Information about safety
The hood is destined uniquely for non-professional use in a domestic setting. It complies with international
safety quality regulations and requisites. The safety measures cannot, however, eliminate all risks of accidents.
Read the instructions, suggestions, and warnings carefully before installing and starting to use the hood.
Pay particular attention to the paragraphs with a triangular warning symbol to avoid damage to people or
objects. We recommend conserving the instructions booklet that must be supplied in case of sale or cession
of the hood to third parties.
During use
Never leave fried food, melted fat, paraffin or other inflammable liquids unattended on the cooking top.
In case of fire: turn the hood and the cooking top off immediately. ATTENTION! Put the fire out with a lid. Do not
use water.
Flambé cooking beneath the hood is forbidden because it could provoke a fire. Remember that overheated oil can
begin to burn spontaneously. Never leave a frying-pan unattended.
The anti-fat filter of the hood must be cleaned periodically to avoid fat dripping onto the cooking top and catching
fire. Read the chapter on Maintenance and cleaning in the instruction booklet.
Waste Disposal
Avoid accidents during the disposal of waste from the aspiration hood. Disconnect the plug from the electricity
socket and the supply cable from the entrance of the hood. Contact the local authorities for information about the
disposal of waste from the aspiration hood, or contact AB Elektroservice.
How to use the instructions
In the text you will find the following symbols that will guide you through the instructions:
Information about safety.
Environmental information.
Installation and assistance
Every eventual electrical connection must be carried out by a specialised electrician and the installation of the hood
must be carried out by a qualified technician. The installation of the hood by non-qualified personnel can lead to
malfunctioning of the hood and cause damage to people and/or objects.
Installation must be carried out in conformity with the Boverket regulations.
The hood must be installed at least 400 mm above the cooking top or electric plates, or at least 650 mm above
gas rings or gas tubes.
Check that the connection cable is not crushed during installation.
The hood is considered unconnected only when the plug or the fuse is disconnected.
Observe the rules and regulations concerning the elimination of fumes. The waste tube of the hood cannot therefore
be connected to a tube that is used for removing fumes from equipment supplied by power different to electricity,
e.g. a boiler or a fireplace.