Electrolux Kelvinator KSV26HRB, Kelvinator KSV26CRB, Kelvinator KSV35HRB, Kelvinator KSV35CRB Diagnostic Manual

ELECTROLUX HOME PRODUCTS PTY LTD
ABN 51 004 762 341
MODELS:
Issue: 4
DIAGNOSTIC MANUAL
Technical Publication Nº KSSSI92 Date: 03/12
KELVINATOR
SPLIT SYSTEM
AIR-CONDITIONER
KSV26CRB KSV26HRB
Copyright 2012 ELECTROLUX HOME PRODUCTS PTY LTD Technical Services
KSV35CRB KSV35HRB
Operating
E0
EEPROM parameter error. (Indoor Unit)
4
F0
Over current error
4
F4
EEPROM parameter error. (Outdoor Unit)
5
E1
Indoor / outdoor units communication protection.
6 to 14
Open or short circuit of outdoor condenser pipe, outdoor ambient temperature & compressor temperature sensors.
15 & 16
E4 & E5
Open or short circuit of room or evaporator temperature sensors.
17
F5, L2 & PA
High & Low-temperature protection of condenser / Outdoor fan motor feedback circuit error.
18 & 19
P0
Module protection.
20
P2
Temperature protection of compressor top - low refrigerant charge.
219
P4
Inverter compressor drive error.
22 & 23
P1
Over voltage or too low voltage protection.
23
E3
Indoor fan motor circuit error.
24
Indoor Unit & PCB test board Error Display.
DISPLAY LED STATUS PAGE
Not
F1, F2 & F3
No operation by use of remote control.
3
Page 2 KSSSI92
Loading...