Electrolux RCDR4M33U User Manual

Page 1
Identification:
Technical Bulletin no:
Date: Issuer: Factory:

Subject

Model
Problem
Action in Factory
D02-D03-D04-D05-D06
CGX2006-01 (page 1 of 4), 3rd ed.
24 July 20006 R. Sartor (DWS Customer Support) DW Vallenoncello - Italy

Rinse Pump in UC, UW, HT, PW and Old RT

Undercounter LS6E / WT30E with atmospheric boiler,
Utensils Washer LU7 / WTU40 with atmospheric boiler,
Hood Type LS9 / WT55 with atmospheric boiler,
Hood Type LS10EA-14EA / WT65E
Pot&Pan Washer PW1M-2M / WT830M-850M / WT830EA-850EA
Rack Type RT140-190-270 Eco and Ecoplus (with Duo Rinse)
Rack type WT100-140-150-190-200-270 Basic, Eco and Ecoplus (with Duo Rinse)
Sometime water leakage overnight.
Some pumps leak from shaft sealing and some worked without water (burning the sealing)
From serial number 60800001 we have introduced new rinse pumps FIR5213 with grey thermosetting (BCM) shell and cross through screws with self­locking nut instead of 049310 (and relevant pumps FIR4213 with different voltage supply) with white thermoplastic shell and self-tapping screws. Thermosetting material is more chemicals and high temperature proof than thermoplastic material.
ELECTROLUX PROFESSIONAL SPA MAILING ADDRESS TELEPHONE WEBSITE VAT NO.
VIA SEGALUZZA, 30 33170 PORDENONE - ITALY
OFFICE ADDRESS TELEFAX E-MAIL ADDRESS
VIA SEGALUZZA, 30 33170 PORDENONE - ITALY
++39 0434 380650 www.electrolux.com 00072220932
++39 0434 380643 ++39 0434 385646
riccardo.sartor@electrolux.it
Page 2
old code
(FIR 4213)
049310
049612
049812
049813
0L0020
n.a.
n.a.
049965 0L0421
new rinse
pump
prod. code
(see rating plate)
611631300
611632400
611631500
611632500
611631800
611632600
611631900
611632800
611631600
611633000
611632900
611632700
611631700 611632000
new
code
(FIR 5213)
0L1079
0L1104
0L1100
0L1111
0L1103 0L1112
0L1101 0L1109
0L1099 0L1110
0L1114
0L1113
0L1102 0L1098
Voltage
characteristics
supply
[V]
Short
rotor/stator
NOT for RT
Long rotor/stator
220/240 50
90° outlet
For Rack Type
Short
rotor/stator
NOT for RT
Long rotor/stator
220/240 60
90° outlet
For Rack Type
Long rotor/stator 6.3 Long rotor/stator
90° outlet
400 50 0.28
For Rack Type
Long rotor/stator 6.3 Long rotor/stator
90° outlet
440 60 0.28
For Rack Type
Long rotor/stator 6.3 Long rotor/stator
90° outlet
200 60 0.28
For Rack Type
Long rotor/stator
90° outlet
440 50 0.28 6.3 2800
For Rack Type
Long rotor/stator
90° outlet
400 60 0.28 6.3 3400
For Rack Type
Long rotor/stator 200 50 0.28 6.3 2800 Long rotor/stator 208/240 60 0.28 6.3 3400
Frequency
[Hz]
Power
[kW]
Capacitor
[µF]
0.23 5
0.28 6.3
0.23 5
0.28 6.3
6.3
6.3
6.3
Rpm
2800
3400
2800
3400
3400
2
Page 3
Pumps with long rotor/stator are suitable for non-stop service (Rack Type) while pumps
with short rotor/stator are suitable for intermittent service only.
TThheerreeffoorree do NOT use pumps 0L1079
and 0L1100 in any Rack Type
and 0L1100 in any Rack Type
They are suitable for Undercounter, Frontal Loading, Hood Type and Pot&Pan Washer machines.
do NOT use pumps 0L1079
.
Pumps 0L1104 / 0L1111 should NOT be used instead of 0L1079 / 0L1100
turning the shell 90° because the sealing is NOT longer guaranteed.
0L1104 / 0L1111 0L1079 / 0L1100
3
Page 4
Action in Field
PW1M-2M / WT830M-850M
New pumps are not perfectly interchangeable towards the previous ones:
long rotor/stator pumps are a bit bigger than old pumps while short rotor/stator pumps are smaller than old pumps;
the inlet is now 2 mm larger (so new inlet hoses are needed accordingly);
the capacitor is fitted on board.
New pumps can be fitted in older machines only with following parts:
Product Family
LS5WS / WT4WS
LS6EA / WT30E
LU7 / WTU40
LS9 / WT55
LS10EA-14EA / WT65E
WT830EA-850EA
Screw M6x20
(2 pcs)
Still need 049310 (recoded as 0L1030) and 049612
since there is not enough space for the new ones
0G1698
x 2
Pump holder
(1 pc)
0L1118 (“L” shape) 0L1108
not needed not needed
Inlet hose
(1 pc)
RT140-190-270
Eco and Ecoplus versions
(with duo rinse)
not needed
WT100-140-150-190-200-270
Basic, Eco and Ecoplus versions
(with duo rinse)
The old pump holder 0L0144
(“U” shape) can be used
adding 2 holes
not needed
Orders for old 049310 / 049612 / etc. will be switched automatically to new 0L1079 / 0L1100 / etc. since these new short rotor/stator pumps are used in more machines.
Please, be aware that water leakage may happen again if the rinse
pump has worked without water (burning the shaft sealing).
4
Loading...