PROFESSIONAL LAUNDRY
Rotary Finishing Cabinets
FRC1, FRC2, FRC3
Features and benefits
•Even distribution of steam moistens the fabric to remove creases
•Hot air blowing presses and dries the fabric
•Body form with extending shoulder, shapes and supports the garment
•Range of sleevers/clamps improve the finish
•Trouser waist expander shapes and supports the garment
•Microprocessor, stores various programmes
•Adjustable air blowing baffle, suitable for various fabric types
•Integral 10 or 12 kW steam boiler, simplifies the installation (only FRC2)
Main options
•Automatic start on door closing, simplifies the operation
•Suspended all steam iron, enables hand finishing
•Additional body form/trouser support for high volume production
•Multiple hanger device, enables conditioning garments on hangers
•External blower, for pre-forming/post finishing
•Additional heating – 15 or 18 kW boiler (only FRC2)
|
Electrical connections |
|
FRC1 |
FRC2 |
FRC3 |
|
|
|
|
Voltage |
|
|
|
|
|
|
|
|
|
208-240V 3 AC 50/60 Hz |
kW |
0.75 |
|
0.75 |
|
|
|
400-415V 3N AC 50 Hz |
kW |
0.75 |
|
0.75 |
|
|
|
|
Voltage, built-in boiler |
|
|
|
|
|
|
|
|
208-240V 3 AC 50/60 Hz |
10 kW |
- |
11.4 |
- |
|
|
|
|
380-400V 3N AC 50 Hz |
12 kW |
- |
13.4 |
- |
|
Please note: |
|
|
|
|
15 kW |
- |
16.4 |
- |
|
|
|
|
|
|
The following configuration is available: |
||||
|
|
|
18 kW |
- |
19.4 |
- |
|
|
|
|
|
|
FRC1: Trouser device + Body Form |
||||
|
|
|
|
|
|
|
|
|
|
Steam and water connections |
|
|
|
|
FRC2: Body Form + Body Form |
||
|
Steam |
DN |
15 |
- |
15 |
|
FRC3: Trouser device + Trouser device |
|
|
|
|
||||||
|
Rec. steam pressure |
kPa |
500 |
- |
500 |
|
|
|
|
Steam consumption |
kg/h |
16-20 |
- |
16-20 |
|
|
|
|
Condensate |
DN |
15 |
- |
15 |
|
|
|
|
Water supply |
mm |
- |
Ø12 |
- |
|
|
|
|
Boiler drain |
DN |
- |
15 |
- |
|
|
|
|
|
|
|
|
|
|
|
|
|
Shipping data |
|
|
|
|
|
|
|
|
|
|
net, kg |
205 |
270 |
205 |
|
|
|
|
|
crated, kg |
235 |
300 |
235 |
|
|
|
|
|
boxed, kg |
295 |
360 |
295 |
|
|
|
|
|
|
|
|
|
|
|
|
Dimensions in mm |
|
|
|
|
|
|
|
|
A Width |
|
1100 |
1100 |
1100 |
|
|
|
|
B Depth |
|
1050 |
1050 |
1050 |
|
|
|
|
C Height |
|
2040 |
2040 |
2040 |
|
|
|
|
D |
|
1840 |
1840 |
1840 |
|
|
|
|
E |
|
870 |
870 |
870 |
|
|
|
|
F |
|
1530 |
1530 |
1530 |
|
|
|
|
|
|
|
|
|
|
|
|
1Control panel
2Electrical connection
3Steam connection
4Condensate
5Boiler drain (built-in boiler only)
6Water supply (built-in boiler only)
7Air exhaust
A |
C |
1 |
E |
Front |
www.electrolux.com/laundrysystems
Share more of our thinking at www.electrolux.com
|
B |
7 |
|
6 |
|
D |
|
3 |
|
4 |
2 |
5 |
|
|
5268 |
Left side
09.15 |
alter specifications without notice. |
No. 438913361/01 |
reserve the right to |
Art. |
We |