PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS
AT MID-POINT CONTROL SETTING
To p
View
Side
View
Front
View
47”
23 5/8”
2 7/8”
26 3/4”
24 1/4”
21 9/16”
34-5/16”
Adjustable to
35”
23 13/16”
3 5/16”2 3/4”
Type A with Run/Start
Capacitor
Operating Time
Wine Cooler Temperature
Beverage Center
Temperature
Low Side Pressure (cut-in)
Low Side Pressure (cut-out)
High Side Pressure
(last 1/3 cycle)
Wattage (last 1/3 cycle)
Amps (running)
Base Voltage 115 vac (127 vac max)
Watts RPM Amps
3.1 1100 CW Opposite Shaft 0.03 Running
BEVERAGE CENTER EVAPORATOR FAN MOTOR
3.2 3400 .05
1.7 each 9000 .02 each
WINE COOLER EVAPORATOR FAN MOTOR
65°F (18°C) Ambient 90°F (32°C) Ambient
N/A
45º F to 65º F 45º F to 65º F
35º F to 45º F 35º F to 45º F
30 to 45 psig
208 to 310 kPa
-2 to 4 psig
-14 to 28 kPa
90 to 120 psig
621 to 827 kPa
85 to 125 85 to 125
.75 to 1.2 .75 to 1.2
CONDENSER FAN MOTOR
14 to 37% (Wine Cooler)
30 to 50% (Beverage Center)
30 to 45 psig
208 to 310 kPa
-2 to 4 psig
-14 to 28 kPa
130 to 175 psig
896 to 1207 kPa
SERVICE DATA SHEET
241888502
WINE COOLER - BEVERAGE CENTER - R134a
IMPORTANT SAFETY NOTE
The information provided herein is designed to assist qualified
repair personnel only. Untrained persons should not attempt to
make repairs due to the possibility of electrical shock. Disconnect
power cord before servicing this appliance.
IMPORTANT
If any green grounding wires are removed during servicing,
they must be returned to their original position and properly
secured.
CAUTION
All electrical parts and wiring must be shielded from torch
flame. DO NOT allow torch to touch insulation; it will char
at 200°F and flash ignite (burn) at 500°F. Excessive heat will
distort the plastic liner.
IMPORTANT: PLEASE RETURN THIS SHEET TO
IT’S ORIGINAL LOCATION.
NOTE
Your Electrolux wine cooler / beverage center has been
designed for either free-standing or built-in installation. When
built-in, your wine cooler does not require additional air space
for top, sides or rear. In either case, the front grille must NOT
be obstructed.
To ease unit installation and removal, it is recommended that
the cabinet rough opening dimensions be increased by at least
¼ inch over the dimensions given for your unit.
All units require zero clearance when installed flush with a
cabinet or wall. Electrolux stainless steel models require a
minimum
wall or cabinet that extends beyond the front edge of the unit.
2⁷⁄₈ inch handle clearance when installed against a
Unit Dimensions
Width Height Depth
13
23
/16 inch 34-5/16-35 inches 263/4 inch