Identification:
Technical
Bulletin no:
Date:
Issuer:
Factory:
Subject
Model
Problem
Reason
Action in
Factory
D02-D04
CG-2004_02 (page 1 of 1), 1st ed.
29 April 2004
R. Sartor (DWS Customer Support)
DW Vallenoncello - Italy
Peristaltic Dispensers in UC and HT
Undercounter range and Hood Type range with peristaltic Rinse Aid Dispenser
(atmospheric boiler versions) and / or Detergent Dispenser.
Not filling because of broken squeezing wheel (rotary rollers holder).
It’s due to a contamination of the polycarbonate by residual of cutting oil for
motor shaft production.
From May 2003 the supplier has introduced cleaning (with a specific solvent)
of all motor shafts.
Moreover since serial number 41600001 we have introduced rollers holder in
Pocan® (PBT) that is more cutting oils-proof and has higher mechanical
characteristics than Makrolon® (PC) we have used so far.
The new rotary rollers holder is black while the old one was yellow:
Action in
Field
OLD 049625 NEW 049625
New dispensers are perfectly interchangeable towards previous ones.
All peristaltic dispensers in SPLC Pordenone warehouse have been
recovered. Their spare part codes are:
• Rinse Aid Dispenser 049625 and 0L0506 (black V-0 plastic case for North
America models).
• Detergent Dispenser 049624 and 0L0507 (black V-0 plastic case for North
America models).
The present modification/upgrade can be retrofitted and it is not mandatory.