PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT 37°/0°
CONTROL SETTING (2500++ CONTROL)
T
U
R
N
Mounting
Plate
Screws
Mounting
Plate
Screw
Motor
Gear
Timing
Gear
Water Fill
Adjustment
Variable Speed Compressor 65°F (18°C) Ambient 90°F (32°C) Ambient
Operating Time 32 to 40% 100%
Freezer Temperature
Refrigerator Temperature
Low Side Pressure
(cut-in)
Low Side Pressure
(cut-out)
High Side Pressure
-6° to 6°F
-21° to -14°C
33° to 46°F
0.5° to 8°C
5 to 12 psig
34 to 83 kPa
-2 to 2 psig
-14 to 14 kPa
85 to 95 psig
586 to 655 kPa
-6° to 6°F
-21° to -14°C
33° to 46°F
0.5° to 8°C
N/A
-2 to 2 psig
-14 to 14 kPa
120 to 135 psig
827 to 931 kPa
Wattage 40 to 55 60 to 70
Amps (running) 0.5 to 1.1 0.7 to 0.9
Base Voltage 115 vac (127 vac max)
DEFROST SPECIFICATIONS
Thermostat Heater
Cabinet Size
Cut-in Cut-
Watts Ohms
out
23’ SD, 28’ SD, 23’ CD
25°F
(-4°C)
47°F
(8°C)
500 26
Electronic Timer - (ADC) Defrost 24 minutes every 6-96 hours of compressor run time.
CONDENSER FAN MOTOR
Watts RPM Amps
(Energy Star, some models)
3.1
1100 CW
Opposite Shaft
0.03 Running
FREEZER ICE MAKER SPECIFICATIONS
Electrical 115 vac (127 vac max)
Thermostat Opens at 48°F (9°C), Closes at 15°F (-9°C)
Heater Voltage 115 vac
FREEZER ICE MAKER CONNECTOR PLUG CONNECTIONS
Wire Number Wire Color Connects to:
1 Green / Yellow Ground
2 Yellow Water Valve
3 Black Line
4 Light Blue Neutral
SERVICE DATA SHEET
242199300
FREEZER ICE MAKER - AUTOMATIC DEFROST
BOTTOM FREEZER - R134a
IMPORTANT: PLEASE RETURN THIS SHEET TO ITS ORIGINAL LOCATION.
Error Codes Special Modes
Display
FZ FF FZ FF
Interpretation Mode
-- OP Open FF Thermistor Manual Defrost d F FF UP and FF DOWN / same to deactivate
OP -- Open FZ Thermistor Display / Showroom 77 77 FZ UP and FF DOWN / Power-on-Reset
-- SH Shorted FF Thermistor Sabbath Sb Sb FZ DOWN and FF UP / same to deactivate
Shorted FZ Thermistor System Diagnostic No FF or FZ display,
SH --
SY CF
SY CE
UI to Main Control
Board communication
failure; on start up
UI Main Control Board
communication error;
Notes:
• Always check for pin back-outs, pinched or damaged wires before replacing components.
• Determine whether failure is caused by the component, main control board or wiring.
Contact TID before replacing main control board.
• Refer to Service Manual for additional information.
after a period in operation
SY EF Evaporator Fan Failure
LINE
P-3
P-1
BLK
THERMAL
CUT-OUT
CE MAKER
I
GRN / YEL
MOLD
BRN
BLK
MOUNTING
PLATE
MOTOR
RED
MOLD HEATER
165 WATTS
POWER
ICE MAKER
Display Activate/Deactivate
(press for up to 10 sec. simultaneously)
(POR)
FZ UP and FZ DOWN / FF UP to deactivate
all UI LEDs on.
NO
THERMOSTAT
WATER FILL
SWITCH
C
RED
LT. BLUE
NO
NC
BLU
NO
NC
C
SHUTOFF
SWITCH
YELLOW
HOLD
SWITCH
C
BLK
NC
NEUTRAL
ICE MAKER
P-4
RED
P-2
LT. BLUE
WATER VALVE
System Diagnostic Mode
Activate:
Deactivate:
• Tests marked with “*” may not be applicable to this unit and will not be displayed in System Diagnostic Mode.
• Tests displayed in diagnostic mode but not described below are for internal purposes only; advance through.
• View UI display for “on,” “off,” “CL,” “OP,” “SH,” “LO,” “HI” or numerical results of tests.
• Listen for operating sounds; feel for heat or air ow as appropriate to determine results of tests.
Test To activate test: Passing result
-- First Screen -- All LED lights on UI illuminated
-- Second Screen -- All segments on UI temperature displays illuminated
-- Third Screen -- Blank UI display, no lights illuminated, no shadowing; “-” and “+”
28 Dispenser Paddle Press disp. paddle “on” on UI when depressed; “off” when released
1* Standard
Compressor
2 Defrost Heater Press power on-off Defrost limit switch must be closed; verify “CL” in test 26.
3 FF Light Press power on-off With FF door open, FF lights on when “on”; off when “off”
8 Water Valve
(Dispenser)
9 FZ Light Press power on-off With FZ door open, FZ lights on when “on”, off when “off”
10 Auger Motor Press power on-off FF door must be closed.
11 Cube/Crush
Solenoid
41* Perfect Temp Drawer
(PTD)
12* VCC Condenser Fan Press power on-off Fan running when “on”; stopped when “off”
38* VCC Compressor Press power on-off Compressor running when “on”; stopped when “off”
15 Evaporator Fan Press power on-off Fan running for minimum of 10 sec. when “LO” or “HI”; stopped when
22 Damper Press power on-off With inspection mirror, observe damper open when “OP”; closed when “CL”
23 FF Door Open/close FF door “CL” on UI when door closed; “OP” when open
24 FZ Door Open/close FZ door “CL” on UI when door closed; “OP” when open
26 Defrost Limit Switch Activates automatically “CL” on UI when closed; “OP” when open
36 Ice Chute Door Depress ice chute door
29 FF Thermistor Mid-
level
30 FZ Thermistor Activates automatically UI shows temperature sensed by FZ thermistor; pass if within 10°F of temperature
33 Ambient Thermistor
@ Main Board
35* FF Thermistor
Upper-Level
34* Ambient Thermistor
@ UI
0- Firmware
Parameters
2- Main Board
Firmware
4- UI Firmware Press power on-off Displays digit sequence; record
Press FZ UP and FZ DOWN temperature pads for up to 10 sec. simultaneously.
Press FF UP to advance through tests.
Press FF UP for up to 10 sec. Diagnostic Mode will automatically deactivate after 5 min. of
inactivity. Note: Silence alarm.
blinking on FF display side to show location.
Press power on-off Compressor running when “on”; stopped when “off”
Feel for heat from defrost heater when “on”.
If “OP” in test 26, heater will not activate.
Press power on-off FF door must be closed.
Press power on-off FF door must be closed. Do not leave solenoid in activated state.
Press power on-off PTD UI illuminated when “on”, off when “off”
or press power on-off
Activates automatically UI shows temperature sensed by FF thermistor; pass if within 10°F of
Activates automatically UI shows temperature sensed at main board; pass if within +20°F/-10°F of
Activates automatically UI shows temperature sensed by upper level FF thermistor; pass if within
Activates automatically UI shows temperature sensed at UI; pass if within +20°F/-10°F of tempera-
Press power on-off Displays digit sequence; record
Press power on-off Displays digit sequence; record
Be prepared to collect water at dispenser.
Water dispenses when “on”; stops when “off”
Motor running when “on”; motor stopped when “off”
Solenoid activated when “on”; deactivated when “off”
“off”. Feedback failure if fan starts but runs less than 10 sec. Listen for
speed change from “LO” to “HI”.
“OP” on UI when manually opened; “CL” when closed. Or, using “power onoff”, “OP” on UI when solenoid activated, “CL” when deactivated
temperature measured with gauge at mid-level FF thermistor location.
“OP-” if open; “SH-” if short
measured with gage at FZ thermistor location.
“OP” if open; “SH” if short
temperature measured with gauge at main board location.
“OP” if open; “SH” if short
10°F of temperature measured with gauge at upper-level FF thermistor loca-
tion. “OP¯” if open; “SH¯” if short
ture measured with gauge at UI location. “OP” if open; “SH” if short
CAUTION
All electrical parts and wiring must be shielded from torch flame. DO
NOT allow torch to touch insulation; it will char at 200°F and flash ignite
(burn) at 500°F. Excessive heat will distort the plastic liner.
FREEZER ICE MAKER INFORMATION
(Where Applicable)
Test Cycling: Remove cover by inserting screwdriver in notch at bottom and pry-
ing cover from housing. Use screwdriver to rotate motor gear counterclockwise until
holding switch circuit is completed. All components of ice maker should function to
complete the cycle.
Water Fill Volume: The water fill adjustment screw will change the fill time.
One full turn is equal to 20cc (.68 oz.). The correct fill is 102 to 130cc (3.4 to
4.3 oz.). When a water valve is replaced, the fill volume must be checked.
IMPORTANT SAFETY NOTE
The information provided herein is designed to assist qualied repair personnel only. Untrained persons
should not attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before
servicing this appliance.
IMPORTANT
If any green grounding wires are removed during servicing, they must be returned to their original position
and properly secured.
FLIP MULLION HEATER
2
1
MULLION
GROUND
LT. BLU/BLK
GRN/YEL
LT. BLU/WHT
RIGHT
DOOR
GROUND
RIGHT
DOOR HINGE
GROUND
2
1
LT. BLU/BLK
CAB-DOOR INLINES
2
1
3
4
WHT/RED
WHT
BLK
J2
GRY/WHT
GRY/WHT
FREEZER THERMISTOR
BRN
BLU
YEL
RED
FRZR
FAN
(DC)
DEFROST HEATER
BLU
DEFROST
THERM.
GRY/BLK
GRY/BLK
FRESH FOOD THERMISTOR
DAMPER
MOTOR
RED/YEL
BRN/YEL
BLK/YEL
WHT/YEL
1
2
3
4
A1
B1
A2
B2
1
2
3
4
5
6
7
8
9
CATCH
1
2
3
4
5
6
7
8
9
LATCH
1
2
345
6
10
9
8
7
WHT/YEL
BRN/YEL
BLK/YEL
GRY/BLK
GRY/BLK
FRESH FOOD INLINE
IN MACHINE COMPARTMENT
LT. BLU/BLK
LT. BLU
1
2
3
4
5
6
7
8
9
12V- RED
RED/BLK
12V+ BLK
BLK/WHT
12 VDC (120V AC REF.)
VARIABLE SPEED
COMPRESSOR/ INV.
BLK
LT. BLU
RIBBED
NON-RIBBED
NEUTRAL
GROUND
LINE
GREEN
I/M
WATER
VALVE
YEL
COND. FAN
COMPRESSOR
GROUND
WHT/RED
WHT/GRN
8
7
6
5
4
3
2
1
WHT/BRN
WHT/BLU
J2
J1
LED POWER
SUPPLY
YEL/RED
YEL/BLK
LT. BLU
3
2
4
1
BLK/ORN
1
2
WHT/RED
12
11
RED/YEL
12
9
11
8
10
7
6
5
4
3
2
1
1
2
3
6
5
4
12
11
10
9
8
7
14
13
3
5
RED
LT. BLU
2
1
3
BLK/ORN
2
1
BLK/ORN
BLK/BRN
LED IN
LEFT FF DOOR
LED IN
RIGHT FF DOOR
LED POWER
BOARD (J2)
FREEZER
COMPARTMENT
J4B
1
2
3
5
4
6
J4A
1
2
3
4
5
6
J2
7
8
(N) WHITE
(L) PUR
GRN/YEL
3
4
5
FREEZER
INLINE AT
CONTROL BOARD
FRESH FOOD
COMPARTMENT
INLINE AT
CONTROL BOARD
MACHINE COMPARTMENT
INLINE AT CONTROL BOARD
8
7
9
11
10
12
J2
LATCH
CATCH
1
5
LATCH
1
4
1
4
1
CATCH
1 2 3 4 5
6 7 8910
11 12
RED/WHT
BRN/WHT
YEL/RED
LT. BLU
YEL/WHT
BLU/WHT
GRY/WHT
GRY/WHT
YEL/PNK
YEL
BRN
YEL/BLK
LT. BLU
BLK
BLK/WHT
YEL
RED
BLK/PNK
RED/BLK
GRN/YEL
RED
WHT
BLK
131415
YEL/RED
YEL/BLK
LT. BLU
13 14 15
1
2 3 4
5
6
7 8910
11 12 13 14
15
12
9
12
9
1
5
5
1
5
1
LATCH
CATCH
FREEZER DOOR
SWITCH
LED LIGHTS
LED LIGHTS
3
1
3
1
7
9
7
9
2
1
3
4
AIR TOWER INLINE
5
6
7
8
9
GRY/BLK
WHT/YEL
BRN/YEL
BLK/YEL
RED/YEL
GRY/BLK
BLK/ORN
LT. BLU/BLK
1
2
3
4
COIL COVER
GROUND
GROUND ATTACHED
TO CABINET
BEHIND LEFT ROLLER
ICE MAKER
(SEE ICE MAKER
DIAGRAM)
123
4
J1
J3
6
5
4
3
2
13
14
1
15
14
13
12
11
10
8
7
6
5
4
3
2
91
16
1
2
3
4
5
6
8
9
10
11
12
7
J9A
1
1
MAIN BOARD
1 RED
2 WHT
3 BLK
J4A
8
6
3
11
4
5
WHT/YEL
10
2
1
J4B
BRN/YEL
RED/WHT
RED/YEL
BLK/YEL
3
2
5
6
BLK/ORN
YEL
BLK/WHT
1
9
2
10
12
6
11
5
10
4
1
7
2
8
3
9
BRN
YEL/PNK
YEL/BLK
RED
GRN/YEL
BLK
LT. BLU
4
2
3
1
RED/BLK
LT.BLU/BLK
YEL/RED
LT. BLU
YEL
BLK/PNK
13
5
12
4
11
3
6
14
7
15
8
16
J3
J2
J1
DK.BLU/WHT
GRY/BLK
GRY/BLK
GRY/WHT
GRY/WHT
BRN/WHT
YEL/WHT
9
12
14
7
13
4
1
USER INTERFACE BOARD
LEFT DOOR INLINE
RIGHT DOOR INLINES
SPLICE
LEFT
DOOR
GROUND
LEFT
DOOR HINGE
GROUND
2
1
-
+
LED
BLK/ORN
WHT/RED
2
1
-
+
LED
BLK/BRN
BLK/ORN
LEFT DOOR
1
2
1
2
WHT/RED
BLK/ORN
BLK/ORN
BLK/BRN
RIGHT DOOR
BLK/BRN
WHT/GRN
2
1
- +
LED
ZONE 4
FF DOORS AND
BACK OF FREEZER
Z4-3
Z4-1 Z4-2
LED LIGHTS
1
TYPICAL LED CONNECTOR
Z1-3
Z1-2
LED
+ -
1
2
BLK/BLU
BLK/RED
LED
+ -
1
2
BLK/BLU
BLK/PUR
ZONE 1
SIDE AND
TOP LEDS
Z1-4
Z1-1
BLK/RED
WHT/BLU
LED
+-
1
2
WHT/BRN
BLK/PUR
2
1
-+
LED
YEL/RED
Z4-1
Z4-2
J2-3
LED POWER
PCBA
Z4-3
Z1-1
Z1-2
Z1-3
Z1-4
FRESH FOOD
SWITCH (120V AC)
NEUTRAL
FREEZER
SWITCH (120V AC)
J1-1
+
-
+
-
J1-3
J1-4
J2-4
J2-7
J2-8
REFRIGERATOR
LIGHT S
FREEZER
LIGHTS
NEUTRAL
FZR DOOR SW. SENSE
NEUTRAL
LINE
VEE
COMM
GROUND
J9A-1
ASSY_OU T
ASSY__IN
+5V
GROUND
+5V
RESET_ FLASH
BKGD / MSJ
GROUND
JF-4
JF-3
JF-2
JF-1
J8-8
J8-7
J8-6
J8-5
J2-1
J3-1
J3-2
J4A-14
J4A-13
J4B-5
J4A-7
J4B-1
J4B-2
J4B-3
J4A-3
J4A-9
J4A-5
J4A-11
NTC - AMBIENT
LINE
G5LE RELAY
J2-1
NTC - FZR
NTC - FF
DAMPER
MOTOR
CONTROL
LINE
J2-12
J3-8
J2-6
J1-1
J3-9
J1-3
(+12)
VCC(+12)
VS
COM
FG
M
M
NEUTRAL
DEFROST THERM.
DEFROST HEATER
M
OUT 2A
OUT 1B
OUT 2B
UI A
J9A-3
J9A-2
CONDENSER FAN
VCC
COMPRESSOR
DC EVAPORATOR FAN
ISOLATED
ERF2500++ ERROR CODES:
FREEZER DISPLAY:
"OP" OR "2" - FREEZER THERMISTOR "OPEN"
"SH" OR "3" - FREEZER THERMISTOR "SHORTED"
FRESH FOOD DISPLAY:
"OP" OR "2" - FRESH FOOD THERMISTOR "OPEN"
"SH" OR "3" - FRESH FOOD THERMISTOR "SHORTED"
BOTH DISPLAYS:
"SY CE" - COMMUNICATION ERROR
"SY CF" - COMMUNICATION LOST ERROR
"SY EF" - EVAPORATOR FAN ERROR
NEUTRAL
ICE MAKER
FILL VALVE
FZ ICE MAKER OUTPUT
MULLION HEATER
FREEZER ICE MAKER
J3-3
J3-4
LINE
IM WATER SENS E
J3-9
J3-6
LINE (PTD)
ERF2500++
REFRIGERATOR DOOR OPENING IS DETERMINED
BY MAGNETIC SWITCH ON USER INTERFACE
J3-10
J3-11
REFRIGERATOR
LIGHT S
FREEZER
LIGHTS
NEUTRAL
FZR DOOR SW. SENSE
NEUTRAL
LINE
VEE
COMM
GROUND
J9A-1
ASSY_OU T
ASSY__IN
+5V
GROUND
+5V
RESET_ FLASH
BKGD / MSJ
GROUND
JF-4
JF-3
JF-2
JF-1
J8-8
J8-7
J8-6
J8-5
J2-1
J3-1
J3-2
J4A-14
J4A-13
J4B-5
J4A-7
J4B-1
J4B-2
J4B-3
J4A-3
J4A-9
J4A-5
J4A-11
NTC - AMBIENT
LINE
G5LE RELAY
J2-1
NTC - FZR
NTC - FF
DAMPER
MOTOR
CONTROL
LINE
J2-12
J3-8
J2-6
J1-1
J3-9
J1-3
(+12)
VCC(+12)
VS
COM
FG
M
M
NEUTRAL
DEFROST THERM.
DEFROST HEATER
M
OUT 2A
OUT 1B
OUT 2B
UI A
J9A-3
J9A-2
CONDENSER FAN
VCC
COMPRESSOR
DC EVAPORATOR FAN
ISOLATED
ERF2500++ ERROR CODES:
FREEZER DISPLAY:
"OP" OR "2" - FREEZER THERMISTOR "OPEN"
"SH" OR "3" - FREEZER THERMISTOR "SHORTED"
FRESH FOOD DISPLAY:
"OP" OR "2" - FRESH FOOD THERMISTOR "OPEN"
"SH" OR "3" - FRESH FOOD THERMISTOR "SHORTED"
BOTH DISPLAYS:
"SY CE" - COMMUNICATION ERROR
"SY CF" - COMMUNICATION LOST ERROR
"SY EF" - EVAPORATOR FAN ERROR
NEUTRAL
ICE MAKER
FILL VALVE
FZ ICE MAKER OUTPUT
MULLION HEATER
FREEZER ICE MAKER
J3-3
J3-4
LINE
IM WATER SENS E
J3-9
J3-6
LINE (PTD)
ERF2500++
REFRIGERATOR DOOR OPENING IS DETERMINED
BY MAGNETIC SWITCH ON USER INTERFACE
J3-10
J3-11
REFRIGERATOR
LIGHT S
FREEZER
LIGHTS
NEUTRAL
FZR DOOR SW. SENSE
NEUTRAL
LINE
VEE
COMM
GROUND
J9A-1
ASSY_OU T
ASSY__IN
+5V
GROUND
+5V
RESET_ FLASH
BKGD / MSJ
GROUND
JF-4
JF-3
JF-2
JF-1
J8-8
J8-7
J8-6
J8-5
J2-1
J3-1
J3-2
J4A-14
J4A-13
J4B-5
J4A-7
J4B-1
J4B-2
J4B-3
J4A-3
J4A-9
J4A-5
J4A-11
NTC - AMBIENT
LINE
G5LE RELAY
J2-1
NTC - FZR
NTC - FF
DAMPER
MOTOR
CONTROL
LINE
J2-12
J3-8
J2-6
J1-1
J3-9
J1-3
(+12)
VCC(+12)
VS
COM
FG
M
M
NEUTRAL
DEFROST THERM.
DEFROST HEATER
M
OUT 2A
OUT 1B
OUT 2B
UI A
J9A-3
J9A-2
CONDENSER FAN
VCC
COMPRESSOR
DC EVAPORATOR FAN
ISOLATED
ERF2500++ ERROR CODES:
FREEZER DISPLAY:
"OP" OR "2" - FREEZER THERMISTOR "OPEN"
"SH" OR "3" - FREEZER THERMISTOR "SHORTED"
FRESH FOOD DISPLAY:
"OP" OR "2" - FRESH FOOD THERMISTOR "OPEN"
"SH" OR "3" - FRESH FOOD THERMISTOR "SHORTED"
BOTH DISPLAYS:
"SY CE" - COMMUNICATION ERROR
"SY CF" - COMMUNICATION LOST ERROR
"SY EF" - EVAPORATOR FAN ERROR
NEUTRAL
ICE MAKER
FILL VALVE
FZ ICE MAKER OUTPUT
MULLION HEATER
FREEZER ICE MAKER
J3-3
J3-4
LINE
IM WATER SENS E
J3-9
J3-6
LINE (PTD)
ERF2500++
REFRIGERATOR DOOR OPENING IS DETERMINED
BY MAGNETIC SWITCH ON USER INTERFACE
J3-10
J3-11
REFRIGERATOR
LIGHT S
FREEZER
LIGHTS
NEUTRAL
FZR DOOR SW. SENSE
NEUTRAL
LINE
VEE
COMM
GROUND
J9A-1
ASSY_OU T
ASSY__IN
+5V
GROUND
+5V
RESET_ FLASH
BKGD / MSJ
GROUND
JF-4
JF-3
JF-2
JF-1
J8-8
J8-7
J8-6
J8-5
J2-1
J3-1
J3-2
J4A-14
J4A-13
J4B-5
J4A-7
J4B-3
J4A-3
J4A-9
J4A-5
J4A-11
NTC - AMBIENT
LINE
G5LE RELAY
J2-1
NTC - FZR
NTC - FF
LINE
J2-12
J3-8
J2-6
J1-1
J3-9
J1-3
(+12)
VCC(+12)
VS
COM
FG
M
M
NEUTRAL
DEFROST THERM.
DEFROST HEATER
OUT 2B
UI A
J9A-3
J9A-2
CONDENSER FAN
VCC
COMPRESSOR
DC EVAPORATOR FAN
ISOLATED
ERF2500++ ERROR CODES:
FREEZER DISPLAY:
"OP" OR "2" - FREEZER THERMISTOR "OPEN"
"SH" OR "3" - FREEZER THERMISTOR "SHORTED"
FRESH FOOD DISPLAY:
"OP" OR "2" - FRESH FOOD THERMISTOR "OPEN"
"SH" OR "3" - FRESH FOOD THERMISTOR "SHORTED"
BOTH DISPLAYS:
"SY CE" - COMMUNICATION ERROR
"SY CF" - COMMUNICATION LOST ERROR
"SY EF" - EVAPORATOR FAN ERROR
NEUTRAL
ICE MAKER
FILL VALVE
FZ ICE MAKER OUTPUT
MULLION HEATER
FREEZER ICE MAKER
J3-3
J3-4
LINE
IM WATER SENS E
J3-9
J3-6
LINE (PTD)
ERF2500++
J3-10
J3-11
LIGHTS
NEUTRAL
NEUTRAL
LINE
VEE
COMM
GROUND
J9A-1
ASSY_OU T
ASSY__IN
+5V
GROUND
+5V
RESET_ FLASH
BKGD / MSJ
GROUND
JF-4
JF-3
JF-2
JF-1
J8-8
J8-7
J8-6
J8-5
J2-1
J3-1
J3-2
J4A-14
J4A-13
J4B-5
J4A-7
J4A-11
NTC - AMBIENT
LINE
G5LE RELAY
J2-1
J2-6
J1-1
J3-9
J1-3
(+12)
VCC(+12)
VS
COM
FG
M
M
NEUTRAL
DEFROST THERM.
DEFROST HEATER
UI A
J9A-3
J9A-2
CONDENSER FAN
VCC
COMPRESSOR
DC EVAPORATOR FAN
ISOLATED
ERF2500++ ERROR CODES:
FREEZER DISPLAY:
"OP" OR "2" - FREEZER THERMISTOR "OPEN"
"SH" OR "3" - FREEZER THERMISTOR "SHORTED"
FRESH FOOD DISPLAY:
"OP" OR "2" - FRESH FOOD THERMISTOR "OPEN"
"SH" OR "3" - FRESH FOOD THERMISTOR "SHORTED"
BOTH DISPLAYS:
"SY CE" - COMMUNICATION ERROR
"SY CF" - COMMUNICATION LOST ERROR
"SY EF" - EVAPORATOR FAN ERROR
NEUTRAL
ICE MAKER
FILL VALVE
FZ ICE MAKER OUTPUT
MULLION HEATER
FREEZER ICE MAKER
J3-3
J3-4
LINE
IM WATER SENS E
J3-9
J3-6
LINE (PTD)
ERF2500++
J3-10
REFRIGERATOR
LIGHT S
FREEZER
LIGHTS
NEUTRAL
FZR DOOR SW. SENSE
NEUTRAL
LINE
VEE
COMM
GROUND
J9A-1
ASSY_OU T
ASSY__IN
+5V
GROUND
+5V
RESET_ FLASH
BKGD / MSJ
GROUND
JF-4
JF-3
JF-2
JF-1
J8-8
J8-7
J8-6
J8-5
J2-1
J3-1
J3-2
J4A-14
J4A-13
J4B-5
J4A-7
J4B-6
J4B-1
J4B-2
J4B-3
J4A-3
J4A-9
J4A-5
J4A-11
NTC - AMBIENT
LINE
G5LE RELAY
J2-1
NTC - FZR
NTC - FF
DAMPER
MOTOR
REFRIGERATOR
CONTROL
LINE
J2-12
J3-8
J2-6
J1-1
J3-9
J1-3
(+12 )
VCC(+12)
VS
COM
FG
M
M
NEUTRAL
DEFROST THERM.
DEFROST HEATER
M
OUT 1A
OUT 2A
OUT 1B
OUT 2B
UI A
J9A-3
J9A-2
CONDENSER FAN
VCC
COMPRESSOR
DC EVAPORATOR FAN
ISOLATED
ERF2500++ ERROR CODES:
FREEZER DISPLAY:
"OP" OR "2" - FREEZER THERMISTOR "OPEN"
"SH" OR "3" - FREEZER THERMISTOR "SHORTED "
FRESH FOOD DISPLAY:
"OP" OR "2" - FRESH FOOD THERMISTOR "OPEN "
"SH" OR "3" - FRESH FOOD THERMISTOR "SHORTED"
BOTH DISPLAYS:
"SY CE" - COMMUNICATION ERROR
"SY CF" - COMMUNICATION LOST ERROR
"SY EF" - EVAPORATOR FAN ERROR
NEUTRAL
ICE MAKER
FILL VALVE
FZ ICE MAKER OUTPUT
MULLION HEATER
FREEZER ICE MAKER
J3-3
J3-4
LINE
IM WATER SENS E
J3-9
J3-6
LINE (PTD)
ERF2500++
REFRIGERATOR DOOR OPENING IS DETERMINED
BY MAGNETIC SWITCH ON USER INTERFACE
J3-10
J3-11
J1-3
J1-4
J1-1
LED POWER
BOARD
Variable Capacity Compressor (VCC) Diagnostics (select models)
If test 38 fails, diagnose as follows:
→ Check at the connector from the power cord
harness into the inverter board, located in
the machine compartment.
(PUR and WHT wires)
Is Inverter Board receiving 115 VAC
from power supply?
no
• Check voltage supply.
• Check and repair power
cord harness wiring and
connections.
yes
→ Check at Inverter Board on
→ Check at Main Control Board
Identify and repair damaged wires or
poor connections between Main Control
Board and Inverter Board.
Compressor
(BLK and RED wires)
Is Inverter Board receiving 10-15
VAC and 1-5 VDC from Main
Control Board?
(BLK/WHT and RED/BLK wires)
Is Main Control Board sending
10-15 VAC and 1-5 VDC to
Inverter Board?
no
yes
→ Remove inverter box from the
compressor and check resistance
across compressor winding pairs as
yes yes
shown.
Is resistance across all winding
pairs equal?
no
Replace Compressor and
Inverter Board.
no
Replace Main Control Board.
VCC Resistance Check
Check resistance between terminals 1 and
2, 2 and 3, 3 and 1.
If all resistances are equal,
compressor is operative.
→ Check connections from Inverter
Board to Compressor
Are connections from Inverter
Board to Compressor intact?
Identify and repair damaged
wires or poor connections
between Inverter Board and
Compressor.
no
Replace Inverter Board
yes
Wire Diagram 242199201