left to right
VCC GND Down to up, right to left
GND GND Up to down, right to left
VCC VCC Down to up, left to right
Note 3: Definition of scanning direction.Refer to the figure as below:
Floating if
not used
Floating if
not used
DE signal is fixed low
for SYNC mode
DE for DE Mode
EA TFT057-32ANN
Page 13 of 16
Page 14
Zeppelinstrasse 19 D-82205 Gilching Fon +49-8105-778090
9.Block Diagram
LCD Driver Chip (COG)
R0~R7,G0~G7,B0~B7
HSYNC, VSYNC
Data C LK ,D E
RESET
Power supply
L/R,U/D
D ata C L K
Power supply
VCC
Pa ralle- 24 bit RG B
VS
HS
DE
FPC
info@lcd-module.de
Source +Gate
Driver
Grayscale
Manipulation
Voltage
TCON
VCON
Charge pump
http://www.lcd-module.de
5.7"
320(RGB)x240
RESET
L/R,U/D
Backlight LED
LED_Anode , LED_Cathode
B/L
EA TFT057-32ANN
Page 14 of 16
Page 15
Zeppelinstrasse 19 D-82205 Gilching Fon +49-8105-778090
info@lcd-module.de
http://www.lcd-module.de
10.Reliability
Content of Reliability Test (Wide temperature, -20℃~70℃)
Environmental Test
Test Item Content of Test Test Condition Note
High Temperature
storage
Low Temperature
storage
High Temperature
Operation
Low Temperature
Operation
High Temperature/
Humidity Operation
Thermal shock
resistance
Vibration test Endurance test applying the vibration during
Static electricity test Endurance test applying the electric stress to the
Note1: No dew condensation to be observed.
Note2: The function test shall be conducted after 4 hours storage at the normal
Temperature and humidity after remove from the test chamber.
Note3: The packing have to including into the vibration testing.
Endurance test applying the high storage
temperature for a long time.
Endurance test applying the low storage
temperature for a long time.
Endurance test applying the electric stress
(Voltage & Current) and the thermal stress to the
element for a long time.
Endurance test applying the electric stress under
low temperature for a long time.
The module should be allowed to stand at 60
℃,90%RH max
The sample should be allowed stand the
following 10 cycles of operation
-20℃ 25℃ 70℃
30min 5min 30min
1 cycle
transportation and using.
terminal.
80℃
200hrs
-30℃
200hrs
70℃
200hrs
-20℃
200hrs
60℃,90%RH
96hrs
-20℃/70℃
10 cycles
Total fixed
amplitude : 15mm
Vibration Frequency :
10~55Hz
One cycle 60 seconds
to 3 directions of
X,Y,Z for Each 15
minutes
VS=±600V(contact),
±800v(air),
RS=330Ω
CS=150pF
10 times
2
1,2
——
1
1,2
——
3
——
EA TFT057-32ANN
Page 15 of 16
Page 16
Zeppelinstrasse 19 D-82205 Gilching Fon +49-8105-778090