Electrolux E36EC65ESS User Manual

Page 1
36" ELECTRIC DROP-IN COOKTOP
Configuration
FEATURES
Black Ceramic Smoothtop Glass Surface Professional-Style Knobs with Digital Display Blue LED Indicator Light 6" to 9" Dual Element – 1200W/ 2500W 5" to 7" to 9" Expandable Element – 1000W/ 1800W/2700W 6" Element – 1200W Spill Control Cooktop A.D.A. Compliant*
ACCESSORIES
Granite Countertop Installation Kit – PN# 903061-9010
SPECIFICATIONS
Overall Exterior Dimensions –
Width Depth
Height Power Supply Location Amps@ 240/208 Volts Connected Load (kW Rating) @ 240/ 208 Volts Electrical – Single phase 3- or 4-wire cable, 120/ 240V or
120/ 208V, 60Hz, fused on both sides of line with ground. Armored Electrical Cable Approved for Single Oven Combination Installation** Approved for Downdraft Vent Combination Installation*** Shipping Weight (Approx.)
*When properly installed, meets the appliance standards in the Americans with Disabilities
Act and the Architectural Barriers Act Accessibility Guidelines as published by the United
States Access Board on June 23, 2004, as amended August 5, 2005. ** Not approved to be used over any Electrolux ICON®Single Wall Oven. ***Approved to be used in combination with an Electrolux ICON®Downdraft Vent. NOTE: Always consult local and national electric codes. Refer to Product Installation Guide
for detailed installation instructions on the web at electroluxicon.com.
Specifications subject to change.
5 Electric Elements
Yes 5 Yes 2 1 2 Yes Yes
Optional
36-3/4" 21-1/2" 4" Middle Rear
42.0/ 36.5
10.16/ 7.63 Required
Included No Yes 50 Lbs.
electroluxicon.com
Electric Drop-In Cooktop
E36EC65ESS
Professional-Style Knobs with Digital Display
The large, professional-style control knobs provide precise control and convenient preset digital settings.
Expandable Elements
Flexible elements with up to 4,400 watts of power expand to fit virtually any pan size so you have the utmost versatility.
Sleek Smoothtop Glass Design
The smooth, glass design of the cooktop seamlessly integrates with your countertop for a polished, premium look, making it easy to clean.
Blue LED Indicator Light
A blue LED indicator light remains illuminated until the surface is cool to the touch.
Page 2
Electric Drop-In Cooktop
E36EC65ESS
High standards of quality at Electrolux Home Products, Inc. mean we are
constantly working to improve our products. We reserve the right to change
specifications or discontinue models without notice.
Electrolux Major Appliances, N.A.
USA
10200 David Taylor Drive •Charlotte, NC 28262 •1-877-4electrolux (1-877-435-3287)
electroluxicon.com
CANADA
5855 Terry Fox Way •Mississauga, ON L5V 3E4 •1-800-265-8352
electroluxicon.ca
E36EC65ESS 04/11 © 2011 Electrolux Home Products, Inc. Printed in the U.S.A.
36" Electric Drop-In Cooktop Specifications
Product Weight – 44 Lbs.
Single phase 3- or 4-wire cable, 120/240 or 120/208 Volt, 60 Hertz AC only electrical supply with ground required on separate circuit fused on both sides of line.
Connected Load (kW Rating) @ 240/208 Volts = 10.16/7.63kW
Amps @ 240/208 Volts = 42.0/36.5 Amps
Always consult local and national electric codes.
Allow 2" space below armored cable opening to clear electrical cable and allow space for installation of junction box on wall at back of cooktop.
Overhead cabinetry should not exceed a 13" maximum depth.
Allow 30" minimum clearance between top of cooktop and bottom of unprotected wood or metal overhead cabinetry.
Absolute minimum horizontal distance between overhead cabinets installed to either side of appliance must be no less than maximum width of appliance.
Allow 24" minimum clearance when bottom of wood or metal overhead cabinet is protected by not less than 1/8" flame-retardant millboard covered with not less than No. 28 MGS sheet steel, 0.015" stainless steel, 0.024" aluminum or 0.020" copper.
Allow 2" minimum clearance between rear edge of cutout and nearest combustible surface above countertop.
Allow 7-1/2" minimum clearance from edge of cooktop to nearest combustible wall on either side of unit.
It is recommended that drawers not be used beneath cooktop.
To reduce risk of fire when using overhead cabinetry, install vent hood that projects horizontally a recommended minimum of 5" beyond bottom of cabinets.
Electric Drop-In Cooktop model E36EC65ESS is NOT approved to be used over any Electrolux ICON®Single Wall Oven.
Electric Drop-In Cooktop model E36EC65ESS is approved to be used in combination with an Electrolux ICON
®
36” Downdraft Vent. (Refer to
Drop-In Cooktop/Downdraft Vent Countertop Preparation page on web for detailed installation specifications.)
Note: For planning purposes only. Refer to Product Installation Guide
on the web at electroluxicon.com for detailed instructions.
Optional Accessories
Granite Countertop Installation Kit – (PN# 903061-9010).
355/8"min.
36"max.
Approximate location of junction box
4"x 8" opening to route armored cable
6" min.
25"min.
71/2" min. to nearest combustible wall (either side of unit)
24"
2" min. recommended distance between rear edge of cutout and nearest combustible surface above countertop
10"
12"
201/4" min.
20
1
/2" max.
21/2" max.
363/4"
211/2"
4"
36 3/4"
13"
max.
cabinet
depth
18"
min.
30" min. for
unprotected cabinet
24" min. for
protected surface
Side inset 3/8"
Page 3
Drop-In Cooktop/Downdraft Vent Countertop Preparation Specifications
For detailed Drop-In Cooktop installation, refer to model-specific product page and installation guide on web. Plan installation so that all required minimum clearances between cooktop, overhead cabinets and adjacent vertical walls are provided.
Position cooktop/vent cutout so all required minimum clearances are met.
Minimum flat countertop area must meet or exceed combined overall width and depth as shown. Standard 25" countertop depth may NOT be adequate for some cooktop/ vent installations, especially with backsplash.
Separate circuits required for cooktop and vent. (Refer to product-specific
electrical specifications.)
Always consult local and national electric and gas codes. Check local building codes for installation requirements, as they may vary per locale.
Downdraft Vent Specifications
For detailed Downdraft Vent installations, refer to model-specific product page and installation guide on web.
Voltage Rating –120V / 60Hz/15 Amps
Connected Load (kW Rating) @120 Volts = 1.0kW (For use on adequately wired 120V, dedicated circuit having 2-wire service with a separate ground wire. Appliance must be grounded for safe operation.)
Amps @120 Volts = 8.0 Amps
Vent unit outside of building only.
Vent must be installed in vertical orientation only.
1,600 CFM remote exhaust blower (PN# 5304444802) included with vent – shipped in separate box.
Do not use flexible duct. Round duct instead of rectangular duct recommended, especially when elbows are required.
When multiple elbows are necessary, ensure a minimum of 24" of straight duct between any two elbows.
Thermal breaks such as short section of nonmetallic duct, should be used in areas of extreme cold.
For most efficient airflow exhaust, use a straight run or as few elbows as possible.
Cold weather installations should have additional backdraft damper installed.
Installing a Downdraft Vent in combination with any gas cooking surface will affect optimum burner efficiency.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at electroluxicon.com for detailed instructions.
Drop-In Cooktop/Downdraft Vent Countertop Preparation
High standards of quality at Electrolux Home Products, Inc. mean we are
constantly working to improve our products. We reserve the right to change
specifications or discontinue models without notice.
Electrolux Major Appliances, N.A.
USA
10200 David Taylor Drive •Charlotte, NC 28262 •1-877-4electrolux (1-877-435-3287)
electroluxicon.com
CANADA
5855 Terry Fox Way •Mississauga, ON L5V 3E4 •1-800-265-8352
electroluxicon.ca
DIC_DDV_PREP 10/10 © 2010 Electrolux Home Products, Inc. Printed in the U.S.A.
Countertop Preparation for 30" & 36" Drop-In Cooktop/Downdraft Vent Installation
29/16"
1
/4" min.
flat ledge
Backsplash
3
/4" max.
* Overall flat ledge behind
backside of cabinet front
** Minimum flat surface required
to fit top surface of cooktop and downdraft vent cap
A
Vertical noncombustible surface - rear wall
25"
B
Top
23 1/4"
min.
Flush with
back side of
cabinet front
D*
E**
C
Stiffener
Back side of
cabinet front
Vent unit
21/8"
Countertop raised lip
Countertop backsplash
Downdraft chimney top
Cooktop
25"
(standard countertop)
*
23
1
/4"min.
213/16"
3"
Vertical noncombustible surface - rear wall
Studwall
3
/4" max. backsplash thickness
1
/4"min. flat ledge
115/16"
9
/32"
213/16"
Cooktop Installation Note:
To ensure proper installation, refer to model-specific installation guide on web for cooktop dimensions, cutout dimensions and cabinet requirements. Due to varying cooktop depths, tight fit is possible between cooktop and vent.
Countertop Preparation Note:
Be aware of areas of potential interference called out in illustration. Countertop with raised lip and/or backsplash may not allow enough flat area for proper installation, 2-13/16" of flat countertop required behind cooktop. No gap required between back of cooktop and front of downdraft trim piece.
*Standard 25" countertop depth may NOT be adequate for some cooktop/vent installations, especially with backsplash.
E30DD75ESS/30" Cooktop Cutout Dimensions
30" Cooktops A B C D E
E30EC65ESS 30" 27
3
/4" 20 3/8" 23 3/16" 24 3/16"
E30EC70FSS 30" 27
3
/4" 20 1/4" 23 1/16" 24 1/16" E30GC64ESS 27 1/2" 27 3/4" 19 7/8" 22 11/16" 23 11/16" E30GC70FSS 28
1
/2" 27 3/4" 19 3/4" 22 9/16" 23 9/16"
E30IC80ISS 29
3
/4" 27 3/4" 20 1/2" 23 5/16" 24 5/16"
E36DD75ESS/36" Cooktop Cutout Dimensions
36" Cooktops A B C D E
E36EC65ESS 36" 33
3
/4" 20 3/8" 23 3/16" 24 3/16"
E36EC70FSS 36" 33
3
/4" 20 1/2" 23 5/16" 24 5/16" E36GC65ESS 33 3/4" 33 3/4" 19 7/8" 22 11/16" 23 11/16" E36GC70FSS 34 1/2" 33 3/4" 19 3/4" 22 9/16" 23 9/16" E36IC80ISS 36" 33 3/4" 20 1/2" 23 5/16" 24 5/16"
For detailed cooktop and downdraft vent installation specifications, refer to model-specific product page and installation guide on web