Electrolux RCDR4M24 User Manual

Identification:
Technical Bulletin no:
Date: Issuer: Factory:

Subject

Model
Problem
Action in Field
D06
CGX2006-18 (page 1 of 2), 2nd ed.
27 April 2007 R. Sartor (DWS Customer Support) DW Vallenoncello - Italy
Start-up Switch & Thermal Protection Setting in new RT WTM / RTC / WTC
Whole Modular Rack Type (WTM series) range and Compact Rack Type (RTC / WTC series) range with relevant Drying Tunnels.
There are different start-up switches and thermal protections to be set according to the electrical load.
Here below you find all loads and their start-up switch and thermal protection setting when voltage supply is 400V / 3N / 50Hz:
WTM
Where
used
EWD
reference
Thermal protection setting (A)
Pump Ebara
DWO300
Prewash WTM250 WTM300
Wash WTM140 WTM165 WTM180 WTM200 WTM250 WTM300
QM4 /
QM7
6,3 3,3 1,2 1,3 1,6 0,8 1,3 4,2 1,2
Pump Ebara
DWO150
Prewash
WTM300
Wash WTM165 WTM200 WTM250 WTM300
QM5 QM8 QM1 QM2 QM2 QM6 QM11 QM11
Pump Ebara
CDX70/05
Prewash WTM180 WTM200
Duo Rinse
pump
LGB
ZF121SX
All WTM All WTM All WTM
Rinse pump
LGB PMP45
Rinse pump
Olympia
T45
CU fan
Lafert
ST56S2
Level A
(with ESD)
DT900 fan
Lafert
AM90L BA6
Drying Tunnel
900 mm
DT600 &
DT90° fan
Lafert
ST71C4
Drying
Tunnel
600 mm
&
Corner
Drying
Tunnel
ELECTROLUX PROFESSIONAL SPA MAILING ADDRESS TELEPHONE WEBSITE VAT NO.
VIA SEGALUZZA, 30 33170 PORDENONE - ITALY
OFFICE ADDRESS TELEFAX E-MAIL ADDRESS
VIA SEGALUZZA, 30 33170 PORDENONE - ITALY
Share more of our thinking at www.electrolux.com
++39 0434 380650 www.electrolux.com 00072220932
++39 0434 380643 ++39 0434 385646
riccardo.sartor@electrolux.it
RTC /
WTC
Where
used
EWD
ref.
Thermal
protec.
setting
(A)
DWO300
Prewash
WTC220
RTC140
Level A/B
RTC220
Level A/B
HEATERS
Power
(kW)
EWD
reference
Start-up
switch
setting (A)
Pump Ebara
Wash
Pump
FIR 4290
Wash
WTC140
RTC140
Level C
Pump Ebara
DWO150
Wash
RTC90
Level B
RTC180
Level A/B
RTC220
Level A/B
Pump
LGB
ZF523SX
Wash
WTC90 WTC180 WTC220
RTC90
Level C
RTC180
Level C
RTC220
Level C
Pump Ebara
CDX70/0
5
Prewash RTC180
Level A/B
Pump
FIR 1212
Prewash WTC180
RTC180
Level C
Rinse pump
LGB
PMP45
Zanussi
Level A/B
Rinse pump
Olympia
T45
Zanussi
Level A/B
CU fan
Lafert
ST56S2
Level A
DT900
fan
Lafert
AM90L
BA6
Drying
Tunnel
900 mm
DT600 &
DT90° fan
Lafert
ST71C4
Drying
Tunnel
600 mm
&
Corner
Drying
Tunnel
QM4 QM4 QM4 QM4 QM8 QM8 QM2 QM2 QM6 QM11 QM11
6,3 5,7 3,6 2,4 1,2 1,2 1,6 0,8 0,6 4,2 1,2
Prewash
tank
600 mm
with
sanitization
cycle
QF10
Boiler Boiler
10,5
6,0 +
+ 6,0
6,0
QF1 QF1
Wash
Tank
Wash
Tank
RTC /
WTC
Wash Tank
WTM165 WTM200
6,0 + 6,0 10,5 10,5 10,5
QF4
(Compact)
QF8
QF4
(Compact)
QF4
(Modular)
QF5
(Modular)
(Modular)
Wash
Tank
Duo
Rinse
Dryer
10,5
+
3,0 8,25 10,5 + 6,0 10,5
10,5
QF4 QF3 QF11
Prewash
tank with
sanitization
cycle
QF7 / QF9
(Modular)
QF8
(Compact)
32 22 22 20 18 18 32 10 15,3 32 20
WT44 / WT66
USA only
Pump
Ebara DWO200
Pump
Ebara CDX04
Rinse pump
Olympia T45
Where used Wash Prewash (WT66) Rinse
EWD reference QM4 QM8 QM2
Thermal protection
setting (A)
WT44 / WT66
USA only
Boiler 208V
4 x 6 kW
12 3,6 2,1
Tank 208V
2 x 9 kW
Boiler 240V
4 x 6 kW
Tank 240V
2 x 9 kW
EWD reference QF3/QF4/QF5/QF6 QF1/QF2 QF3/QF4/QF5/QF6 QF1/QF2
Start-up switch
setting (A)
22 32 20 29,3
Share more of our thinking at www.electrolux.com