Electrolux EI32AR80QS Wiring Diagram

PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT MID-POINT
CONTROL SETTING
SERvICE DATA SHEET - 297299900
Capacitor Run or Induction Run
Operating Time 10 to 20% 20 to 30%
Refrigerator Temperature
Low Side Pressure (cut-in)
Low Side Pressure (cut-out)
High Side Pressure (last 1/3 cycle)
Wattage (last 1/3 cycle) 120 to 180 140 to 155
Amps (running) .8 to 1.3 1.0 to 1.5
Base Voltage 115 vac (127 vac max)
Cabinet Size
19’ 37° F (3° C) 47° F (8° C) 550 24
Electronic Timer - Defrost 30 minutes every 12 hours of compressor run time.
Watts RPM Amps
2.3 1100 CW Opposite Shaft 0.13 Running
70°F (21°C) Ambient 90°F (32°C) Ambient
2° to 4° C
25 to 30 psig
175 to 205 kPa
10 to 15 psig
70 to 100 kPa
120 to 130 psig 810 to 880 kPa
DEFROST SPECIFICATIONS
Thermostat Heater
Cut-in Cut-out Watts Ohms
CONDENSER FAN MOTOR
2° to 4° C
25 to 30 psig
175 to 205 kPa
10 to 15 psig
70 to 100 kPa
175 to 185 psig
1180 to 1260 kPa
IMPORTANT SAFETy NOTICE
The information provided herein is designed to assist qualified repair personnel only. Untrained persons should not attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before servicing.
STANDARD - AUTOMATIC DEFROST
REFRIGERATOR MODELS (R134a)
IMPORTANT
If any green grounding wires are moved during servicing, they must be returned to their original position and properly secured.
CAUTION: All electrical parts and wiring must be shielded
from torch flame. Do not allow torch to contact insulation; it will char at 200°F.
NOTE: Products come equipped with an Electronic Defrost Control.
To initiate defrost, press and hold air filter and alarm reset key simultainiously for three seconds. To terminate defrost, press and hold air filter and alarm reset key simultainiously for three seconds
IMPORTANT: PLEASE RETURN THIS SHEET TO IT’S ORIGI­NAL LOCATION