Electrolux T5190 User Manual

Features and benefits
Compass Pro – Large display and one control knob for easy program selection
- Language selection
- Quick selection and option buttons for the most frequently used drying programs and options
- Drying program packages optimized for Economy, Care and Time and option buttons for selection of dryness
- Service program for adjustment of parameters
- USB connection
• High productivity – 2 full loads per hour
• Low energy consumption for optimal efficiency
• Reversable door hanging for a convenient laundry flow
• Easy access to vital parts from front and rear for simple servicing
• The coin version with Ecopower to avoid over drying of the garments and get a lower energy consumption
• Residual Moisture Control for an accurate drying result and a low energy consumption
• Reversing drum for less tangling of large items
®
microprocessor offers:
PROFESSIONAL LAUNDRY
Tumble dryer
T5190
Main options
• Stainless steel front
• Stainless steel drum
• Payment: coinmeter with Ecopower, chipcard reader, CP connection
• Stainless steel base frame
• Separate condense system
• Fresh air intake
Main specifications
Rated capacity, filling factor 1:18 kg/lb filling factor 1:22 kg/lb Drum volume litre Drum diameter mm Heating, electric kW gas BTU/h (kW)
Consumption data*
Total time full load min Energy consumption full load kWh Evaporation g/min Energy kWh/litre water evaporated kWh/l
* At rated capacity 100% cotton load at 50% initial moisture dryed to 0%.
Certified in accordance with ISO 9001 and ISO 14001 and approved IP X4.
T5190
10.6/23
6.0/8.0 20500/27300 (6.0/8.0)
6.0 kW 8.0 kW Gas 6.0 kW Gas 8.0 kW
35 27 36 29
3.45 3.53 3.67 3.74 102 129 106 131
0.92 0.94
Images shown are a representation of the product only and variations may occur.
C
Electrical connections
Heating Main voltage Heating Total Recommended alternative power power fuse Hz kW kW A
220-240V 1 ~ 50/60 6.0/8.0 6.3/8.3 35/50
Electric heated 220-230V 3 ~ 50/60 6.0/8.0 6.3/8.3 20/25 240V 3 ~ 50/60 6.0/8.0 6.3/8.3 16/25 380-415V 3 ~ 50/60 6.0/8.0 6.3/8.3 10/16 440/480V 3 ~ 60 6.0/8.0 6.3/8.3 10/16
220-480V 1/3 ~ 50/60 - 0.3 10
Gas heated
A
1
Gas and air connections
Gas ISO 7/1-R Gas pressure Natural gas Pa mbar Propane Pa mbar Air outlet ø mm Evacuated air 6.0 kW m
8.0 kW Pressure drop 6.0 kW Max. Pa
8.0 kW
Sound levels
Airborne sound level dB(A)
Heat emission
% of installed power, max
Shipping data*
Weight net, kg
Shipping volume m
Dimensions in mm
A Width B(a) Depth (Gas) B(b) Depth (El) B(c) Depth C Height D E F G H I J
1 Operating panel 2 Door opening ø 400 mm 3 Electrical connection 4 Gas connection 5 Exhaust connection
* Average data. Crated weight/shipping volume depends on configuration. Please contact logistics for exact measures.
2800-5000
3
/h
3
T5190
1/2”
2000
20
30
125 270 290 380 350
68
15
99
0.83
721 778 759
684
1114
404
45
180
88 113 79
561
2
D
Front
B(a)
B(b)
E
F
3
Rear, El
I
Side view
H
B(c)
G
www.electrolux.com/professional
Share more of our thinking at www.electrolux.com
J
4
Rear, Gas
5
Art. No. 438919515EN/2016.03.31
We reserve the right to alter specifications without notice.
Loading...