Once you have your unit installed, we suggest
you keep this manual in a safe place for future
reference. Should any problems occur, refer to
the Troubleshooting section of this manual. This
information will help you quickly identify a problem
and get it remedied. In the event you require
assistance, please contact the dealer where you
purchased your unit.
Electrolux Model Number
Electrolux Serial Number
Dealer Name
Dealer Address
Dealer Telephone
Keep this manual and the sales receipt together in
a safe place for further reference.
For toll-free telephone support in the U.S. and
Canada: 1-877-4ELECTROLUX (1-877-435-3287)
For online support and product information visit
http://www.elect roluxusa.com
©2007 Electrolux HomeProducts, Inc.
Post Office Box 212378, Augusta, Georgia30917, USA
All rights reserved. Printed in the USA
TaMe of Contents
Finding Information
FindingInformation ................................................. 2
Pleasereadandsave this guide.............................................. 2
Keepa record for quick reference........................................... 2
Questions?.............................................................................. 2
Tableof contents..................................................................... 3
Safety.................................................................. 4
Important SafetyInstructions .................................................4
Safety Precautions............................................................... 4
Definitions........................................................................... 4
GeneralPrecautions ............................................................ 4
Installation ............................................................ 5
Installation Dimensions .........................................................5
Installingthe Drain..................................................................5
GravityDrain................................................................... 5
Connectinga Drain Pump....................................................... 6
Site Preparation...................................................... 7
Preparingthe Site ..................................................................7
Water Supply Connection ........................................... 8
Connectingthe Water Supply..................................................8
Leveling............................................................... g
Leveling the Unit ..................................................................... 9
Operation............................................................ 14
NormalOperation.................................................................14
IceCubeThickness...............................................................14
IceDispenserOperationandCare.........................................14
IceCubeThicknessAdjustment............................................15
DrainPump...........................................................................15
Maintenance ........................................................ 16
Special Considerations.........................................................16
Maintaining and CleaningYour Ice Maker.............................16
ExteriorCleaning - AsRequired.........................................16
StainlessSteel Models.......................................................16
Interior Cleaning - As Required .........................................16
CondenserCleaning- Every3 Months ..................................17
Self Cleaning - Every 6 Months.............................................17
Inlet Screen Cleaning- EveryYear........................................19
Storing, Vacationand Moving ................................... 19
Drainingfor Non-Use............................................................19
Troubleshooting.................................................... 20
BeforeyouCallforService....................................................20
If ServiceisRequired............................................................21
Warranty Information ............................................. 22
_nstallation Dimensions
Installation
34 - 1/8"
(86.7)
FULL
RETRACT
HEIGHT
WATER"
OUTLET
_nstamlin9 the Drain
WATER
- DRAIN
I_ (61) _"
24 _
WATER
VALVE _ (_
(55.2)
Drain lines must have a 1 inch drop per 48
inches of run (1/4 inch per foot) and must not
create traps.
The floor drain must be large enough to
accommodate drainage from all drains.
Insulate the bin drain line to prevent
condensation.
Model EI151M55GS can be installed using a gravity
drain or the Electrolux EIMP60, optional drain
pump kit.
Follow these guidelines when installing drain lines
to prevent water from flowing back into the ice
maker storage bin and/or potentially flowing onto
the floor causing water damage:
Gravity Drain
• Drain lines must have a 5/8 inch inside
diameter.
SCREWS
Figure 1
_!_!ii_i_i_;_!_!ii!_!_!_i_:i!i!!i!i!i_i_!i_i_!!i_i!!!i_i!!!i_i!!!i_i!!!i!i_!_!_i_!_!_i_!ii:i_i_i_i_i_i:_i_i_i_ii_i!!i_i_iii
Installation
connectingaorainpump
] Ifagravitydrainconnection isnotavailable, we
strongly recommend the useofthe Electrolux
EIMPeOdrain pump. The Electrolux EIMP60
drain pumpisavailablethrough your Dealer, or
directfrom Electroluxwith complete installation
instructions. Ifa pumpotherthan the Electrolux
EIMP6Odrain pump isto be used, itmustmeetthe
followingspecifications:
, it must be UL listed and have a UL listed
120VAC,3-w_regroundedpowercord.
• it must have overall maximum outside
d_me_s_onsofs-3J4'w_dexS-3J4'deepx
, 7-3/4' high.
It must have a minimum flow rate of 15
• gallonsperhouratlOfeetoflift.
Itmusthaveasealedsumpwhichdoesnot
allowwaterleakage in thecaseofa power
outage, restricted drain orpumpfailure.
.....::: , Itmusthaveacheckvalveinthedischarge
..... lineto preventwastewaterreturn tothe
pump.
, It must have an overflow protection control
which will shut off power to the ice maker in
the event of a pump failure.
• It must have an operating temperature range
of 50°F to 110°F (10°C to 43°C).
Site Preparation
÷pa _ e S ÷
Pr fir% th it 7 iThelundmuSstnbeornd_tnanedeaCC°rdngt°Y°Ur
1 Position the unit on a flat, level surface,
capable of supporting the entire weight of
the unit. Remember that the unit will be
significantly heavier once it is fully loaded.
2 The surrounding air temperature must be at
least 50°F (10°C) but must not exceed 1IO°F
(43°C).
3 The unit must not be located near heat-
generating equipment or in direct sunlight.
OR WALL
iiiiii_i!@ii!!iiii!iiiii!ili_iiii!_@i,i!ii,!!!i@i!i_iii_ii!_ili
Figure 2
0 II
CLEARANCE
NEEDED