ELECTROLUX HOME PRODUCTS PTY LTD
ABN 51 004 762 341
Technical Publication Nº KSSSI92 Date: 03/12
KELVINATOR
SPLIT SYSTEM
AIR-CONDITIONER
KSV26CRB
KSV26HRB
Copyright 2012 ELECTROLUX HOME PRODUCTS PTY LTD Technical Services
KSV35CRB
KSV35HRB

EEPROM parameter error. (Indoor Unit)
EEPROM parameter error. (Outdoor Unit)
Indoor / outdoor units communication protection.
Open or short circuit of outdoor condenser pipe, outdoor ambient temperature & compressor
temperature sensors.
Open or short circuit of room or evaporator temperature sensors.
High & Low-temperature protection of condenser / Outdoor fan motor feedback circuit error.
Temperature protection of compressor top - low refrigerant charge.
Inverter compressor drive error.
Over voltage or too low voltage protection.
Indoor fan motor circuit error.
Indoor Unit & PCB test board Error Display.
DISPLAY LED STATUS PAGE
Not
F1, F2 & F3
No operation by use of remote control.
3
Page 2 KSSSI92