Electrolux RCDR4M33T User Manual

Identification:
Technical Bulletin no:
Date: Issuer: Factory:

Subject

Model
Problem Reason Action in
Factory
D02-D03-D04
CGX2005-17 (page 1 of 1), 2nd
21 April 2006 R. Sartor (DWS Customer Support) DW Vallenoncello - Italy

Rinse Aid Injection in UC, UW & HT

Undercounter LS5-6E / WT4-30E, Utensils Washer LU7 / WTU40, Hood Type LS9-10EA-14EA / WT55-65 with atmospheric boiler and peristaltic rinse aid dispenser.
Undercounter LS6E / WT30E and Hood Type LS14EA / WT65E with Water Softener built-in are not involved in this change since they have rinse aid injection to the water softener assembly instead of directly to the boiler.
Water / rinse aid leakage from connection between rinse aid hose and boiler. The rinse aid hose (in PE-HD) is cracked. Since serial number 53800001 we have introduced a silicon hose between the
rinse aid hose and the boiler injection and since serial number 61600001 we have introduced the reticular MDPE hose 0L1163 instead of PE-HD hose 049905 and the silicon hose (no spare part code).
Action in Field
PE-HD
hose
MDPE
hose
Silicon
hose
Both silicon hose and MDPE hose are more reliable in case of combination of mechanical, thermal and chemical stresses.
The new MDPE hose is perfectly interchangeable towards previous hoses.