Electrolux FPA3-D User Manual

PROFESSIONAL LAUNDRY
Dry Work Presses – Air operated
FPA2-D, FPA3-D, FPA4-D
Features and benefits
• Even distribution of steam from head and buck moistens the fabric to remove creases
• Adjustable pressure regulator for pressing different fabrics
• Buck vacuum, holds fabric in place and dries it
• Air operated reduces operator fatigue
• Foot closing for hands free operation (only FPA4-D)
• Padded head avoids glazing the fabric
• Padded buck reduces impressions
Model FPA2-D shown
Main options
• Features that simplify the installation
- Integral10,12, 15 or 18 kW boiler
- Integral vacuum fan
- Integral air compressor
• All steam iron for safe operation
• Electric steam iron
• Safety head guard (CE) improves operator safety (standard on FPA4-D)
• Steam, steam/air gun and spotting arm for removal of spots (only FPA2-D/FPA3-D)
• Teflon coated head plate durable head cover (only FPA2-D/FPA3-D)
Electrical connections Standard Built-in Built-in Built-in
A
H
H
M
boiler compressor vacuum
Voltage
208-240V 3 AC 50/60 Hz kW
alt. 10 1.1 0.25
380-415V 3/3N AC 50/60 Hz kW 12 4 15 18
Steam, air and vacuum connection
Steam DN 15 - 15 15 Rec. steam pressure kPa 400-600 - 400-600 400-600 Steam consumption kg/h 14-25 - 14-25 14-25 Condensate DN 15 - 15 15 Water supply mm - Ø13 - -
R = 650
Boiler drain DN - 15 - ­Compressed air DN 10 10 - 10 Rec. air pressure kPa 800-1000 800-1000 - 800-1000 Air consumption l/h 400 400 - 400 Vacuum mm Ø100 Ø100 Ø100 ­Vacuum air consumption m Vacuum depression mm H
3
/h 900 - - 500
O 10-20 - - 5-8
2
Shipping data
net, kg 279 374 374 298 crated, kg 330 425 425 350
R = 1200
boxed, kg 394 489 489 415
Dimensions in mm
A Width 1450 1450 1450 1450 B Depth 1135 1135 1135 1135 C Height 1450 1450 1450 1450 D 1250 1250 1250 1250 E 1030 1030 1030 1030 F 800 800 800 800 G 920 920 920 920 H 1190 1190 1190 1190 I 470 470 470 470 J 205 205 205 205 K 445 445 445 445 L 325 325 325 325 M 540 540 540 540 N 180 180 180 180 O 140 140 140 140
1 Control panel 2 Electrical connection 3 Steam connection 4 Condensate
5 Air connection 6 Water supply 7 Boiler drain 8 Vacuum outlet
I
Utility legger shape
FPA2-D shown
K
Legger shape
FPA3-D shown
J
5263
L
5279
ON
5264
D
Front
www.electrolux.com/professional
1
2
5245
3, 4
Topper shape
FPA4-D shown
45°
3
4
C
5
E
F
5245 A
G
B
8
6
Rear side
7
5246
Left side
Share more of our thinking at www.electrolux.com
Art. No. 438913241/2015.01.14
We reserve the right to alter specifications without notice.
Loading...