PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT 37°/0°
T
U
R
N
Mounting Plate Screws
Mounting Plate Screw
Motor Gear
Timing
Gear
Water Fill Adjustment
Replace Inverter Board
no
Check connections from Inverter
Board to Compressor
Are connections from Inverter Board to Compressor intact?
Identify and repair damaged wires or poor connections between Inverter Board and Compressor.
no
VCC Resistance Check
yes
CONTROL SETTING
Type A with Run / Start Capacitor 65°F (18°C) Ambient 90°F (32°C) Ambient
Operating Time
Freezer Temperature
Refrigerator Temperature
Low Side Pressure
High Side Pressure (last 1/3 cycle)
Wattage (last 1/3 cycle) 30 to 50 50 to 70
Amps (running)
Base Voltage 115 vac (127 vac max)
90 to 100% 100%
-5° to 2°F
(-20° to -17°C)
34° to 39°F
(1° to 4°C)
-2 to 6 psig
(-14 to 41 kPa)
85 to 105 psig
(586 to 724 kPa)
.4 to .8 .7 to .9
-1° to 3°F
(-18° to -16°C)
34° to 39°F
(1° to 4°C)
-2 to 6 psig
(-14 to 41 kPa)
120 to 135 psig
(827 to 931 kPa)
DEFROST SPECIFICATIONS
Thermal Cutout Heater Defrost
Cabinet Size:
27’ & 28’ SD, 22’ CD
Electronic Timer - (ADC) Defrost 24 minutes every 6-96 hours of compressor run time.
Freezer
Fresh Food
Ice Maker
Cut-in Cut-out Watts Ohms Cut-out
110°F
(43.3°C)
110°F
(43.3°C)
135°F
(57.2°C)
135°F
(57.2°C)
500 26.5 48°F
70 188.9 68°F
Termination
CONDENSER FAN MOTOR
Watts RPM Amps
3.1
1100 CW
Opposite Shaft
0.03 Running
FREEZER ICE MAKER SPECIFICATIONS
Electrical 115 vac (127 vac max)
Thermostat Opens at 48°F ( 9°C), Closes at 15° F ( -9°C)
Heater Voltage 115 vac
NO
NC
NEUTRAL
ICE MAKER
P-4
RED
P-2
LINE
BLK
P-3
P-1
THERMAL
CUT-OUT
CE MAKER
I
GRN / YEL
MOLD
CAUTION
All electrical parts and wiring must be shielded from torch flame. DO NOT allow torch to touch insulation; it will char at 200°F and flash ignite (burn) at 500°F. Excessive heat will distort the plastic liner.
BRN
MOTOR
BLK
MOUNTING
PLATE
FREEZER ICE MAKER INFORMATION
ICE MAKER
RED
MOLD HEATER
165 WATTS
ICE MAKER
HOLD
SWITCH
C
BLK
NO
NC
RED
LT. BLUE
THERMOSTAT
NO
NC
C
WATER FILL
SWITCH
BLU
C
SHUTOFF
SWITCH
YELLOW
(Where Applicable)
Test Cycling: Remove cover by inserting screwdriver in notch at bottom
and prying cover from housing. Use screwdriver to rotate motor gear counterclockwise until holding switch circuit is completed. All compo­nents of ice maker should function to complete the cycle.
Water Fill Volume: The water fill adjustment screw will change the fill time. One full turn is equal to 20cc (.68 oz.). The correct fill is 102 to 130cc (3.4 to 4.3 oz.). When a water valve is replaced, the fill volume must be checked.
Thermistor
(8°C)
(20°C)
LT. BLUE
WATER VALVE
SERVICE DATA SHEET
A06021901
ICE & WATER - AUTOMATIC DEFROST
BOTTOM FREEZER - R134a
IMPORTANT: PLEASE RETURN THIS SHEET TO ITS ORIGINAL LOCATION.
ERROR CODES SPECIAL MODES
Display
FZ FF FZ FF (press for up to 10 sec. simultaneously)
-- OP Open FF Cavity
OP -- Open FZ Cavity
-- SH Shorted FF Cavity
SH -- Shorted FZ Cavity
SY CF UI to Main Board
SY CE UI to Main Board
SY EF Freezer Evaporator Fan
Interpretation Mode
Thermistor
Thermistor
Thermistor
Thermistor
communication failure;
on start up
communication error;
after a period in operation
Failure
Notes:
• Always check for pin back-outs, pinched or damaged wires before replacing components.
• Determine whether failure is caused by the component, main control board or wiring.
• Refer to Service Manual for additional information.
Manual Defrost d F FF + and FF - Same to deactivate
Demo / Showroom 77 77 FZ + and FF - Unplug to deactivate
Sabbath Sb Sb FZ - and FF - Same to deactivate
System Diagnostic No FF or FZ display,
Current Air Temps FZ Temp FF Temp FZ - and FF +
FFIM Diagnostic Numerical display of
Contact TID before replacing main control board.
FRESH FOOD ICE MAKER DIAGNOSTIC MODE
Activate: Press FZ UP and FF UP temperature pads for up to 10 sec. simultaneously.
Deactivate: Press FF UP for up to 10 sec. FFIM Diagnostic Mode will automatically deactivate after 5 min. of inactivity.
52C Ice Maker Thermistor Activates
55C Water Valve Press power
57C Evaporator Fan (FFIM) Press power
58C
63C Twist Tray Press power
Press FF UP or FF DOWN to move forward or backward through tests.
NOTE: Silence alarm.
Test To activate test Passing Result
automatically
on-off
on-off
Ice Level Sensor Activates
automatically
on-off
FZ display shows temperature sensed by Ice Maker Thermistor. “OP” if open; “SH” if short
Remove ice tray to collect water into a measuring container to measure water fill. If collecting water into ice tray, first perform test 63C to empty ice tray.
“On” on FZ display when fan activated, “OFF” when deactivated.
Remove ice bucket. Allow bail arm to drop freely. Pass if no alarm when tray returns to “home” position. Hold bail arm up. Pass if alarm sounds when tray returns to “home” position. This test runs continuously until another test is selected.
Remove ice bucket. FZ display shows “1” and “GOOD”.
FRESH FOOD ICE MAKER FILL TIME ADJUSTMENT MODE
NOTE: First consider water filter condition before adjusting fill time.
Activate: Press and hold the Water and Crush pads for up to 10 seconds.
Deactivate: Exits automatically after 10 seconds, or press any button other than + or -.
Press FF + or FF - to adjust between the 3 fill settings.
Display
FZ FF
Min Fill Time (default)
ICE
= Mid Fill Time
= Max Fill Time
VCC COMPRESSOR MOTOR RESISTANCE CHECK
Check resistance between terminals 1 and 2, 2 and 3, 3 and 1.
If all resistances are equal,
compressor is operative.
Display Activate Deactivate
all UI LEDs on
first test
FZ + and FF - Press and hold FF +
and Water
FZ + and FF + Press and hold FF +
Description
to deactivate
Automatically
after 10 sec
to deactivate
Activate: Press Deactivate: Press
• Tests marked with “*” may not be applicable to this unit and will not be displayed in System Diagnostic Mode.
• Tests displayed in diagnostic mode but not described below are for internal purposes only; advance through.
• View UI display for “on,” “off,” “CL,” “OP,” “SH,” “LO,” “HI” or numerical results of tests.
• Listen for operating sounds; feel for heat or air flow as appropriate to determine results of tests.
28 Dispenser Paddle Press disp. paddle “on” on UI when depressed; “off” when released 34 Ambient Thermistor
46 Humidity Sensor Activates automatically “OP” if open, “SH” if short. AC Heater System: Displays %RH. DC Heater Sys-
47 Dispenser Pocket Heater Press power on-of Heater on when “on’ off when “off”.
10 Auger Motor Press power on-off FF door must be closed. Motor running when “on”; motor stopped when “off” 11 Cube/Crush Solenoid Press power on-off FF door must be closed. Do not leave solenoid in activated state.
12 Condenser Fan Press power on-off Fan running when “on”; stopped when “off” 41 Perfect Temp Drawer
43 Mullion Anticondensa-
38 VCC Compressor Press power on-off Compressor running when “on”; off when “off” 15 Freezer Evapora-
20 FZ Lights Press power on-off FZ lights on when “on”, off when “off” 22 Damper Press power on-off Perform test 15 and set fan to “HI”. Then check for air flow when open “OP”; and
36 Ice Chute Door Depress ice chute door
23 FF Door Open/Close FF door “CL” on UI when door closed; “OP” when open 24 FZ Door Open/Close FZ door “CL” on UI when door closed; “OP” when open 26 Ice Maker Defrost
29 FF Thermistor Activates automatically UI shows temperature sensed by FF thermistor; pass if within 10°F of tempera-
30 FZ Thermistor Activates automatically UI shows temperature sensed by FZ thermistor; pass if within 10°F of temperature
33 Ambient Thermistor @
39 Freezer Evaporator
45 Ice Maker Mold
68 Ice Maker Evaporator
0- Firmware Parameters Press power on-off Displays digit sequence; record 1- Main Board Firmware Press power on-off Displays digit sequence; record 3- UI Firmware Press power on-off Displays digit sequence; record
Test To activate test: Passing result
-- First Screen -- All LEDs on UI illuminated, except digit displays.
-- Second Screen -- All segments of UI digit displays illuminated.
-- Third Screen -- Blank UI display, no LEDs illuminated.
@ UI
2 Freezer Defrost Heater Press power on-off Freezer defrost heater on when “on”; off when “off”. Evaporator thermistor
3 FF Lights powered by
external board
8 Water Valve
(Dispenser)
(PTD)
tion Heater
tor Fan
Heater
Main Board
Thermistor
Thermistor
Thermistor
FZ UP
and
FF UP
Note: Silence alarm.
Activates automatically UI shows temperature sensed at UI; Pass if within +20˚F/-10˚F of temperature
Press power on-off FF lights on when “on”; off when “off”
Press power on-off FF door must be closed. Be prepared to collect water at dispenser.
Press power on-off PTD UI illuminated when “on”, off when “off”
Press power on-off Flip mullion heater on when “on”; off when “off”
Press power on-off Press to toggle between “off”, “LO” and “HI”. A current sensor reading is flashed
or press power on-off
Activates automatically Heater is turned on automatically. The ice maker evaporator thermistor tem-
Activates automatically UI shows temperature sensed at main board; pass if within +20°F/-10°F of tem-
Activates automatically UI shows temperature sensed by freezer evaporator thermistor; pass if
Activates automatically UI shows temperature sensed at ice maker; pass if within +20°F/-10°F of tem-
Activates automatically UI shows temperature sensed by evaporator thermistor; pass if within 10°F of
FZ DOWN
for up to 10 sec. Diagnostic Mode will automatically deactivate after 5 min. of inactivity.
for up to 10 sec. simultaneously. Press
measure with gauge at UI location. “OP” if open; “SH” if short.
tem: “HI” - heater should be on. “Lo” - heater should be off. %RH is displayed when humidity is between “Lo” and “HI” values; heater could be on or off.
temperature is flashed. Watch for temp increase with the heater on. It may take a few minutes for the evaporator to heat up.
Water dispenses when “on”; stops when “off”
Solenoid activated when “on”; deactivated when “off”.
(units are not mA). OFF reading should be around 2. “LO” speed reading should settle down to around 9. “HI” speed reading should settle down above 40.
no air leaks when closed “CL” “OP” on UI when manually opened; “CL” when closed . Or using “power on-
off”, motor drive door open “OP” or closed “CL”
perature is flashed. Watch for temp increase with the heater on. It may take a few minutes for the evaporator to heat up.
ture measured with gauge at FF thermistor location. “OP” if open; “SH” if short
measured with gauge at FZ thermistor location.“OP ” if op en; “SH ” if sh ort
perature measured with gauge at main board location. “OP” if open; “SH” if short
within 10°F of temperature measured with gauge at evaporator thermistor location.“OP” if open; “SH” if short
perature measured with gauge at ice maker mold. “OP” if open; “SH” if short
temperature measured with gauge at evaporator thermistor location. “OP¯” if open; “SH¯” if short
FF UP
to advance through tests.
IMPORTANT SAFETY NOTE
SYSTEM DIAGNOSTIC MODE
The information provided herein is designed to assist qualified repair personnel only. Untrained persons should not attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before servicing this appliance.
IMPORTANT
If any green grounding wires are removed during servicing, they must be returned to their original position and properly secured.
Service Mode For Perfect Temp™ Drawer
Activation This mode is accessible only when the drawer is in OFF mode. Press and hold the temperature decrease key (–) and the temperature in­crease key (+) for 5 seconds.
Deactivation Press and hold the tempera­ture (+) key for 5 seconds, or no keys pressed in 5 minutes returns to the OFF mode of operation.
Test Operation
The up/down buttons will be used to navigate through the tests and the ON/OFF button will be used to initiate the displayed test.
Fan Test
Display shows “F1” for fan on or “F0” for fan off.
Heater Test
Display shows “H1” for heater ON or “H0” for heater OFF.
Damper Test
Display shows “d1” for damper open, or “d0” for damper closed. Damper movement may take 30 seconds.
To Test Damper
1. Remove drawer.
2. Start damper test.
3. Observe damper moving open and closed.
4. Exit damper test.
Report NTC Temperature Test
Display shows “b1” for cham­ber sensor test. The UI display will show —°F until the main board responds with associated sensor temperature reading.
Display Test
“L0” for display test. The display test will cycle through all the dis­play segments with a minimal on time for each segment.
Fault Codes Listed on Diagram Sheet
PTD COVER
PTD USER INTERFACE KEYPAD ASSEMBLY
FLEX CABLE TO KEYPAD
THERMISTOR T1 (PTD DRAWER)
TO THE TWO LEDS
IN THE PTD COVER
PTD MODELS ONLY
INLINE CONNECTOR ABBREVIATION KEY
ABBR. EXPLANATION
AT1 9 PIN CONNECTION AT AIR TOWER
9 PIN CONNECTION IN FRESH
IM1
FOOD ICEMAKER COMPARTMENT 6 PIN CONNECTION IN FRESH
IM2
FOOD ICEMAKER COMPARTMENT 5 PIN CONNECTION AT THE LEFT
LH2
DOOR UPPER HINGE 9 PIN CONNECTION IN THE MAIN
MB1
BOARD HOUSING BEHIND THE TOE GRILLE 4 PIN CONNECTION IN THE MAIN
MB2
BOARD HOUSING BEHIND THE TOE GRILLE 9 PIN CONNECTION IN THE
MC1
MACHINE COMPARTMENT TO THE LEFT OF THE COMPRESSOR 9 PIN CONNECTION AT THE RIGHT
RH1
DOOR UPPER HINGE 5 PIN CONNECTION AT THE RIGHT
RH2
DOOR UPPER HINGE 2 PIN CONNECTION AT THE RIGHT
RH3
DOOR UPPER HINGE
RH1
RH2
BACK VIEW
MC1
FRONT INSIDE
IM1
IM2
J3
PTD USER
INTERFACE
BOARD
J2
RH3
VIEW
AT1
1
PIN 1
2
PIN 2
3
PIN 3
4
PIN 4 PIN 5 PIN 6 PIN 7 PIN 8
CONNECTION TO
PTD COVER
LH2
PTD
DAMPER
GRY
ORN
RED
PTD
BLACK
FAN
RED/YELLOW
4
BROWN/YELLOW
3
BLACK/YELLOW
2
WHITE/YELLOW
1
RED/BLACK
PINK/WHITE
WHITE/PINK
BLACK/WHITE
WHITE
WHITE
FROM BOTTOM
LEFT SIDE
FF LED
AT1, IM1, MB1, & RH1
3
1
1
J8
2
1 2
PTD
J6
3
MAIN PCBA
4
1 2 3 4
J7 5 6 7
1 2
J11 3
4
FREEZER
EVAPORATOR
SENSOR
FREEZER
SENSOR
FRESH FOOD
SENSOR
IM EVAPORATOR
SENSOR
IM FAN
MOTOR
TRAY
SENSOR
COMPRESSOR
CONTROL SIGNAL
12V DC DAMPER
MOTOR
RH LIGHT
SWITCH
(DOOR OPEN)
LH LIGHT
SWITCH
(DOOR OPEN)
9
9
7
7
LT BLUE
J332
1
1 2
J2
3 4
USER
INTERFACE
+12V DC
+12V DC
+12V DC
+12V DC
REVERSIBLE
12V
+12V DC
M
TWIST MOTOR
BAIL ARM
SWITCH
SEE FREEZER
EVAPORATOR
FAN (DC)
RED/YEL
BRN/YEL BLK/YEL
WHT/YEL
FREEZER DOOR
SWITCH
(DOOR OPEN)
3
LT BLUE
GND
COMM
BLK
RED
LEDS
1
PTD DRAWER
HEATER THERM.
BLK/PNK
1 2
GRN/YEL YEL/BLK
3
4
LT. BLU
2
J7
1
1 5 2 4
J6
3 6 9
10
J432
1
2
1
GRN/BLU
2
DK. BLU
1
M
2
1
3
YEL/BLK (COM) YEL/GRY (N/C) PUR/BLK (N/O)
PURPLE (COM)
YEL/BLK (COM)
YEL/GRY (N/C)
PURPLE (N/O) PURPLE (COM)
CATCH
PIN 3 PIN 4
PIN 5
LH2
IM1
PIN 6
PIN 7
PIN 2
PIN 1
RED
BLK
5
1
PTD MODELS ONLYPTD MODELS ONLY
PTD DRAWER
HEATER
PTD HEATER GROUND
PTD MODELS ONLY
DISPENSER
HEATER (DC)
FLAPPER POSITION
SWITCH
DISPENSER
PADDLE
DISPENSER
LIGHT
FLAPPER
MOTOR
GRY/WHT
GRY/WHT
1
2
AT1
PIN 6
PIN 5
PIN 3
PIN 2
66 4 2 1
4 2 1
YEL/PNK
YEL/PNK BLK/ORN BLK
LH2 & RH2
PIN 3 PIN 4 PIN 5
RH2
RH1
PIN 2
PIN 3
PIN 2
PIN 1
PIN 3
MB1
MB1
PIN 7
PIN 8
PIN 6
PIN 9
PIN 2
PIN 1
PIN 5
PIN 4
PIN 6
PIN 3
IM2
PIN 4
PIN 5
5
1
PTD ERROR CODES:
9X - SHORTED KEY/BUTTON, WHERE THE "X" IS: 1 FOR "ON/OFF" 2 FOR "+" 3 FOR "C/F" 4 FOR "-" 5 FOR "LOCK" 6 FOR "V" DOWN ARROW KEY 7 FOR "^" UP ARROW KEY
2X - OPEN NTC, WHERE THE "X" IS: 1 FOR THE PTD DRAWER NTC
3X - SHORTED NTC, WHERE THE "X" IS: 1 FOR THE PTD DRAWER NTC
CE - LOSS OF COMMUNICATION BETWEEN UI AND MAIN PCB
HI TIME OUT EXCEEDED
LO TIME OUT EXCEEDED
BLK
WHT
RED
GRY/WHT
GRY/WHT
GRY/WHT
GRY/WHT
GRY/BLK
GRY/BLK
GRY/RED
GRY/RED
GRN/BLU
DK. BLU
WHT
RED
BLU
YEL
GREY
GREY
WHT/GRN
WHT/RED
BRN/BLU
BRN/BLK
YEL/WHT
RED/WHT
BRN/WHT
RED/BLK
BLK/WHT
RED/YEL
BRN/YEL
BLK/YEL
WHT/YEL
RH1
YEL/GRY
PIN 5
YEL/GRY
PIN 8
MB1
YEL/PNK
YEL/PNK
LATCH
F - UCL OVER TEMP
F - LCL UNDER TEMP
DC SIDE
1
J9
2
OR
3
J11
4
5 6
+5V DC
7 8
+5V DC
J6
11 12
+5V DC
3
+5V DC
4
1
+12V DC
8 2
REVERSIBLE 12V DC
3
J7
4
+5V DC
7 5
+5V DC
6
3
+12V DC
4 5 6
+12V DC
1
J4
+12V DC
2
GND
9
11
+12V DC
12
OUT1A
5
OUT1B
6
J5
OUT2A
3
OUT2B
4
11
J5
+5V DC
7
BOARD-MOUNTED
1
AMBIENT THERMISTOR
J8
+5V DC
2
12
J5
+5V DC
8
RH3
2
121
GND
COMM.
+5V DC
+12V DC
ERF2500++ISO REFRIGERATOR
NEUTRAL
CAB. GROUND
U2 (SSR1)
LINE
NEUTRAL
CONTROL
3
9
7
1
AC SIDE
J112
LINE
RL5
J2
RL4
J3
RL8
RL9
J3
RL7
J2
RL1
J1
RL2
J2
RL6
J3
RL3
J3
MC1
9
7
3
3 7 4
6 3 5
1 5 4
2 2
1
3
1
BASE PLATE
GROUND
COMPRESSOR
GROUND
LT. BLU
GRN/YEL
BLK
YEL/RED
YEL/BLK
LT.BLU/BLK
RED
YEL
TAN
YEL
YEL/BLU
LT.BLU
BRN
CABINET WRAPPER
BRN/BLU
BLU/WHT
PUR/BLK
BOARD VIEW
J9
2
4
1
RH1
1
1
U2
3
RL4
RIGHT DOOR
FLANGE
RL1
RL2
RL5
RL3
RL6
RL9
RL8
RL7
GRN/YEL
PIN 1
PIN 2
RH3
1
WHT/BLU WHT/BLU
2 3
WHT/BRN
4
WHT/BRN
1
WHT/BLU
2
WHT/BLU
3
WHT/BRN
4
WHT/BRN
RG-9
TYPICAL LED CONNECTOR
J8
AMBIENT
TEMP
SENSOR
1
J5
FLIP MULLION COVER
2
1
MULLION HEATER
3
LED LIGHT WIRING
123
4
WHT/BRN
WHT/BRN
WHT/BLU
WHT/BLU
RG-5
LED LED
LED
RG-6
LED
RG-7
REFRIGERATOR LEDS
4321432
GRY
GRY
ORN
GRY
LED LED
432
WHT/GRN
LED LED
J1
J2
POWER CORD
(LINE)
RIBBED
BLK
LED POWER
J3-3
FF LEDS
CABINET BY COMPRESSOR
SPLICE
FREEZER
EVAPORATOR
HEATER
PIN 5
IM1
PIN 1
PIN 3
PIN 2
PIN 7
PIN 4
RH1
4
3
(NEUTRAL)
LT. BLU
LT. BLU
SPLICE
J3-1
BOARD
NEUTRAL
CONDENSER FAN
TWIST ICEMAKER
WATER VALVE
DISPENSER
WATER VALVE
MAIN INLET
WATER VALVE
TAN/YEL
FREEZER ICEMAKER
WATER VALVE
THERMAL CUT-OUT
COIL COVER
GROUND
ICEMAKER
EVAPORATOR
HEATER
BLU/WHT
PURPLE
1
PURPLE (COM)
2
PURPLE (N/O)
4
YEL/GRY (N/C)
6
YEL/BLK (COM)
1
PURPLE (COM)
2
PUR/BLK (N/O)
4
YEL/GRY (N/C)
6
YEL/BLK (COM)
2
1
PIN 5
LT. BLU
4
3
2
1
CUBE/CRUSH
SOLENOID
AUGER MOTOR
3
1
PIN 1
PIN 4
MC1
LT. BLU
BLK/PNK GRN/YEL
YEL/BLK LT. BLU
BLK/ORN
YEL/PNK
YEL/PNK
FREEZER DOOR
(DOOR OPEN)
GRN/YEL
CUBE/CRUSH SOLENOID
AUGER MOTOR
THERMAL CUT-OUT
LT. BLU
IM2
6
4
LT. BLU
CONTROL SIGNAL
RED/BLK BLK/WHT
BASE PLATE
GROUND
BLK
SWITCH
BEHIND FRONT
6
4
POWER
BLK
12 VDC
TO PERFECT TEMP DRAWER HOUSING
1 2 3
1
4
YEL/BLU
LEFT ROLLER
SPLICE
LH LIGHT
SWITCH
(DOOR OPEN)
RH LIGHT
SWITCH
(DOOR OPEN)
3
1
GRN/YEL
2
PIN 4
IM1
NON-RIBBED
MC1
PIN 2
PIN 3
BLK/PNK
PIN 6
TAN
DIODE
SPLICE
SPLICE SPLICE
DIODE
YEL/BLU
PIN 1
BLK
PIN 3
PIN 2
PIN 4
MB2
FREEZER
ICE MAKER
(SEE FZ ICE
MAKER DIAGRAM)
BRN
PIN 7
PIN 8
MC1
PIN 9
MB2
2
4
3
1
J3
VARIABLE SPEED
COMPRESSOR/ INV.
RIGHT HINGE
LT. BLU/BLK
BLK
LT. BLU
GROUND
PIN 9
PIN 1
PIN 6
J11
4
1
12
11
1
2
1
J4
1
J7
1
FRESH FOOD
POWER (120V AC)
RG-4
GRY
7 8
ORN
1
ORN
ORN
RG-8
1
1
432
WHT/RED
WHT/RED
WHT/RED
WHT/GRN
WHT/GRN
1
J6
+12V
GND
RG-1
RG-2
RG-3
RG-4
RG-5
RG-6
RG-7
RG-8
RG-9
NEUTRAL
123
4
WHT/BRN
WHT/BRN
WHT/BLU
WHT/BLU
WHT/BRN
LED
WHT/BRN WHT/BLU WHT/BLU
RG-3
WHT/BRN
LED
WHT/BRN WHT/BLU WHT/BLU
RG-2
WHT/BRN
LED
WHT/BRN WHT/BLU WHT/BLU
RG-1
WHT/BRN
2
GRY
1
ORN
WHT/BLU
PTD LEDS
PTD MODELS
ONLY
FREEZER LEDS
FZ-1FZ-2
J1-1
J1-3
LED POWER
PCBA
J3-3
J3-1
4 3 2 1
4 3 2 1
4 3 2 1
J4-3 J4-4
LED
J1-3
POWER
J1-1
BOARD
ERF2500++ISO REFRIGERATOR
CONTROL
MB1
LED POWER
MB2
BOARD
Wire Diagram A06687801