Reference washer extractor
Features and benefits
• Meets IEC and ISO international standards
• Suitable for testing washing effects of detergents and
chemicals and for textile quality control
• Suspended drum construction allows a high extraction force.
No foundation required
• Small space between outer/inner drum for efficient use of
water and detergent
• Dual water control of volume (weight) and level
• Built in scale for precise volume control, accuracy:
- volume control +/- 0.2 litre/bath
- level control +/- 0.8 litre/bath
• Equipped with Clarus Control
electronic timer
• Frequency controlled motor system for flexibility in
programming and precise speed
• Test tap for water samples
• Stainless steel drum assembly, front, side and top panel
®
- a fully programmable
PROFESSIONAL LAUNDRY
Wascator FOM71 CLS
Main options
• WPM (Wash Program Manager) PC programming kit in
Windows
• Extra program memory cards
Main specifications
Drum, volume litre
diameter ø mm
Extraction, max rpm
G-factor, max
Heating electricity kW
Certified in accordance with ISO 9001 and ISO 14001 and approved IP 24D.
Wascator FOM71 CLS
61
520
1100
350
5.4
Function/subsystem
Ambient conditions
The machine shall be able to function during the same
ambient conditions as normal washing machines.
The functional values with tolerances will be valid if following ambient conditions are kept.
Voltage
Frequency
Inlet water Cold
Hot
Water pressure
Ambient temperature
Inner drum
Diameter
Depth
Volume
Lifting vanes: Number
Height
Radius
Base width
Perforation: Diameter
Depth of countersink
Total hole area
Material: Stainless steel
Outer drum
Diameter
Sump
Material: Stainless steel
Door opening
Opening diameter
Cabinet
Stainless steel
Drum speed
Washing speed: Programmable
Extraction: Programmable
Reversing rythm
Programmable
Water level
Weight sensing
Repeatability
Stepsize
Dosing accuracy weight control
Level sensing:
Repeatability
Stepsize
Dosing accuracy level control
Thermostat
Continuos variable in each wash sequence
Selectable interval
Programming steps
Switch off temperature accuracy in Interval 30-97
Interval switch off temperature – switch on temperature
o
C
Nominal ±2%
Nominal ±2%
Max (60±2)
(240±50) kPa
(15±2)
(20±5)
o
C
o
C
o
C
(520±1) mm
(315±1) mm
61 l
3
53 mm
17 mm
65 mm
5 mm
2.5 mm
2
600 cm
2333 (SS 18/8)
554 mm
~ (1300±25) ml
2333 (SS 18/8)
310 mm
2333 (SS 18/8)
(20 – 59±1) RPM
(200 – 1100±20) RPM
(0 – 250±0.1) = sec.
(Tolerance area refers to
timer intervals)
±0.1kg/bath
0.05kg
±0.2kg/bath
±5 mm
3 mm
±0.8litre/bath
Yes
o
C
(4-97)
o
C
1
o
C
±1
o
C
4