Identification:
Technical
Bulletin no:
Date:
Issuer:
Factory:
Subject
Model
Problem
Actions in
Field
D02-D04
CGX2006-13 (page 1 of 1), 2nd ed.
29 June 2007
R. Sartor (DWS Customer Support)
DW Vallenoncello - Italy
“SEr” Parameter in UC/HT with CWS
Undercounter LS6EA / WT38 and Hood Type LS14EA / WT65E with
Continuous Water Softener built-in.
Not working water softener after main board replacement (it seems the main
board resets SEr = 1 by itself).
Configuration parameters must be set following the sequence in the relevant
programming sheet (available in the service manual).
Therefore the parameter SEr must be set = 9 after having set all remaining
parameters and switched the machine off/on, otherwise the “dFL” sets the
main board as for a machine without water softener.
Example for Undercounter: set CFG parameters as first
Switch the machine OFF/ON Then set SEr = 9
Switch to the next parameter (“Adr”) then switch the machine OFF/ON.