Electrolux EI32AR80QS Diagram

PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT MID-POINT
CONTROL SETTING
T
U
R
N
Mounting Plate Screws
Mounting
Plate
Screw
Motor Gear
Timing
Gear
Water Fill Adjustment
P O W E R
I CE MA KE R
ICE MAKER
I
CE MAKER
ICE MAKER
WATER VALVE
LINE
T HER MA L
C UT -O UT
HO LD
SW I T C H
T HER MO STAT
SH UT-OF F
SW IT CH
WA TER FI L L
S W I T C H
MOLD HEATER
MO L D
MO UN TI NG
PLATE
MOTOR
N E UT R AL
BLK
BLK
B LK
BL K
BLU
LT . B L U
LT. BLU
BRN
RED
GRN / YEL
GRN / YEL
RED
Y E L
YEL
YEL
P- 3
P- 1
P- 2
P- 4
Capacitor Run or Induction Run
Operating Time 40 to 50% 55 to 65%
Freezer Temperature
Low Side Pressure (cut-in)
Low Side Pressure (cut-out)
High Side Pressure (last 1/3 cycle)
Wattage (last 1/3 cycle) 100 to 120 110 to 130
Amps (running) .9 to 1.1 1.0 to 1.2
Base Voltage 115 vac (127 vac max)
Cabinet Size
19’ 21° F (-6° C) 42° F (6° C) 550 24
Electronic Timer - Defrost 30 minutes every 12 hours of compressor run time.
Watts RPM Amps
2.3 1100 CW Opposite Shaft 0.13 Running
Electrical 115 vac (127 vac max) 60 Hertz
Thermostat
Heater Wattage 165
ICE MAKER CONNECTOR PLUG CONNECTIONS
Wire Number Wire Color Connects to:
1 Green/Yellow Ground
IMPORTANT: PLEASE RETURN THIS SHEET TO IT’S ORIGINAL LOCATION
2 Yellow Water Valve
3 Black Line
4 Light Blue Neutral
70°F (21°C) Ambient 90°F (32°C) Ambient
-19° to -16° C
6 to 12 psig
41 to 83 kPa
-1 to 3 psig
-4 to 21 kPa
85 to 100 psig
575 to 670 kPa
DEFROST SPECIFICATIONS
Thermostat Heater
Cut-in Cut-out Watts Ohms
CONDENSER FAN MOTOR
ICE MAKER SPECIFICATIONS
Opens at 48° F ( 9° C), Closes at 15° F ( -9° C) Models with orange wire close at 8.96° F (-12.8° C)
-19° to -16° C
41 to 83 kPa
120 to 135 psig 810 to 910 kPa
6 to 12 psig
-1 to 3 psig
-4 to 21 kPa
SERVICE DATA SHEET - 297299800
STANDARD - AUTOMATIC DEFROST FREEZER
MODELS (R134a)
IMPORTANT SAFETY NOTICE
The information provided herein is designed to assist qualified repair personnel only. Untrained persons should not attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before servicing.
IMPORTANT
If any green grounding wires are moved during servicing, they must be returned to their original position and properly secured.
CAUTION: All electrical parts and wiring must be
shielded from torch flame. Do not allow torch to contact insulation; it will char at 200°F.
NOTE: Products come equipped with an Electronic Defrost
Control. To initiate defrost, press and hold air filter and alarm reset key simultainiously for three seconds. To terminate defrost, press and hold air filter and alarm reset key simultainiously for three seconds
ICE MAKER INFORMATION
Test Cycling
Remove cover by inserting screwdriver in notch at bottom and prying cover from housing. Use screwdriver to rotate motor gear counterclockwise until holding switch circuit is completed. All components of ice maker should function to complete the cycle.
Water Fill Volume
The water fill adjustment screw will change the fill time. One full turn is equal to 20cc (.68 oz.). The correct fill is 95 to 105cc (3.2 to 3.6 oz.). When a water valve is replaced, the fill volume must be checked.
Loading...